Home

Assembly and Operating Instructions Tubular - Becker

image

Contents

1. Move screen away from obstacle remove obstacle and move in the desired direction Tubular drive switched off automatically due to an obstacle when moving in the same di rection during last operation Faulty electrical connection Tubular drive in error mode obstacle detection faulty 4 Check electrical connection Reset end limit positions or replace tubular drive The tubular drive only responds after 5 sec onds Information for the Electrician Becker tubular drives with electronic limit switching can be parallel connected The maximum switching contact loading of the control device timer relay control switch etc must be observed Use external conductor L1 to control the up and down direction Other devices or consumption units lamps relays etc must not be directly connected to the drive connection cables For this purpose the drives and additional units must be decoupled by relay controls When installing the drive an all pole separation capability from the mains with at least 8mm contact opening width per pole must be provided EN 60335 Attention Only use mechanically or electrically locked switching elements with a marked zero position This also applies when drives with electronic and mechanical limit switching are used in the same system The changeover time for changing the running direction must be at least 0 5 s Switch and control must not execute simultane ous UP and DOWN commands To opera
2. e Position control devices within sight of the driven product at a height of over 1 5 m e Ensure that there is an adequate distance at least 40 cm between moving parts and adjacent objects e Nominal torque and duty cycle must be suitable for the requirements of the driven product e Technical data nominal torque and service life are located on the type plate of the tubular drive e Moving parts of drives intended to be installed at a height of less than 2 5 m above floor level or other access level need to be protected e Crushing or shearing points must be avoided or protected e Observe safety distances in accordance with DIN EN 294 e When installing the drive an all pole separation capability from the mains with at least 3 mm contact opening width per pole must be provided EN 60335 e Ifthe mains connection cable is damaged it may only be replaced by the manufacturer e Drives with a HOSVV F connection cable are only to be used inside the building ES AS hy AN ple Y NY BECKER 3 Assembly and Operating Instructions Designated use The tubular drives P5 20SE to P9 16SE and R8 17SE are to be used solely to operate screens with automatic locking In order to function correctly these tubular drives require a fixed end stop in the upper end limit position when screen is retracted Interlinked operation is only possible if all sub systems run exactly synchronously and reach the upper end limit at the same time
3. Other applications utilisation and modifications are not permitted in order to protect the safety of the users and others since these actions can impair the system s safety resulting in personal injuries and property damage Becker Antriebe shall not accept liability for damages arising from such actions Always observe the information in these instructions when operating or repairing the system Becker Antriebe shall not accept liability for damages resulting from incorrect usage Mounting and installation instructions Installing the tubular drive Caution All electrical connections must be made by a qualified elec trician The current supply must be disconnected before in stallation These installation instructions must be given to the electrician installing the equipment When installing the drive the following steps must be carried out 1 Fitting the drive adapter The drive adaptor is secured by a bearer plate To remove the drive adapt er unscrew screw and remove the bearer plate Fig 1 9 2 Fitting the drive adapter with safety catch P5 20SE to P9 16SE and R8 17SE The insert direction of the drive adaptor safety catch is prescribed by its shape When installing the drive adaptor always ensure that the safety catch engages A clicking sound can be heard when the drive adaptor safety SS catch engages properly Pull on the drive adaptor to check that it is located safety catch securely Fig 2 P5 20SE to P9
4. 16SE and R8 17SE self locking hole drive adaptor safety catch drive adaptor 3 3 Before inserting the drive into the tube measure the dimensions from the end of the tube to the centre of the drive adaptor and mark the dimensions on the tube Fig 3 al y P5 20SE P9 16SE Oe 40 mm plastic drive E dE 4 Round tubes with groove With some drive adaptors groove widths tolerances in different barrels can be compensated for by turning the drive adaptor into another groove recess These groove recesses have different dimensions and allow you to install the drive so that it fits exactly Fig 4 5 Round tubes Release the tube at the motor end to allow the cam of the limit ring adapter to be slid into the tube There must be no clearance between the cam of the limit ring adapter and the tube Fig 5 6 Mount the drive using a suitable limit ring adaptor A and drive adaptor B Slide the drive with pre mounted limit ring adaptor and drive adaptor into the tube into it connects positively Ensure that the limit ring adaptor and drive adaptor are fitted into the tube securely Fig 6 The drive adaptor of the tubular drive must be connected to the tube as fol lows Size of drive Tubes Y Torque max Fastening screws mm mm Nm for drivers 4 x flat headed sheet metal screw ST 4 8 x 10 DIN 7982 O45 Pe ea drive 50 flat headed sheet metal screw ST 6 3 x 10 DIN 7982 adapter Becker r
5. P5 20SE P5 30SE P9 16SE R8 17SE Tubular drives for screens with locking device forme Important in ee BECKER Assembly and Operating Instructions Contents is AS e o AA A o ER E O ES O deans 2 A e E e O o Pue tere aoe AI PTA 2 A O o PA A o PP E E E E E E 2 Designated US ra a o dai 4 Mounting and installation NS MUCHO Sarria vila init 4 Setting the end limit PO SS a A o e 6 Deleting the end limits using the setting controls sexrsriniocito erro i par T a rs aes 1100 eN o ha e a EE ATN EAE A TA IE EAE E A AE o E E ac 8 nformation for the Electrician ee concibe dai id tele a DR Ra aa Ran DD 8 I AAEM O carter ii ii de dad ques ade added ad decenal dean a E 9 SOI COMME CHOW cacareado cate 9 Introduction The screen drives P5 20SE to P9 16SE and R8 17SE are high quality products which offer a wide range of performance fea tures Optimised for screen applications with automatic locking No settings on drive No external limit stop switches Automatic compensation of changes in screen curtain temperature ageing humidity Optimum tensile load adjustment according to the mechanical requirements of the sun protection system Minimal curtain and seam strain Automatic detection of the upper end limit Automatic detection of the lower end limit when automatic locking function is active Right or left hand installation Parallel connection of several drives possible Suitable for all Becker control syst
6. ain and re programme end limit positions Tubular drive bypasses End limit positions deleted drive makes clack the end limit position or clack sound when switched on fails to reach the pre set end limit position Tubular drive stops at random and does not respond to control com mands for any direction The tubular drive does not move in the correct direction Short circuit in electrical connection due to dampness External loads connected to the connecting wires of the tubular drive L1 and N terminals mixed up due to long ca ble Tubular drive overloaded Sun protection system jammed too much friction The tubular drive has been previously in stalled Tubular drive overheated Faulty tubular drive no response even after considerable period of idle time Repair electrical connection Re programme system Check electrical connection Remove exter nal loads Re programme system Exchange L1 and N N bal L1 blk br Re programme system Use stronger tubular drive 2 Make sun protection system smooth run ning Delete end limit positions and re install Tubular drive will be ready for operation again after a few minutes Replace tubular drive Reset using the pro gramming button In this case no clack will be heard Tubular drive can be moved again in both directions using the setting control to allow the drive to be removed
7. ecommends that the thrust bearing also be connected to the tube Attention BL 78mm When drilling the tube ensure that you never drill in the area around the tubular drive When inserting the drive into the a tube do not drive it in or drop it into the tube Fig 3 and 6 11mm Secure the drive using Suitable fasteners for the given screen bearing The screen must be moved to the upper end limit towards a fixed end stop Always observe the relevant regulations for electrical installation Electrical connections must be made by a qualified electrician In order to programme the end limit positions connect matching coloured Becker setting control 4935 200 011 0 the Becker programming handset Item No 4901 001 158 0 or a standard knob operated rotary switch all of which do not allow the drive to be reset and switch on the power supply Fig 7 FU gt Ju Attention V The programming handset and the setting control are not in tended for permanent operation but should be used for initial operation only When installing the sun protection system always ensure that there is no risk of the motor connection cable being dam aged when the system is in operation EN Vy EN 5 AS EIN NY AA eS Assembly and Operating Instructions Setting the end limit positions RS Note Installation steps 1 2 First the screen must be moved to the upper end limit until the tubular drive switches itself off automaticall
8. ems Compatible with previous types of motor 4 wire connecting cable Always observe the information provided in these instructions when installing and setting the device Warranty Structural modifications and incorrect installation which are not in accordance with these and our other instructions can result in serious injuries e g crushing of limbs Therefore structural modifications should only be carried out with our prior approval and in accordance with our instructions particularly the information contained in these Assembly and Operating Instructions Any further processing of the products which does not comply with their intended use is not permitted The end product manufacturer and fitter have to ensure that all the current statutory official regulations and in particular EMC regulations are adhered to during utilisation of our products especially with regard to end product assembly installation and customer advice Safety Information The following safety instructions and warnings are intended to avert hazards and to prevent damage to property and personal injuries Please retain for future reference A Caution Denotes a potentially hazardous situation If this is not avoided injuries may result Attention Denotes a potentially hazardous situation If this is not avoided the product or some thing in its vicinity may be damaged IEY Note Denotes user tips and other useful information Important safety instructions fo
9. ion To remove the drive or delete the internal memory the Becker setting control for drives with electronic limit stop is also required This can be used to reset the factory settings of the tubular drive for example in order to re install the equipment remove the drive set a new end limit operate a faulty drive in the emergency programme Deleting the end limits using the setting controls L Note Please note that a protection lock is engaged after setting the positions to avoid unintended erasure of the positions Action Reaction a Erase final positions during installation Press the reset button 1 for one sec This is acknowledged by a double click ond of the tubular drive double click The end limit is deleted b Erase final positions after installation Move the canopy between the end lim its 2 1 Press the reset button 1 for one second 2 Also press the control button 2 down and keep it depressed 3 Now release the reset button 1 and still keep the control button 2 depressed 4 After one second press the reset This is acknowledged by a double click button 1 again as well of the tubular drive 7 Y double click Both end limits are deleted EN iy AWN T AS EIN SY AA J Assembly and Operating Instructions What should you do if Problem Cause Remedy Screen curtain torn off Old curtain Replace with new curt
10. r the user A Caution Failure to observe these instructions can lead to serious injuries e All operational work including maintenance and cleaning on electrical installations as well as other parts of the construction must always be performed by authorised specialists especially by qualified electricians e Do not allow children to play with control units e Systems have to be regularly checked by authorised specialists for wear and damages e Always put damaged systems out of operation immediately until they are repaired by an authorised specialist e Donotoperate equipment if people or objects are within the danger zone e Observe the danger zone of the equipment during operation e Bring the equipment to a stop and disconnect the mains power supply when maintenance and cleaning jobs are performed either on the system itself or in the immediate vicinity of it e Ensure that there is an adequate distance at least 40 cm between moving parts and adjacent objects e Crushing and shearing points must be avoided or protected A Important safety instructions for the installation and commissioning Caution Failure to observe these instructions can lead to serious injuries e Please comply with the safety instructions EN 60 335 2 97 Please note that these safety instructions cannot be assumed as being complete since this standard does not consider all the possible causes of risk For exa mple the construction of the operated product the effectivene
11. ss of the drive in the location of installation or the mounting of the final product in the end user s place of usage cannot be taken into consideration by the drive manufacturer If any questions or concerns regarding the safety instructions contained in the standard arise please contact the manufacturer of the respective part or end product e All operational work including maintenance and cleaning on electrical installations as well as other system parts must always be performed by authorised specialists especially qualified electricians e During operation of electrical or electronic equipment and units certain components are subject to a hazardous electrical voltage Physical injuries or damage to property can result in the event of unqualified interventions or failure to comply with the warning notices e All applicable standards and regulations for the electrical installation must be complied with e Only use spare parts tools and additional devices which are authorised by Becker e Unapproved third party products or modifications to the system and its accessories represent a risk to your safety and the safety of others This means that the utilisation of unapproved third party products or modifica tions which have not been agreed with or approved by us are prohibited We shall not accept liability for damages arising from such actions e Before installation shut down all lines and control devices that are not essential for operation
12. te drives with electronic limit switching only use control elements time controls which do not draw N potential via the drive The outputs of the control element must be potential free in the neutral position Protect the electrical connections from damp RS Note Becker tubular drives bear the CE mark These drives comply with the valid EU guidelines and meet EMC regulations If the drive is to be operated with units which contain sources of interference the electrician must ensure suitable interference suppression for the relevant devices Technical Data Type P5 205E P5 30SE P9 16SE R8 17SE 5 Po 20 30 16 38 revolutions 230V 50Hz Sample connection Controlling one several drive s via a sin gle switch button Electronic control unit Individual switch Subject to technical changes without notice Vy EN 9 AS EIN NY AA eS Assembly and Operating Instructions E ME pues ON CE OA B ECKER 11 Becker Antriebe GmbH 35764 Sinn Germany www becker antriebe com Ie up oe Te ie a 2010 300 2430 05 07 BECKER
13. y 1 If when the screen is being retracted the tubular drive switches itself off be fore the upper end limit has been reached due to an obstacle the screen is to be moved away from the obstacle and the obstacle removed to allow the upper end limit to be set Adjust the screen to the lower locking position and switch off the tubular drive 2 Installation steps 3 3 1 When the screen has reached the locking position a clack sound can be heard coming from both guide rails 3 The screen is to be stopped directly after the clack sound has been heard 3 1 About 1 5 cm of the screen should be in the lock device If the screen has bypassed the locking position adjust the tubular drive slight ly so that the screen is just above the locking device and reposition by moving the screen downwards again Installation steps 4 4 1 Now operate the tubular drive to move the screen upwards 4 until it is blocked by the locking device 4 1 The tubular drive will stop completing the installation process By moving the screen up and down the tubular drive will now automatically lock and unlock in the lower end limit position Becker drives are intended for short time duty S2 KB 4 min The number of extending and retracting cycles possible for the awning depends on the diameter of the roller tube and the awning s extended length The motor s running time is reduced if the drive has not yet fully cooled down from previous operat

Download Pdf Manuals