Home
Operating instructions
Contents
1. Operating instructions LiBus interface box Catalogue number LCZ 9727 These instructions only apply in conjunction with the operating instructions for the LAUDA thermostat where the interface box is connected to LAUDA DR WOBSER GMBH 4 CO KG Pfarrstra e41 43 97922 Lauda K nigshofen Germany English Phone 49 0 9343 503 0 Translation of the original Operating Instructions Fax 49 0 9343 503 222 release 11 2014 a2 E mail info lauda de YAAE00 7 Internet http www lauda de LiBus interface box Table of contents 1 SAFETY INFORMATION ac 4 UP STRUCTURE OF THE SAFETY INFORMATION tice BEE ee ers 4 1 2 GENERAL SAFE INFORMATION dci 4 SPESIARSARE INFORMA Ep 4 2 DEVICE DESCRIP TION 5 INTENDE DUSE ios 6 222 ANONE INDENDE ss a re a 6 2 3 RESPONSIBILITY OF THE OPERATING BODY SAFETY INFORMATION eher 6 3 INSTAELING OF MODULES iia ai les 7 A 8 Explanation of symbols E Note Here something in particular needs the reader s attention gt Reference Refers to other information in different sections YAAE0027 13 Nov 14 Table of contents 3 LAUDA LiBus interface box 1 Safety information 1 1 Structure of the safety informa
2. operators have read and understood the operating in structions e The interface box must be used as intended e operating instructions of the thermostatic unit with which the interface box is to be operated continue to be applicable 6 Device description YAAE0027 13 Nov 14 LiBus interface box 3 Installing of modules Notice Touching the PCB of the module when unpacking and installing PCB may be impaired in their function or irreversibly dam aged e When handling PCBs the requirements of ESD pro tection according to DIN EN 61340 must be ob served Installation in a module slot is shown here with reference to a Proline device In the interface box the same procedure applies To install the module the LiBus interface box must not be connected to the thermostat When handling PCBs the requirements of ESD protection according to DIN EN 61340 must be observed Remove the module from its packaging lf the LiBus interface box is already connected to the thermostat turn off the thermostat and re move the cable of LiBus interface box from the thermostat Remove the screws on the plastic cover if pre sent Insert a screwdriver into the lower recess of the module cavity and prise up the plastic cover The cover can then be pulled off down wards Pull out the plug of the bus connecting cable from the plastic cover YAAE0027 13 Nov 14 Installation 7 LiBus interface b
3. ox Plug on the bus connecting cable red plug onto red socket Insert the module and secure with the two cross head screws The LiBus interface box can be connected to the thermostat The plugs are protected against reverse polarity The plugs have a ridge which slides ES into a groove in the socket It may first the LiBus interface box be equipped with modules and only then the thermostat 4 Operation First connect the LiBus interface box to the thermostat and then switch on the thermostat First switch off the thermostat then separate the LiBus interface box from the thermostat 8 Operation YAAE0027 13 Nov 14
4. thermostat the number of LiBus interfaces extended by two slots LiBus is short for LAUDA internal BUS CAN based 1 Socket 70S 2 two slots for interface modules 57 mm x 27 mm 3 Control cable EKS 067 for connection to a thermostat with 70S socket 1 Type label YAAE0027 13 Nov 14 Device description 5 LAUDA LiBus interface box 2 1 Intended use The LAUDA LiBus interface box is built exclusively for use with the following LAUDA thermostats The used thermostats must have a socket 70S LAUDA Eco LAUDA Integral XT LAUDA Proline LAUDA Proline Kryomate The interface box must only be operated as intended and under the conditions stated in these operating instructions Any other operating mode is not regarded as intended use 2 2 Non intended use The device must not be used e for medical pharmaceutical applications e when sited outdoors It is not allowed to connect e several identical interface modules e several Command remote controls e several identical solenoid valves e several electric heating of the bath bridge 2 3 Responsibility of the operating body safety information The operating body is responsible for the qualifications of the operating personnel e The interface box must only be configured installed maintained and repaired by specialist per sonnel e Persons operating the interface box must be instructed in their work by a specialist e Make sure that specialist personnel and
5. tion Notice Type and source Consequences in the case of non compliance e Measure 1 e Measure A notice warns about possible property or environmental damage 1 2 General safety information Read through the operating instructions carefully They contain important information for working with this device If you have any queries please contact our Service Department Follow all the directions in these operating instructions Only in this way is the correct procedure ensured when working with the device These operating instructions apply only in relation to the operating instructions of the LAUDA ther mostat where the interface box is connected e Make sure that the device is only operated by instructed specialist personnel e Do not make technical modifications to the device Infringements in this respect invalidate the warranty e Have repairs carried out only by specialists 1 3 Special safety information The use of the interface box is only admissible under the following conditions e Indoor use External installation of the box is not considered intended use e Operation up to a height of 2000 m above sea level is admissible e The siting surface must be impervious flat non slip and non combustible Do not position the device at the edge of the bench or table 4 Safety information YAAE0027 13 Nov 14 LiBus interface box LAUDR 2 Device description When connecting the LiBus interface box to a