Home
Campbell Hausfeld RP320000AV Use and Care Manual
Contents
1. See Warranty on page 4 for important information about commercial use of this product Operating Instructions RP3200 Please read and save these instructions Read carefully before attempting to assemble install operate or maintain the product described Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury and or property damage Retain instructions for future reference A 12 Volt Inflator Description Hose Cord The RP3200 12 volt inflator is intended Accessory for emergency roadside tire inflation Storage Y and to inflate bicycle tires soccer balls and other sports equipment The inflator includes an auto shut off gauge that shuts the unit off at the desired pressure and a light Automatic shut off gauge Unpacking After unpacking the unit inspect carefully for any damage that may have occurred during transit Safety Guidelines This manual contains information that is very important to know and understand This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS To help recognize this information observe the following symbols ta Penger indicates Important Safety Instructions Specifications an imminently Figure 1 hazardous situation which if not ANY MISUSE OF UNIT COULD CAUSE Maximum Pressure 140 psi avoided WILL result
2. 11 Sp Manual de Instrucciones de Operaci n RP3200 Garant a Limitada 1 9 DURACION A partir de la fecha de compra por el comprador original tal como se especifica a continuaci n Un 1 a o QUIEN OTORGA ESTA GARANTIA EL GARANTE Campbell Hausfeld The Scott Fetzer Company 100 Production Drive Harrison Ohio 45030 Tel fono 800 543 6400 QUIEN RECIBE ESTA GARANTIA EL COMPRADOR El comprador original que no sea un revendedor del producto Campbell Hausfeld PRODUCTOS CUBIERTOS POR ESTA GARANTIA Cualquier clavadora grapadora herramienta neum tica pistola pulverizadora inflador o accesorio neum tico suministrado o fabricado por el Garante COBERTURA DE LA GARANTIA Los defectos substanciales de material y fabricaci n que ocurran dentro del per odo de validez de la garant a LO QUE NO ESTA CUBIERTO POR ESTA GARANTIA A Las garant as impl citas incluyendo aquellas de comercialidad E IDONEIDAD PARA FINES PARTICULARES ESTAN LIMITADOS A LO ESPECIFICADO EN EL PARRAFO DE DURACION Si este producto es empleado para uso comercial industrial o para renta la garant a ser aplicable por noventa 90 d as a partir de la fecha de compra En algunos estados no se permiten limitaciones a la duraci n de las garant as impl citas por lo tanto en tales casos esta limitaci n no es aplicable B CUALQUIER PERDIDA DA O INCIDENTAL INDIRECTO O CONSECUENTE QUE PUEDA RESULTAR DE UN DEFECTO FALLA O MALFUNCI
3. a Adj ntela a este manual o arch vela en lugar seguro O 2009 Campbell Hausfeld Scott Fetzer 9 Sp IN299501AV 8 09 Manual de Instrucciones de Operaci n RP3200 Instrucciones de Seguridad Importantes Cont No deje el inflador ADVERTENCIA sin vigilar mientras la unidad est funcionando Nunca ADVERTENCIA ons la presi n recomendada para cualquier objeto inflable No infle demasiado los objetos El inflar con exceso podr a causar da os a la propiedad ylo heridas personales El adaptador ADVERTENCIA universal debe estar cerrado para asegurar los accesorios del inflador Tenga extremada precauci n cuando use accesorios de inflar Siempre pongale ADVERTENCIA el freno de emergencia y asegure las llantas antes de usar el inflador o podria resultar en heridas ylo da os a sus propiedades Siempre use un A PRECAUCION man metro aparte para revisar la presi n de las llantas y objetos inflamables a baja presi n PRECAUCION El inflador debe enfriarse por 20 minutos despues de 20 minutos de uso continuo El inflador no esta disenado para operar continuamente por mas de 20 minutos No use el inflador AVISO para las llantas de alta presi n usado en los camiones grandes caravanas o tractores El inflador no est dise ado para funcionar por el tiempo necesario para inflar estas llantas Aseg rese de que AVISO el adaptador universal toque el n cleo del
4. pneumatiques pistolets vaporisateurs gonfleurs ou accessoires pneumatiques Campbell Hausfeld qui sont fournis par ou fabriqu s par le Garant COUVERTURE DE LA PR SENTE GARANTIE D fauts de mati re et de fabrication consid rables qui se r v lent pendant la p riode de validit de la garantie LA PR SENTE GARANTIE NE COUVRE PAS A Les garanties implicites y compris celles de commercialisabilit et D ADAPTION UNE FONCTION PARTICULI RE SONT LIMIT ES PARTIR DE LA DATE D ACHAT INITIALE TELLE QU INDIQU E DANS LA SECTION DUR E Si ce produit est utilis pour une fonction commerciale industrielle ou pour la location la dur e de la garantie sera quatre vingt dix 90 jours compt de la date d achat Quelques Provinces tats n autorisent pas de limitations de dur e pour les garanties implicites Les limitations pr c dentes peuvent donc ne pas s appliquer B TOUT DOMMAGE PERTE OU D PENSE FORTUIT OU INDIRECT POUVANT R SULTER DE TOUT D FAUT PANNE OU MAUVAIS FONCTIONNEMENT DU PRODUIT CAMPBELL HAUSFELD Quelques Provinces tats n autorisent pas l exclusion ni la limitation des dommages fortuits ou indirects La limitation ou exclusion pr c dente peut donc ne pas s appliquer C Toute panne r sultant d un accident d une utilisation abusive de la n gligence ou d une utilisation ne respectant pas les instructions donn es dans le s manuel s accompagnant le produit Un accident l utilisation abusive par l acheteu
5. in death or serious PROPERTY OR EQUIPMENT DAMAGE Continuous 0 66 SCFM 0 psi injury AND OR PERSONAL INJURY P a Volume aa 0 54 SCFM 30 psi A WARNING Warning indicates This manual contains safety operational Ja potentially and maintenance information Contact O cette sts mene 3 0 Ibs de pole Aik A your Campbell Hausfeld representative Voltage 2 12 Volt DC serious injury if you have any questions Condilengthie ear 11 feet Caution indicates CALIFORNIA PROPOSITION 65 Air Outlet Universal Adapter A CAUTION a potentially This product or hazardous situation which if not WARNING die e 10 Amp avoided MAY result in minor or moderate injury contain chemicals known to the State of California to cause cancer and birth b Be thoroughly familiar with the NOTICE Notice indicates defects or other reproductive harm controls and the proper use of the important Wash hands after handling E information that if not followed may equipment Follow all instructions cause damage to equipment GENERAL Contact your Campbell Hausfeld NOTE Information that requires special a To reduce the risks of representative if you have any attention electric shock fire and a questions injury to persons read all pe c Only persons well acquainted with the instructions before these rules of safe operation should using the unit be allowed to use the unit REMINDER Keep your dated proof of
6. une preuve d achat dat e et un tat d entretien B Appelez Campbell Hausfeld 800 543 6400 pour obtenir vos options de service sous garantie Les frais de transport sont la responsabilit de l acheteur C Utilisation et entretien du produit avec un soin raisonable ainsi que le d cri vent t le s manuel s d utilisation R PARATION O REMPLACEMENT EFFECTU PAR LE GARANT AUX TERMES DE LA PR SENTE GARANTIE La r paration ou le remplacement sera pr vu et ex cut en fonction de la charge de travail dans le centre de service et d pendra de la disponabilit des pi ces de rechange Cette Garantie Limit e s applique aux U au Canada et au Mexique seulement et vous donne des droits juridiques pr cis L acheteur peut galement jouir d autres droits qui varient d une Province d un Etat ou d un Pays l autre 8 Fr Ver la Garant a en p gina 12 para informaci n importante sobre el uso comercial de este producto Manual de Instrucciones de Operaci n RP3200 Por favor lea y guarde estas instrucciones L alas cuidadosamente antes de tratar de montar instalar operar o dar mantenimiento al producto aqu descrito Prot jase usted mismo y a los dem s observando toda la informaci n de seguridad El no cumplir con las instrucciones puede ocasionar da os tanto personales como a la propiedad Guarde estas instrucciones para referencia en el futuro CAMPBELL HAUSFELD Inflador de 12 Voltios De
7. v stago de v lvula de la llanta Instrucciones de Funcionamiento Para usar con AVISO salidas de CC de 12 voltios clasificadas para 10 amp o m s No usar con tomas antiguas de encendedor de cigarrillos de 8 amperios Inflar m s de lo requerido puede ser peligroso Preste atenci n al inflar art culos de presi n baja para prevenir el inflado excesivo NEUM TICOS 1 Quite la tapa del v stago de la v lvula 2 Coloque el adaptador universal vea la Figura 2 desde el inflador hasta el v stago de la v lvula con la palanca hacia arriba Aseg rese de presionar hacia abajo completamente el adaptador universal sobre las roscas del v stago de la v lvula Cuando el adaptador universal est firmemente en su lugar presione la palanca de trabado hacia abajo para fijarlo sobre el v stago de la v lvula 3 Enchufe el cord n de energ a en el recept culo del encendedor de cigarrillos 4 Ajuste el man metro de corte autom tico girando el anillo que se encuentra en el mismo hasta que el borde inferior del puntero se encuentre justo encima de la presi n deseada vea la Figura 3 Es posible que sea AVISO necesario ajustar el puntero entre 0 14 bar y 0 21 bar m s que la presi n deseada para evitar que la unidad se apague prematuramente 5 Encienda el inflador y espere hasta que ste se apague
8. 6 Verifique que la presi n del neum tico sea la correcta 7 Para agregar m s presi n de aire ajuste el apagado a una presi n mayor y apague la energ a con el interruptor y luego vuelva a encender el inflador INSTRUCCIONES DE USO Y MANTENIMIENTO REEMPLAZO DEL FUSIBLE NUNCA utilice un fusible de m s de 10 A para reemplazar el fusible de esta unidad 1 Desenrosque el extremo del enchufe hacia la izquierda para sacar el fusible 2 Si el fusible est quemado reempl celo con un fusible nuevo de 10 amperes Siempre reemplace un fusible quemado con un fusible del mismo tama o 3 Vuelva a armar el enchufe No apriete en exceso SERVICIO T CNICO Para mayor informaci n en relaci n al funcionamiento o reparaci n de este producto comun quese con el concesionario de Campbell Hausfeld m s cercano a su domicilio PARA REPARAR LA UNIDAD La unidad deber ser reparada nicamente por personal calificado y deber n usar piezas de repuesto y accesorios originales Campbell Hausfeld O piezas y accesorios que funcionen de manera equivalente ALMACENAMIENTO La unidad debe guardarse en un lugar fresco y seco Abro Seguro Adaptador Universal V stago de v lvula Figura 2 Figura 3 Corte fijado para 2 07 bar 10 Sp Manual de Instrucciones de Operaci n RP3200 Notas
9. ONAMIENTO DEL PRODUCTO CAMPBELL HAUSFELD En algunos estados no se permite la exclusi n o limitaci n de da os incidentales o consecuentes por lo tanto en tales casos esta limitaci n o exclusi n no es aplicable C Cualquier falla que resulte de un accidente abuso negligencia o incumplimiento de las instrucciones de funcionamiento y uso indicadas en el los manual es que se adjunta n al producto Dichos accidentes abusos por parte del comprador o falta de operar el producto siguiendo las instrucciones del manual de instrucciones suministrado tambi n debe incluir la desconexi n o modificaci n de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garant a quedar a cancelada D Los ajustes normales explicados en el los manual es suministrado s con el producto E Art culos o servicios normalmente requeridos para el mantenimiento del producto tales como anillos en O resortes amortiguadores defensas hojas de impulsor fusibles bater as empaques almohadillas o sellos boquillas de flu do agujas boquillas para rociar arena lubricantes mangueras de material elementos filtrantes labes de motores abrasivos hojillas discos para cortar cinceles retenes para cinceles cortadores collarines mandriles mordazas para remachadoras brocas para desarmadores almohadillas para lijar soportes de almohadillas mecanismo de impacto o cualquier otro art culo desgastable que no se haya enumer
10. Toujours remplacer un fusible grill par un fusible de m me taille 3 Remonter la fiche Ne pas trop serrer SUPPORT TECHNIQUE Pour tout renseignement sur le fonctionnement ou la r paration de cet outil veuillez utiliser notre num ro d assistance 1 800 543 6400 ou pour obtenir d autres copies de ce manuel R PARATION DE LA L UNIT Seul le personnel d ment qualifi devrait r parer l unit en utilisant des pi ces de rechange et des accessoires Campbell Hausfeld authentiques ou des pi ces et accessoires qui fonctionnent de mani re quivalente RANGEMENT L unit doit tre rang dans un endroit frais et sec Ouvrir Verrouiller Adaptateur Universel Tige de Soupape Figure 2 Figure 3 R glage d arr t a 207 kPa 6 Fr Instructions d Utilisation RP3200 Notes 7 Fr Instructions d Utilisation RP3200 Garantie Limit e 1 2 DUR E A partir de la date d achat par l acheteur original comme suit Un An GARANTIE ACCORD E PAR GARANT Campbell Hausfeld Scott Fetzer Company 100 Production Drive Harrison Ohio 45030 T l phone 800 543 6400 B N FICIAIRE DE CETTE GARANTIE ACHETEUR L acheteur original sauf en cas de revente du produit Campbell Hausfeld PRODUITS COUVERTS PAR CETTE GARANTIE Tous les outils de fixation cloueuses et agrafeuses outils
11. a manipulation Sp cifications Pression maximum 965 kPa Volume sans 0 02 m min 0 kPa interruption 0 02 m min 207 kPa ROIS herent eter ete ee 1 36 kg Tension a eaves re 12 volts c c Longueur de cordon 3 35 m Sortie d aire Adaptateur Universel EU e 10 Amp res GENERALITE a Pour r duire les risques de chocs lectriques d incendie ou de blessures aux personnes lire toutes les instructions avant d utiliser l unit b Se familiariser avec ce produit ses commandes et son utilisation Suivez toutes les instructions Contacter votre repr sentant Campbell Hausfeld si vous avez des questions M MENTO Gardez votre preuve dat e d achat fin de la garantie Joignez la ce manuel ou classez la dans un dossier pour plus de s curit 2009 Campbell Hausfeld Scott Fetzer 5 Fr IN299501AV 8 09 Instructions d Utilisation RP3200 Importantes instructions de s curit Suite c Seules les personnes famili res avec ces r gles d utilisation sans danger devraient utiliser cette unit AVERTISSEMENT sans surveillance Ne AVERTISSEMENT ais d passer la pression recommand e d un objet gonflable Ne pas sur gonfler les objets Le sur gonflage peut causer des d g ts mat riels et ou des blessures personnelles Le raccord AVERTISSEMENT universel doit tre barr pour maintenir les accessoires
12. ado espec ficamente Estos art culos s lo estar n cubiertos bajo esta garant a por noventa 90 d as a partir de la fecha de compra original Los art culos subrayados s lo est n garantizados por defectos de material o fabricaci n RESPONSABILIDADES DEL GARANTE BAJO ESTA GARANTIA Reparar o reemplazar como lo decida el Garante los productos o componentes que est n defectuosos se hayan da ado o hayan dejado de funcionar adecuadamente durante el per odo de validez de la garant a RESPONSABILIDADES DEL COMPRADOR BAJO ESTA GARANTIA A Suministrar prueba fechada de compra y la historia de mantenimiento del producto B Llame a Campbell Hausfeld 800 543 6400 por sus opciones de servicio incluidas en la garant a Los costos de flete correr n por cuenta del comprador C Seguir las instrucciones sobre operaci n y mantenimiento del producto tal como se indica n en el los manual es del propietario CUANDO EFECTUARA EL GARANTE LA REPARACION O REEMPLAZO CUBIERTO BAJO ESTA GARANTIA La reparaci n o reemplazo depender del flujo normal de trabajo del centro de servicio y de la disponibilidad de repuestos Esta garant a limitada es v lida s lo en los EE UU Canad y M xico y otorga derechos legales espec ficos Usted tambi n puede tener otros derechos que var an de un Estado a otro o de un pa s a otro 12 Sp
13. ained in the owner s manual s provided with the product E Items or service that are normally required to maintain the product i e o rings springs bumpers debris shields driver blades fuses batteries gaskets packings or seals fluid nozzles needles sandblast nozzles lubricants material hoses filter elements motor vanes abrasives blades cut off wheels chisels chisel retainers cutters collets chucks rivet jaws screw driver bits sanding pads back up pads impact mechanism or any other expendable part not specifically listed These items will only be covered for ninety 90 days from date of original purchase Underlined items are warranted for defects in material and workmanship only RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY Repair or replace at Warrantor s option products or components which are defective have malfunctioned and or failed to conform within duration of the warranty period RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY A Provide dated proof of purchase and maintenance records B Call Campbell Hausfeld 800 543 6400 to obtain your warranty service options Freight costs must be borne by the purchaser C Use reasonable care in the operation and maintenance of the products as described in the owner s manual s WHEN WARRANTOR WILL PERFORM REPAIR OR REPLACEMENT UNDER THIS WARRANTY Repair or replacement will be scheduled and serviced according to the normal work f
14. de gonflage en place solidement Les accessoires de gonflage doivent tre utilis s avec la plus grande Toujours parquer AVERTISSEMENT joujours para mettre le frein de secours et caler les roues avant d utiliser le gonfleur Sinon il y a risque de dommage mat riel etlou blessure Toujours utiliser un ATTENTION autre manom tre pour v rifier la pression actuelle dans les pneus et dans les objets gonflables de pression basse Le gonfleur DOIT se ATTENTION refroidir pendant 20 minutes apr s 20 minutes de fonctionnement continu Le gonfleur n est past con u pour le fonctionnement continu pendant plus que 20 minutes Ne pas utiliser AVIS le gonfleur sur les pneus de haute pression comme ceux de gros camions remorques ou tracteurs Le gonfleur n est pas fabriqu pour fonctionner la dur e de temps n cessaire pour gonfler ces pneus S assurer que AVIS l adaptateur universel touche le noyau de la tige de soupape de pneu Ne pas laisser le gonfleur en marche Fonctionnement utiliser avec des AVIS prises de courant continu de 12 volts d une valeur nominale de 10 amp res ou plus Ne doit pas tre utilis avec les allumecigare plus vieux de 8 amp res Un surgonflage peut tre dangereux Attention en gonflant les articles basse pression pour viter de trop gonfler PNEUS 1 Re
15. er les symboles suivants pour cette information Danger indique A DANGER une situation dangereuse imminente qui MENERA la mort ou des blessures graves si elle n est pas vit e Avertissement AVERTISSEMENT indique une situation potentiellement dangereuse qui si elle n est pas vit e POURRAIT mener la mort ou de graves blessures Attention ATTENTION f digue une situation potentiellement dangereuse qui si elle n est pas vit e PEUT mener des blessures mineures ou mod r es Avis indique AVIS de l information importante qui pourrait endommager l quipement si elle n est pas respect e REMARQUE L information qui exige une attention sp ciale Jauge d arr t automatique Figure 1 Tuyau cordon stockage d accessoires Importantes instructions de s curit TOUTE UTILISATION INCORRECTE DE L UNIT PEUT CAUSER DES DOMMAGES LA PROPRI T OU L QUIPEMENT OU ENCORE DES BLESSURES Ce manuel contient des informations concernant la s curit le fonctionnement et l entretien Contacter votre repr sentant Campbell Hausfeld si vous avez des questions PROPOSITION 65 DE CALIFORNIE Ce produit ou son AVERTISSEMENT cordon peuvent contenir des produits chimiques qui de l avis de l tat de Californie causent le cancer et des anomalies cong nitales ou autres probl mes de reproduction Lavez vous les mains apr s l
16. gun inflator or air accessory supplied or manufactured by Warrantor WHAT IS COVERED UNDER THIS WARRANTY Substantial defects in material and workmanship which occur within the duration of the warranty period WHAT IS NOT COVERED UNDER THIS WARRANTY A Implied warranties including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED FROM THE DATE OF ORIGINAL PURCHASE AS STATED IN THE DURATION If this product is used for commercial industrial or rental purposes the warranty will apply for ninety 90 days from the date of purchase Some States do not allow limitation on how long an implied warranty lasts so the above limitations may not apply to you B ANY INCIDENTAL INDIRECT OR CONSEQUENTIAL LOSS DAMAGE OR EXPENSE THAT MAY RESULT FROM ANY DEFECT FAILURE OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT Some States do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you C Any failure that results from an accident purchaser s abuse neglect or failure to operate products in accordance with instructions provided in the owner s manual s supplied with product Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warranty is void D Normal adjustments which are expl
17. l adapter touches the core or tire valve stem Operation For use with 12 volt NOTICE DC power outlets rated 10 amps or higher Do not use with older 8 amp cigarette lighter receptacles Overinflation can be dangerous Pay attention while inflating low pressure items to prevent overinflation TIRES 1 Remove valve stem cap 2 Attach the universal adapter see Figure 2 from the inflator to the valve stem with the lever in the up position Be sure to press universal adapter down over valve stem threads completely When universal adapter is firmly in place press locking lever down to lock onto valve stem 3 Plug power cord into cigarette lighter receptacle 4 Set automatic shut off gauge by turning ring on gauge until bottom edge of pointer is just above the desired pressure see Figure 3 It may be necessary NOTICE to set pointer 2 3 psi higher than desired pressure to prevent unit from turning off prematurely 5 Turn on inflator and wait until inflator shuts off 6 Check that the tire pressure is correct 7 To add additional air pressure set shut off at higher pressure and turn power switch off and then back on to restart inflator User Maintenance Instructions FUSE REPLACEMENT NEVER replace a blown fuse with a fuse having a higher rating 1 Unscrew end of plug counter clock
18. low at the servicing location and depending on the availability of replacement parts This Limited Warranty applies in the United States Canada and Mexico only and gives you specific legal rights You may also have other rights which vary from state to state or country to country www chpower com 4 Voir la Garantie la page 8 pour de l information importante sur l utilisation commercial de ce produit Instructions d Utilisation RP3200 S il vous plait lire et conserver ces instructions Lire attentivement avant de monter installer utiliser ou de proc der l entretien du produit d crit Se prot ger ainsi que les autres en observant toutes les instructions de s curit sinon il y a risque de blessure et ou d g ts mat riels Conserver ces instructions comme r f rence CAMPBELL HAUSFELD Gonfleur 12 Volts Description Le gonfleur RP3200 de 12 volts est concu pour le gonflage d urgence de pneus a cot de la rue et pour gonfler des pneus de v los des balles de football et d autre quipement sportif Le gonfleur inclut une jauge d arr t automatique qui arr te l unit a la pression d sir e et une lumiere D ballage D s que l appareil est d ball l inspecter attentivement pour tout signe de dommages en transit Directives de S curit Ce manuel contient de l information tr s importante qui est fournie pour la SECURITE et pour EVITER LES PROBLEMES D EQUIPEMENT Recherch
19. purchase for warranty purposes Attach it to this manual or file it for safekeeping 2009 Campbell Hausfeld Scott Fetzer For parts product amp service information IN299501AV 8 09 visit www chpower com Operating Instructions RP3200 Important Safety Instructions Continued Do not leave the A WARNING inflator unattended while the unit is running Never WARNING Ore the recommended pressure for any inflatable object Do not over inflate objects Over inflation could cause property damage andlor personal injury Always put the car WARNING in park set the emergency brake and chock the wheels before using the inflator or property damage andlor personal injury could occur The universal WARNING adapter must be locked to secure the inflation accessories Use extreme caution when using inflation accessories Avoid long extended CAUTION sys use a separate pressure gauge to check the actual pressure in tires and in low pressure inflatable objects Avoid long extended A CAUTION Inflator must cool for 20 minutes after 20 minutes of continuous oper ation The Inflator is not designed to operate continuously for more than 20 minutes The work surface NOTICE Do not use inflator on high pressure tires used on large trucks trailers or tractors The inflator is not designed to operate for the length of time necessary to inflate these tires Make sure the NOTICE universa
20. r la n gligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces appareils de s ret sont enlev s ou modifi s la garantie sera annul e D R glages normaux qui sont expliqu s dans le s manuel s d utilisation accompagnant le produit E Articles ou services qui sont exig s pour l entretien du produit Joints torique ressorts amortisseurs crans de d bris lames d entra nement fusibles batteries joints d tanch it garnitures ou joints buses de fluide aiguilles buses de sablage graisses tuyaux de mat riaux cartouches filtrantes pales de moteur abrasifs lames meules de coupage burins fixe burins coupeuses douilles de serrage mandrins m choires de rivet lames de tournevis tampons de sablage tampons de sauvegarde m canisme de percussion ou toute pi ce qui n est pas indispensable et qui n est pas indiqu e Ces articles seront couverts pour quatre vingt dix 90 jours partir de la date d achat original Les articles soulign s sont garanties pour d fauts de mati re et de fabrication seulement RESPONSABILIT S DU GARANT AUX TERMES DE CETTE GARANTIE R paration ou remplacement au choix du Garant des produits ou pi ces qui se sont r v l s d fectueux pendant la dur e de validit de la garantie RESPONSABILIT S DE L ACHETEUR AUX TERMES DE CETTE GARANTIE A Fournir
21. rucciones de Seguridad Importantes CUALQUIER USO INCORRECTO DE LA UNIDAD PUEDE CAUSAR DA OS MATERIALES O DA OS AL EQUIPO Y O LESIONES PERSONALES Este manual contiene informaci n sobre seguridad funcionamiento y mantenimiento P ngase en contacto con su representante Campbell Hausfeld si tiene alguna pregunta PROPOSICI N 65 DE CALIFORNIA Este producto o A ADVERTENCIA su pct el ctrico puede contener productos quimicos conocidos por el estado de California como causantes de cancer y defectos de nacimiento u otros dafios reproductivos Lave sus manos despu s de usar GENERAL Especificaciones Presi n m xima 9 65 bar Volumen 0 02 m min 0 bar Continuo 0 02 m min 2 07 bar Presta 1 36 kg Voltaje toto 12 voltios cd Largo del cord n 3 35 m Salida de aire Adaptador Universal Fusibles e OS 10 Amp a Para reducir el riesgo de choque el ctrico incendio y lesiones personales lea todas las instrucciones _ antes de usar la unidad b Familiar sece con los controles y el uso adecuado del equipo Siga todas las instrucciones P ngase en contacto con su representante Campbell Hausfeld si tiene alguna pregunta c S lo se les debe permitir usar esta unidad a aquellas personas bien familiarizadas con estas reglas de manejo seguro RECORDATORIO Guarde su comprobante de compra con fecha para fines de la garant
22. scripci n El inflador RP3200 de 12 voltios est concebido para inflar llantas en una emergencia a la orilla de la carretera y para inflar llantas de bicicletas balones de f tbol y otro equipo deportivo El inflador incluye un man metro de apagado autom tico que apaga la unidad cuando alcanza la presi n deseada y una luz Desempaque Al desempacar este producto rev selo con cuidado para cerciorarse de que est en perfecto estado Medidas de Seguridad Este manual contiene informaci n que es muy importante que sepa y comprenda Esta informaci n se la suministramos como medida de SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO Debe reconocer los siguientes s mbolos Peligro indica PELIGRO una situaci n inminentemente peligrosa que si no se evita dar como resultado la muerte o lesiones graves Advertencia ADVERTENCIA indica una situaci n potencialmente peligrosa que si no se evita PODR A ocasionar la muerte o lesiones graves Precauci n PRECAUCION indica una situaci n potencialmente peligrosa que si no se evita PUEDE dar como resultado lesiones leves o moderadas Aviso indica AVISO una informaci n importante que de no seguirla le podr a ocasionar da os al equipo NOTA Informaci n que requiere atenci n especial Man metro de corte autom tico Figura 1 Manguera cord n compartimento de accesorios Inst
23. tirez le capuchon de la soupape 2 Fixez l adaptateur universel voir la Figure 2 du gonfleur la tige de la soupape avec le levier en position vers le haut Assurez vous de presser enti rement l adaptateur vers le bas sur les filets de la tige de la soupape Lorsque l adaptateur universel est bien en place pressez sur le levier de verrouillage vers le bas pour verrouiller sur la tige de la soupape 3 Branchez le cordon d alimentation dans l allume cigare 4 R glez la jauge d arr t en tournant la bague sur la jauge jusqu ce que le bord inf rieur de l indicateur soit juste au dessus de la pression voulue voir Figure 3 Il faudra peut tre AVIS r gler l indicateur de 13 79 kPa 20 69 kPa plus haut que la pression recherch e pour viter que l appareil ne se ferme trop pr matur ument 5 Mettez le gonfleur en marche et attendez qu il se ferme 6 V rifiez si la pression du pneu est correcte 7 Pour ajouter de la pression d air r glez l arr t un niveau de pression plus lev et coupez le courant puis remettez le courant pour faire red marrer le gonfleur Instructions de Maintenance de l Utilisateur REMPLACEMENT DE FUSIBLES NE JAMAIS remplacer un fusible saut avec un fusible d une classification plus lev e 1 D visser l extr mit de la fiche dans le sens antihoraire pour retirer le fusible 2 Si le fusible grille remplacer avec un nouveau fusible de 10 A
24. wise to remove fuse 2 If fuse is blown replace with a new 10 amp fuse Always replace a blown fuse with the same size fuse 3 Reassemble plug Do not overtighten TECHNICAL SERVICE Please call our Tool Hotline at 1 800 543 6400 with any questions regarding the operation or repair of this unit or for additional copies of this manual UNIT REPAIR Only qualified personnel should repair the unit and they should use genuine Campbell Hausfeld replacement parts and accessories or parts and accessories which perform equivalently STORAGE The unit should be stored in a cool dry place Open le Lock a Universal Adapter Valve Stem Figure 2 Figure 3 Shut off set for 30 psi www chpower com Operating Instructions RP3200 Notes 3 www chpower com Operating Instructions RP3200 Limited Warranty 1 2 DURATION From the date of purchase by the original purchaser as follows One 1 Year WHO GIVES THIS WARRANTY WARRANTOR Campbell Hausfeld Scott Fetzer Company 100 Production Drive Harrison Ohio 45030 Telephone 800 543 6400 WHO RECEIVES THIS WARRANTY PURCHASER The original purchaser other than for purposes of resale of the Campbell Hausfeld product WHAT PRODUCTS ARE COVERED BY THIS WARRANTY Any Campbell Hausfeld nailer stapler air tool spray
Download Pdf Manuals
Related Search
Related Contents
Kalorik USK GR 28215 User's Manual Programação User Manual VX4801 Programmable Digital I/O Module 070-9153-03 FILTRI DEFERRIZZATORI AUTOMATICI SERIE: FD/D Model NPO - Depco Pump Company 取扱説明書 e 自警ネットワーク研究会認定 監視ソフトウェア 代理 EYE 20064771 Atmosphere IS GBL R1R1 CD-Chex CD117® Plus XVIIe XVIIIe et XIXe siècle Black & Decker BLBD10PW Use & Care Manual Copyright © All rights reserved.