Home

Taster-Modul Comfort English operating instructions

image

Contents

1. gt to Vea asd le Retrieve scene press the S1 or S2 key briefly Set the positions completely up down of the blinds that you want to change on the receiving device Set the positions any values of the blinds that you want to change on the receiving device Save scene press the S1 or S2 key for more than 3 seconds The blinds move down a step and then back up to indi cate that the saving procedure has been successful Operating the module basic functions Status LED red of the module In combination with 1 gang insert Operation Status feedback red LED lights up when load is switched on In combination with 2 gang insert Operation Status feedback red LED lights up when load is switched on In combination with central unit insert Operation Status feedback red LED flashes 1x after operation Switching the orientation LED green on off Standard switched off Operation Status feedback LED flashes 4x Switching memory function on off Only in combination with dimmer inserts The device memorises the brightness level that was last set Standard switched off Operation Status feedback LED flashes 4x Switching on memory function Switching off memory function Resetting to default settings Operation Status feedback LEDs flash 8x Technical data Display elements Pu
2. case lighting function Universal dimmer insert 2 gang Push button module 1 gang locally switching and dim ming both channels simul taneously staircase lighting function Push button module 2 gang locally switching and dim ming both channels sepa rately staircase lighting function both channels si multaneously Controlling blinds roller shutter e Blind control insert Push button module 1 gang locally raising lowering sun protection function Push button module 2 gang locally raising lowering re trieving and saving local blind scenes Comfort any position sun protection function Function overview of the modules on sending insert Complete the module with the sending central unit insert in order to carry out global light and blind control viathe PlusLink PL Global light and blind control e Central unit insert Push button module 1 gang globally switching globally dimming globally raising lowering staircase lighting function Push button module 2 gang globally switching globally dimming globally raising lowering staircase lighting function retrieving and saving global light blind scenes Connections displays and operating elements Front LEDs status orientation Push buttons of the push button module 1 gang O Push buttons of the push button module 2 gang o n o Rear
3. Lichtszene Eins tze zum Schalten und Dimmen siehe Funktions bersicht e Pr senzmelder in den PL Linien rufen keine Sze 1 nen auf sondern schalten Verbraucher f r 24 Stunden ein oder aus S1 S2 Lichtszenen ndern und speichern Am Beispiel eines Dimmers Wy AN Szene aufrufen Taste S1 oder S2 kurz dr cken Helligkeitswerte der Lampen die Sie ver ndern m chten am empfangenden Ger t einstellen Szene speichern Taste S1 oder S2 lang dr cken Bei erfolgreicher Speicherung schalten sich alle Lampen kurz aus und wieder ein Danach nehmen die Lampen den gespeicherten Helligkeitswert an Jalousieszenen ndern und speichern Bei Jalousieszenen k nnen Sie in Kombination mit dem Taster Modul Basic auf dem empfangenden Einsatz nur die festen Positionswerte vollst ndig hoch runter speichern In Kombination mit den Taster Modulen Comfort und Comfort Plus auf dem empfangenden Einsatz k nnen Sie beliebige Positionswerte 2 speichern gt to Yop aed Elo Szene aufrufen Taste S1 oder S2 kurz dr cken Positionen vollst ndig hoch runter der Jalousi en die Sie ver ndern m chten am empfangen den Ger t einstellen Positionen beliebige Werte der Jalousien die Sie ver ndern m chten am empfangenden Ge r t einstellen Szene speichern Taste S1 oder S2 lang dr cken Bei erfolgreicher Speicherung fahre
4. Modul 2fach Szene aufrufen Taste S1 oder S2 kurz dr cken Helligkeitswert einstellen Szene speichern Taste S1 oder S2 lang dr cken Bei erfolgreicher Speicherung schalten sich alle Lampen kurz aus und wieder ein Danach nehmen die Lampen den gespeicherten Helligkeitswert an Lokale Jalousieszenen Comfort ndern und speichern Nur f r Taster Modul 2fach Bei Jalousieszenen Comfort k nnen Sie beliebige Posi tionswerte speichern Jalousie in die obere Position fahren und 2 Minuten Laufzeit abwarten bis die Status LED erlischt Gew nschte Position der Jalousie einstellen Szene speichern Taste S1 oder S2 lang dr cken Bei erfolgreicher Speicherung fahren die Jalousien ei nen Schritt ab und wieder auf Treppenlichtfunktion einstellen Auf der R ckseite des Moduls k nnen Sie die Art der Treppenlichtfunktion ohne mit Vorwarnung und die Nachlaufzeit einstellen Mit der Nachlaufzeit stellen Sie ein wie lange der ange schlossene Verbraucher eingeschaltet bleibt stufenlos von 10 s bis 30 min Die Vorwarnung zeigt das Ende der Nachlaufzeit an Die Verbraucher werden kurz aus und wieder eingeschaltet in Kombination mit Schalt Eins tzen bzw werden langsam heruntergedimmt in Kombination mit dimmba ren Eins tzen Nach Ablauf der Vorwarnzeit 30 s nicht einstellbar werden die Verbraucher ausgeschaltet Art der Treppenlichtfunktion w hlen und Nachlauf zeit einstellen Treppenlic
5. load remains switched on continuously from 10 s to 30 min The prewarning indicates the end of the overshoot time The loads are switched off briefly and then back on again in combination with switch inserts or are dimmed down slowly in combination with dimmable inserts The loads are switched off after the prewarning time has elapsed 30 s not adjustable Select the type of staircase lighting function and set the overshoot time Staircase lighting function without prewarning 200 ms 10s lt e n x 2min 30min Switching without prewarning Dimming without prewarning Overshoot time Staircase lighting function with prewarning 200 ms yo An 10s e 2min 30min Switching with prewarning Dimming with prewarning Overshoot time Prewarning time 30 s not adjustable Starting the staircase lighting function MSY a gt Yo a l AN a Upper right push button starting the staircase lighting function If actuated repeatedly during the overshoot time pre warning time the latter restarts In combination with a 2 gang insert both channels are switched simultaneously V5111 581 02 08 13 Switching on staircase lighting for 24 h Only for push button module 2 gang e Upper left push button switch on staircase lighting for 24h e Lower left push button switch off staircase lighting In order to end the function press the lower l
6. Module interface Potentiometer for overshoot time Potentiometer for type of staircase lighting function off without with prewarning Mounting the module Insert see function overview Frame Push button module 1 gang 2 gang Rockers 1 gang 2 gang Operating the module local light and blind control The operation of the module is illustrated below using the 2 gang push button module as an example The Blind roller shutter will be referred to below as blind Switching loads on off In combination with 1 gang insert In combination with 2 gang insert e right push button channel 1 e left push button channel 2 vl hr 122058 2 2 lt 0 5s za I x 1 as 3 w Q X 4 SWS a WS DA Q SY y gt 530S W ANY S u When using the 1 gang push button module both chan nels are switched simultaneously Dimming loads In combination with 1 gang insert N yy In combination with 2 gang insert e right push button channel 1 e left push button channel 2 Retrieving local light or blind scenes Only for push button module 2 gang Standard scenes All devices are delivered from the factory with preset tings for a light or blind scene S1 light on 100 blind up 2 light off blind down ra S lt 0 58 lt rj gt Retrieve scene press the S1 or S2 push button briefly e The devices of the light scene adopt the saved bright ness value e
7. The devices of the blind scene initially move to upper position After a runtime of 2 minutes they move to the saved position Changing and saving local light scenes Only for push button module 2 gang Retrieve scene press the S1 or S2 key briefly Set the brightness value Save scene press the S1 or S2 push button for more than 3 seconds All lights are switched off briefly and then back on again to indicate that the saving procedure has been success ful Then the lights adopt the saved brightness value Changing and saving local blind scenes Comfort Only for push button module 2 gang For blind scenes Comfort you can save any position val ues Move the blind to the upper position and wait for the running time of 2 minutes until the status LED goes When using the 1 gang push button module both chan nels are dimmed simultaneously Controlling blinds e raising lowering gt 0 5 s e up down in steps lt 0 5 s 1 aa G Setthe desired position of the blind Save scene press the S1 or S2 push button for a long time The blinds move down a step and then back up to indi cate that the saving procedure has been successful Setting the staircase lighting function On the rear of the module you can set the type of stair case lighting function without with prewarning and the overshoot time When setting the overshoot time you specify how long the connected
8. able for any damage to property or personal inju ry Getting to know the push button module With the push button module Comfort referred to below as module you can carry out various functions such as e switching dimming and controlling blinds e retrieving changing and saving light scenes and blind scenes Comfort e staircase lighting function Function overview of the modules on re ceiving inserts Complete the module with the receiving inserts for switching dimming or controlling blind roller shutter in order to carry out local light and blind control Switching Electronic switch insert e Relay switch insert Push button module 1 gang locally switching staircase lighting function Push button module 2 gang locally switching retrieving and saving local light scenes staircase lighting function Electronic switch insert 2 gang e Relay switch insert 2 gang Dimming Push button module 1 gang locally switching both channels simultaneously staircase lighting function Push button module 2 gang locally switching both channels separately stair case lighting function both channels simultaneously e Universal dimmer insert e 1 10 V insert e DALI insert Push button module 1 gang locally switching and dim ming staircase lighting function Push button module 2 gang locally switching and dim ming retrieving and saving local light scenes stair
9. dimming see function overview OO Global blind control Example of global raising lowering and up down in steps of the 1 4 PL lines On operation of the push button module on the central unit insert all loads in the PL lines are controlled togeth er e long press on the push button gt 0 5 s raising lower ing e short press on the push button lt 0 5 s up down in steps Module on central unit insert Blind control insert Operating the module retrieving changing and saving global scenes via PlusLink e Global scenes via PlusLink are possible with the 1 combination of a central unit insert and a push button module 2 gang e When you save a scene this affects all connect 1 ed devices of the PL lines Proceed as follows to change and save a scene accord ing to your requirements Retrieve scene standard scenes are set at the fac tory Change the states of individual devices in the light and or blind scene Check that all devices have the state you require Save scene Retrieving global light or blind scenes Standard scenes All devices are delivered from the factory with preset tings for a light or blind scene S1 light on 100 blind up S2 light off blind down Panic button light on 100 blind down Retrieve scene press the S1 or S2 key briefly e The devices of the light scene adopt the saved br
10. eft push but ton or restart the overshoot time Setting the pulse generator Only in combination with relay switch insert 200 ms 10s ei fl e 200 ms 2min 30min Starting the pulse generator When actuated the connected staircase lighting timer e g Eltako is activated by a pulse 200 ms and the set overshoot time of the staircase lighting timer begins If actuated repeatedly during the overshoot time the latter restarts Controlling the module from another location Controlling loads from another location via PlusLink with Central unit insert or side controller Plus 1 gang 2 gang switching dimming controlling blind retrieving scenes controlling staircase lighting Mechanical push button double push button Sensors Operating the module global light and blind control via PlusLink e The global control via PlusLink is possible with 1 the combination of a central unit insert and a push button module Global light control Example of globally switching on off and dimming the 1 4 PL lines On operation of the push button module on the central unit insert all loads in the PL lines are controlled togeth er e short press on the push button lt 0 5 s switching on off e long press on the push button gt 0 5 s dimming AN Sa Wy Wig AS gt lt w wg A Module on central unit insert Inserts for switching and
11. elle mit 8 Kontaktstiften Schneider Electric GmbH c o Merten Gothaer StraBe 29 40880 Ratingen www merten de www merten austria at Kundenbetreuung Telefon 49 2102 404 6000 V5111 581 02 08 13 merten by Schneider Electric Push button module Comfort Operating instructions System M Push button module Comfort 1 gang Art no MEG51 11 0300 Push button module Comfort 2 gang Art no MEG5121 0300 English operating instructions e You will find the English version of these operat 1 ing instructions at www merten com Necessary accessories Complete the push button module Comfort 1 gang and 2 gang with corresponding inserts see function overview corresponding 1 gang or 2 gang rockers in the design System M frames in the design System M For your safety A DANGER Risk of serious damage to property and per sonal injury e g from fire or electric shock due to incorrect electrical installation Safe electrical installation can only be ensured if the person in question can prove basic knowl edge in the following areas e Connecting to installation networks e Connecting several electrical devices e Laying electric cables These skills and experience are normally only possessed by skilled professionals who are trained in the field of electrical installation technol ogy If these minimum requirements are not met or are disregarded in any way you will be solely li
12. htfunktion ohne Vorwarnung 200 ms 10s lt e n x 2min 30min Schalten ohne Vorwarnung Dimmen ohne Vorwarnung Nachlaufzeit Treppenlichtfunktion mit Vorwarnung 200 ms yr An 10s e 2min 30min Schalten mit Vorwarnung Dimmen mit Vorwarnung Nachlaufzeit Vorwarnzeit 30 s nicht einstellbar Treppenlichtfunktion starten a 4 Wy MN 4 4 eq Taste oben rechts Treppenlichtfunktion starten Bei wiederholter Bet tigung w hrend der Nachlaufzeit Vorwarnzeit startet diese erneut In Kombination mit einem 2fach Einsatz werden beide Kan le gleichzeitig geschaltet V5111 581 02 08 13 Treppenlicht f r 24 h einschalten Nur f r Taster Modul 2fach bei eingeschalteter Trep penlichtfunktion un e Taste oben links Treppenlicht f r 24 h einschalten e Taste unten links Treppenlicht ausschalten Zum Beenden der Funktion dr cken Sie die Taste unten links oder starten Sie die Nachlaufzeit erneut Impulsgeber einstellen Nur in Kombination mit Relais Schalt Einsatz 200 ms ic 2min 30 min fl 200 ms Impulsgeber starten Bei Bet tigung wird der angeschlossene Treppenlicht automat z B Eltako durch einen Impuls 200 ms akti viert und die eingestellte Nachlaufzeit des Treppenlichtautomaten beginnt Bei wiederholter Betati gung w hrend der Nachlaufzeit startet diese erneut Modul von anderer Stelle steuern Verbraucher v
13. ight ness value e The devices of the blind scene initially move to the up permost position After a running time of maximum 2 minutes has elapsed the blinds move to the saved po sition Alle max 10 Module on central unit insert Panic button mechanical push button PLline 4 with blind scene Blind control insert PL line 2 and 3 with light scene Inserts for switching and dimming see function overview e Presence detectors in the PL lines do not retrieve 1 scenes but switch loads on or off S1 S2 for 24 hours Changing and saving light scenes Using a dimmer as an example Wy AN Retrieve scene press the S1 or S2 key briefly Setthe brightness values of the lights that you want to change on the receiving device Save scene press the S1 or S2 key for more than 3 seconds All lights are switched off briefly and then back on again to indicate that the saving procedure has been success ful Then the lights adopt the saved brightness value Changing and saving blind scenes In combination with the push button module Basic on the receiving insert you can only save the fixed position val ues of completely up down 2 for blind scenes In combination with the push button modules Comfort or Comfort Plus on the receiving insert you can save any position values DV
14. merten by Schneider Electric Taster Modul Comfort Gebrauchsanleitung System M Taster Modul Comfort 1fach Art Nr MEG51 11 0300 Taster Modul Comfort 2fach Art Nr MEG5121 0300 English operating instructions e You will find the English version of these opera 1 ting instructions at www merten com Notwendiges Zubehor Komplettieren Sie das Taster Modul Comfort 1fach und 2fach mit entsprechenden Eins tzen siehe Funktions ber sicht entsprechenden 1fach bzw 2fach Wippen im De sign System M Rahmen im Design System M F r Ihre Sicherheit A GEFAHR Gefahr von schweren Sach und Personen sch den z B durch Brand oder elektrischen Schlag aufgrund einer unsachgem en Elektroinstallation Eine sichere Elektroinstallation kann nur gew hr leistet werden wenn die handelnde Person nach weislich ber Grundkenntnisse auf folgenden Gebieten verf gt e Anschluss an Installationsnetze e Verbindung mehrerer elektrischer Ger te e Verlegung von Elektroleitungen ber diese Kenntnisse und Erfahrungen verf gen in der Regel nur ausgebildete Fachkr fte im Bereich der Elektro Installationstechnik Bei Nichterf llung dieser Mindestanforderungen oder Missachtung droht f r Sie die pers nliche Haftung bei Sach und Personensch den Taster Modul kennenlernen Mit dem Taster Modul Comfort im Folgenden Modul genannt k nnen Sie verschiedene Funktionen ausf h ren
15. n le gleichzeitig Jalousien Rollladen steuern Jalousiesteuerungs Ein satz Taster Modul 1fach lokal hoch runterfahren Sonnenschutzfunktion Taster Modul 2fach lokal hoch runterfahren lokale Jalousieszenen Comfort aufrufen und spei chern beliebige Positio nen Sonnenschutzfunktion Funktions bersicht der Module auf sendendem Einsatz Komplettieren Sie das Modul mit dem sendenden Zent ralstellen Einsatz um globale Licht und Jalousiesteue rung ber den PlusLink PL auszuf hren Globale Licht und Jalousiesteuerung e Zentralstellen Einsatz Taster Modul 1fach global schalten global dimmen global hoch run terfahren Treppenlicht funktion Taster Modul 2fach global schalten global dimmen global hoch run terfahren Treppenlicht funktion globale Licht Jalousieszenen aufrufen und speichern Anschl sse Anzeigen und Bedienelemente Vorderseite LEDs Status Orientierung Tasten des Taster Moduls 1fach Tasten des Taster Moduls 2fach R ckseite Modul Schnittstelle Potentiometer f r Nachlaufzeit Potentiometer f r Art der Treppenlichtfunktion aus ohne mit Vorwarnung 000 Modul montieren Einsatz siehe Funktions bersicht Rahmen Taster Modul 1fach 2fach Wippen 1fach 2fach Modul bedienen Lokale Licht und Jalousiesteuerung Die Bedienung des Moduls wird stellvertretend am Bei spiel de
16. n die Jalousien ei nen Schritt ab und wieder auf Modul bedienen Basisfunktionen Status LED rot des Moduls In Kombination mit 1fach Einsatz Bedienung R ckmeldung rote LED leuchtet bei geschalteter Last In Kombination mit 2fach Einsatz Bedienung R ckmeldung rote LED leuchtet lt bei geschalteter S Last In Kombination mit Zentralstellen Einsatz Bedienung R ckmeldung rote LED blinkt 1x bei Bet tigung Orientierungs LED gr n ein aus schalten Standard ausgeschaltet Bedienung R ckmeldung LED blinkt 4x Memory Funktion ein ausschalten Nur in Kombination mit Dimmer Einsatzen Das Gerat merkt sich die zuletzt eingestellte Helligkeit Standard ausgeschaltet Bedienung R ckmeldung LED blinkt 4x Memory Funktion einschalten Memory Funktion ausschalten Auf Werkseinstellung zur cksetzen Bedienung R ckmeldung LEDs blinken 8x Technische Daten Anzeigeelemente Taster Modul 1fach 1 Status LED 1 Orientierungs LED Taster Modul 2fach in Kombination mit 1fach Einsatz 1 Status LED 1 Orientierungs LED Taster Modul 2fach in Kombination mit 2fach Einsatz 2 Status LEDs 2 Orientierungs LEDs Bedienelemente Taster Modul 1fach 2 Tasten Taster Modul 2fach 4 Tasten Potentiometer Nachlaufzeit 200 ms 10s 30 min Art der Treppenlicht funktion ohne mit Vorwarnung Anschluss Modul Schnittst
17. on anderer Stelle ber PlusLink steuern mit Zentralstellen Einsatz oder Nebenstelle Plus 1fach 2fach Schalten Dimmen Jalousie steuern Szenen aufru fen Treppenlicht steuern e mechanischem Taster Doppeltaster e Sensoren Modul bedienen Globale Licht und Jalousiesteuerung ber PlusLink Die globale Steuerung ber PlusLink ist m glich in Kombination von Zentralstellen Einsatz und Taster Modul pie Globale Lichtsteuerung Beispiel f r globales Ein Ausschalten und Dimmen von 1 4 PL Linien Bei Bet tigung des Taster Moduls auf dem Zentralstel len Einsatz werden alle Verbraucher in den PL Linien gemeinsam gesteuert e kurzer Tastendruck lt 0 5 s ein ausschalten e langer Tastendruck gt 0 5 s dimmen Modul auf Zentralstellen Einsatz Eins tze zum Schalten und Dimmen siehe Funktions bersicht Globale Jalousiesteuerung Beispiel f r globales Hoch Runterfahren und schrittweises Auf Ab von 1 4 PL Linien Bei Bet tigung des Taster Moduls auf dem Zentralstel len Einsatz werden alle Verbraucher in den PL Linien gemeinsam gesteuert e langer Tastendruck gt 0 5 s hoch runterfahren e kurzer Tastendruck lt 0 5 s schrittweise auf ab Modul auf Zentralstellen Einsatz Jalousiesteuerungs Einsatz Modul bedienen Globale Szenen ber PlusLink aufrufen ndern und speichern e Globale Szenen be
18. r PlusLink sind m glich in 1 Kombination von Zentralstellen Einsatz und Taster Modul 2fach e Wenn Sie eine Szene speichern dann betrifft das 1 alle angeschlossenen Ger te der PL Linien Um eine Szene nach Ihren W nschen zu ndern und zu speichern gehen Sie folgenderma en vor Szene aufrufen schon ab Werk sind Standard Sze nen eingestellt Zustande einzelner Gerate in der Licht bzw Jalou sieszene verandern Pr fen ob sich alle Ger te im gew nschten Zustand befinden Szene speichern Globale Licht oder Jalousieszenen aufrufen Standard Szenen Ab Werk verf gen alle Ger te ber Voreinstellungen f r eine Licht bzw Jalousieszene S1 Licht an 100 Jalousie hoch S2 Licht aus Jalousie runter Paniktaster Licht an 100 Jalousie runter Szene aufrufen Taste S1 oder S2 kurz dr cken Die Ger te der Lichtszene nehmen den gespeicherten Helligkeitswert an Die Ger te der Jalousieszene fahren zuerst in die oberste Position Nach Ablauf einer Laufzeit von maxi mal 2 Minuten fahren die Jalousien in die gespeicher te Position lt lt PL3 Be A ser N A B Se Kr imax 10 imax 10 imax 10 Modul auf Zentralstellen Einsatz Paniktaster mechanischer Taster PL Linie 4 mit Jalousieszene Jalousiesteuerungs Einsatz PL Linie 2 und 3 mit
19. s 2fach Taster Moduls gezeigt Im Folgenden wird Jalousie Rollladen nur mit Jalou sie bezeichnet Verbraucher ein ausschalten In Kombination mit 1fach Einsatz In Kombination mit 2fach Einsatz e rechte Taste Kanal 1 e linke Taste Kanal 2 aty ka 122058 2 2 lt 0 5s Sa I x 1 as 3 w Q X 4 SWS a WS MY SY VY Zs W SYS Y Bei Verwendung des 1fach Taster Moduls werden beide Kan le gleichzeitig geschaltet Verbraucher dimmen In Kombination mit 1fach Einsatz N yy FWS WY Nant In Kombination mit 2fach Einsatz e rechte Taste Kanal 1 e linke Taste Kanal 2 2 4 gt 05s WY 7 WS Bei Verwendung des 1fach Taster Moduls werden beide Kan le gleichzeitig gedimmt Jalousien steuern e hoch runterfahren gt 0 5 s e schrittweise auf ab lt 0 5 s ope Lokale Licht oder Jalousieszene aufrufen Nur f r Taster Modul 2fach Standard Szenen Ab Werk verf gen alle Ger te ber Voreinstellungen f r eine Licht bzw Jalousieszene S1 Licht an 100 Jalousie hoch 2 Licht aus Jalousie runter Szene aufrufen Taste S1 oder S2 kurz dr cken Die Ger te der Lichtszene nehmen den gespeicherten Helligkeitswert an Die Ger te der Jalousieszene fahren zun chst in die obere Position Nach einer Laufzeit von 2 Minuten fah ren sie in die gespeicherte Position Lokale Lichtszenen ndern und speichern Nur f r Taster
20. sh button module 1 gang Push button module 2 gang in combination with 1 gang insert Push button module 2 gang in combination with 2 gang insert Operating elements Push button module 1 gang Push button module 2 gang Potentiometer Overshoot time Type of staircase lighting function Connection www merten austria at Customer care centre Phone 49 2102 404 6000 1 status LED 1 orientation LED 1 status LED 1 orientation LED 2 status LEDs 2 orientation LEDs 2 push buttons 4 push buttons 200 ms 10s 30 min without with prewarning module interface with 8 contact pins Schneider Electric GmbH c o Merten Gothaer Stra e 29 40880 Ratingen www merten com V5111 581 02 08 13
21. wie z B e Schalten Dimmen Jalousie steuern e Lichtszenen und Jalousieszenen Comfort aufrufen ndern und speichern e Treppenlichtfunktion Funktions bersicht der Module auf empfangenden Eins tzen Komplettieren Sie das Modul mit den empfangenden Eins tzen zum Schalten Dimmen oder Jalousie Rollla den steuern um lokale Licht und Jalousiesteuerung auszuf hren Schalten Elektronik Schalt Ein satz Relais Schalt Einsatz Taster Modul 1fach lokal schalten Treppen lichtfunktion Taster Modul 2fach lokal schalten lokale Licht szenen aufrufen und spei chern Treppenlichtfunktion Elektronik Schalt Ein satz 2fach Relais Schalt Einsatz 2fach Dimmen Taster Modul 1fach lokal beide Kan le gleich zeitig schalten Treppen lichtfunktion Taster Modul 2fach lokal beide Kan le separat schalten Treppenlichtfunk tion beide Kan le gleich zeitig e Universal Dimmer Ein satz e Steuerungs Einsatz 1 10 V DALI Steuerungs Ein satz Taster Modul 1fach lokal schalten und dim men Treppenlichtfunktion Taster Modul 2fach lokal schalten und dim men lokale Lichtszenen aufrufen und speichern Treppenlichtfunktion Universal Dimmer Ein satz 2fach Taster Modul 1fach lokal beide Kan le gleich zeitig schalten und dim men Treppenlichtfunktion Taster Modul 2fach lokal beide Kan le separat schalten und dimmen Treppenlichtfunktion bei de Ka