Home
Description Operating Instructions
Contents
1. a ii i ee eee eee ee 18 2 FEH GmbH D 48432 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de 3 FEH GmbH D 48432 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de Multiject Hygienic Beds 2 Introduction Most valuable Customer let us express our special thanks to you for your confidence in our highly innovative product You have purchased a product that meets high medical and qualitative standards It fulfils the basic requirements according to DIN EN 1970 s App of 11DD 93 42 EWG EN 60601 1 A1 A2 and EN 60601 1 2 38 These Operating Instructions are part of the product and contain important startup and general information Please read it carefully before commissioning and contact our technical helpdesk with questions that might arise In case of sharing this product with third parties please make sure that these operating instructions are passed too The operating instructions should be stored in a manner that makes them quickly accessible Due to the multifunctionality of the product we strongly suggest instructions held by qualified health personnel prior to deployment of certain medical applications Technical modifications of the product may not be made Neglect may affect the products performance thus resulting in a possible exclusion of product liability by the Multilect GmbH Warrant
2. 7 000 E Mail Zentrale feh med de 18 FEH GmbH D 48432 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de mm
3. Maintenance and Cleaning You can wash the fabric in a washing machine with temperatures up to 95 C The fabric can be treated with every standard cleaning and disinfecting agent With the fabric removed the basin and the framework can be cleaned with standard cleaning or disinfesting agent You may not use a steam blaster or pressure washer Clean the mobile tank regularly to prevent impurities odours and bacterial development You can pour an additive into the waste water We recommend among others the product Micropur Classic skin compatible and tasteless available on the market The use of additives is dependant on the recommendations of its facturers The fan heater CZ 502 E shall only be cleaned with a dry cloth do not use water and make sure that the fan heater is turned off 15 FEH GmbH D 48432 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de mm Multiject Hygienic Beds Technical Data Nursing Hospital bed CI Type Multilect Serial Number Date of Manufacture l refer to the type plate Production Number Safe Workload 135 kg Lying Surface 200 x 90 cm Outer Dimensions 220 x 96 cm Lying Height 7 cm Lying Surface from the horizontal to the vertical motorized adjustable Control Motor Type of Drive individual drive Protection Class 1 Degree of Protection IP 44 Motor Voltage 24 V DC Operating Mode intermi
4. _Multilect UAE LILLE LLILLLLLA nn T m m Description Operating Instructions Multiject Hygienic Beds 1 Table of Contents 1 lasleorCONENIS ea oso E ee ae eee E 2 2 AN OC U M E E ES 3 O OUT DES TIP UO PR pm e E EEE 4 Ei ELS Ol AO OIG ATOM ere m TE E 4 ARS alely GUIGSIINGS osiris ip e TOONE E r 5 3 Instructions tor USE i E EEE nn T 5 1 Operation Readiness cara sacasaaarasdraacsavnesnteceaneeieciaesdnaataesdnteaneensqanseeasadenaareabearaedaa T 9 2 MOVNO Ne NUFSMO BEQ sz saa ete tenka acess da keto borio EEE ENER aia Ba aaa ot DO F ADC o e E 8 Fk AICO Me F ADC E ee en AE 8 332 REMOVING NG F ADTIO o osi ed o r e eee ae 10 5 3 3 Sheet with Velcro Fastener ana Re R ee ee ee ee ee ee ee ee ee ee e ee e eo kao enne 10 54 lll ONdNONINO esses oero naoko a OEEO 11 5 5 Raising the Lying Surface o sis ae Re Re ee ee ee koe ee ee dido dasaka saa onaj anita 12 30 VOL CG GH AUCH enese 13 5 6 1 Mounting for Safety Belts see sele aaa kaaa aaa kaaa aaa aka akan 13 202 DAG Sl UNG m e vra 13 5 7 Mobile Shower Multilect SK aaa akan 14 5 8 Water Collection and Drainage aaaaa kakaa kakaa kakaa kaaa kaaa aaa kaaa 15 5 9 Maintenance and Cleaning oa eena ee ee kakaa oka oka oka kaaa kaaa 15 GO NeenmcaL Da seas o evi asia E odsada NOP NPR NOVA 16 7 Multilect Accessories Spare PartsS aaaaaa naka aaa aka kaaa aaa aka aka kaaa aka aaa kakaa 17 O CONAC oro av o i
5. age the product In no case may the bed be treated with a steam blaster or pressure washer Disinfectants or germicides used shall be diluted according to the instructions given by the manufacturer of the product The application of mattresses is not intended Therefore no mattresses shall be applied to the bed Any disregard for safety regulations may cause personal or material damage Hygienic Beds _Multilect 5 Instructions for Use 5 1 Operation Readiness Pi The Multilect bed has to be fixed at the place of destination For Fixation of the nursing bed three of the four wheels have a break which can be fixed by pressing with the foot Direction Wheel You recognize the wheels with breaks by the light coloured locking levers the wheel with the m dark locking lever is a directionwheel cf Fig 5 1 If needed the wheels can be released by bringing the locking lever into a horizontal position Wheel w Brake Figure 5 1 5 2 Moving the Nursing Bed i Situated by the head of the bed on the left you JE find the directionwheel with dark locker level Fix it pressing with the foot cf Fig 5 2 With the directionwheel fixed the bed can be moved by one person without the risk of drifting out of track gt By bringing the lever into horizontal position you gt ae release the fixation in longitudinal direction Figure 5 2 7 FEH GmbH D 48432 Rheine Am Stadtwald
6. and down to the tension spindle The tension spindle itself shall be positioned by means of the crank by the head end of the nursing bed in that way that the notch for intake of the piper points outward viewed from the foot end in 3 o clock position cf Fig 9 11 Figure 5 10 At the blue marking the notch is widened to approx five cm in length to intake the piper here First insert the lower end and pull it up to the foot end Then insert the piper from the upper end and pull down to the head end Now the fabric can easily be tensioned with the crank turned in direction of the arrow spannen tension The fabric should be smoothed down from end to end of the ea a aa E a nursing bed now After the smoothing the Figure 9 11 fabric will be tensioned firmly for good you need to apply a force of approx 20 kg After tensioning the handle of the crank can be collapsed Now the bed is prepared for the patient 9 FEH GmbH D 48432 Rheine Am Stadtwalde 15 m Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de mm Multiject Hygienic Beds 5 Instructions for Use The fabric consists of a biocompatible material Should a patient be irritated because of the lack of a mattress the included sheet can provide the used bed feeling cf 5 3 3 Sheet with Velcro Fastener Fabric Removing the Fabric To remove the fabric first expand the crank s handle and release the lock of the c
7. atient can leave the bed without bending or twisting of the spine with only little help from the personnel using the foot end as standing board The motor for the adjustable inclination is maintenance free When lowering the lying surface make sure that you do not get into the area of the supports Danger of violent pressure within reach It is important to notify that a safety belt or a control cable will not reach into the area of supports where it could be clamped between support and lowering lying surface Children or infirm persons shall not use the adjustment device 12 FEH GmbH D 48432 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de mm Hygienic Beds Muitijeci 5 Instructions for Use Protecting the Patient Mounting for Safety Belts You can fix a patient with a safety belt which is not included as safety belts need to be patient oriented suited With it you gain stability even in upright position All over the lying surface may be used several safety belts Therefore a fixing slot is attached underneath the outer frame in the bed s entire length cf Fig 5 17 Additional fastening devices star knobs can be ordered as accessory Figure 5 17 Protecting the Patient safety Grating The safety grating left and right to the lying surface can be brought into safety position using the permanently mounted guide rails You can release the gra
8. e 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de mm _Multilect Hygienic Beds 5 Instructions for Use Fabric Attaching the Fabric Figure 5 3 Figure 5 4 The fabric is equipped with a piper by each long side to attach it Before attaching the fibre the guide rails are to be fixed in the upper position Watch out that the fabric is correctly positioned Along the pipers by the ends of the long side a velcro with different sizes of spacing toward the edge is attached cf Fig 5 3 and Fig 5 4 Figure 5 5 Figure 5 6 At the head end of the bed is a round piper cf Fig 5 5 through which the fabric with the plug in side here the velcro is close to the rim and the velcro will be inserted inwards into the guidance provided cf Fig 5 6 8 FEH GmbH D 48432 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de mm Hygienic Beds Multiject 5 Instructions for Use pr 5 i U E u r mali PLi oe im mad ET eT ee a g SE Si m Figure 5 7 Figure 5 8 After inserting the piper cf Fig 5 7 the fabric will be pushed up to the blue marking approx 70 cm before the foot end of the nursing bed cf Fig 5 8 Then it will be pulled through under the guide rail cf Fig 5 9 to the other side of the nursing bed where the fabric in turn will be pulled through under the guide rail cf Fig 5 10
9. ent Decubitus prophylaxis or moist decubitus treatment if necessary are supported by controlled temperature regulated air supply from underneath the lying surface Support treatment options which require regulated heat supply Increase hospital s hygienic conditions Use the bed with frequently changing users of the bed as in hostels for the homeless or the like Multiject Hygienic Beds 4 Safety Guidelines In case of damages resulting from non compliance with these Operating Instructions the warranty is no longer valid The Multilect GmbH does not take any liability for consequential damages The Multilect Nursing Bed is not suitable for persons under the age of 12 This device may only be supplied with 230 Volts alternating current The electric circuit supplying the used socket is to be protected with at least 10 Amperes The mains plug may never be disconnected by pulling on the cable Repairs to the appliance especially the technical installations of the nursing bed may only be carried out by qualified personnel This product s electrical equipments are splash proof according to IP44 IPXO resp Therefore the intended use of the mobile shower unit is not associated with any danger Nevertheless the electric equipments should not be exposed to the spray of the shower directly Please remove other electrical devices such as radios etc from the closest range of the product before use of the mobile shower uni
10. ge The fan heater CZ 502 E is placed so that an accidental splash of water during or after showering the patient is prevented A sophisticated pipe system at the air outlet cf Fig 5 14 prevents shower water from getting into the fan heater However the shower should never be held directly over the fan heater situated underneath the Turning on the fan heater and setting the temperature is controlled with a control unit Pressing the button ON turns on the fan heater the button OFF turns it off in 1 steps later the device can be turned on again Figure 5 15 Multject Hygienic Beds 5 Instructions for Use Raising the Lying Surface Using the pivot hinge the control motor can raise the lying surface up to an inclination of approx 80 into a nearly vertical position Before raising the lying surface clear the tray at the foot end The tray serves mainly to provide a secure stand of the lying surface in upright position The control motor is handled by a manual control cf Fig 9 16 with integrated blocking function protection class IP 66 and a control unit protection class IP 44 With drawing the magnet key in arrow direction you can lock or unlock the raising function cf Fig 5 16 In unlocked mode a green control lamp lights aside the lock symbol up to 45 inclination after repeated release 45 to approx Figure 5 16 80 a yellow lamp Moved into nearly vertical position the p
11. he mobile shower unit Multilect SK at the fan heater directly While using the shower no electric apparatus shall be in reach of the nursing bed Make sure that the drain pipe of the collection basin of the Multilect nursing bed points directly into the opening of the mobile tank with the lid of it open Empty the mobile tank before showering to avoid an overflow of showering water Figure 5 20 Multiject Hygienic Beds 5 Instructions for Use Water Collection and Drainage You can wash or shower the patient in the Multilect nursing bed without any problems as often as the patient likes Water as well as body fluids pour through the fabric into the basin and through the drain into the mobile tank The mobile tank is placed on a fixed drawer and suited with an opening and two outlets Regularly empty the mobile tank especially after each showering Pull out the drawer on which the mobile tank is positioned at the foot end of the bed to take it out Close the lid and roll the tank to empty it in your shower for example To unscrew the caps of the two outlets bring the tank into a horizontal position lie flat on the floor You can put down the caps on the cap holders To drain lift the tank at the carrying handle into an upright position Close both outlets after draining After you brought the tank back to the drawer unscrew the lid of the opening before you push the tank until stop into the final position under the bed
12. rank by which the fabric has been tensioned with the crank turned with a force of approx 20 kg in arrow direction l sen release After half a turn in free speed the tension spindle starts spinning thus releasing the fabric The tension spindle is to be turned that far that the notch with the piper of the fabric inserted points outwards viewed from the foot end in 3 o clock position and the notch is freely accessible to pull out the piper Beginning at the blue marking you pull out the piper starting at the head end side With the piper released from the head end side you pull out the piper beginning at the foot end side for half the length You then turn to the head end on the left side of the bed and pull out halfway the piper of the plug in side backwards through the notch in the head end cf Fig 5 7 Now you can release the piper on the tension side fully and then pull out the piper on the plug in side totally A Never use the crank for tensioning and releasing the fabric with someone lying in the bed Fabric Sheet with Velcro Fastener The spread fabric has a velcro at both sides of the bed cf Fig 5 12 to attach the included sheet to it You will need the sheet only in exceptional cases f i eS to give the patient the used bed feeling during the Velcro Fastener phase of settling in if a mattress is missed 7 i f U y U _ Firstly the sheet can be spread like on common beds 1474 Afterwards align
13. t To avoid danger of slipping let no water drip on the floor For transport the brakes of the bed may be released For any other purposes the brakes have to be locked The guide rails are intended for securing the patient not for immobilization Disconnect the bed from current supply before cleaning or maintaining Make sure that electric supply is disconnected from the electric circuit before moving the bed The power cable or any component of the electric equipments might be damaged when used inappropriately Never use the product close to flammable gases or vapours 5 FEH GmbH D 48432 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de mm 6 FEH GmbH D 48432 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de Hygienic Beds Multiject 4 Safety Guidelines You need to activate or deactivate the various functions of the nursing bed as required Personal injuries might occur with unlocked wheel brakes in case of lying down or leaving the bed Do not expose the nursing bed to extreme climate conditions Material damages might be encountered The acceptable temperatures range from 40 C to 80 C Before moving the bed bring the lying surface to horizontal position and make sure the frequented surface s lateral slope is less than 5 Aggressive detergents solvents and washing agents may dam
14. the velcro fasteners on the fabric 47 with those on the sheet so that you can attach and stretch the sheet from one side head or foot end to the other Figure 5 12 10 FEH GmbH D 48432 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de mm 11 FEH GmbH D 48432 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de Hygienic Beds _Multiject Air Conditioning bed room temperature The fan heater CZ 502 E comes with a protection circuit to prevent overheating Should this occur the fan heater shall be turned off to let it cool down Some ten to 15 minutes With the fan heater turned on the temperature of the air flow Figure 5 14 can be regulated with the push buttons and between 20 C and 50 C The chosen temperature is displayed in a two digit display The display will show 0 when only the fan is running and supplying an air flow at 5 Instructions for Use The bed is equipped with a fan heater Type CZ 502 E cf Fig 5 13 The fan heater can be used as ventilation or together with the heating which can be adjusted in 1 steps between 20 C to 50 C The fan heater may be used in following situations A create a comfortable bed climate A dry the patient after the shower in bed A use in therapeutic measures which require a determined temperature or temperature ran
15. ting with the unlocking cf Fig 5 18 positioned in the middle of the lower grating Figure 5 15 13 FEH GmbH D 48432 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de mm 14 FEH GmbH D 48432 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de Hygienic Beds _Multilect 5 Instructions for Use Mobile Shower Multilect SK Figure 5 19 Spray only over the lying surface so that the water can flow through the fabric into the collection basin AN To avoid danger of slipping let no water drip on the floor Disconnect the 24 V plug after showering so that no free speed can damage the water pump The mobile shower unit Multilect SK cf Fig 5 19 comes with the Multilect nursing bed The service case of the mobile shower unit carries the shower hose with shower head and cable connection 24 V Fill the fresh water tank with tempered water and close the rotary lock of the fresh water tank tightly use the cover key if necessary Now you can roll the mobile shower unit to the Multilect nursing bed Take the shower hose with the shower head and the 24 Volts plug connection out of the service case cf Fig 5 20 The shower is ready for use after connecting the plug connection to the 24 Volts plug on the left side of the Multilect nursing bed You may not point the water spray of t
16. ttent duty 2 18 min Load Type compression tension Lift up to 425 mm Adjustment Load 6 000 N max Emergency Adjustment by rechargeable battery Adjustment Speed up to 8 mm sec Maintenance maintenance free Fan Heater CZ 502 E CE proof Control Degree of Protection IP 44 12 V Mobile Shower Unit Multilect SK Max Filling Quantity 24 litres Submersible Pump Installed 24 V 25 30 W Output 18 I min Pressure 1 bar Length of shower hose approx 1 65 m Length of 24 V Spiral Cable approx 3m 16 FEH GmbH D 48432 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de mm Hygienic Beds Mulliject Multilect Accessories Spare Parts Multilect Fabric Multilect Fitted Sheet Fan Heater CZ 502 E Mobile Shower Unit Multilect SK Safety Grating pair Multilect BE Star Knob pair for Attachment of Safety Belts and Tools Micro pur Classic cleaning agent 17 FEH GmbH D 48432 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de mm Hygienic Beds _Multifect Contact Produced by Multilect GmbH X Kortenkamp 5 M i D 48291 Telgte U DE Fon 49 25 04 98 03 73 Hygienic Beds Fax 49 25 04 98 03 50 E Mail info multilect de Distributed by FEH GmbH Medical Technical Products m D 48462 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 m Fax 49 59 71 8
17. y and guarantee will be granted in the context of legal provisions in the particular country of delivery temperature variable air flow perforated textile fabric 4 a a S da ia 2 fluid i al APNA on ng amp discharge open trough for receiving warm air supply body fluids and cleansing water 4 FEH GmbH D 48432 Rheine Am Stadtwalde 15 Fon 49 59 71 98 56 63 Fax 49 59 71 87 000 E Mail Kubitza feh med de Hygienic Beds _Multiject 3 Product Description The Multilect system is a mattress free patient positioning with the patient lying on an elastic fabric permeable to both air and fluids and washable in any common household washing machine with temperatures up to 95 C The included mobile shower unit makes washing or showering the patient in the bed possible The waste water flows over a collection basin placed under the lying surface into a mobile tank An adjustable airflow temperature assures a comfortable lying climate All of the lying surface can be raised progressively from horizontal to nearly vertical position with a handheld electronic control You can apply safety belts for immobilization of the patient The idea behind this lying surface implies no mattress to avoid molds mites and germs among others 3 1 Fields of Application Wash and shower the patient without moving the patient Bring the patient to the required vertical position with only little personnel deploym
Download Pdf Manuals