Home
Operating Instructions Pond- and Fountain Pumps ARTICLE 50312
Contents
1. C 13 Operating Instructions Pond and Fountain Pumps ARTICLE 50312 50313 50314 50315 50316 50317 oo TECHNIK LICHT KRAFT V Vor Inbetriebnahme Bedienungsanleitung und Sicherheitshinweise lesen und beachten Read and follow the operating instructions and safety information before using for the first time Avant la mise en service lisez le mode d emploi et les consignes de s curit et respectez les Subject to technical changes Due to further developments illustrations functioning steps and technical data may slightly differ Documentation Updates In case you have suggestions for the improvement or if you have noticed irregularities please contact us by WilTec Wildanger Technik GmbH Seite 1 http www wiltec info C i The information contained in this document may change without prior notice at any time No part of this document may be copied without the prior written consent of Wiltec GmbH or reproduced in any other form Wiltec Wildanger Technik GmbH assumes no liability for any errors in this manual or in the wiring diagrams Although Wiltec Wiltanger Technik GmbH has made their best efforts to ensure that this manual is complete accurate and up to date errors can not be ruled out As for problems with this manual please fill out this form and send it back to us FAX note 49 2403 55592 15 from Name Company Phone Fax want to report the following error Ku
2. be carried toa collec WilTec Wildanger TechricGmbH tion point for the recycling of electrical and electroni DE 52249 Eschweiler cal devices By taking care for a correct disposal of this product WEEE Reg Nr DE45283704 you contribute to protect your environment and the health of others Environment and human health are affected by inappropriate waste disposal The recycling of material contributes to reduce the consumption of raw materials For more information about the recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product Address WilTec Wildanger Technik GmbH Konigsbenden 12 28 D 52249 Eschweiler Important information The reprinting even excerpts and any commercial use even in parts of the manual without written permission of Wiltec Wildanger Technik GmbH by WilTec Wildanger Technik GmbH Seite 8 http www wiltec info CE Li EG Declaration of Conformity according to the guideline 2006 95 EG und 2006 42 EG Manufacturer responsible person WilTec Wildanger Technik GmbH Koenigsbenden 12 02249 Eschweiler Deutschland declares that the product Pump l CTP 2803 3803 4803 5803 5003 6003 7003 TYPE 8003 Kind of purpose To pump water in open waters and ponds under the condition of the correct use the compliance with the essential requirements or other rele vant provisions in accordance with the guideline
3. their surrounding areas you have to use the device only in connection with a fault current circuit breaker with a triggering nominal current up 30 mA according to VDE 0100 part 702 and 738 The device is not suitable for the use in swimming pools in any kind of paddle pools or any other wa ters during the operation of which there are humans or animals The commissioning of the device dur ing the stay of humans or animals in the danger zone is not allowed Ask your electrician This device must not be used by persons including children with reduced physical sensory or mental capabilities or with a lack of experience and or knowledge unless they are supervised by a person responsible for their safety or have been given instructions concerning the use of the device Children should be supervised to ensure that they do not play with the device A ACHTUNG Perform a visual inspection of the device before each use Do not use the device if the safety equipment is damaged or worn Never put the safety equipment out of force e Use the device only for the purpose as specified in this manual e You are responsible for the safety in the work area e If the power cord or the plug is damaged by external influences the cord must not be repaired Since the cord is molded with the stator a replacement is not possible the pump has to be scrapped e The specified unit voltage of 230 volts AC as indicated on the nameplate has to match the ex istin
4. Ist he water supply sufficient gt Improve water supply Is there dirt in the pump housing gt Clean as below mentioned Tube or hose clogged gt Clean Hose bent too long gt Check replace cut by WilTec Wildanger Technik GmbH Seite 5 http www wiltec info C i Fountain upper part 1 Fountain upper part 2 Connection tube 5 Connection tube large 6 Insertnut O 7 Gasket 8 Outlet AJ 9 Outletnut J 10 T par Regulator 11 Flowrateregulator 12 Filter basket suction strainer 13 Pumphousig Safety pin IN ECS 18 15 Lower rotary unit Oring 0 0 0 16 O ring 5 T 10 11 12 13 17 18 20 20 Rubber stands D NN Mi LLII LELLES X mance Flow rate Delivery head inch kg 3w soom 33m X 3 a TOW ZH0S AO0vC 0cc DV 3 3 3 3 by WilTec Wildanger Technik GmbH Seite 6 http www wiltec info Clean the pump and the filter basket once a week even when the pump s performance re duces oeparate the pump from the power supply Unscrew the attachment picture 1 Rotate the filter basket by 90 picture 2 to remove it Slide the blue lock to Open to unlock the engine housing Rotate the engine housing by 90 picture 4 to remove it Remove the rotary to clean it picture 5 Us
5. The electrical connection is made to a grounded socket 230 volts 50 Hz protection at least 6 Ampere e By a built in therman protection the engine is protected against overloading or blocking In case of overheating the pump is switched off automatically by the protection After cooling down the pump again switches on automatically Mains connection Your pond pump is already equipped with a grounded plug The pump is meant to be for a connection to a grounded socket with 230 volts 50 Hz Make sure that the socket is sufficiently secured at least 6A and in a good condition Run the pump plug into the socket The pump is ready for operation A Information Installation 1 Make sure that the mains voltage corresponds with the specifications as indicated on the name plate 2 Do not install the pump directly into the pond mud but install it on a stone thus ensuring that it does not suck any sludge 3 Check the delivery head maximum depth This information can be found on the nameplate too 4 The pump is to be installed as follows either in a fixed position with a fixed pipeline or in a fixed position with a flexible tubing 5 Route the cable in a protected way in order to exclude the possibility of damage 6 You can vary the shape of the water fountain by changing the position of the screw in the foun tain head The flow rate can be regulated by means of a 3 way valve 7 Connect the pump to the power supply 8 The p
6. e a soft brush or a sponge for cleaning and clean in running water Check whether the O ring is located in the right place before you start reassembling the pump fO Qo OD DI oh Overwintering 1 Remove the pump from the water and separate it from the power supply 2 Clean the pump the way as indicated in the cleaning instructions 3 Check the pump regarding damages for example cracks in the housing 4 Store the pump under frost free conditions if possible in a canister filled with water ATTENTION The power plug must not get into contact with water by WilTec Wildanger Technik GmbH Seite 7 http www wiltec info CE Li Regulations for disposal The EU directive on the disposal of electrical and electronic equipment WEEE 2002 96 EC was transposed with the electrical law All Wiltec electrical devices that are affected by the WEEE are marked with a crossed out waste bin This symbol indicates that this product must not be disposed of with the household waste The company Wiltec Wildanger Technik GmbH has been registered under the WEEE registration number DE45283704 in the German registry EAR Disposal of used electrical amp electronic equipment applicable in the countries of the European Union and other European countries with a separate collection system for this devices The symbol on the product or on its packaging indi cates that this product must not be treated as an ordi nary househould waste but is to
7. g mains voltage e Never lift transport or attach the device by the power cord e Make sure that the electrical connectors are located in a flood safe area and that they are pro tected against moisture e Pull power plug before working on the device e The operator is responsible for the compliance with the local safety and installation regula tions e The user has to exclude by taking the appropriate measures e g installation of an alarm sys tem reserve pump or the like any consequential damage due to flooding of areas and faults in the device e lf there is a failure of the device the repairing is only to be done by a professional electrician or by Wiltec Customer Service e The device must never run dry or be operated with fully closed suction pipe e The device must not be used for the operation in swimming pools e The device must not be installed in the portable water circulation by WilTec Wildanger Technik GmbH Seite 3 http www wiltec info ilf Cc C A WARNING Read all safety instructions Failure concerning the warnings and instructions may result in electric shock fire and or serious injury Keep all warnings and instructions for the future Resistance The maximum temperature of the liquid transported should not exceed 35 C The promotion of aggressive liquids such as acids alkalis silo seepage etc and liquids with abrasive materials for example sand should be avoided Electric connection e
8. ndenbetreuung Wiltec Wildanger Technik GmbH e mail service wiltec info Tel 49 2403 55592 0 Introduction Thanks for purchasing this quality product To minimize the risk of injury we ask you to take some basic safety precautions when using this device Please read this manual carefully and make sure that you have understood them Always use a grounded power supply with the correct voltage The corresponding mains voltage is indicated on the nameplate If you are not sure whether the connection is grounded have it checked by a qualified technician Never use a defective power cord Do not open this device in moist or wet conditions or when you are wet yourself and protect it from direct sunlight Install the device in a safe place so that no one can neither step fall or damage the cable Provide for an adequate cooling by the ambient air and avoid heat accumulation Unplug before cleaning the device and only use a damp cloth Avoid any cleaning agents and make sure that no liquid enters the device The interior of the device does not contain any parts that have to be main tained by users Leave the maintenance adjustment and repair to qualified personnel In case of any external intervention the 2 year warranty period shall expire Keep this manual in a safe place by WilTec Wildanger Technik GmbH Seite 2 http www wiltec info CE Li Sicherheitshinweise A VORSICHT On standing waters garden ponds swimming ponds as well as
9. s 2006 95 EG und 2006 42 EG complies due to its type and construction as well as the way it has been distributed by us to its speci fied performance In the evaluation of the product regarding the requirements of the guidelines the following standards have been applied EN 60335 1 2012 EN 60335 2 41 2003 A1 2004 A2 2010 EN 62233 2008 Any modification of the product causes this declaration to lose its validity Eschweiler 02 Dezember 2013 AL Bernd Wildanger Managing Director by WilTec Wildanger Technik GmbH Seite 9 http www wiltec info
10. ump operates as long as it is disconnected from the power supply Commissioning Once you have read carefully the installation and operating instructions you may take your new pump into operation in consideration of the following items Check that the pressure pipe is attached properly Make sure the electric connection is 230V 50Hz Check that the socket is in an adequate condition Make sure that neither humidity nor water gets into contact with the mains connection Install the pump below the water surface Avoid that the pump runs dry Never operate the pump without any filter basket because a filter basket protects the pump from coarse pollutants that can cause the pump to get clogged by WilTec Wildanger Technik GmbH Seite 4 http www wiltec info C i Warning instructions The pond motor pump is a proven quality product which is submitted to strict final inspection To ensure a proper and continuous operation of the pump we recommend a regular control and care To provide for a proper operation it is necessary to clean the pump regularly We recommend a weekly cleaning Overload protection The pump has a built in overload protection After switching off by overload protection the pump has to cool down for a short period of time before it operates again In case it does not rework automati cally perform the following checks Could the pump after switch off by the overload protection sufficiently cool down
Download Pdf Manuals
Related Search
Related Contents
ホームエレクター スペースラック取扱説明書[691.7 KB] Manuel - AstralPool Quelque chose de pourri dans le post-empire Kopie - copie - Operator's Manual TIS TIS MK1 - E 2014 FUSION HYBRID Suporte de teto motorizado para TV - GSP 252 MULTIPURPOSE LATHE WITH MILLING MACHINE AT320 Whitehall Products 1002BS Instructions / Assembly VERNIS HOLLANDAIS Copyright © All rights reserved.
Failed to retrieve file