Operating Instructions Control Unit SG-RSV 206/X

image

Contents

1. brown SG RSV 206 1 JLIL_ yes Sensor activated no yes Sensor cable break no on Output off yes Sensor activated no yes Sensor cable break no on Output off SG RSV 206 2 JL ee Installation Fix with the aid of the 4 integrated fixing eyelets with screws M4 with cable ties WARNING Always affix rear side with type plate to assembly surface Connection Supply voltage 1 Sensor 1 2 3 Sensor 2 3 4 Output circuit 5 6 WARNING Do not disconnect or connect live lines When using screw terminals end sleeves should be used on non tin plated conductor cores Commissioning After connecting the sensors the output circuit and the supply voltage carry out a function test in the following order SG RSV 206 1 Sensor not activated no output signal connected load is inactive Sensor activated Output signal present connected load is active SG RSV 206 2 Sensor not activated Output signal present connected load is active Sensor activated no output signal connected load is inactive Mayser Polymer Electric Postfach 3048 89020 Ulm Germany Tel 49 731 2061 0 Fax 49 731 2061 222 Page 4 4 Maintenance and troubleshooting Maintenance The Control Unit is maintenance free Check safety installation at least once a month by activating the individual sensors Subject to technical modifications Mayser Polymer Electric Postf
2. ach 3048 89020 Ulm Germany Tel 49 731 2061 0 Fax 49 731 2061 222 Troubleshooting and Remedies Prerequisites SG RSV 206 X with connected sensor and supply voltage SG RSV 206 1 Sensor activated and output does not switch on gt Supply voltage off or incorrect Check polarity and level of supply voltage gt Sensor or supply lines faulty Check sensor with gauge activated Resistor lt 400 Ohm gt Fault still exists Control Unit faulty Replace Control Unit Sensor not activated and output does not switch off gt Sensor or supply lines faulty short circuit or line break Check sensor with gauge not activated set value 1k2 5 gt Actual value set value sensor or supply lines faulty Replace Sensor gt Fault still exists Control Unit faulty Replace Control Unit SG RSV 206 2 Sensor not activated and output does not switch on gt Supply voltage off or incorrect Check polarity and level of supply voltage gt Sensor or supply lines faulty short circuit or line break Check sensor with gauge not activated set value 1k2 5 gt Actual value set value sensor or supply lines faulty Replace Sensor gt Fault still exists Control Unit faulty Replace Control Unit Sensor activated and output does not switch off gt Sensor or supply lines faulty Check sensor with gauge activated Resistor lt 400 Ohm gt Fault still exists Control Unit faulty Replace Control Unit Fault can stil
3. ength L 190 mm Ends tin plated Degree of protection enclosure IP67 Weight with cable approx 15 g Parts supplied Control Unit Potted electronics with firmly installed connection wires Operating Instructions Mayser Polymer Electric Postfach 3048 89020 Ulm Germany Tel 49 731 2061 0 Fax 49 731 2061 222 Page 2 4 Control Unit SG RSV 206 X IMPORTANT NOTES Please read To ensure correct and safe operation of the unit it must be properly trans ported and stored properly installed and commissioned and operated in accordance with the latest technical standards and left our factory in a per fectly safe condition To maintain this condition you must observe the safety European Union you must observe the relevant regulations valid for the country of use accordance with its intended use Only persons familiar with the instal lation commissioning and operation and with the corresponding qualifica regulations marked WARNING in these operating instructions Failure to observe the safety regulations can lead to death injury to personnel or damage tions to prove their skills may work on the units They must observe the con tents of these operating instructions the information stated on the unit and the relevant safety regulations for the installation and operation of electrical systems This unit is designed and tested in to the unit and other systems and equipment Should the information gi
4. l not be detected Mayser Support will help tel 49 731 2061 0 170409 v2 3
5. ven in these operating instructions be inadequate in any way please contact your local technical centre subsidiary or repre sentative When using the device outside the Technical Data Connecting voltage U SG RSV 206 1 SG RSV 206 2 Power consumption Sensor voltage Switching thresholds at 23 C Sensor activated Cable break Output transistor Switching voltage Switching current Response time Output type SG RSV 206 1 Output type SG RSV 206 2 Connecting cable Bend radius Insulation voltage Environmental conditions Permissible ambient temperature Humidity Vibration fatigue limit DC 8 32V DC 8 32V max 1 0 W max U lt 650 Ohm gt 3k2 Ohm max U max 50 mA max 1 ms pnp not inverted pnp inverted min 15 mm 1500 V 50 Hz 30 C to 80 C max 85 rel non condensing 1 g in all 3 levels Mayser Polymer Electric Postfach 3048 89020 UIm Germany Tel 49 731 2061 0 Fax 49 731 2061 222 Important notes Supply voltage must be in accordance with the connecting voltage U indicated on the type plate Permissible temperature range When installing maintain sufficient distance from heat sources min 2 cm if only one sensor When using only one sensor terminate the second input with Resistor 1k2 5 170409 v2 3 030908 v2 3 Page 3 4 Installation and Operation gt green yellow orange red
6. version 2 170409 v2 3 Page 1 4 Control Unit SG RSV 206 X SG RSV 206 X orange Sensor 1 Sensor 2 MAYSER SG RSV 206 X 28 4 14 2 MAYSER Polymer Electric Operating Instructions Control Unit EN 954 Category B for sensors with monitoring resistor 1k2 These operating instructions apply to the following Control Units 1002565 SG RSV 206 112 24V Output pnp not inverted 1003181 SG RSV 206 2 12 24V Output pnp inverted Control This Control Unit contains two moni toring circuits which act on an output transistor The electronics monitor the electrical resistance of the connected sensors which have a specific closed circuit current SG RSV 206 1 When the sensors are not activated normal operating conditions there is no voltage on the output When a sensor is activated or a cable break in the supply lines occurs there is voltage on the output SG RSV 206 2 When the sensors are not activated normal operating conditions there is voltage on the output When a sensor is activated or a cable break in the supply lines occurs there is voltage on the output Enclosure W x H x D mm 38 2 x 28 4 x 7 0 Cable l

Download Pdf Manuals

image

Related Search

Related Contents

Otterbox Defender Case  L`ONP publie le calendrier des paiements 2015  Trimble Juno Series - Farm Works Software  Philips Halogen spot 8711500413222  amalgame - Chaumont  Reason Essentials 8.1 Installationshandbuch  取扱説明書 (6.95 MB/PDF)  乗用田植機 PeS-1A・PeS-1DX・VP1A  Mitsubishi Electric XL6500U LCD  Westin 010601W Use and Care Manual  