Installation and Operating Instructions Variable area flow meters SGM

image

Contents

1. Retrofitting the eddy current brake In connection with the indicator part with EM current output and contactors be aware of the fact that short time movements of the pointer may occur when the eddy current brake is being installed These may possibly generate a false alarm or cause peaking of the current output screw The eddy current brake consists of two parts The brake with retaining ring can clipped on to the pointer cylinder independent of built in components such as EM contacts or totalizers When mounting the brake bear in mind that the slot between the brake magnets measures only approx 3 mm und the aluminium pointer vane has a material thickness of 1 mm Check that the pointer vane can be moved between the magnets without coming into contact with them Slightly turn the eddy current brake clockwise and screw in the clamping screw Adjust the brake as shown on on the right and tighten down the clamping screw Flow totalizer EMZ In combination with the current output EM the flow totalizer MG NZRORRMOK2IESK can also be retrofitted in the indicator part a Civ 25 14871 M 1997 When ordering the totalizer as a retrofit kit please specify ETHYLALKOHOL the device data as shown on the right as well as the o os measuring range These data will enable the new scale E Be with totalizer display cutout to be prepared in readiness FIRC 1121D for installation The flow totalizer is then preset wi
2. 13 wa W zw wil a y 6 1 2 Version PTFE ceramics PTFE float Ceramic float Size Water Pressure Water Pressure Air Pressure drop drop drop Wh mbar ih mbar m h iN mbar 15 1 2 25 25 65 3 30 62 4 0 40 66 5 50 64 0 18 1 8 64 6 3 63 66 7 70 66 0 24 2 4 66 10 100 68 13 130 68 0 40 4 0 68 16 160 72 20 200 70 0 65 6 5 70 25 250 86 25 250 72 0 90 9 0 72 40 400 111 25 1 63 630 70 50 500 55 18 18 55 100 1000 80 70 700 60 2 2 22 60 160 1600 108 110 1100 70 3 0 30 70 250 2500 158 160 1600 82 5 0 50 82 250 2500 100 75 75 100 50 2 400 4000 81 450 4500 70 14 140 70 630 6300 110 630 6300 80 20 200 80 1000 10000 170 1100 11000 110 35 350 110 80 3 1600 16000 81 1600 16000 70 2500 25000 95 2500 25000 85 100 4 4000 40000 100 Devices for gas measurement float damping system recommended 1 i N at STP 0 C and 1 013 bar abs 6 2 Materials Version Measuring tube float Temperatur Ambiente 80 C lt 120 C SGM VA SS SS 300 C SGM CA Hastelloy C Hastelloy C nn An SGM PTFE PTFE PTFE 70 C lt 70 C a PIFE _ PTFE ceramics 150 C IE SGM TFM K TFM ceramics 250 C lt 120 C Indicator Scale casing Aluminium enamelled Pointer Aluminium enamelled Scale Aluminium coated Window Float glass 1 Measuring tube of stainless steel 1 4404 with liner A Kirchner amp Tochter GmbH Dieselstra
3. A factor between 1 and 1099 can be set using Buttons 1 to 3 Factor O is not defined Button 1 ones Button 2 tens Button 3 hundreds and thousands The Reset button is used to confirm and terminate entries The totalizer then goes into the display mode previously selected A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters A N 3E 31 wa VY Ey lt 4 Totalizer content The totalizer content is saved in the case of a power failure and can be set to zero with the RESET button during operation Totalizer overflow is signalled by all decimal points lighting up Zero reset is carried out by pressing the RESET button Adjustment Adjustment is not required since the totalizer has been factory adjusted to the current measuring range Should nevertheless readjustment be required this can be done as follows 1 at the moment of switching on keep the RESET button depressed until three decimal points light up Set 4 00 mA and then press Button 1 until digit O appears Set 20 00 mA and then press Button 3 until digits 100 appear Exit the adjustment mode by pressing Button 2 PwWNn A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow me
4. bolts 4 fit washers and tighten down with nut max 8 Nm Caution be aware of mounting position of the fastening clips DN15 DN25 DNSO DN80 DN100 Compare the position of the pointer with the previously recorded value indicated If there is any deviation 1 Use a screwdriver to hold the pointer spindle see Figure 2 Move the pointer to the recorded value counter to the friction forces of the measuring pointer mount 12 7 Disposal Please help to protect the environment by disposing of the workpieces used in accordance with current regulations or by continuing to use them A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters The variable area flow meter SGM meets all requirements of the EC Directives applicable to the product e EMC Directive 89 336 EEC EN 61326 03 1997 A1 04 1998 AD 03 2001 e ATEX 94 9 EC EN 50014 1997 A1 A2 EN 50020 1994 e DGRL 97 23 EC The Kirchner equipment has been tested in compliance with the applicable CE regulations of European Community The respective declaration of conformity is available on request The KIRCHNER QM System is certified in accord with DIN EN ISO 9001 2000 The quality is systematically adapted to the continuously increasing demands Kirchner und Tochter A Kirchner amp Tochter GmbH Die
5. concerned limit values are specified in the Section Technical data and should not be exceeded Only devices that bear the EEx marking may be operated in hazardous areas A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 2 4 2 5 2 6 Variable area flow meters A A za zu i zu 5 m a wa V ay p Information for Operator and operating personnel Authorized installation operating inspection and maintenance personnel should be suitably qualified for the jobs assigned to them and should receive appropriate training and instruction All persons charged with assembly mounting operation inspection and maintenance duties must have read and understood the operating instructions Gaskets in contact with the fluid product must be replaced after all maintenance and repair work Regulations and directives In addition to the regulations mentioned below pay attention without fail to the AN notices given in Section or operation in hazardous areas All relevant regulations should be observed in respect of flow meter operation These include in particular Regulation concerning explosion protection ExVO National ATEX 95 Regulation concerning safe working conditions Directive 1999 92 EC ATEX 137 If appropriate regulation concerning hazardous materials Accident prevention regulations Pressure Equipment D
6. electrical signal output explosion proof design A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters A N 8 F BA u 4 4 3 Description Indicator of modular design A module rack in the indicator accommodates all electrical options and the scale plate The modules pertaining to the electrical options see Figure and the scale plate are inserted in the rack using the plug in technique The modules can be replaced or retrofitted without interrupting the process and without having to remove the pointer If actual temperatures are higher than the max allowable process temperatures for the standard version the indicator can be subsequently adapted to suit the new operating conditions by using an adapter HT version Measuring parts made of various materials and fitted with different liners are available for the process media The flow meter can be ordered with magnetic filter and or float damper and these can also be retrofitted In the case of variable or pulsating flows an eddy current brake can additionally be installed to dampen the pointer An indicator part of stainless steel is available on request Indicator Measuring part optionally as high optionally with temperature version heating system Scale plate Electrical signal output EM Contacts IK1 IK2 IKS1 IKS2 t
7. flow rate Transmission is force free and hysteresis free The ESK2A has been factory calibrated on the basis of the flow measuring range The calibration values used for linearization of the indicator are stored in a memory module EEPROM The required power supply is a functional extra low voltage with protective separation galvanic in accordance with VDE 0100 Part 410 All instruments indicators recorders connected to the measuring circuit are connected in series and together may not exceed the maximum external resistance see 8 3 The ESK A features polarity reversal protection Compliance with IP degree of protection To comply with the IP degree of protection for built in electrical equipment please pay attention to the following points 1 After inserting the connection cable tighten the cap nut on the cable gland 2 Close off all unused cable glands with blanking plugs 3 Do not kink cables directly at the cable gland 4 Provide a water drip point 5 Ensure incoming cables are not subjected to mechanical loads Cable glands screwed cable glands Thread Material Wire diameter Protection Comment M 16x1 5 PA 5 10 mm IP 68 5 bar Standard M 20x1 5 PA 8 13 mm IP 68 5 bar M 16x1 5 nickel plated brass 5 9 mm IP 68 5 bar M 20x1 5 nickel plated brass 10 14 mm IP 68 10 bar Degree of protection restricted to screwed cable gland only A Kirchner amp Tochter GmbH Diese
8. web de Version 1 7 Variable area flow meters A N 18 F _ yl Vy yy lt 4 7 2 Setting the limit value Setting is made directly via the contact pointer 2 Scale opening Unscrew housing cover Move scale to the side Slightly loosen locking screw 1 Slide scale back up to point where it snaps into place Set contact pointer 2 to the desired switching point After setting the pointer 2 should be tightened down again with locking screw 1 A Uu O1 6 Replace housing cover and screw down 73 Switching contact definition MIN contact An alarm is generated when the pointer vane 1 dips into the slot When the pointer vane is outside the slot type initiator a wire break will also cause an alarm to be initiated No wire break identified by SB3 5 E2 Option version as Maximum contact In the alarm status the vane is located outside the slot Wire break identification not available in this case MAX contact An alarm is generated when the pointer vane 1 dips into the slot and dampens this initiator When the pointer vane is outside the slot type initiator a wire break will also cause an alarm to be initiated No wire break identified by SB3 5 E2 Option version as Minimum contact In the alarm status the vane is located outside the slot Wire break identification not available in this case ae In the IK2 IKS2 version both contact systems are equipped A
9. Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters lJ 19 w y oy y 7 3 1 Technical data 2 wire 3 wire SC3 5 NO Y SB3 5 E2 NAMUR Switching element NC contact PNP function NO contact Nom voltage Uo 8V 10 to 30 V Current consumption Flag not sensed 23 MA lt 0 3 V Flag sensed lt 1 mA Ub 3 V Continuous current max 100 mA No load current lo lt 15 mA 7 3 2 Electrical data Built in Identification data equipment Pi mW Ci nF Li uH SC3 5 NO Y lt 16 lt 25 lt 64 lt 150 lt 150 lt 16 lt 52 lt 169 lt 150 lt 150 SJ3 5 SN 16 lt 25 lt 64 lt 30 lt 100 dependent on the isolation switching amplifier used Operation of the SC3 5 NO Y contact requires the use of an isolation switching amplifier e g Pepperl Fuchs Series KF SRe A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters 20 74 7 5 A cy zum mW zu vr p Installation 1 Unscrew housing cover if necessary remove flow totalizer EMZ Bring contact pointers 1 together in the middle Undo locking screw 2 of contact pointers Slide the plug in contact unit into the third rail up to the point wher
10. Retrofitting the eddy current Brake 35 12 4 Flow totalizer EMZ nennen enennelnn 35 12 5 High temperature version indicator part naaa 36 12 2 1INstalation anna 36 12 6 Mounting the indicator uu eessssssessssesssessesssessuesssscssscsnscsnseesseessessseesuessessuessecsuessnessneesneessessessees 36 12 7 PISS os secacsvescpex tects zzasnraseesancads ccaseeasdtencscoaenaanacaoeieumtonusananiibaninniannuned amagadumaramnenmnalen 36 A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters 4 1 A cy zum mW zu vr p Foreword These Installation and Operating Instructions are applicable to devices of Series SGM Please follow all instructions and information given for installation operation inspection and maintenance The Instructions form a component part of the device and should be kept in an appropriate place accessible to the personnel in the vicinity of the location Where various plant components are operated together the operating instructions pertaining to the other devices should also be observed Kirchner und Tochter accepts no liability for any damage or interruptions of operation resulting from human error failure to comply with these Installation and Operating instructions improper performance of installation and repair work use of spare parts other than those from
11. Variable area flow meters Installation and Operating Instructions Variable area flow meters SGM Kirchner und Tochter A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters A rN JE AA u 4 Contents I Foreword Merete er ee tee te ee eet ete er Te ce Te O Brise ne eee d1 Symbolanemeaniidg 2er 2 2 General SAMY directi ns aenn rennen 23 Inendedless nenne een nee 2 4 Information for Operator and operating personndl eeeennennensnenn 2 5 Regulations and directives ueenenmennsnesensensensensennsnnsnensnnsnnsnnsnssnnsnsennnnnnnnnnnn 2 6 Notice as required by the hazardous materials directive nnnn 3 PA SPOUT And Storage Ar Ben Talente ae E 4 1 Declarations of conformity with EC Directives ennenennnenennneennsennnenn 42 ype SECS nennen 43 Deere 3 NStAllatlonsaneee ea 5 1 Preparation of the PIPSMIME sc asssicsaccssscsssasssccsscasernsssasecssansnecesseseszesssseccnsasseadssvacnaisasicesssseitenssenisnetacrsinsvass 52 Installation in the PUNE i asiccthiscecbanieastusianeecaacenadsiduivanstudtecaeasabiniecaluiaaisiaiceal tein delosiinledaivdevininedsin Bieta Us wece tsetse cea doa aR ARE N ARROEN O GI A E E TETEE 11 61 Measuring rang Serecicmesecierucriinrin e A E AEE 12 6 1 1 Version stainless steel unnennenemneenenneennneennsennnnenennenunnennnannensm
12. at stop Insert the circlip in the measuring part Re install the device in the pipeline ROMs 0 ol Caution An additional measuring error is to be expected unless recalibration is carried out A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters A N 34 F ww zu Vy yy p 12 2 Retrofitting a float damping system The complete retrofit kit consists of e 2 circlips 3 e 1 collet 4 yify e 1 damping cylinder with float stop 2 Vy Installation O Remove device from the pipeline Remove upper circlip 1 from measuring part Take upper float stop and float 5 out of the measuring part 4 Fasten circlip 3 in the lower groove on the float guide rod 5 Slide ceramic collet 4 on to the float guide rod and fasten with the circlip 3 in the upper groove 6 Insert float in the lower float guide in the measuring part 7 Install the supplied damping cylinder with integrated float stop 2 in the measuring part 8 Insert upper circlip 1 9 Re install device in the pipeline ons A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 12 3 12 4 Variable area flow meters A 35 hy 4 4 A
13. calibration If necessary the zero and the 100 value can be readjusted Loss of accuracy has to be expected Class 1 6 Class 2 5 8 4 2 Installing an ESK2A 1 Assembly is based on the plug in technique 2 Insert the push in lugs of the ESK2A under the two pins of the baseplate 1 3 Using slight pressure press the ESK2A on to the spring bolt 2 until it locks into place and fastens the ESK A securely 4 When the ESK A is retrofitted the fixing strap 3 is automatically pushed out and can be removed 8 4 3 Replacing an ESK2A 1 Replacement of the EM requires recalibration if compliance with the accuracy class is required Without recalibration loss of accuracy has to be expected Class 1 6 Llass 2 5 2 The calibration data are stored in the memory module used 3 Disconnect the EM from supply 4 Use a screwdriver to lever up the EM and pull it out 8 4 4 Setting the zero and 100 value on the EM The zero and the 100 value can be set on the ESK2A by means of built in pushbuttons When the pushbutton behind the 4 is depressed for longer than 5 seconds the measured value will skip to 4mA The ESK2A is then in the zero adjustment mode Optionally press button 4 for downward correction or button 20 for upward correction until the zero amounts to exactly 4 00mA In the same way the 100 value can be set when pushbutton 20 is held pressed for more than 5 seconds If no button is pressed f
14. ctor 4 terminal 5 terminal socket 7 1 Electrical connection Remove the housing cover of the indicator part to connect the plug in contact unit The terminals 4 are of the plug in type and can be detached for connecting the cables The built in contact types are specified on the indicator nameplate SC3 5 NO Y limit contacts in 2 wire technology are connected in conformity with DIN EN 50227 NAMUR SB3 5 E2 limit contacts in 3 wire technology require a supply power of 10 to 30 V DC They can be connected direct to a PLC control system A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters 1 4 I tk bo 2 wire limit switch SC3 5 NO Y NAMUR 3 wire limit switch SB3 5 E2 Terminal connection min contact Terminal connection max contact 3 wire load NAMUR isolated switching amplifier QGQOe QOOb00 3 wire power supply Electrical connection of limit contact in 2 wire technology Terminal assignment Contact for SC3 5 NO Y Plug colour Labelling 2 wire technology Electrical connection of limit contact in 3 wire technology Terminal assignment Contact for SB3 5 E2 Plug colour Labelling 3 wire technology A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt
15. d be avoided when surfaces e g viewing window are cleaned A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters A N 3E 33 ww zu VY Ey p 12 Service retrofits and conversions All devices with defects or deficiencies should be sent direct to our repair department To enable our customer service facility to deal with complaints and repairs as quickly as possible we would kindly request you to coordinate the return of devices with our sales department Tel 49 0 2065 96090 The variable area flow meter with indicator part can be retrofitted with a number of components e float float damping system eddy current brake contacts ESK A when indicator ordered with EM preparation totalizer EMZ Retrofitting of the EM PA can only be carried out by means of a recalibration An assembly kit is also available to enable the SGM device to be converted to a high temperature version 12 1 Replacement of the float Remove the device from the pipeline Remove the upper circlip from the measuring part Remove upper float stop and float from the measuring part Insert new float into the centre hole in the lower float stop and place it together with the upper float stop in the measuring part Note that the upper float guide rod must be guided through the centre hole of the flo
16. d for gas measurements A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters 12 6 1 Measuring ranges 6 1 1 Version stainless steel Stainless steel float Size Water Pressur Air Pressure e drop drop Yh mbar m3 hi N mbar 15 172 2 5 25 26 0 065 0 65 21 4 0 40 26 0 1 1 21 6 3 63 26 0 15 1 5 21 10 100 26 0 22 2 2 21 16 160 26 0 36 3 6 21 25 250 26 0 55 5 5 21 40 400 28 1 0 10 21 63 630 32 14 14 22 100 1000 50 1 8 18 38 2 8 28 50 25 1 63 630 32 14 14 24 100 1000 33 2 2 22 24 160 1600 34 3 5 35 25 250 2500 38 5 0 50 26 400 4000 45 8 0 80 30 630 6300 103 11 0 110 78 17 0 170 103 50 2 630 6300 74 8 0 80 13 1000 10000 77 11 0 110 13 1600 16000 84 15 0 150 13 2500 25000 104 23 0 230 60 35 0 350 69 60 0 600 104 80 3 2500 25000 68 35 0 350 16 4000 40000 89 40 0 400 16 100 4 6300 63000 120 10000 100000 220 Devices used for gas measurement float damping system recommended 1 LN at STP 0 C and 1 013 bar abs 2 300mbar with damping system A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters A A
17. e Version 1 7 SGM IK1 EM EEx SGM IK2 EM EEx Variable area flow meters EN za p en je wa WW a D A Type series SGM All metal device SGM EM with electrical signal output SGM EMZ with electrical signal output and totalizer SGM IK1 with one inductive contact SC3 5 NO Y SGM IK2 with two inductive contacts SC3 5 NO Y SGM IKS1 with one electronic contact SB3 5 E2 SGM IKS2 with two electronic contacts SB3 5 E2 SGM IK1 EM with one inductive contact and with electrical signal output SGM IK1 EMZ with one inductive contact and with electrical signal output and totalizer SGM IK2 EM with two inductive contacts and with electrical signal output SGM IK2 EMZ with two inductive contacts and with electrical signal output and totalizer SGM IKS1 EM with one electronic contact and with electrical signal output SGM IKS1 EMZ with one electronic contact and with electrical signal output and totalizer SGM IKS2 EM with two electronic contacts and with electrical signal output SGM IKS2 EMZ with two electronic contacts and with electrical signal output and totalizer SGM EEx all metal device explosion proof design SGM EM EEx with electrical signal output explosion proof design SGM IK1 EEx with one inductive contact explosion proof design SGM IK2 EEx with two inductive contacts explosion proof design with one inductive contact and with electrical signal output explosion proof design with two inductive contacts and with
18. e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters Technical data SGM N N w y ay 4 Accuracy class Standard VA C4 alt PTFE ceramics Indicator part Scale Scale length Turndown ratio Type of protection indicator part Version SS Allowable working pressure DN 15 DN 25 DN 50 DN 80 DN 100 Version PTFE Allowable working pressure Connections 1 6 to VDE VDI 3513 2 5 to VDE VDI 3513 in physical units e g h m3 h 30 mm 1 10 IP 67 NEMA 4X PN 40 PN 16 same as SS version Flanges to DIN 2501 EN 1092 1 On request ANSI B 16 5 JIS DIN 11851 threaded pipe joint to ISO 228 A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters A 15 A y Ey lt 4 6 4 Dimensions and weights 181 250 MARN h d 6 4 1 Version stainless steel with flanged connection Dim Weight kg DN PN L A B Bd DIN flanges with heating 15 40 250 70 5 107 20 35 48 25 40 250 70 5 119 32 5 0 6 7 50 40 250 57 5 132 65 8 2 10 4 80 16 250 57 5 148 89 12 2 14 0 100 16 250 57 5 158 114 140 16 6 Overall length for devices with female thread to ISO 228 300 mm to ANSI B 16 5 from 3 300lb
19. e the half round 3 encloses the pointer spindle ROM The terminals of the plug in contact unit are of the plug in type and can be detached for connection of the cables To comply with the IP degree of protection please consult the directions given in Section 8 1 Retrofitting a second contact The retrofit kit consists of the required contact pointer and integrated contact The connecting cable is fitted with the integrally moulded plug To install it may be necessary to unplug the flow totalizer first 1 Unplug the contact unit from the module rack 4 2 Remove locking screw 1 Caution Spring 2 is under pressure 5 Assemble contact pointers 4 slide rings 3 3 u ees spring 2 and locking screw as shown in the drawing gt 6 The second ring Item 3 is already provided EEE eee 5 in the version with one contact 7 Insert plug connector of the contact blue ie 6 into the socket on the circuit board 8 Plug in and connect up the contact unit A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters A N 3E 21 wa VY Ey lt 4 8 Electrical signal output SGM EM 8 1 The indicator part of the SGM EM with the ESK2A module supplies a current of 4 to 20 mA in two wire connection that is proportional to the instantaneous
20. eseenmmnmnsnnsennsensnnsnnennennsnnsnnsnennans 23 8 4 Installation replacement ESK2 A aaan 24 8 4 1 ESK 2A as replacement u innneunnenhenininiere 24 8 4 2 lastalling an ESKA incinin a E TO 24 8 4 3 Replacing an BORSA innen 24 8 4 4 Setting the zero and 100 value on the EM 24 8 4 5 Retrofitting an ESK 2A and its eallbration ana nenn nnnt 25 8 4 6 Changes and conversion ESK2A eiieeii 25 8 5 Hart communication with the EsKeR nee 26 9 Electrical signal output EM PA Prafibli iaaankine 27 9 1 B G lE ee ee ee Deere 27 Je ShieldingandiearthiNgenesnscsnniauun ann T aE 27 g3 PROFRIBUS PA Sonneetlian aaun ee E E mauris 27 9 4 Technical data EM PA sisssssssistsasscsasssassissasantatsasssssssnssbisisnendsdiesssnsscndsthitcesudnleaselpiscedsnapaentbah cnbstuentanbeade 28 9 4 1 HardWare einander 28 9 4 2 SSTA IEE nennen E ee pemer IES 28 10 Flow totalizer EM auseinander 29 10 1 ElBetfiealzonfieetan een 29 10 2 Settings display Mode unnnenennsennaenssennaennonnnnsnannsnnsnaanunnsnunnunnnennnannnunnnensneusnansnennaenaennaannennnnnnnnn 30 10 3 Technical data totalizer EMZ na 32 11 Maintenance and cleaning of the flow MetED cccsssssssssssssesssesssesssesssessnsssnessnessueesssesssesssesssesess 32 12 Service retrofits and conversions ueneeeennennnennneensennneennnnennsennannennenannennnnennnannnnnnnn 33 12 1 Replacement of theTtloak n een 33 12 2 Retrofitting a float damping SyYSteM h nrnna aaa 34 12 3
21. flow value gt 20 8 mA for alarm status Power effect lt 0 1 Ext resistance dependence lt 0 1 Temperature effect lt 5uA K Max ext resistance load 250 to 800 ohms Ambient temperature 25 C 60 C These values are to be conformed to as minimum values in the case of HART communication Self monitoring diagnostics Setting up operation as well as operation there are several cyclic diagnostic functions to get operational reliability An error detection generates an output signal high of gt 21 mA Additional information are given via HART command 48 Information and warnings will not generate an error output current Diagnostic functions control e Plausibility of FRAM data e Plausibility of ROM data e Working range of internal reference voltages e Signal detection of the measuring range of the magnet sensors e Temperature compensation of the magnet sensors e Calibration corresponding the application e Plausibility of counting value e Plausibility of physical unit and selected unit A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters Ama 24 za nm Gey ay p 8 4 Installation replacement ESK2A 8 4 1 ESK2A as replacement The ESK2A has been standardized by the factory so that e g a replacement can be carried out without requiring re
22. irective PED 97 23 EC Notice as required by the hazardous materials directive In accordance with the law concerning handling of waste critical waste and the hazardous materials directive general duty to protect we would point out that all flow meters returned to Kirchner und Tochter for repair are required to be free from any and all hazardous substances alkaline solutions acids solvents etc Make sure that devices are thoroughly rinsed out to neutralize hazardous substances 3 Transport and storage The SGM device is packed by the factory in packaging appropriate for transportation and storage Transport and storage should be carried out solely in the original packaging Protect the device against rough handling impact jolts etc A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters Ama 6 3E vn a 4 General 4 1 Declarations of conformity with EC Directives The variable area flow meter SGM meets all requirements of the EC Directives applicable to the product e EMC Directive 89 336 EEC e EN 61826 03 1997 A1 04 1998 A2 03 2001 e ATEX 94 9 EC EN 50014 1997 A1 A2 EN 50020 1994 e DGRL 97 23 EC A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web d
23. lstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters 22 8 2 A A p en mw ay Wy ay p Electrical connection SGM EM The connection terminals of the ESK2A module in the SGM EM indicator part are of plug in design and can be removed to connect up the cables Terminal connection pluggable lt 2 5 mm Type of connection 2 wire Current sink polarity reversal protection only for connection to extra low voltage according to SELV or PELV Peat zitan VOR A 240 200 Ohm THART Fr J Be careful by conceptual design in connection with other instruments e g supply units or process control engineering lt is possible that internal connection of ground earth connections or equipotential bonding will generate voltage drops which leads to malfunction of the instrument For this case a signal processor is required Connections at hazardous locations Before installation at hazardous location read the Supplementary Installation and Operating Instruction A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 8 3 8 3 1 Variable area flow meters A N 3E 23 ww zu VY Ey p Technical data ESKOA Power supply 24 V Dc Measuring signal 4 to 20 mA for O to 100
24. ment On no account should the VA flow meter be used to pull the ends of the pipeline together stress free installation 5 2 Installation in the pipeline 1 2 3 Check that the device is free from solid foreign bodies Use bolts and gaskets to be provided by customer in keeping with the pressure rating of the connection flanges and the operating pressure The inside diameter of the flanges differs from standard dimensions Flange gaskets standard DIN 2690 can be applied without restriction Align gaskets tighten nuts with the torques relevant to the appropriate pressure rating A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters 10 For measuring parts with PTFE liner and for measuring parts with ceramic liner and PTFE sealing face tighten the flange bolts with the following max torques Stud bolts DIN 2501 ANSIB 16 5 DIN ANSI 150 Ibs 300 Ibs 150 300 4xM 12 25 40 1 150 300 4xM 12 4x5 8 50 40 2 150 300 4xM 16 4x5 8 8x 5 8 80 16 3 150 300 8xM16 4x5 8 Bx 100 16 4 150 300 8xM 16 8x 5 8 On PN m be I Nm mir Nm Hr 15 40 150 800 98 71 52 38 25 40 1 150 300 21 15 10 720 50140 z 1507800 67 at at 80 oo ea 1807300 Ha7 bas E A Kirchne
25. nannennnnnnnen 12 6 1 2 Version PTFE 7 Ceramiesssnsn ae ER 13 62 Maenner nee 13 See Technicaldata SEM ae een 14 6 4 DIMENSIONS and WEIGHKG cesscessssssecsssssssssssesssesssssssssssssssessnsssnsssnsssnsssnsssssssssssssssasesssesessecesscesss 15 6 4 1 Version stainless steel with flanged connection 15 6 4 2 Version PTFE Ceramics with flanged connection 15 6 4 3 Version stainless steel with female thread connection 1 16 7 Plug in contact unit IK1 IK2 IKS 1 IKS2 nennen ana 16 41 Eleeiniealeonnseiinnee ca 16 7 2 Setting the limit value nnenssnseseenseenseenseenseenseensnnsnensensnenseensnonsnnnnennensnennenseonseenneenennn 18 7 3 Switching contact definition eek 18 7 3 1 TESChHleEalelab une ee sans 19 7 3 2 feria ete lym 2 ee ne ee a ae 19 74 NSS nen ana ee ne reiten 20 7 5 Retrofitting a second CONTACT a under 20 Kirchner und Tochter A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters 3 8 El ctrical signal output BEN EN sssisatinsiletsiaininndnsnantainieiiusidnsnameinikeohininianiindGe 21 8 1 Compliance with IP degree of protection nennen 21 8 2 Electrical connection SGM EM sspsnisisscixueajeunesspsabenonpinwnengununensactactenanebenaienebspanasinainbeapinuae gantcatine De 8 3 Technicaldata ESKA ande 23 8 3 1 Self monitoring diagnostics eeee
26. onding conductor should be connected to the device if necessary via the outer earth U clamp terminal of the indicator part Bus A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters 28 9 4 Technical data EM PA 9 4 1 Hardware to IEC 1158 2 and the FISCO Model 9 to 32 V DC Physics Supply voltage via 2 wire Bus connection Base current Starting current FDE Accuracy to VDI VDE 3513 Measured value resolution Temperature effect 12 mA lt base current lt 18 MA 1 6 lt 0 1 of upper range value lt 0 05 K of upper range value 9 4 2 Software GSD device master file supplied on diskette Device profile complete realization of Profile B V3 0 Function blocks Flow AIQ optionally for volume or mass flow rate Default units Qv m3 h Qm kg h Volumetric meter default unit m3 Mass flow default unit kg 0 126 default 126 set slave address is supported Service_Access_Points 1 Device Description DD for PDM via Profibus PA no local operator control Totalizer TOTO Totalizer TOT 1 Address range SAP s DD Operator control A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meter
27. or 10 seconds the ESK2A will automatically go to its measuring mode and include the corrections made These corrections are stored and remain valid even when the ESK A is switched off These settings have no effect on the linearity of measurement A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 8 4 5 8 4 6 Variable area flow meters A N 3E 25 ww zu VY Ey p Retrofitting an ESK2A and its calibration Retrofitting is only possible if the indicator had been supplied with EM preparation The required calibration data are specified on the indicator cover To carry out linearization requires the conversion program KroVaCal and a HART modem that is connected to the serial interface of the PC Linearization of the ESK 2A is carried out in 3 steps e Recording of the measuring points e _ Linearization of the characteristic by means of the PC e Storage of the linearization data in the EEPROM via the serial interface Recording of measuring points Recording of the measuring points should be carried out at the main scale marks in order to obtain the best possible linearization result These points can be approached in three different ways dynamic setting setting the flow value original medium or a reference medium established by conversion static setting lifting up the float not the pointer
28. otalizer Module rack Indicator part optionally stainless steel A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters g za z 3E 9 za I E y a p 5 Installation 9 1 Preparation of the pipeline Check the direction of flow in the pipe at the installation point of the flow meter VA flow meters are as a rule only suitable for vertical installation with the direction of flow being from bottom to top For all other installation situations appropriate pipe bends need to be fitted in the existing pipeline to ensure vertical flow through the device from below Straight unimpeded pipe runs should have a length equal to 5x DN upstream and 3x DN downstream of the installation location Any control equipment particularly in the case of gaseous media should always be installed downstream of the flow meter Refer also to Guideline VDE VDI 3513 Sheet 3 The SGM type series can as a special version optionally be constructed for horizontal installation If necessary support the ends of the pipeline to prevent vibration from being transmitted to the flow meter Clean by blowing or flushing out the pipes leading to the device before connecting up Prepare the installation point before starting to mount the flow meter Make sure the sealing faces are correctly spaced apart and in true align
29. r amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters J 7 E 4 4 A 6 Start up A minimum operating pressure inlet pressure is necessary for operation of the device Process medium pressure drop operating pressure Liquids 1 2 Gases without damper 1 5 Gases with damper 1 2 Pressure drop see Flow Tables The device must be properly installed before it is started up 1 Test the device connections 2 To set the flow pressurize the pipes by slowly opening the shutoff valves On liquid service carefully evacuate the pipeline 3 Check that all components are leak tight and if necessary retighten threaded joints or screw connections Applies to gases in particular avoid pulsation of the medium Basically vary the flow with the aid of adjusting valves so that the float is not subjected to pressure surges e g from solenoid valves otherwise the measuring part could sustain damage Devices for flowmetering of gases can be equipped with a gas damping system to avoid possible float oscillation due to compression Should the float nevertheless tend to oscillate this can be remedied by installing a throttle valve or suitable aperture plate downstream of the device see Guideline VDE VDI 3513 Sheet 3 A float damping system is recommende
30. s A N 3E 29 _ E y a p 10 Flow totalizer EMZ A 10 1 The flow totalizer EMZ in 3 wire technology can be built into the indicator part in combination with the electrical current output EM The flow totalizer EMZ is not suitable for hazardous environments A 6 digit display indicates the total flow value and can be switched over to the instantaneous flow value in O 100 Supply 11 12 and current loop 12 13 are not galvanically separated If the current loop is not needed a shorting jumper has to be connected to terminals 12 13 4 20mA ESK A galvanically separated pulse output P and P supplies one pulse for every counter advance indicated If the pulse output is not needed its terminals may remain unused Data are saved automatically in the event of a power failure The flow totalizer has been factory set according to data specified in the order and requires no adjustment The conversion factor for the totalizer unless otherwise ordered is set relative to the measuring range so that the summated value in Liter m etc can be read directly Disney Tommen S y E Totalizing continues in the background Butong Summated value eg Litres or ms Standard 10 of 0100 Electrical connection The supply power required is a protective extra low voltage PELV to VDE 0100 Part 410 All instruments recorders indicators etc connected to the measuring circuit are connected in series and may not exceed
31. s 300 mm 6 4 2 Version PTFE ceramics with flanged connection Dim DN PN L A B Bd Weight kg DIN flanges 15 40 250 70 5 107 20 35 25 40 250 70 5 119 32 5 0 50 40 250 57 5 132 65 10 0 80 16 250 57 5 148 89 13 0 100 16 250 57 5 158 114 15 0 1 PTFE only Overall length for devices with female thread to ISO 228 300 mm to ANSI B 16 5 from 3 300lbs 300 mm A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters A iN 16 a t d i y a lt 4 6 4 3 Version stainless steel with female thread connection Dim DN G L A B Bd Weight kg 15 G 300 70 5 107 20 3 5 15 Yo NPT 300 70 5 107 20 3 5 15 3 4 NPT 300 70 5 107 20 3 5 15 G1 300 70 5 107 20 3 5 25 G1 300 70 5 119 32 5 0 25 1 NPT 300 70 5 119 32 5 0 7 Plug in contact unit IK1 IK2 IKS1 IKS2 The VA flow meter SGM can be equipped with a maximum of two electronic contacts The contact operates with a slot type initiator which is actuated inductively by the half round metal vane on the measuring pointer 4 The switching points are set by means of a contact pointer the position of the contact pointer at the same time serving to visually indicate the set limit value Contact types SC3 5 NO Y 2 wire technology NAMUR 1 limit contact SB3 5 E2 3 wire technology 2 contact pointer 3 plug conne
32. selstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7
33. ted up as shown in the drawing above It can optionally be operated via the power terminals of the ESK2A 2 or via a series connected external resistor 1 When the ESK A is operated together with the totalizer HART communication is possible in accordance with the following wiring diagram The totalizer itself cannot be read or operated by means of the HART communication A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters A 3E 27 qi D A 9 Electrical signal output EM PA Profibus 9 1 9 2 9 3 Bus cable The definitions of the FISCO Model apply only provided the bus cable used conforms to the following specifications R 15 150 Ohm km L 0 4 1 mH km C 80 200 nF km Shielding and earthing For optimum electromagnetic compatibility of systems it is extremely important for the system components and particularly the bus cables connecting up the components to be shielded and that electrically speaking and if at all possible these shields form a continuous envelope PROFIBUS PA connection For connection of the bus cable see Figure on the right Connect the cable cores to D and DL polarity reversal has no effect The cable shield should be connected with minimal length to the functional earth FE The equipotential b
34. ters 32 10 3 11 A zu Bu zum mW zu vr p Technical data totalizer EMZ Auxiliary power Rext current loop Power consumption Max external resistance load Pulse output Auxiliary power Max current Max power loss Ton T off Uon U off Pulse value Ambient temperature Indication error 24 V DC 0 600 ohms max 2 W 0 to 720 ohms dependent on supply voltage terminal P P 24 V DC 50 mA 250 mW fixed pulse width 80 ms dependent on flow Ub 3V DV 1 pulse 1 display totalizer advance 1 flow unit 1 Litre 1 m 25 C to 65 C lt 1 of value indicated one display unit at maximum Maintenance and cleaning of the flow meter Within the scope of routine operational maintenance of the plant and the pipelines the flow meter should also be inspected for dirt accumulation signs of corrosive wear mechanical wear and damage to the measuring tube and the indicator We recommend that inspections be carried out at least once a year To clean the device it must be removed from the pipeline Attention A Pressurized pipes to be depressurized before removing the measuring part In connection with devices used for flow measurement of aggressive media appropriate safety precautions should be taken in regard to residual liquids in the measuring part New gaskets should always be used when the measuring part is reinstalled in the pipeline Electrostatic charges shoul
35. th the conversion factor based on the measuring range Installation 1 Slide out the existing scale 2 Slide the flow totalizer unit on to the middle rail of the module rack 3 Then slide the new scale into the module rack 4 While sliding over the totalizer display lift the scale slightly until the scale cutout forms a frame around the totalizer display A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters 36 _ N N 4 A 12 5 High temperature version indicator part Items supplied 4 e 1 no sealing ring 1 Ss e 3 nos fastening screws 2 4 2 e 1 no HT extension 3 e 2 nos distance bolts 4 5 12 5 1 Installation as The device can remain in the pipeline Magnet 1 Note pointer position before removing indicator Sealing ring 2 Detach both nuts fastening the indicator 3 Remove indicator with its fastening clips from the measuring part Remove plastic cap from HT extension Position ring 1 exactly in the groove on the HT extension Fasten HT extension with the three screws 2 to reverse side of indicator Screw distance bolts 4 to the threaded pin on measuring part and tighten down width A F 14 mm oof N 12 6 Mounting the indicator Position the indicator with fastening clips on the distance
36. the max external resistance of 720 ohms The supply voltage Us of max 30 VDC is connected to terminals 11 and 12 at the totalizer module A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters 30 10 2 When galvanically separated current evaluation modules PLC are used at terminals 12 18 the supply power 11 12 should not be earthed When the EM signal is needed only for the totalizer a shorting jumper is required at terminal 12 13 Settings display mode Reset Deletes the stored summated value Button 1 1 h flow Example in with decimal point and one decimal place Button 2 totalizing Example b H G U counter without decimal points Taste 3 ho og conversion factor Example a The first two decimal points light up Conversion factor The conversion factor is factory set and always based on the measuring range so that the current summated value can be read out at any time Conversion factor 10 of the full scale range This allows the summated value to be read from the display directly 1 1 If the measuring range is not known e g spare parts delivery a conversion factor of 1000 is factory set If a change or correction to the conversion factor is necessary this factor can be changed by pressing Button 2 at the moment the supply voltage is switched on
37. the original manufacturers or use of the SGM devices other than for the intended purpose 2 Safety 2 1 2 2 2 3 Symbol and meaning A Safety notice This safety notice can be found at all hints on work safety in these assembly and operating instructions pointing out hazards for life and limb of persons Further this safety notice highlights safety hints in these operating instructions that point to regulations guidelines or operating sequences that must be observed without fail Non observance may result in damages to or a destruction of the variable area flow meters and or other parts of the installation General safty directions These Installation and Operating Instructions contain basic instructions for the installation operation inspection and maintenance of the flow meter Failure to comply with these Instructions or improperly executed installation wiring and repair work can lead to serious faults in the plant giving rise to hazardous situations for man and beast as well as damage to property The operator is required to rule out potentially hazardous situations through voltage and released media energy Intended use The SGM devices are designed and intended for measuring the flow of compressible and incompressible fluids They may only be installed between flanges in the pipeline Select the SGM device model on the basis of the nominal diameter and nominal pressure at the site and also the kind of fluid product
38. until the pointer indicates the main scale value For all approached measuring points both the respective flow value and also the associated current value of the ESK2A should be noted down Changes and conversion ESK2A If any change is required to the measuring range the process temperature the process medium the density the viscosity or the pressure this can be carried out by Kirchner und Tochter A Kirchner amp Tochter GmbH Dieselstra e 17 D 47228 Duisburg Fon 49 2065 9609 0 Fax 49 2065 9609 22 Internet www kt web de e mail info kt web de Version 1 7 Variable area flow meters 26 8 5 A zu Bu zum mW zu vr p Hart communication with the ESK2A HART communication is not obligatory in order to operate the ESK2A If HART communication is carried out with the EM it will in no way affect the analog transmission of measured values 4 20mA HART Protocol revision 5 9 Exception in multidrop operation In multidrop operation a maximum of 15 devices with HART function can be operated in parallel their current outputs being switched to the inactive state I approx 4mA HART communicator Where a HART communicator Type Fisher Rosemount Model 275 or a PC with HART modem is used the series connected resistance Rext must be greater than 250 ohms In this mode the supply power should be a minimum of 18 V The communicator or PC whichever is applicable is connec

Download Pdf Manuals

image

Related Search

Related Contents

Philips Cordless telephone DECT1223S    Solara Field Tracker 2100  CATALOGUE NICE - Implant dentaire, AlphaBio Tec  Entretiens des arts plastiques 5 mai 2011 Thème général : la presse  Fog Jet User Manual  Keys Fitness 550 Upright User's Manual  USER MANUAL  sekonic L478 flyer FR (no c&b) - KELVIN  チャイルドシートの購入費用を補助します  