Home
Operating Instructions for Reka Hot
Contents
1. Safety Instructions for the Operation of the MS 80 and MS 150 Hot Melt Glue Applicators 00 Wear protective gloves and safety goggles when ever you work with the applicator G N A Avoid accidents by stumbling Lay all cables hoses and conducts so that they will not cause any risk of stumbling For this install cable ducts and bridges y Ne J e Only fill the tank up to just under the upper rim e Never exceed the operating temperature of the hot melt This temperature is indicated in the techni cal datasheet of the hot melt Overheating may lead to decomposition which may affect the health of the user as well as the operability of the applicator e Once the applicator has warmed up nozzle and lid are very hot e Never start working before fitting a nozzle first e Unplug the connecting cable before replacing a nozzle Warning risk of burns When a nozzle is re placed liquid glue might leak out e Never bring the hot nozzle into contact with the cable Never direct the glue jet towards people When your skin got into contact with hot glue cool it with cold water immediately Do not try to remove the hot melt from the skin first If necessary consult a doctor When hot adhesive got into your eyes im mediately cool them under running water for about 15 minutes and consult your doctor at once Always deposit the glue applicator on the stand pro vided for this purpose Do not lay t
2. instrument temperature 60 80 C and empty Replacing a nozzle when the applicator is cold may damage the equipment Replacing the nozzle when the applicator is too hot causes liquid glue to flow out The melting range as well as the melting point of the used glue may be taken from the technical datasheet of the respective glue Cleaning and Maintenance Never fill soiled glue into the melting tank If you observe all advices given in the operating manual the glue applicator does normally not need cleaning The non reactive glue contained in the applicator will remelt and can be used for gluing again The working temperature of the respective glue may be taken from the technical datasheet which can be procured from the producer of the glue This temperature must not be exceeded otherwise the glue may coke in the glue applicator Hot melts on a polyamide basis are particularly sensitive If the glue has coked the applicator with should be cleaned with REKA cleaning liquid article 3519 Never clean the applicator with solvent benzine benze ne toluene acetone turpentine etc risk of explosion If the applicator is used very often we recommend to have it maintained regularly For this fix a date with our service department Trouble Shooting rekam List of possible fault indications and assistance in trouble shooting In case of damage send the glue applicator to Reka indicating type and serial no of your applicator W
3. screw driver The right end stop is the maximum temperature of 200 C Glue Applicator MS 150 The temperature of the MS 150 glue applicator may be infinitely set up to 200 C For this set the rotary button to the requested position 4 6 approx 70 C 10 approx 100 C 12 approx 160 C approx 190 C Minor leaking out of the nozzle during the heat up period is caused by the hot melt expanding in the nozzle heating chamber Loading Hot Melt The MS 80 150 glue applicators must only be used to dispense non reactive hot melts Never feed other materials The hot melt glue applicator is capable of working with all non reactive hot melt types which are designed for working temperatures of up to max 200 C After the end of the heat up period approx 10 min open the lid and load granulate up to just under the lower rim of the feeding opening Shut the lid and allow the applicator to melt the glue Applying Hot Melt e gt Wear protective gloves and safety goggles when ever you work with the applicator G N A Never start working before fitting a nozzle first Never direct the glue jet towards people Do not start working before the glue has molten Badly molten glue is thick and it needs a lot of force to press it off the applicator Doing so would damage the applicator Always deposit the glue applicator on the wire stand provided for this purpose The glue applicator mu
4. Siemensstr 6 D 76344 Eggenstein Internet http www reka klebetechnik de CE Declaration of Confirmity rekam Product Hot Melt Glue Applicators Types MS 80 MS 150 This is to certify that the above applicators in the design marketed by us are in conformity with the following EC directives until 15 01 2007 73 23 EEC from 16 01 2007 2006 95 EC until 19 07 2009 91 368 EEC from 20 09 2009 2004 108 EC until 28 12 2009 89 336 EEC from 29 12 2009 2006 42 EC 2002 95 EC The following standards have been applied IEC CISPR14 IEC 60335 IEC 60204 IEC 61000 This declaration of conformity shall get invalid if the product is e modified extended or otherwise changed without express approval of Reka Klebetechnik e and or other components than accessories of Reka Klebetechnik are fitted e and if the product is not connected or used as intended Eggenstein September 1 2009 Sy Clavia ota irrt Christa Armbruster Management Purchasing and Production 11 Reka Hot Melt Glue Applicators Spare Parts Technical Specifications Accessories MS 80 rekam MS 80 Legend for Glue Applicator MS 80 Art 5551 230 V 5560 120 V Item Article 1 3859 Casing cpl 2 3861 Cap 3 3911 Nozzle No 2 4 3759 Exit piece 5 3762 Piston cpl 6 3939 Trigger cpl 1 3885 Lid cpl 8 3882 Stand 9 3783 Cord for 230 V 3886 Cord with UL Plug for 120 V Technical Specifications Denomination Articl
5. e number Weight Power supply Power consumption Current consumption Degree of protection Class of protection Temperature control Temperature limitation Temperature constancy Operating temperature Tank capacity Conveying system Length of electric cable Recommended melts Accessories optional Item Article 10 3858 Bend protection 11 3791 O ring 20x2 5 12 3827 O ring 28x3 5 MS 80 MS 80 5551 230 V 5560 120 V 750g 230 V 50 Hz 120 V 60 Hz 200 Watt 0 9A IP 30 Thermostat 20 200 C 5 C 10 min 150 ml Mechanics 1 8 m Hot melt granulate and pillows Balancer art 3544 Download our full nozzle range at www nozzles reka klebetechnik de a A AAdooldd More accessoiries like cleaning liquid or a funnel can be found at www reka klebtechnik de 15 rekam MS 150 Item Article 1 3751 Casing left 2 3752 Casing right 3 3911 Nozzle No 2 4 3759 Exit piece 5 3762 Piston cpl 6 3764 Trigger cpl 7 37166 Lid kpl 8 31M Connector plate cpl 9 3776 Washer 10 3889 Thermostat 11 3781 Indicator lamp for 230 V 3782 Indicator lamp for 120 V Technical Specifications Denomination Article number Weight Power supply Power consumption Current consumption Degree of protection Class of protection Temperature control Temperature limitation Temperature constancy Operating temperature Tank capacity Conveying system Length of electric cable Recom
6. e shall not be responsible for any repair made by yourselves Fault Possible cause operating error Measures to be taken No or too little glue comes off though e Clogged nozzle e Unscrew the nozzle clean the heat up time has been kept exactly or replace it e Temperature too low e Check the temperature The glue is too fluid or too thick e Applicator temperature too high e Check the temperature or too low Glue leaks out of nozzle e Clogged nozzle e Unscrew the nozzle clean it carefully or replace it Unscrew the nozzle at operating temperature wear gloves risk of burns The applicator does not heat up e The applicator is switched off e Is the applicator properly connected to power 10 Environmental Protection K Never throw electric tools in the domestic waste According to the European directive 2002 96 EC for used electric and electronic devices and according to national regulations used electric tools must be collected separately and treated in an environmentally compatible way for re use Reka packing material can be recycled completely Please take instructions for the disposal of hot melt glues and hot melt cartridges from the respective safety datasheet Additional Information Do you have any more questions or requests We should be glad to help you Please contact us by Phone 49 0 721 970780 Telefax 49 0 721 705069 E mail sale reka klebetechnik de Our mailing address is Reka Klebetechnik GmbH amp Co KG
7. e the manufacturer s but the user s responsibility General Safety Instructions Care and Diligence of the User The glue applicator has been designed and fabricated in conformity with the applicable harmonized standards and additional technical specifications So it is state of the art and ensures maximum safety This safety however can only be achieved in the operational practice if all the necessary measures are taken The user of the equipment shall be obliged to plan these measures and to make sure that they are taken In particular the user shall ensure that the applicator to be used is in good working order the personal protective equipment protective gloves safety goggles required for the operating personnel is available and used the operating instructions are in legible condition and available to the operator only sufficiently qualified and authorized personnel operates and maintains the applicator this personnel is regularly instructed in the applicable regulations of operational safety and environmental protection and knows the operating instructions and in particular the included safety instructions Making the Information Available This operating manual shall always be kept at the place of operation of the applicator Be sure that all persons handling the applicator can consult the instructions at any time In addition to this operating manual there must be available instructions regarding legal and ot
8. he applicator on its side Never hold nozzle top upward Do not carry out overhead work Stop using the equipment if the casing is damaged due to shock breakage or heavy wear Do not feed solvents or paraffin Risk of explosion Start up and Control A Avoid accidents by stumbling Lay all cables hoses and conducts so that they will not cause any risk of stumbling For this install cable ducts and bridges y A N 00 Wear protective gloves and safety goggles when ever you work with the applicator A Never direct the glue jet towards people Never lay the hot melt applicator on its side Do not hold the nozzle top upward Do not carry out overhead work Do not start working before fitting a nozzle first Only open the lid when the applicator has warmed up Do not overcharge the applicator only fill it just under the rim Stop using the equipment if the casing is damaged due to shock breakage or heavy wear y The glue applicator must only be used applied for its intended purpose Please read the chapter General Safety Instructions If itis not used as intended this may cause bodily injuries or equipment damages Disregard of the safety instructions for the use of the applicator may lead to serious burns Glue Applicator MS 80 The MS 80 glue applicator is factory set to 190 C The temperature is infinitely adjustable at the rear side of the instrument using a
9. her mandatory regulations relating to accident prevention and to relevant requirements of the employers liability insurance association Safety Symbols This operating manual gives concrete safety instructions to alert the user to remaining unavoidable hazards These hazards imply dangers to e persons e product and equipment Meaning of the Symbols used in the Manual pe N A This symbol indicates that there is above all danger to persons but also to equipment and material Ns y G N A Caution hot surface Accident Prevention Regulation VBG 125 W26 Hot surfaces such as machine parts tanks or materials but also hot liquids cannot always be perceived The utmost caution is advised when this symbol is attached to a component Wear protective gloves whenever you have to touch hot surfaces E G N 00 Wear protective gloves and safety goggles when ever you work with the applicator G N To avoid accidents lay the cables so that they will not cause any risk of stumbling J Safety Measures to be taken during Operation rekam The equipment must only be used by trained instructed and authorized persons These persons must have read the operating instructions and be able to work accordingly Before using the applicator check it for visible damage and make sure that it is only used when in proper and safe condition Notify detected defects to your superior immediately
10. mended melts Accessories optional Legend for Glue Applicator MS 150 Art 5552 230 V 5557 120 V Item Article 12 3783 Cord for 230 V 3886 Cord with UL Plug for 120 V 13 3185 Bend protection 14 3959 Adjusting knob 15 3191 O ring 20x2 5 16 3805 O ring 32x3 5 MS 150 5552 230 V 5557 120 V 1200g 230 V 50 Hz 120 V 60 Hz 200 Watt 0 9A IP 30 Thermostat 20 200 C 5 C 10 min 220 ml Mechanics 1 8 m Hot melt granulate and pillows Balancer art 3544 Download our full nozzle range at www nozzles reka klebetechnik de a A hal More accessoiries like cleaning liquid or a funnel can be found at www reka klebtechnik de MS 150 17 03_2010 Reka Klebetechnik GmbH amp Co KG Siemensstra e 6 D 76344 Eggenstein Telefon 49 0 721 970780 Telefax 49 0 721 705069 E Mail sale reka klebetechnik de Internet http www reka klebetechnik de
11. rekam Operating Instructions for Reka Hot Melt Glue Applicators MS 80 onan F WN Table of Contents Product Description General Safety Instructions Safety Measures to be taken during Operation Start up and Control Cleaning and Maintenance Trouble Shooting Environmental Protection CE Declaration of Conformity Glue Applicators Spare Parts Technical Data Accessories MS 80 MS 150 own ow A O 10 11 14 16 Product Description rekam Dear customer the glue applicator you purchased will help you to glue parts together more easily and more rapidly To ensure an optimum usage of the glue applicator we recommend that you read these instructions thoroughly before using the applicator for the first time The type of your applicator can be taken from the nameplate fitted to the side of the casing Ger te Typ Type Leistung Power Spannung 230V 110V Voltage 50Hz 50Hz Pros O Press max Made in Germany Mm Eggenstein Leopoldshafen December 1 2009 Indended Use The applicator works with hot glue which is dispensed by a mechanical conveying system Therefore this glue applicator should only be used by qualified persons who have been familiarized with the proper use and the safety precautions Handling the applicator properly will avoid unnecessary accident hazards and problems Bodily injury or material damage caused by not using the glue applicator as intended shall not b
12. st not be laid on its side Do not open the lid before the applicator has warmed up A N A When your skin got into contact with hot glue cool it with cold water immediately Do not try to remove the hot melt from the skin first If necessary consult a doctor When hot adhesive got into your eyes im mediately cool them under running water for about 15 minutes Consult your doctor at once A Make yourself familiar with applicator first Apply a little glue in varying forms on a piece of paper or card board for example dots and beads Always keep the working temperature of the specific hot melt glue This temperature is indicated in the technical datasheet of the hot melt glue The quantity to be applied is determined by pressing the trigger the longer you press the more glue flows out rekam Replacement of Nozzles A Warning risk of burns When your skin got into contact with hot glue cool it with cold water immediately Do not try to remove the hot melt from the skin first If necessary consult a doctor When hot adhesive got into your eyes im mediately cool them under running water for about 15 minutes Consult your doctor at once 06 For your own safety wear protective gloves and safety goggles when you replace nozzles Ne I N A Always unplug the applicator before replacing a nozzle A Only replace nozzles when the glue applicator is warm
Download Pdf Manuals