1. Additional Function Mode In order to enter the additional function mode first press buttons L and E simultane ously Then switch from one additional function to the other by pressing button E In order to quit the additional function mode press buttons L and E simultaneously 1 Length of the Relay Impulse After switching to the impulse menu an left and the impulse length in seconds right is displayed A standard value of 1 sec is set at the factory l l You can set another impulse length between 1 and 99 seconds If no relay impulse shall be generated select the impulse length 0 1 Using the middle and or right 4 button select the desired impulse length in s The display flashes 2 Confirm the new impulse length by press ing button L Once the new value has been memorized the display stops flashing Note This is how to end programming without saving data e Switch to the next additional function press button E e Switch to operating mode press buttons L and E simultaneously 2 Blocking Specific Memory Locations After switching to the blocking menu the memory location 001 is displayed PPro Lio of Using the 4 buttons select the memory location to be blocked a The current status of the memory location is displayed via the two LEDs LED L and LED E OCCU non blocke pied occupied d LED OFF ON ON L
2. 49 0 33 75 90 37 90 Internet www eldat de E Mail info eldat de 87274 1108 GB Fig 1 Lie LED L E LED E Ale Display 24V AC DC Relay Controlled Device Radio Access Control RCAO2 Operating instructions ELDATY Operating Instructions Model RCA02 4101M 01 433 92 MHz RCA02 5001M 01 868 30 MHz Scope of Delivery Radio Access Control PG screw fittings set Mounting accessories Safety Advice Before connecting and starting up the unit carefully read through the operating instructions We will not accept any liability for personal injury or damage to property caused by failure to observe the operating instructions and in particular the safety advice Caution Electrical installation may only be carried out by a qualified electrician While installing make sure that the elec tric circuit into which the radio access control is to be integrated is at zero voltage Warning When being programmed the Radio Access Control is live Programming may only be performed with the protective cover installed Do not make any unauthorized alterations or modifications to the unit Have faulty units checked by the manufac turer Intended Use The RCAO2 Radio Access C
3. LED ON OFF ON E In order to alter the status of the selected memory location press button L e Case a memory location is occupied gt memory location is blocked e Case b memory location is blocked gt blocking is cancelled Note It is not possible to block non occupied mem ory locations Note This is how to end programming without saving data e Switch to the next additional function press button E e Switch to operating mode press buttons L and E simultaneously 3 Function Test After switching to the function text menu F is displayed and the set impulse length of the relay impulse in seconds C l Press button L The radio access control generates a relay impulse and the relay is switched The display flashes for the period of the impulse length Note This is how to end programming without saving data e Switch to the next additional function press button E e Switch to operating mode press buttons L and E simultaneously 87274 1108 GB Operating Instructions Function Modes There are three function modes e Operating Mode e Learn Delete Mode e Additional Function Mode Operating Mode Details in chapter Operating Mode In the operating mode the access control receives radio telegrams and generates a relay impulse Learn Delete Mode Details in chapter Learn Delete Mode In the learn delete mode you can memorize transmitter
4. Operating Instructions Technical Details Frequency Power supply Current consumption Relay output Max contact rating Opertg temperature Type of protection Dimensions Weight Disposal 868 3 MHz or 433 92 MHz 24 V AC DC 10 approx 3 VA 1 relay contact N O DC max 60 V max 1 A max 30 W 20T to 606 IP66 180 x 94 x 59 mm approx 480 g Waste electrical products may not be disposed of with household waste Dispose of the waste product via a KS collection point for electronic scrap z or via your specialist dealer C3 Put the packaging material into the 4y recycling bins for cardboard paper A and plastics Warranty Within the statutory warranty period we under take to rectify free of charge by repair or replacement any product defects arising from material or production faults Any unauthorized tampering with or modifica tions to the product shall render this warranty null and void Conformity This product complies with the essential requirements of the C R amp TTE Directive 1999 5 EC The Declaration of Conformity can be ac quired from the supplier referred to in the delivery documents Customer Service If despite correct handling faults or malfunc tions occur or if the product was damaged please contact the company at the address below ELDAT GmbH Im Gewerbepark 14 15711 Zeesen Deutschland Telefon 49 0 33 75 90 37 310 Telefax
5. al Function Mode gt Entering Altering the Numerical Code the display flashes 000 Lio LI Select the code using the buttons and press button L When the correct code is entered the first non occupied memory loca tion is displayed Memorizing Transmitter Telegrams A Memorizing automatically 1 Press one of the 4 buttons once The first non occupied memory location is displayed 2 Press button L for 1 sec LED L flashes for 30 s During this time a transmitter telegram can be memorized 3 Press the button of the transmitter which code is to be memorized Once the Radio Access Control has memorized the transmitter telegram rdy is displayed LNL LI l E m aa oe After approx 2 s the next free memory location is displayed 4 If you want to memorize additional trans mitter telegrams please repeat Step 2 and Step 3 Switch to operating mode press buttons L and E simultaneously B Memorizing manually 1 Use the 4 buttons to select the desired memory location Note If you selected a memory location already used the error message err is displayed Afterwards a free memory lo cation is suggested 87274 1108 GB Operating Instructions 2 Press button L for 1s LED L flashes for 30 s During this time a transmitter telegram can be memorized 3 Press the button of the transmitter which code is to be memorized Once the radio access control has mem
6. ontrol is exclu sively developed and manufactured as a receiving unit for 48 bit radio telegrams The manufacturer does not assume any liability for damage caused as a result of improper or non intended use General Information The Radio Access Control works within a frequency range which is also used by other radio services The operation and range can therefore be affected by devices working on the same or an adjacent frequency The reception quality can be affected by a number of factors e location e equipment and systems without interfer ence suppression e other transmitters within the frequency range e atmospheric conditions and other factors In the case of malfunctions contact your specialist dealer or the manufacturer Function The RCAO2 Radio Access Control is an 868 MHz or 433 MHz receiving unit It receives up to 700 individual 48 bit telegrams When a memorized radio telegram is re ceived a relay impulse is generated and a relay is switched 87274 1108 GB Operating Instructions 4 History After switching to the history menu H__ Is displayed CL Press the right button Each time the button is pressed the memory location numbers of the last 10 telegrams are displayed counting down Note This is how to end programming without saving data e Switch to the next additional function press button E e Switch to operating mode press buttons L and E simultaneou
7. orized the trans mitter telegram rdy is displayed ILI ho y After approx 2 s the next free memory lo cation is displayed 4 If you want to memorize additional trans mitter telegrams please repeat Step 1 and Step 3 Switch to operating mode press buttons L and E simultaneously Notes If no button is pressed on the transmit ter within time of learning after 30 s the error message err appears for approx 3 s CHO You can abort and quit the programming within the time of learning and return to the operating mode by pressing button L The display will show rdy for approx 3 s and then ___ Deleting Specific Memory Locations 1 Using the 4 buttons to select the memory location to be deleted 2 Press button E LED E flashes for approx 5s When a transmitter telegram has been deleted rdy is displayed Pay LI L aa fn ea Note It is not possible to delete non occupied or blocked memory locations see chapter Addi tional function mode gt Blocking specific mem ory locations In such instances the error message err is displayed In order to quit the deleting mode press but tons L and E simultaneously
8. sly 5 Deleting the Memory Completely After switching to the Deleting the Memory Completely menu E A is displayed e Press the left and right 4 buttons simulta neously The entire contents of the memory are de leted During the deleting procedure approx 8 s the display flashes Note It is not possible to interrupt the deleting procedure After the deleting procedure e Switch to the next additional function press button E e Switch to operating mode press buttons L and E simultaneously 87274 1108 GB 6 Entering Altering the Numerical Code You can use this function if you want to re lease the programming modes learn delete mode and additional function mode using a numerical code After switching to the numerical code menu C__ is displayed U G How to enter a new numerical code 1 Using the 4 buttons select the desired numerical code 2 Confirm the new code by pressing button l How to delete a numerical code 1 Using the 4 buttons select the numerical code 000 2 Confirm the new code by pressing button bL Note If a code with less than three digits is selected the error message err is displayed yy Co U C Note This is how to end programming without sav ing data e Switch to the next additional function press button E e Switch to operating mode press buttons L and E simultaneously Operating Instructions
9. telegrams and delete specific memory locations Additional Function Mode Details in chapter Additional Function Mode The additional function mode offers the fol lowing additional functions Additional Function Display Application 1 Length of the relay impulse l Changing the impulse length of the relay impulse standard value 1 sec or deactivating the relay output 2 Blocking specific memory locations e g 001 Time limited access authorization for par ticular visitors 3 Function test F Generating a relay impulse 4 History H Display of the last 10 telegrams 5 Deleting the memory completely E A Reprogramming the radio control 6 Entering altering the numerical code C Release of programming modes learn delete mode and additional function mode using a numerical code 87274 1108 GB Operating Instructions Mounting and Connecting 1 Unscrew the housing cover 2 Remove the protective cover 3 Mount the Radio Access Control 4 Connect the device to be switched e g garage door opener to the ST2 con necting terminals see title fig 1 5 Connect the power supply cable to the ST1 connecting terminals see title fig 1 The permissible supply voltage is 24 V AC DC 10 Note All the cables must be fed into the device via the M 16 20 openings using watertight PG screw fittings supplied with the Radio Access Control 6 Screw on again the co
10. ver plate Start Up 1 Switch on the supply voltage The Radio Access Control first carries out an LED check _ Is displayed The Radio Access Control is then in the operating mode see also section Op erating Mode 1 Ifa relay impulse is longer than 1 sec or no relay impulse should be transmitted Change the preset impulse length The details are in the chapter Additional Function Mode gt Length of the Relay Impulse 2 Memorize the individual transmitter telegrams into the Radio Access Control The details are in the chapter Learn Delete Mode gt Memorizing Transmitter Telegrams 3 If needed set additional functions For this read the chapter Additional Function Mode 4 Switch back to operating mode by pressing buttons L and E simulta neously The Radio Access Control is now ready to operate 5 Screw on the housing cover Operating Mode When a radio telegram is received LED L lights up After receiving a memorized telegram e the memory location of the telegram is displayed e arelay impulse is generated 87274 1108 GB Learn Delete Mode In the Learn Delete Mode you can memorize a total of 700 individual transmitter telegrams memory locations 000 to 699 or you can delete specific memory locations Note If you have protected access to the programming modes Learn Delete Mode and Additional Function Mode with a numerical code see chapter Addition