Stinger 0136250 Use and Care Manual
Contents
1. OPERATING THE TOOL 1 Read the Owner s Manual prior to using the tool 2 Read warning label s on the tool 3 Visually inspect the tool for worn or damaged parts 4 Wear appropriate eye protection 5 Insert a male pneumatic fitting into the end cap of the tool ensuring that the fitting allows the tool to exhaust any air in the tool when the air hose is disconnected 6 Add 2 drops of non detergent 20 weight oil into the male fitting daily 7 Connect the air hose using a quick connect fitting to the tool and check the air pressure reading on the regulator to ensure it does not exceed 105 PSI Check the tool for any air leaks 8 Place the tool empty of fasteners in operating position on a scrap work piece Fully depress the safety and pull the trigger to verify the tool cycles 9 Disconnect the air hose from the tool when Loading nails and or caps Performing inspection maintenance or repair Clearing a nail or collated cap jam The tool is not in use Leaving the work area Moving the tool to another work location Handing the STINGER CN100 to another person Storing the tool 10 Following recommended loading instructions load the fasteners approved for use in the tool 11 12 13 OPERATING THE TOOL Cycle the tool on a scrap work piece to evaluate the depth of penetration by the fastener into the work piece To adjust the depth of penetration regulate the air pressure at the regulator and or disc
2. national nail corp more than just nails CN100 CAP NAILER OWNER S MANUAL e Operation e Maintenance e Safety e Warranty PLEASE READ This manual contains important information about product safety REV 12 11 S x D oo fa kr 3 z s TABLE OF CONTENTS Important Information Warnings Tool Specifications Loading the Tool Operating the Tool STINGER CN100 Schematic STINGER CN100 Parts List Maintenance and Storage Warranty Troubleshooting 10 13 14 15 IMPORTANT INFORMATION Please take the time to read and understand the information contained in the Owner s Manual included with this product before operating or maintaining the STINGER CN100 Cap Nailer Improper use of this tool could result in serious injury or even death Most accidents occur because of the failure to observe basic safety rules and precautions Basic safety precautions are outlined in the Warnings section of this manual This product is intended for securing synthetic underlayments roofing felt and housewraps WARNINGS PERSONAL SAFETY ITEMS e Reading the Owner s Manual prior to using the tool e Always wear eye protection that conforms to ANSI requirements Z87 1 and provides protection against flying particles both from the front and side Eye protection should be worn by the operator and by others in the work area to protect against flying fasteners and debris that could possibly cause seve
3. Spring Feed Piston Cover Magazine Screw M5 45 Magazine Cover Screw 2 Spring Check Pawl Spring Door Pin Pin Door Latch Spring Pin Parts included in AS 97377 O Ring and Seal Kit 12 MAINTENANCE amp STORAGE MAINTENANCE 1 Disconnect the air hose from the tool when performing inspections maintenance or repairs 2 Use air line lubricators f lubricators are not available or if hose lengths exceed 10 feet add 2 drops of non detergent 20 weight oil daily into the air inlet of the tool 3 Whenever repairs or replacement of parts inside the body occur check the piston O ring for adequate grease lubrication 4 Never use any parts other than genuine STINGER replacement parts 5 Periodically clean the nose of the tool with a mild solvent STORAGE 1 Disconnect the air hose when storing the tool 2 Never store the tool in cold weather environments for any duration of time as any frost or ice formation in the tool will cause tool failures 3 For prolonged storage add 2 drops of oil to the air inlet of the tool prior to discontinuing use Also clean the exterior of the tool with a mild solvent 13 WARRANTY WARRANTY ITEMS 1 Warranty for cap assemblies castings and housing castings is one year 2 Warranty for bumpers O rings driver blades and piston rings is not applicable as they are normal wearing parts whose life is dependant on application 3 Warranty for all other pa
4. 00 746 5659 15 Contact Inside Sales at 800 746 5659 to place an order for replacement parts Visit our website at www stingerworld com to learn more about our products and services national nail corp more than just nails 2964 Clydon SW Grand Rapids MI 49519 USA Phone 800 968 6245 Fax 616 531 5970 www nationalnail com TI ZT AJY z Z lt 5 gt oa D lt S e e 3
5. 7983 0137984 0137932 0137942 0137985 0137943 0137964 0137902 0137911 0137994 0137933 0136955 0137907 0137970 0137988 0137974 0137934 0137929 0137918 0137961 0137919 0137920 0137921 0137957 0137925 0137935 0137950 0137955 0137958 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 Description O Ring Trigger Valve A O Ring O Ring Trigger Valve B O Ring O Ring Spring Plunger O Ring 2 Trigger Valve Housing Safety Safety Assembly Pin Cap Feeder Spring Barb Fitting 2 Feed Cylinder O Ring 2 Feed Piston O Ring 2 Spring Piston Step 2 Feed Piston Cover Retaining Ring 2 Magazine Right Magazine Cover Magazine Left Lock Nut Feed Chute Hold Down Spring Screw 2 Lock Nut 2 Washer 2 Parts included in AS 97377 O Ring and Seal Kit 11 STINGER CN100 PARTS LIST Item No Ref No 0137926 0137956 0137951 0137912 0137992 0137948 0137952 0137996 0137987 0137913 0137946 0137917 0137906 0137989 0137936 0137922 0137924 0137954 0137923 0137947 0137937 0137944 0137938 0137993 0137914 0137915 0137945 0137939 0137916 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 Description Bracket Nut Screw Pin Nail Support Screw 3 Screw 2 Tubing Rubber Washer Pin Screw Nose Feed Pawl Feed Piston
6. Use a pressure regulator and gauge to allow visual inspection of the air pressure being delivered to the tool Use air hoses that have rated pressures of up to 150 of the maximum pressure that can be generated by the power source The supply hose should contain 1 4 fittings that will provide quick disconnecting from the male plug on the tool Use quick connect fittings that allow the tool to be unhooked from the air supply quickly and easily Do not use fittings that will not allow the tool to exhaust when the air supply is disconnected WARNINGS OPERATION OF THE TOOL e Never inspect maintain repair adjust clear a jam or store the tool with the air connected e Never use the tool in proximity of flammable gases or liquids as some tools will create sparks that can be an ignition source for a fire or explosion e Always inspect the safety device for damage and proper operation prior to operation e Never assume the tool is empty of fasteners e Never point the tool toward yourself or any other persons e Never cycle the tool unless it is in contact with the work piece e Never use the tool as a hammer or wedging device or drop to the floor from any height e Always remove your finger from the trigger when pausing from cycling e Never tamper with the safety device or use the tool if the safety device is not functioning properly e Use only 1 STINGER NailPac cap nails with the STINGER CN100 Cap Nailer Never use any f
7. asteners that are not specified for use in this tool The CN100 holds 1 roll of plastic caps 200 caps and 1 coil of nails 200 nails each TOOL SPECIFICATIONS Operating pressure Weight Nail capacity Cap capacity Air inlet Fasteners 95 105 psi 4 9 Ib 200 nails 1 200 count coil 200 plastic collated caps 1 200 count roll 1 4 STINGER NailPac National Nail product number 136260 includes 10 coils of 1 EG ring shank nails 200 nails per coil and 10 rolls of 1 diameter plastic collated caps 200 caps per roll LOADING THE TOOL USE 1 STINGER NAILPAC CAP NAILS ONLY Disconnect air e Open the cap magazine cover by pushing the green cover release tab and lifting Place cap roll in basket Make sure the front end of the cap roll is placed over the cap guide area of the basket Insert lead cap into the feed chute Slide caps along the feed chute with fingers until they engage the cap feeder Pull the cap feeder back and release to advance caps until the first cap is under the nose of the tool Close the magazine cover e Depress the latch on the nail gate and basket cover Open nail gate Open nail basket cover Place one nail coil in basket so it fits securely around center post Insert lead nail into nose Lay following nails flat onto feeder pawls e Close nail basket cover Close nail gate Be sure latch is securely fastened Plug into air source Tool is ready to use
8. onnect the air hose adjust the depth control screw connect the air hose and cycle the tool on a scrap work piece to evaluate the adjustment Repeat Step 12 as needed to set the correct depth using the minimum amount of air pressure to drive the fastener STINGER CN100 SCHEMATIC Q HB QOQQD DO O 0 So E 3 awe Sosa OOO QQ ON OOOOQQ OQO 0B 00000 IDO 4 15 11 STINGER CN100 PARTS LIST Item No Ref No 0137949 0137991 0137990 0137973 0137959 0137953 0137960 0137965 0137928 0137975 0137931 0137968 0137967 0137976 0137979 0137905 0137908 0137969 0137977 0137978 0137900 0137927 0137966 0137904 0137971 0137972 0137986 0137909 0137963 0137930 0137962 0137995 0137901 0137910 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 Description Screw Washer Exhaust Deflector O Ring Washer Cap Screw Flat Washer Cap Exhaust Seal O Ring Poppet Spring Poppet O Ring Poppet Piston Stop O Ring Cylinder Seal O Ring Guide Spacer Cylinder Cylinder O Ring Cylinder O Ring Piston O Ring Piston amp Driver Assembly Bumper Gasket Body O Ring O Ring O Ring 3 Pin Safety Guide Spring Washer Belt Clip Trigger Assembly Pin Parts included in AS 97377 O Ring and Seal Kit 10 STINGER CN100 PARTS LIST Item No Ref No 0137980 0137940 0137981 0137982 0137941 013
9. re eye injury e The employer is responsible for enforcing the use of eye protection equipment by the tool operator and all other personnel in the work area e To prevent accidental injuries Handle the tool with care Always assume that the tool contains fasteners Always disconnect the air hose from the STINGER CN100 when e loading nails and or caps e performing inspection maintenance or repair e clearing a nail or collated cap jam e the tool is not in use e leaving the work area e moving the STINGER CN100 to another work location e handing the STINGER CN100 to another person e storing the tool Never point the tool toward yourself or anyone else Never engage in horseplay when handling the tool Never hold or carry the tool with a finger on the trigger Never place a hand or any other part of the body in the fastener discharge area of the tool while the air supply is connected WARNINGS AIR SUPPLY AND CONNECTIONS Use only clean regulated compressed air as a power source for this tool Do not use bottle gases combustible gases or oxygen as a power source for the tool as the tool may explode Do not use air supply pressures that exceed 105 PSI Do not exceed the recommended maximum operating air pressure as tool wear will be greatly increased The air supply must be capable of maintaining the operating air pressure of the tool Pressure drops in the air supply can reduce the tool s driving power
10. rts is 90 days WARRANTY CONDITIONS 1 The beginning date on which the warranty is in force is the date of purchase 2 The warranty is not transferable 3 The warranty is voided by any of the following a Abuse misuse or damage to the tool b Use of parts other than genuine STINGER parts c Use of fasteners not designated for use in the tool d Modifications to the tool that alter the original function or intent of use of the tool by anyone other than National Nail Corp 4 National Nail Corp retains the right to replace or repair any warranty items it deems necessary 14 TROUBLESHOOTING Disconnect the air hose from the tool when performing inspections maintenance or repairs PROBLEM 1 Tool operates but no fasteners are driven 2 Cap leaks air 3 Fasteners jam in nose of tool 4 Skipping fasteners 5 Fasteners will not drive completely into work piece CORRECTION Check magazine for proper fasteners Fasteners should slide freely in and out of the magazine Tighten cap screws Un plug tool from air supply Open nail gate Remove fasteners from magazine Remove jammed fastener and close nail gate Load tool Replace bumper if worn Use only recommended fastener size Check air supply as it may be too low or on too high Increase air pressure do not exceed 105 PSI Check depth of drive setting Please contact Inside Sales for technical support if you have any other problems 8