Home
Emberglow LO18NG Installation Guide
Contents
1. GAS SUPPLY k r i ANL GAS ON OFF GAS VALVE VALVE IN WALL GAS SUPPLY FIREPLACE LINE 4 Figure 3 Gas line installation Prefabricated fireplce Figure 3 Gas line installation Masonry fireplce GAS LOG INSTALLATION See Figure 1 Parts List as a guide to reference part numbers BURNER PAN INSTALLATION NOTE Use pipe compound on all male threads to seal joints A Determine if the fireplace has a right or left hand gas line feed The circular Dimpled hole covering must be knocked out on the appropriate right or left side of the burner pan NOTE Brace pan on workbench when removing burner knockout Strike knockout with nailpunch for easy removal B Locate 3 8 locknut Part 12 and washer Part 21 then fasten KNOCKOUT them to the 3 8 brass orifice elbow Part 11 Do not fasten the K KOU TU E locknut on the flared end ARROWS BURNER PAN C Slide the 3 4 burner support spacer Part 10 over the Dual Burner Figure 5 Burner bar placement Bar Part 9 and move spacer to opposite corner of the gas intake connection See Figure 5 D Secure the intake end of the Dual burner bar Part 9 to the burner pan Part 8 through the knockout hole selected right or left hand with the 3 8 brass orifice elbow Part 11 3 8 locknut Part 12 and washer Part 21 previously assembled in Step B See Figure 6 E Tighten elbow until firmly attached to the Dual burner bar Then firmly ti
2. the damper open at a distance of not less than 1 1 2 Damper must be full open position anytime this unit is in operation C Prior to connecting the gas log set make sure that the gas supply to the fireplace is completely shut off ZZZZITIT PREFABRICATED MASONRY FIREPLACE FIREPLACE Figure 2 Damper stop clamp Installation of this Energy Efficient Gas Log Set and provisions for combustion and ventilation air must conform with the National Fuel Gas Code ANSI Z21 84 and appliance local codes 3 D Prefabricated fireplace Refer to the manufactures fireplace instruction manual for specific information regarding the running of a gas line into that particular model A typical prefab installation involves the insertion of a 1 2 inch gas pipe through the gas line tube provided by each manufacturer from outside the fireplace The Knockout on the inside of the fireplace is removed as the gas pipe is punched through the fireplace E Masonry fireplace A 1 2 inch gas supply line must be provided to the firebox Most installation require drilling an access hole through the masonry wall The supply line should be secured and sealed by mortar within the access hole The supply line should also have an on off valve either in the wall or inside the fireplace See Figure 4 BACK WALL GAS SUPPLY LINE Va j GAS ON OFF VALVE INSIDE GAS SUPPLY FIREBOX LINE Va VALVE i REPACK MOUNTED IN WALL INSULATION REPACK INSULATION
3. 13 PLUG FLARED END RIGHT SIDE KNOCKOUT PLUG ART NUMBER ZO 8 SET WIP 200 90556 WIP 200 90502 WIP 190 90521 RMH 120 00420 WIP 120 00350 RMH 120 00963 X RMH 120 00100 WIP 120 90426 WIP 130 00010 WIP 130 00300 WIP 190 90560 RCSZZ00008A RMH 130 00588 RCOPZ00007A BURNER BAR po Peset SET C n pen n RMH 120 00100 f1 RMH 120 00100 1 WIP 130 00300 120 RMH 120 00100 120 1 This gas log set is only to be installed and burned in a fully vented fireplace with a fully functional damper and chimney that is free of any obstructions The fireplace must be constructed of non combustible materials and approved to burn wood WARNING Do not burn wood or other material in any fireplace fitted with a gas log set 2 To operate this gas log set the fireplace damper must be fully opened and locked 3 The smallest or minimum dimension of the chimney flue must be 8 inches in diameter Do not use an Energy Efficient Gas Log Set if it is smaller then 8 inches Do not use an Energy Efficient Gas Log Set if fumes from the burner emerge into the room when the damper is fully open This indicates that there is not adequate draft for our log set and the log set must not be used until fireplace draft is corrected 4 This appliance must be installed with a Damper Stop Clamp Part 14 When operating this gas log set the flue damper must be fully open WARNING mproper use or installation may cause Carbon M
4. INSTALLATION amp OPERATION INSTRUCTION FOR FIREPLACE GAS LOG Model Numbers LO18NG and LO24NG Appliance for use with all styles and sizes of Dual Burner Natural Gas Log Sets Note Installer should leave these instructions with the consumer to retain for future reference D D U U A A T L T L I E B E B R U R U D D N N E E R R PLEASE READ these instructions carefully before you begin to install this gas log set FOR YOUR SAFETY lf you smell gas 1 Open windows 2 Dont touch electrical switches 3 Extinguish any open flame 4 Immediately call your gas supplier Do not store or use gasoline or flammable vapors and liquids in the vicinity of this or any other appliance Do not place clothing or other flammable material on or near the appliance Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room as the appliance SURE HEAT MFG 2008 Mi A Complies with ANSI Z21 84 DUAL BURNER PART LIST GLOWING EMBERS Figure 1 e GRANULES HEAVY WEIGHT BAG NUMBER OF LOGS ARE DETERMINED BY THE SIZE AND MODEL CHOSEN SETS RANGE FROM 4 TO 9 LOGS 18 LIGHT WEIGHT BAG INSTALLATION amp OFELATION INSTRUCTION FOR i Te Eaeatitow MEIPLACE GAS LOG tava a ki mm at a a SSS 10 a TO 1 2 am GAS LINE LEFT SIDE 8 ja KNOCKOUT
5. as burner input Do not hold match in hand See Figure 8 With match burning slowly turn on gas Figure 8 Lighting the log set MAINTENANCE Very little maintenance is required The carbon deposit resulting from combustion is natural and adds to the realistic appearance of the set If carbon becomes excessive it can be lightly brushed or vacuumed away TROUBLE SHOOTING Problem Cause Corrective Action 1 No Ignition Valve not on turn valve on gas line not cleat inspect supply lines for tube links or obstructions 2 Inadequate flame Valve partially closed open valve fully gas line obstruction burner inspection for tube kinks or obstructions log arrangement rearrange logs to desired pattern LIMITED WARRANTY FEN ZAM AD AN ATA Oe EN LEN Ze GAN S vi SO Ze Sr NA ZIN G in A GES Ges MA SS l i oie ie SASA EE Man ae Ga com Gs MWN a VON SON ae a ERE A Oo VO 2 GIVE KA CE he ty a W MW WA SO MA ne gt e VOY ENEMA AS is Ge Warranty de a i air purchaser at the original ia san only e SRR AN MA AR All logs are guaranteed for three years against manufacturer s defects I JE a di x La ININ f a me TAU son AAAS i fen heat sl 4 1 A ot SO y ae he k re aoe a sea th i a yE A z P AA a ieee Si The burner assembly system is guaranteed for a period of 3 years from the date of purchase and will be replaced for freight cost
6. ghten the attached lockout on the elbow to seal the burner bar to the Figure 6 Burner bar connection wall of the burner pan CONNECTING GAS SUPPLY TO BURNER ASSEMBLY If a Safety Pilot Kit is to be used please refer to separate installation instructions These instructions refer to Natural Gas applications installed without a Safety Pilot Kit LP NG Safety Pilot Kit available at your local store A B Place burner pan assembly in the center of the fireplace Attach brass 3 8 Flared to 1 2 gas valve Part 13 to the 1 2 inch gas supply stub Attach 3 8 flared tubing Part 15 to burner pan assembly Attach opposite end to gas supply line by carefully bending the flared tubing as needed to make the connection Avoid kinking the flared tubing while bending If tubing must be cut use a tube cutter Flare the cut end of the tube with a flaring tool NOTE A good method of bending the tube is to fill it with sand bending the tube as needed to make the connection This method will eliminate kinking in the line Once the tube is in the desired configuration for hookup be sure to empty the tube completely of any sand before tube is connected to the gas supply line and the burner Be certain all connections are tight and use pipe compound on all male threads to seal joints Test all connections with a soapy water solution with the gas supply turned on If bubbles appear on any connection retight and retest Once it is determined there a
7. onoxide Poisoning Carbon Monoxide which is an odorless and colorless gas is a by product of combustion Caution must be taken to insure the fireplace is properly vented when logs are in use To avoid having potentially dangerous fumes enter the living area be sure the chimney is drawing properly and has sufficient draft 5 A fireplace screen must be in place when operating this gas log set This screen shall have an opening s for the introduction of combustion air If the fireplace has glass doors operate this gas set with the doors fully opened 6 The nominal inlet gas pressure for this appliance is 7 water column for natural gas 7 This gas log appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing at pressure in excess of 1 2 PSIG This appliance must also be disconnected from the gas supply system by closing its individual manual shutoff valve during any pressure testing at pressure equal to or less than 1 2 PSIG FIREPLACE PREPARATION PART NO 14 A Professionally clean chimney and fireplace floor of any MM eo combustible material to limit the smell from the system B Open fireplace damper fully and install Damper Stop Clamp with 1 4x2 set screw Part 14 This clamp is designed to allow any pilot combustion by products to vent See figure 2 Should the Damper Stop Clamp supplied not fit a permanent damper stop clamp must be installed that will keep
8. re no leaks whatsoever turn off gas supply and move to next assembly step GRANULE EMBER AND GRATE PLACEMENT A Spread granules Part 16 over the installed burner pan Granules should be sloped to the same angle as the burner pan filling the entire pan See Figure 7A Spread glowing embers Part 17 evenly over the top of the granules covering the entire surface area concentrating on the front and sides of the burner pan for the most realistic burning effect Place log grate Part 7 over the burner pan aligning as shown See Figure 7B Attach back log Standoff Part 18 to the back part of the grate See Figure 7B Figure 7 A amp B Granul and Grate Placement NOTE A hammer may be used to tap the back log standoff in place lt may be necessart to squeeze the back log standoff with pliers after attaching to the grate LOG PLACEMENT Part number 1 through 6 A B C Place longest log in the front of the grate Place the second longest log on the back log standoffs towards the back of the grate Allow approximately 2 inches of separation of the bottom logs to allow for proper flame combustion Arrange remaining logs on top of the two base logs Top logs can be rearranged to achieve the desired flame pattern LIGHTING YOUR GAS LOG SET Manual Valve only A B Open chimney flue damper to the full open position Be sure gas supply is shut off Lay match on top of embers and granules near g
9. s only din Vi ait oa AN A ES va Bes Fe Yi OU 1 W i ei T A a koni Pilot valves and thermocouples are guaranteed for a period of one 1 year under the original manufacturers warranty N A A RESE ate MA Fi Day wi il moll W hin Ss ae GS a SAN ki AN General Warranty This warranty does not apply in the case of improper installation neglect accident An ert oe V S misuse or as a result of modifications of the original product iSong 18833 er eS All costs for removal and re installation are the expressed responsibility of the purchaser Sng ee Se VIE SSN s 2 Er ae Frar OS iy p k3 WA MARS A ki A A A Se si si EEE RAR h BE ai CE G Se AF 3 FO PO OYE PAN OO Body at oke For repair replacement or service to defective part s please contact our Customer Service Hotline number below en Thereafter with valid warranty registration and proof of purchase call the Customer Service Hotline for authorization Si YE to ship defective part prepaid and insured in original carton to Sure Heat Manufacturing EI ei 1861 West Oak Partway Marietta GA 30062 Goods returned improperly packaged are the sole responsibility of S iN purchaser cae Sik W l j T e S Y ai ee t Le be A 4 Sanh ai i 4 fe a i Wa A he e En kwa aan Pid ZE a i Mi It is agreed that any repair or replacement is
10. the exclusive remedy from Sure Heat Manufacturing In no case shall Sure Heat be liable for any consequential damage or breach of this or any other warranty expressed or implied whatsoever This limitation as to consequential damages shall not apply in states where prohibited A Pri Ge Yel NS ON ji YN ME i i Pit VA Ki AYI W A ja LEN e a MON 4 Ki Ii oo oo e B poe Se AA SKK ri i if SARA Ge i Hi Purchased FrOM oo pate Sa Size _ 18 l24 lao Mode n Name Phone Er Y pi kenn Sa Ko re Zoos Stet at PW no sere A ae min Sa Mi W a ee VE ANG Mi ie 3K i pi EI A Es MWA We NESES ARE Eh RAAKAA E Ez Fi AU W AE SEA l ANNE l e Gi 8 t MWN VAN Ki Cals WI a n A i ul Zo A Vi an WA A W VA MN i WI teh ne i Wi l H WO A AR LE YA LA SEL CAU x See h i n x WI Se Se ne Se i DA A mi PNK KORY K REN 4 A LS eta tat erate KK Se SE So A Es e SO Se EE Se Ls AN Jn E Y TRA RIN VES ate W zi re l MW i LI TW i TW n WOW n oN p So En x A OKA R N She PI ee amp ess a e q Please photocopy and return to Sure Heat within 14 days of purchase lf you have other questions please contact the Customer Service Hotline 800 229 5647 R84026 Rev 6 08