Home
Genie 2042-TK Installation Guide
Contents
1. Installer Leave this manual with homeowner Homelink is a registered trademark of Johnson Controls Technology Company Car2U is a registered trademark of Lear Corporation GMI Holdings Inc d b a The Genie Company PN 37026500123 5 15 2009 ALWAYS AT YOUR COMMAND Models 2022 2024 2042 GARAGE DOOR OPENERS Includes 2 Bulb Light System Wall Console Includes INTELLICODE Remote Control Safe l Beam System must be installed to close door For use only with sectional doors Homelink and Car2U compatible For Answers and Assistance 1 800 354 3643 or visit www geniecompany com SAVE THIS MANUAL FOR FUTURE REFERENCE SAFETY INFORMATION OVERVIEW OF POTENTIAL HAZARDS READ THIS SAFETY INFORMATION Garage doors are large heavy objects that move with the help of springs under high tension and electric motors Since moving objects springs under tension and electric motors can cause injuries your safety and the safety of others depend on the owner or user of this system to read understand and implement the information in this manual If you have questions or do NOT understand the information presented contact The Genie Company or an authorized Genie Dealer The safety alert symbol and following signal words DANGER WARNING and CAUTION are used throughout this manual to call attention to and identify different levels of hazard and special instructions This is the safety alert symbo
2. MODELS 2022 2024 2042 LIMITED WARRANTY GMI Holdings Inc d b a The Genie Company Seller warrants to the original purchaser of the below identified opener Model 2022 2024 2042 Product subject to all of the terms and conditions hereof that the Product and all components thereof will be free from defects in materials and workmanship for the following period s of time measured from the date of purchase MOTOR Seller warrants the motor for a period of TEN 10 YEARS PARTS Seller warrants all other parts and components for a period of ONE 1 YEAR Seller s obligation under this warranty is specifically limited to repairing or replacing at its option the Product or any part thereof which is determined by Seller to be defective during the applicable warranty period Any labor charges are excluded and will be the responsibility of the purchaser This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty is made to the original purchaser of the Product only and is not transferable or assignable This warranty applies only to Product installed in a residential or other non commercial application It does not cover any Product installed in commercial or industrial building applications This warranty does not apply to any unauthorized or improper installation alteration or repair of the Product or to any Product or component which has been damaged or deteriorat
3. See section Ri e Check garage door for binding e H an operational problem exists and opener will not run closed The opener can be forced to close as follows See section Fi Hold the wall control button down until door is completely closed e Disconnect the Safe T Beam System from the opener and contact an authorized Genie Dealer or The Genie Company at 1 800 35 GENIE e Check CONTACT REVERSE See section fj e Check garage door for binding e Wires shorted Staples can cut insulation and short wires Repair or replace e Check CLOSE FORCE adjustment See section Bi e Be sure door opener and springs are in good repair properly lubricated and balanced See Maintenance section W e Check OPEN limit setting See section Ri e Check OPEN FORCE adjustment See section Bi e A WARNING If you suspect a problem with the garage door hardware or springs contact an authorized Genie Dealer or a trained door system technician or contact The Genie Company at 1 800 35 GENIE e Check door balance condition and door spring e Check OPEN FORCE adjustment See section Bi e A WARNING If you suspect a problem with the garage door hardware or springs contact an authorized Genie Dealer or a trained door system technician or contact The Genie Company at 1 800 35 GENIE e Was a remote control lost or stolen Erase all remote control codes from receiver memory and reprogram See section Mi e Button stuck on Wall Control or r
4. 2 socket Jon adjustment nut es J Tighten nut to move pulley this direction T Rail at center of rail assembly 1 8 ET CE T Rail FIG 1 7 Belt adjustment Remove Remove FIG 1 8 Disable garage door lock 05 15 2009 1 1 H OPENER INSTALLATION HEADER AND DOOR MOUNTING BRACKETS WARNING Header bracket must be fastened to garage framing Do NOT fasten to drywall particle board plaster or other such materials 1 Finding header bracket mounting location e Close garage door Use a pencil and level a Mark center of garage door one half overall width on the wall with 6 vertical line at top edge of door b Continue this line on wall above door for about 12 Fig 2 1 a Raise garage door until top edge of door reaches its maximum height Fig 2 2 With door at highest point Measure height from top edge of door to floor Fig 2 2 Close door again Mark height measurement on wall above door Fig 2 1 c Make your mark across vertical line made earlier Add 2 1 2 to height mark just made on wall This is location for header bracket Fig 2 1 d WARNING Door springs are under high tension If spring or its shaft is in the way measure 2 1 2 above spring or shaft on the garage door centerline and mark this height as your location for header bracket Do NOT move door spring NOTE If header bracket location needs
5. la electricidad del abrepuertas antes de quitar la cubierta Coupez l alimentation de l ouvre porte avant de retirer le couvercle POWER CORD CORDON DE SECTEUR CABLE ELECTRICO TERMINAL BLOCK SURGE PROTECTOR MOV BORNE LIMITEUR DE SURTENSION BLOQUE DE TERMINALES PROTECTOR DE SOBRETENSIONES We TRANSFORMER BLANCO TRANSFORMATEUR ke TRANSFORMADOR Wa K ar OS PRIMARY SECONDARY PRIMAIRE SECONDAIRE NEGRO PRIMARIO SECUNDARIO 27 RED ROUGE GREEN ROJO VERT VERDE TT YELLOW WHITE MOTOR HALL SENSOR JAUNE BLANC MOTEUR CAPTEUR DE PASSAGE D BIANCO RED MOTOR SENSOR DE PASILLO WHITE BLANC BLANCO d V ORANGE YELLOW AK ANARANJADO ap MR o WARNING ADVERTENCIA AVERTISSEMENT STRIPED WEITE STRIPED WHITE BLANC RAY BLANC RAY ull BLANCO RAYADO BLANCO RAYADO ELECTRICAL SHOCK PHOTO SENSOR WALL CONTROL H E ELECTRI PHOTODETECTEUR COMMANDE MURAL Ger FOTOSENSOR CONTROL DE LA PARED PN 37026500123 05 15 2009 Opener does NOT run from Wall Control Opener runs but door does NOT move Opener works from Wall Control but NOT from remote control Remote control has less than 25 feet operating range or no operation Door starts down then STOPS and goes back up OR Safe T Beam System malfunction Door starts down then STOPS before it is closed OR Door will only open Door starts up but STOPS before it s completely open Door will only run in close direction Door op
6. may be needed to clear a torsion spring NOTE For header bracket pins locate Bag 2 from Box 1 2 Mounting the assembly e Attach rail to header bracket using clevis pin and cotter pin Fig 2 5 e Support power head on step ladder to prevent interference with header mounted torsion spring NOTE Before final attachment to ceiling insure that assembly is in proper alignment Fig 2 4 NOTE For nuts bolts and lag screws locate Bag 3 from Box 1 e On finished ceilings locate ceiling joists or trusses using a stud finder or similar device Attach angle iron not provided to joists or trusses through finish material using provided lag screws Fig 2 6 e On unfinished ceilings or open ceilings straps may attach directly to joists or trusses Depending on the garage construction extra framing material not provided which may be required should be installed using appropriate construction techniques Fig 2 6 NOTE Refer to your local building codes for appropriate construction techniques e Attach mounting straps not provided to ceiling using lag bolts Fig 2 6 e Set height of power head to following Fig 2 6 a Rail must clear door at door s highest point of travel b Rail must be level or at power head end slightly below level e Securely tighten power head mounting bolts and nuts e Carefully raise and lower door manually Ensure door does not contact any section of power head or rail e C
7. reception which may be determined by turning the equipment OFF and ON the user is encouraged to try to correct the interference by one or more of the following measures Re orient or relocate the receiver antenna Increase the separation between the opener and receiver Connect the opener into an outlet on a circuit different from that to which the receiver is connected Consult your local dealer Limit controls location on power head LED Open Indicator Light Open Set Limit a Travel Limit Button PR SET LEARN MANUAL LIMIT FORCE Up Force OPEN Control Adjustment KE Code CODE Button Close Close Travel Limit Set Limit Button CLOSE Down Force Control Adjustment FIG 7 1 Learn code button and LED 05 15 2009 23 MENT AND VISOR CLIP INSTALLATION 1 Battery replacement e To open gently push straight out on battery cover lock tab as shown Fig 8 1 e Slide open battery cover Remove old battery e Make sure new battery is facing proper direction Match battery polarity with symbols inside battery housing Fig 8 2 Recommended replacement battery type Alkaline A23 12 volt FIG 8 1 Open battery cover e Slip new battery into place Slide battery cover until it clicks shut e Operate remote to make sure it is working properly No re programming is needed 2 Visor clip The visor clip may come already installed You will have to install the viso
8. to be above header for garage door opening you need to add a mounting surface A 2 x 6 board securely attached board and fasteners not included to wall studs on either side of your mark is sufficient Fig 2 3 NOTE For header bracket and bolts locate Bag 2 from Box 1 NOTE The bolts supplied in Bag 2 are designed to be used on pressure treated lumber 2 Mounting the header bracket e Hold header bracket against wall Fig 2 3 e Position bracket as shown Place center on vertical line Bottom edge on final height line e Mark screw hole locations on wall e Drill 3 16 pilot holes at each screw hole mark Fasten header bracket with 2 lag screws provided Fig 2 3 1 PN 37026500123 FOR HELP 1 800 354 3643 OR WWW GENIECOMPANY COM b extend vertical line P d final IM height mark Te HN k Jul c door at highest point top of door in closed a 6 vertical position line FIG 2 1 Final height mark HIGHEST POINT OF TRAVEL SECTIONAL DOOR FROM HERE SECTIONAL TO FLOOR DOOR FROM HERE TO FLOOR Sie need L ZZ EE N FIG 2 3 Header bracket mounting on header A above header 05 15 2009 MOUNTING THE OPENER 1 Getting started e Position assembled rail on wall next to header bracket Fig 2 4 Place material on floor under power head to protect from scratching A box stool or similar device
9. 16 18 LAG SCREW 5 16 x 2 SELF DRILLING SCREW 1 4 20 x 3 4 BE DOOR BRACKET E HEX BOLT 5 16 18 x 3 4 a SELF LOCKING NUT 5 16 18 HEEE 4 24 x 1 Pan Head Phillips Screw HEX FLANGE NUT 5 16 18 CLEVIS PIN 5 16 x 3 4 COTTER PIN WALL CONTROL ASSEMBLY PAN HEAD PHILLIPS SCREW 4 24 x 1 13 MM INSULATED STAPLE nn Lag screw 5 16 x 2 E S N SA EN AK p N an N w CA N on on N lt w N Z lt Safe T Beam SOURCE SENSOR BRACKET PHILLIPS HEX SCREW 10 16 x 1 1 4 WIRE NUT GREY REMOTE WITH BATTERY NO BAG Safe T Beam SOURCE SENSOR amp WIRE SET LIGHT COVER WHITE Wire Nut IS Clevis pin long 5 16 x 3 Clevis pin 5 16 x 3 4 ADS Screw 1 4 20 x 3 4 Cotter pin OP Hex Bolt 5 16 18 x 3 4 Hex Bolt 5 16 18 x 1 2 Shoulder Bolt Hex Flange Nut n 114 LE 5 16 18 x 1 MISSING ANY PARTS Please call toll free 1 800 354 3643 DO NOT RETURN TO POINT OF PURCHASE IMPORTANT Information needed when ang e Model number located on are e Store city state ie date of purchase PN 37026500123 05 15 2009 1 PIECE RAIL HARDWARE ASSEMBLED VIEW FOR HELP 1 800 354 3643 OR WWW GENIECOMPANY COM Power Cord Rail with chain Belt Clamp Clevis Pin Long Header amp Cotter Pin Bracket 3 PIECE RAIL HARDWARE ASSEMBLED VIEW Rail with chain Rail Clamps Power He
10. ATE CLOCKWISE Decreasing Force ROTATE COUNTER CLOCKWISE CLOSE Down Force Control Adjustment FIG 6 4 Force Control Adjustment 21 ERASE OPEN CLOSE TRAVEL LIMIT 1 Press and hold both of the SET buttons Sch together until the green indicator light blinks about 5 seconds 2 All close and open travel limit settings are erased Then follow the steps above to reprogram close and open travel limits The force adjustments and limit switch settings MUST BE COMPLETED before testing 1 Testing e Open garage door using Wall Control Place a 2 x 4 board laid flat under center of garage door opening FIG 6 5 e Close door using Wall Control e When door contacts board the door must stop within 2 seconds and reverse direction returning to open position 2 Adjustment e If the door does not properly reverse Check to see if door has close limit programmed It should not have reached its close limit before hitting board If the door STOPS but does not reverse decrease CLOSE FORCE control setting slightly turn it counter clockwise e Test again Repeat as necessary until door reverses upon contacting board 22 PN 37026500123 FIG 6 5 2 x 4 under center of door opening 17 PROGRAMMING REMOTE CONTROLS WARNING A moving door can cause serious injury or death 1 Keep people clear of opening while door is moving 2 Do NOT allow child
11. P 1 800 354 3643 OR WWW GENIECOMPANY COM pa bracket center of E Z bracket L NN TA CAE O Mounting brackets FIG 4 3 Attach sensors to brackets THREE DOOR GARAGE FIG 4 4 Safe T Beam source and sensor locations Source Dashed Line striped wire Solid Line white wire FIG 4 5a Source and sensor wiring methods 05 15 2009 17 3b Wiring pre wired e Route wire from wall to Safe T Beam sensors Fig 4 5b e Splice pre wiring to shortened sensor wire match wire pairs dash to dash striped to Sensor striped and plain to plain white to white Trim sensor wire to approximately one foot 1 ft from sensor Split and strip ends of sensor wires and Ceiling or pre wired wires Fig 4 7 Splice wires together with provided Power Dashed Line striped wire wire nuts Nie nead Solid Line white wire rig 4 5h SSES FIG 4 5b Pre Wired source and sensor wiring e Securely fasten wires where they exit methods wall and ceiling as you go ee Use insulated staples Staples should be snug only Insulated Staple CAUTION Use this Staples which are too tight can cut or pinch wires wire routing Cut or pinched wires can cause the Safe T Beam a J if NOT pre wired System to stop working When using the insulated II Staples make sure you fasten them only as tightly as needed to hold the wire snugly 4 Split and stri
12. PICAL SECTIONAL DOOR INSTALLATION FOR HELP 1 800 354 3643 OR WWW GENIECOMPANY COM OB AE Me TYPICAL SUPPORT BRACKET NOT PROVIDED D Pg 12 13 ADDED HEADER BRACKET MOUNTING BOARD POWER CORD APPROX 45 IN TO 120V GROUNDED OUTLET EXTENSION SPRING OR TORSION SPRING NOTE This opener is designed for use with SECTIONAL doors only SAFE T BEAM SENSORS WARNING To reduce the risk of injury to persons or damage to property Use this opener only with sectional doors PN 37026500123 05 15 2009 RECOMMENDED TOOLS FOR HELP 1 800 354 3643 OR WWW GENIECOMPANY COM a 3 16 Drill Bit Pencil Carpenter s level Kito RP S Ratchet Adjustable wrench Wire strippers J A Tape measure l Safety Glasses Eg H a 1 4 7 16 3 8 and _ Phillips screwdriver 1 2 Sockets Step ladder PARTS IDENTIFICATION Not Shown Full Size IMPORTANT INFORMATION FRRANGING EUX CONTENTE FOR ASEEMELY ORGANISATION DU CONTENU DE LA BO TE POUR LE MONTAGE DISPOSICION DEL CONTENIDO DE LA BOLSA PARA EL MONTAJE A W A R N I N G Remove internal boxes be ir r U Quite las cajas internas Child can be pinned under automatic garage door Death or serious injury can result e Never let child walk or run under moving door e Never let child use door opener controls Always keep moving door in sight e If person is pinned push c
13. above the floor For products having an emergency 2 x 4 board laid flat on the floor release mount the emergency release 6 feet above the floor NOTE Please follow ALL instructions in their NUMBERED sequence Use wall control and safety sensors provided with this unit Do NOT substitute wall control or safety sensors 1 OPENER ASSEMBLY FOR HELP 1 800 354 3643 OR WWW GENIECOMPANY COM RAIL ASSEMBLY Use a clean flat surface NOTE For 1 piece rail skip to POWER HEAD amp RAIL ASSEMBLY WARNING To reduce the risk of injury to persons or damage to property Use this opener only with sectional doors CAUTION Do NOT run until opener is fully assembled and instructed to do so NOTE Three 3 piece rail assemblies are for a 7 foot high sectional door Clear a workspace area to unpack and organize box and contents for assembly 1 There are 4 boxes inside the carton Each box is numbered 1 4 Note that some openers will contain the same parts and be packaged with fewer boxes Carefully remove the three internal boxes Labeled 1 2 and 3 and place them on the floor for easy access Fig 1 1 These boxes contain assembly parts and the contents are organized by assembly tasks For quick reference inside the lid of each box there is a label illustrating the components inside 2 Remove the motor power head and place it on the floor for later use Remove box 4 and place it on the floor for later
14. ad Rail Clamp Bolts Carriage Slide Rail Clamp Nuts Release Knob lii Rail with belt Tensioner Center Rail Clevis Pin Long p E Header amp Cotter Pin Rail Bracket Center Rai PN 37026500123 05 15 2009 IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk of severe injury or death READ AND FOLLOW ALL SAFETY INSTALLATION 5 Do NOT connect the opener to source of power AND OPERATION INSTRUCTIONS If you have until instructed to do so questions or do not understand an instruction call The 6 Locate the Wall Control Genie Company or an authorized Genie Dealer Within sight of door Install only on a properly balanced sectional garage door e At minimum height of 5 feet so small children are not An improperly balanced door could cause severe injury able to reach it and Have a trained door system technician make repairs or e Away from all moving parts of the door adjustments to cables spring assemblies and other Install the Entrapment WARNING Label next to the Wall hardware before installing the opener Control in a prominent location Install the Emergency Remove all ropes and remove or make inoperative all Release Tag on or next to the emergency release locks connected to the garage door before installing opener _ After installing the opener the door must reverse within Where possible install the door opener 7 feet or more 2 seconds when it contacts a 1 1 2 inch high object or a
15. asten straight arm to carriage using clevis pin and cotter pin Fig 2 9 2 Connecting the arms e Slide carriage back and forth to adjust arm length Position the straight arm 50 down from the rail e With the arms arranged in this position fasten arms together using bolts and nuts spaced as far apart as possible Fig 2 9 bolts as far apart as possible FIG 2 9 Attaching door arms 1 4 PN 37026500123 05 15 2009 LL SE Pay S E DAIT DIA me IMQ A INN EL INV IFA L i WARNING Verify there is NO power to the opener before installing Wall Control wires and Wall Control CAUTION Staples which are too tight can cut or pinch wires Cut or pinched wires can cause the Wall Control to stop working When using the insulated staples make sure you fasten them only as tightly as needed to hold the wire snugly Use of any other wall control can cause the door to operate unexpectedly and the light not to work Use only the included Wall Control 1 Wall Control location e Wall Control location should be in direct sight of door e It should be at least five feet 5 above floor to prevent small children from operating door e It must be away from any moving parts You should NOT be able to reach the garage door while standing at Wall Control e Wall Control board screw connections are polarized positive and negative 2a Wiring If pre wired e Locate Wall Control pre
16. e to inform you to eliminate the problem first If you release the open close button on the Wall Control during the closing movement the door will reverse automatically to its fully opened position 05 15 2009 1 9 20 16 Rem WARNING Severe injury or death can result if the door closing force is set too high Never increase the door closing force above the minimum required to move the door Never adjust force to compensate for a sticking or binding door Perform monthly CONTACT REVERSE TEST as described on page 22 and in Section 10 SETTING amp TESTING OPEN CLOSE LIMITS The OPEN UP and CLOSE DOWN door positions are controlled by making the adjustments on the panel located on the bottom of the power head The adjustments that can be made are e Close Travel Limit e Open Travel Limit Adjust Closing Force Adjust Opening Force Transmitter Programming A ENGAGE CHAIN BELT CONNECTOR TO CARRIAGE 1 Press and hold the Close Travel Limit el button until the chain or belt connector advances and engages to the Carriage Assembly Fig 6 2 CAUTION Failure to verify the engagement of the belt chain connector will result in damage to rail components B CLOSE TRAVEL LIMIT 1 Press and hold the Close Travel Limit Si button until the door is fully closed 2 You can quickly press and release the Close Travel Limit Tel button to move the door in small increments You can also use the Ope
17. e a strong mounting location Refer to Section 2 Check to see if the mounting location opener Refer to Section 1 for the Safe T Beam System is clear from obstruction and has a wood surface available for attaching the mounting brackets The brackets may be attached to concrete if necessary but extra tools and special fasteners not supplied will be required Refer to Section 4 and 5 Insure that your door is properly balanced and moving freely Refer to Section 10 NOTE Mounting brackets must be installed within code specifications If your door jams binds is improperly Is your sectional garage door made of balanced or has a broken spring have it aluminum light weight steel fiberglass repaired or adjusted by a trained door system or glass panels Additional support bracing must be added to these type doors If this is the case please contact the door manufacturer or authorized dealer so that they can furnish you with a bracing kit Refer to Section 2 WARNING NOT SHOWN If your garage does not have a separate entry door you should consider To reduce the risk of injury to persons or an emergency release kit GER 2 for installation on damage to property Use this opener only your garage door with sectional doors technician Door springs cables pulleys brackets and associated hardware are under extreme tension and can cause serious injury or death PN 37026500123 05 15 2009 TY
18. e by a trained door kA system technician using proper tools and instructions TENSION PN 37026500123 05 15 2009 et LAVE CC E ERR E EE ENEE ENEE EE VY AW YMG E EE EE EE EE EE EE EE ae E9 f ff goeewee BLESHOOTING GUIDE POWER HEAD LED OMPLIANCE STATEMENT Deg Peer TT ee 30 Mk Opener MUST be installed with the included Wall Control Safe T Beam Safety Reverse System MUST be installed to close door mu a INTELLICODE Rolling Code Security System An electronic rolling code system that enhances the security of the door opener by continuously changing the access code each time the remote control is used The door opener responds to each new code ou once An access code copied from a working system and tried again will not control the door opener Lighted Wall Control Operates door opener from inside garage Refer to section 3 A HomeLink COMPATIBLE www homelink com and Car2U compatible Follow the Homelink or Car2U instructions in your car owners manual Safe T Beam Non Contact Reversing System Puts an invisible beam across the door opening The door stops and reverses to the full open position if anything passes through the beam Red or green LED indicator lights on the power head provide a self diagnostic code if an operational problem exits Refer to Section 10 Safe T Reverse Co
19. ed due to misuse neglect accident failure to provide necessary maintenance normal wear and tear or acts of God or any other cause beyond the reasonable control of Seller and does not cover batteries missing or damaged parts from clearance or open box sales or repairs or maintenance to door components ALL EXPRESS AND IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN TIME TO THE APPLICABLE WARRANTY PERIOD REFLECTED ABOVE NO WARRANTIES WHETHER EXPRESS OR IMPLIED WILL APPLY AFTER THE LIMITED WARRANTY PERIOD HAS EXPIRED Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you IN NO EVENT SHALL GMI HOLDINGS INC OR ITS PARENT OR AFFILIATES BE RESPONSIBLE FOR OR LIABLE TO ANYONE FOR SPECIAL INDIRECT COLLATERAL PUNITIVE INCIDENTAL OR CONSEQUENTIAL DAMAGES even if Seller has been advised of the possibility of such damages Such excluded damages include but are not limited to loss of use cost of any substitute product or other similar indirect financial loss Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Claims under this warranty must be made promptly after discovery and within the applicable warranty period To obtain warranty service you must contact Genie cus
20. emote e Check CLOSE limit switch setting See section Ri e Wires shorted Staples can cut insulation and short wires Repair or replace e Be sure all fasteners are tight e Be sure door and opener are in good repair properly lubricated and balanced See Maintenance section W PN 37026500123 05 15 2009 2 7 ING GUIDE POWER HEAD LED FOR HELP 1 800 354 3643 OR WWW GENIECOMPANY COM Power head LED Red LED Green LED Possible Problem showing showing Continuous ON e Programming incomplete e Complete programming 1 BLINK Pause e Transmitter has not learned e Push transmitter button to program Repeat See section Mi 1 BLINK Pause e Limit Programming incomplete Set DOWN LIMIT programming Repeat e Safe T Beam sensor e Check for obstruction remove obstruction going down Door obstruction going down e Check for obstruction remove Door obstruction going up Check door spring See section ff Contact The Genie Company at 1 800 35 GENIE 2 BLINKS Pause Limit Programming incomplete set UP LIMIT programming Repeat Wire to power head or wire Check power head wiring check connection at power head is connections bad Replace or repair Sensors out of alignment Check Source amp Sensor alignment Continuous obstruction of Check for obstruction of Safe T Beam sensor Safe T Beam sensor 3 BLINKS Pause je Limits set backwards e Clear limits and reprogram Repeat See section H 4 BLINKS Pause ie Wall bu
21. ener starts for no reason Noisy operation PROBLEM WHAT TO DO FOR HELP 1 800 354 3643 OR WWW GENIECOMPANY COM e Check power source Plug a lamp into outlet used for power head If lamp works power source is OK If not check fuse or circuit breaker e H power is OK Check connections at power head terminals and at Wall Control e Check for reversed broken or cut wires Staples can cut insulation and short wires Repair or replace e Make sure carriage is engaged to carriage slide Place carriage lever in lock position e Check to make sure chain belt is not broken or OFF its track e Check FORCE ADJUSTMENT See section Bi Door opener will NOT run more than 30 seconds each way if door does not move e Confirm vacation lock switch on wall control is OFF See section Ri e Program remote control code into receiver memory See section KA e Replace remote control battery See section Bi e Relocate remote control inside car and or point remote control at garage door e Replace battery See section Bi e Reposition door opener antenna e Red LED blinks while button is being pushed or LED does not come ON battery is low replace battery e lf a NEW installation check Door Arm position See section B e Check if Safe T Beam Red LED is flashing e Check Safe T Beam system for beam obstruction or misalignment of lenses Realign or replace Sensors See section El e Check CLOSE FORCE adjustment
22. erse on contact with a 1 1 2 high object or a 2 x 4 board laid flat at the center of the doorway on the floor After adjusting either the force or the limit of travel retest the door opener Failure to adjust the opener properly may cause severe injury or death When possible use the emergency release only when the door is closed Use caution when using this release with the door open Weak or broken springs are capable of increasing the rate of door closure and increasing the risk of severe injury or death KEEP DOORS PROPERLY BALANCED See your garage door Owner s Manual An improperly balanced door increases the risk of severe injury or death Have a trained door system technician make repairs to cables spring assemblies and other hardware SAVE THESE INSTRUCTIONS lf you have any questions please do not hesitate to contact Genie customer service at 2 Contact reverse e Place a 2 x 4 board laid flat on floor In center of garage door opening e Close door by using wall control or remote control Door fails to reverse on contact with board See section RH CONTACT REVERSE Opener still fails CONTACT THE GENIE COMPANY OR AN AUTHORIZED GENIE DEALER WARNING e Garage door hardware springs cables brackets pulleys etc are under extreme pressure and tension e DO NOT attempt to repair or adjust door springs or any hardware and DO NOT OPERATE garage door automatically or manually if door
23. head Route Wall Control wires through wire guide on power head Split and strip ends of wire Fig 3 2 on previous page Insert wire into terminal holes and lightly press in the orange locking clips above each terminal hole You can use a pencil or small screwdriver to comfortably press in locking clips The white wire into 1 terminal hole and striped wire into infin JI Jitz P B Infared Sensor the 2 terminal hole Power Head With Rear Cover Removed Confirm wire lock by lightly tugging on the wire The wire should remain in the terminal hole FIG 3 3 Insert wires e Do NOT install rear cover yet 4 Mounting e Fasten Wall Control to wall with 2 screws provided Fig 3 4 e Remove protective backing from Entrapment warning label Fig 3 5 The Entrapment label is located in the center of this manual Stick label on wall near Wall Control Vacation Locking Switch LOCK disables controls after door is completely closed UNLOCK allows controls to work normally Door Control Open Close Button Open and closes door from inside garage Independent Light Control Controls door opener lights from inside garage Energy Saver shut off turns OFF lights 3 minutes after door activation FIG 3 5 Mounting Entrapment warning label PN 37026500123 05 15 2009 AFE T BEAM SYSTEM INSTALLATION WARNING There should be no electrical power to the
24. heck that rail clamp bolts and nuts are tight e DO NOT PLUG OPENER IN YET PN 37026500123 HEADER BRACKET FROM ABOVE f not to scale COTTER PIN Chain drive shown FIG 2 5 Rail mounting to header bracket ANGLE IRON ON FINISHED CEILING DRYWALL Extra framing not needed bolts amp nuts Extra framing FIG 2 6 Mounting the power head 05 15 2009 13 Doors made of masonite lightweight wood fiberglass and sheet metal must be properly braced before mounting door opener Contact door manufacturer or distributor for a bracing kit The Genie Company is not responsible for damage caused due to improperly braced door centerline even with or above top roller 1 Finding door bracket mounting location e Door bracket is mounted as high on door as possible along vertical centerline and NO LOWER THAN top set of rollers Fig 2 7 2 Mounting the door bracket e Proper bracing should be verified at this point Align door bracket centered on your vertical centerline Fig 2 8 Attach using 3 self drilling screws for sheet metal or other light weight material Use lag screws not provided for solid wooden sectional doors FIG 2 8 Examples of door bracket positioning TALL DOOR ARMS 1 Attach the arms e Fasten short branch of curved door arm to door short clevis pin amp cotter pin bracket using bolt and locking nut Fig 2 9 e F
25. is improperly balanced or springs are broken CONTACT A TRAINED DOOR SYSTEM 3 Safe T Beam System TECHNICIAN Red LED blinks ROUTINE MONTHLY MAINTENANCE check alignment See section Ei 1 Door balance e With the door closed pull emergency release knob Carriage Lock towards the opener to release door from carriage assembly e Raise door manually approximately 3 A and release Door should remain stationary or move very slightly H door moves quickly CONTACT A TRAINED DOOR SYSTEM TECHNICIAN e Close the door e Pull emergency release knob towards door to engage carriage Operate door using remote D WARNING Door will re attach itself to carriage assembly Use Wall Control supplied with opener Any other Wall Control can cause the opener to operate unexpectedly PN 37026500123 05 15 2009 25 CIRCUIT WIRING DIAGRAM FOR HELP 1 800 354 3643 OR WWW GENIECOMPANY COM Opener circuit wiring diagram This wiring diagram is for reference only Diagrama del circuito del abrelatas Este diagrama es solo para referencia Schema de c blage de l ouvreur Ce sch ma de c blage est indiqu a titre de r f rence uniquement Opening Cover May Cause Electric Shock Abrir la tapa puede causar choques el ctricos WARNING L ouverture du couvercle peut entra ner des chocs lectriques ADVERTENCIA Disconnect power from opener prior to removing cover AVERTISSEMENT Desconecte
26. l This symbol is placed next to signal words and messages to help you identify important safety information The word A DANGER indicates an imminently hazardous situation which if NOT avoided will result in death or serious injury A WARNING indicates a potentially hazardous situation which if NOT avoided could result in death or serious injury A CAUTION indicates a potentially hazardous situation which if NOT avoided may result in injury or property damage The word NOTE is used to indicate important steps to be followed important considerations or location of parts IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS ping EFFECT PREVENTION Keep people clear of opening while door is moving A WARNING FER FR Could result in Death or Serious Injury Do NOT allow children to play with the door operator Do NOT operate a door that jams or one that has a broken spring MOVING DOOR Turn OFF power before removing operator cover WARNING When replacing cover make sure wires are not pinched or near Wee Could result in Death HOMO alt or Serious Inju ELECTRICAL jury Operator must be properly grounded SHOCK A WARNING Do NOT try to remove install repair or adjust springs or anything to which door spring parts are fastened such as wood blocks steel Could result in Death brackets cables or other like items or Serious Injury Installations repairs and adjustments must be don
27. ment To Garage Door e FIG 6 1 Limit controls Latch Movement FIG 6 2 Engage Chain Belt Connector to Carriage CAUTION Operation of the opener without the Chain or Belt Connector engaged to the Carriage Assembly will result in damage to rail components including the rail pulley 05 15 2009 The Carriage Lock can be manually engaged or disengaged e To disengage Carriage Lock Pull handle downward opener power head e To engage Carriage Lock Pull handle towards door 1 By turning the Close Force Control clock wise the DOWN force can be increased By turning the Close Force Control D counter clockwise the DOWN force can be decreased Set the DOWN force level at the minimum force required to close door without reversing 2 Once the desired level is selected this stores the necessary force level for the DOWN direction in memory 3 By turning the Open Force Control clockwise the UP force can be increased By turning the Open Force Control counter clockwise the UP force can be decreased Set the UP force level at the minimum force required to open door without stopping 4 Once the desired level is selected this stores the necessary force level for the UP direction in memory UNLOCK TO RELEASE TO RECONNECT PULL TOWARD PULL TOWARD THE OPENER DOOR FIG 6 3 Engage Disengage Carriage Lock Up Force OPEN Control Adjustment Increasing Force ROT
28. n Door will stop e Press button again Door will move in opposite direction NOTE The door will stop automatically at the fully open or fully closed position LOST OR STOLEN REMOTE 1 Clear memory e Press and hold Learn Code button on power head for 10 seconds or until the red blinking indicator LED goes out e Program remaining or new remote controls as done previously Your door opener will no longer recognize any signal received from the missing remote control or any other which has not been reprogrammed PN 37026500123 A HomeLink COMPATIBLE www homelink com NOTE To program a Homelink and Car2U device follow the Homelink or Car2U instructions in your car owners manual FCC and IC CERTIFIED This device complies with FCC Part 15 and RSS 210 of Industry Canada This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television
29. n Travel Limit 2 button to move the door slightly in the UP direction 3 Door is fully closed when the bottom edge of door presses firmly onto the ground 4 Once the door is in the desired position press and release the Close SET Limit button The LED indicator light will blink green once This stores the closed position in memory C OPEN TRAVEL LIMIT 1 Press and hold the Open Travel Limit le button to move the door to its fully opened position This starts the opener moving in the UP direction 2 Hold the Open Travel Limit el button until the door is in the fully opened position that you desire then release this button 3 You can quickly press and release the Open Travel Limit Tel button to move the door in small increments You can also use the Close Travel Limit el button to move the door slightly in the DOWN direction 4 Once the door is in the desired position press and release the Open SET Limit EI button The LED indicator light will blink green twice This stores the opened position in memory PN 37026500123 FOR HELP 1 800 354 3643 OR WWW GENIECOMPANY COM Limit Controls location on power head LED Open Indicator Light Open Set Limit KA Travel Limit Button Up Force OPEN Control Adjustment BER LEARN MANUAL LIMIT FORCE JE w Learn Code CODE Close Close CLOSE Down Force Button Travel Limit Set Limit Control Button Adjust
30. not required to have your garage door opener permanently wired with circuit breaker protection If building codes require door opener to be permanently wired have a qualified licensed electrician connect power with permanent wiring WITH GROUNDED PLUG Plug the opener into a properly grounded electrical outlet Fig 5 1 WITH PERMANENT WIRING Instructions for Electrician e Remove power from circuit e Remove rear cover and motor cover Remove four motor cover screws Fig 5 2 Remove existing power cord and strain relief from the 7 8 dia hole and discard Fig 5 3 Connect permanent wiring to power head using 7 8 diameter hole White to white black to black ground to green Use only UL recognized wire nuts Wires inside the power head must be at least 6 in length Replace motor cover and rear cover and re energize the circuit NOTE The Genie Company is not responsible for charges resulting from work performed by an independent electrician WITH POWER SUPPLIED Check Safe T Beam alignment Fig 5 4 e Insure that no part of door or its hardware is in path between lenses of source and sensor e Insure that tops of lenses are between 5 6 above the floor Fig 5 4 The brackets are flexible and can be adjusted slightly if needed e Adjust the Red LED transmitter by aiming the unit directly at the Green LED receiver Use the adjustment screw located on the top of the transmitter ho
31. ntact Reversing System Automatically stops and reverses a closing door within 2 seconds of contact with an object Refer to Section 6 Safe T Stop Timed Reversed System Automatically opens a closing door if it fails to close completely within 30 seconds ForceGuard Control Features adjustable open and close force settings For maximum safety these must be set to the minimum force required to fully open and close the door Refer to Section 6 Relay Monitoring System Automatically stops and reverses a closing door if the closing relay malfunctions Watch Dog Monitoring System Automatically stops and reverses a closing door if the Safe T Beam System notes an operational problem Automatic Lighting System Twin bulb lighting supplies up to 120 watts of light for safer evening exits and entries Turns ON when door is activated and automatically turns OFF 3 minutes later Manual Emergency Release Manually releases door from door opener Use during a power failure or other emergency to allow manual opening and closing of door Refer to Section 6 PN 37026500123 05 15 2009 PRE INS TALLA TION CHECK LIS T FOR HELP 1 800 354 3643 OR WWW GENIECOMPANY COM Things to consider if you are planning to Do it yourself This opener is designed for use with SECTIONAL doors only In many cases you will be replacing an existing door opener with a new one however if this will be the first opener installed there are
32. ontrol button or use emergency release e Test door opener monthly fer to your r s manual ct or 2x4 laid flat on floor oor fails to reverse on contact adjust opener opener still fails to reverse door repair or replace opener Follow instructions in the Installation Manu Proc der selon les instructions stipul es dans le manuel d Box Contents Sheet SSES Three button SE Remote Control Safe T Beam Source Safe T Beam Sensor with wire with wire Red LED Green LED Insulated Staple Safe T Beam Source Sensor Bracket End Rail Section Center Rail Section OO Oo Oo 0 0 Wall Control Door Arm Gi O 0010000 DI oy N T A IL e ege d nl OOOO COOCOO 00 0 ofa oo 00 OF Ito ong opge ol OR Head Rail Chain Section O O ae O O co fe LAN Le Head Rail Belt Section Pro Rail Belt Section kb PN 37026500123 05 15 2009 FASTENERS Shown Full size See Parts List below for full description BAG NO DESCRIPTION RAIL SECTION CLAMP RAIL CLAMP BOLT 5 16 18 x 5 8 HEX FLANGE NUT 5 16 18 SE Rail Clamp Bolt 5 16 18 x 5 8 CLEVIS PIN LONG 5 16 x 3 COTTER PIN HEADER BRACKET EE 10 16 x 1 1 4 Phillips Hex Screw See H LAG SCREW 5 16 x 2 HEX BOLT 5 16 18 x 3 4 HEX FLANGE NUT 5
33. oor Belt and rail should extend approximately 7 feet 5 Align the three rail sections by pulling the belt straight and wrapping it around the tensioner pulley Fig 1 3 amp 1 4 6 Attach the two rail clamps to the rail section joints with 4 bolts and nuts After both rail clamps have been assembled to the rail sections securely tighten the bolts and nuts PN 37026500123 CHAIN DRIVE RAILS CHAIN Rail Clamps Release L4 Knob zon Rail Clamp Nuts Center Rail 05 15 2009 Center Rail Be Lin E a POWER HEAD A RAIL ASSEMBLY Assembly for CHAIN DRIVE OPENER NOTE Handle carefully Drive chain can slide out of rail NOTE For power head and rail assembly locate Bag 1 from Box 1 NOTE Copy serial number from power head frame and record it on warranty page 1 Attach rail assembly to power head by aligning the sprocket onto the motor shaft Use 3 bolts 5 16 18 x 1 2 Fig 1 5 2 Tighten the chain by turning the adjustment nut clockwise The chain adjustment nut is located in the Chain Pulley Bracket opposite rail end from the power head Fig 1 6 3 Tighten chain until chain is approximately 1 8 inch above the base of the rail at midpoint on the rail Fig 1 6 Do NOT over tighten chain CAUTION You should have removed all ropes and or cables NOT door lift cables and disabled the door lock already If you have not remove all rope
34. opener while installing Safe T Beam wires If you have plugged in the power cord UNPLUG IT NOW 1 Mounting brackets e Mark both sides of garage door frame or wall no higher than 6 and no lower than 5 above floor Fig 4 1 e Hold bracket against door frame or wall Check if brackets extend out from wall far enough so tongue of bracket is beyond door tracks or any door hardware If not a Mounting bracket extensions are available through an authorized Genie Dealer b Blocks of wood etc may be substituted for extensions e Center bracket on your mark Fig 4 2 e Fasten each with 2 screws Fig 4 2 2 Mounting Safe T Beam Source Red LED and Sensor Green LED e If garage has only one garage door Determine which side of garage receives most direct sunlight Fig 4 4 Red LED should always be on sunny side whenever possible Fig 4 4 e For multiple doors Preventing crossed signals is critical Place source and sensor modules on adjacent doors facing in opposite directions Fig 4 4 e Slide source sensor onto tongue of bracket until it clicks into place Fig 4 3 3a Wiring If NOT pre wired e Route wire from Safe T Beam sensors to power head using method shown in Fig 4 5a e Securely fasten wires to wall and ceiling as you go Fig 4 6 on next page Use insulated staples Staples should be snug only WEE Staple PN 37026500123 FOR HEL
35. p ends of sensor wires Fig 4 7 lt Invisible Light Beam Protection Area 5 Attach Safe T Beam wire to power head wire terminal e Route Safe T Beam wires through wire guide on power head Insert wire into terminal holes and lightly press in the orange locking clips above each terminal hole You can use a pencil or small screwdriver to comfortably reach in and lightly press down locking clips Insert white wires to even numbered terminal holes and striped wires into odd terminal holes Fig 4 8 ars E Terminal fren OLOLOLOL L 6154131211 Confirm wire lock by lightly tugging on the wire The wire should remain in the terminal hole FIG 4 8 e Do not install the white lamp cover at this time Insert wires Power Head With Rear Cover Removed PN 37026500123 05 15 2009 15 CONNECTING TO POWER WARNING e To reduce the risk of electrical shock this equipment has a grounded type plug that includes a third grounding pin This plug will only fit a grounded type outlet If you do not have a grounded outlet contact a qualified licensed electrician to install one DO NOT alter the plug in any way The door opener must be properly grounded in order to prevent personal injury and damage to the components e DO NOT remove motor cover All work performed on motor must be done by a trained door system technician CAUTION e Check local building codes to make sure that you are
36. r clip if you choose to attach your remote to the car visor e Slide visor clip into back of remote control It will snap into place Fig 8 3 FIG 8 2 Match battery polarity FIG 8 3 Attach visor clip For added safety and Ree please unplug opener before installing light bulb 1 Light bulb e Recommendations Do NOT use a short neck bulb Light bulbs should be no more than 60 Watts Use a heavy duty service bulb for longer life e Screw 1 bulb into each socket 2 Lens e Select a white lamp cover e On the power head end nearest the garage door line up lamp lens tabs on power head with corresponding slots in lens Fig 9 1 e Slide lens onto power head Make sure the tabs FIG 9 1 Slide each lens onto motor cover are fully engaged into lens slots Fig 9 2 e Repeat for rear lens on power head e Plug power cord back into electrical outlet e Test lamp operation FIG 9 2 Fasten lens 24 PN 37026500123 05 15 2009 IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of severe injury or death 1 READ AND FOLLOW ALL INSTRUCTIONS Never let children operate or play with the door controls Keep the remote control away from children Always keep the moving door in sight and away from people and objects until the door is completely closed NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR NEVER GO UNDER A STOPPED PARTIALLY OPEN DOOR Test opener monthly The door MUST rev
37. r los mismos Les metteurs sont conformes la r glementation am ricaine et canadienne compter de leur date de fabrication Aucune garantie n est stipul e indiquant qu ils sont conformes toutes les prescriptions juridiques d autres autorit s Si les metteurs sont utilis s dans d autres pays il incombe l importateur den d terminer leur conformit aux lois et r gles locales pouvant diff rer de celles des tats Unis et du Canada avant toute utilisation desdits metteurs Sendegerate entsprechen allen gesetzlichen Bestimmungen in den USA und Kanada zum Zeitpunkt der Herstellung Wir ubernehmen keine Gewahrleistung fur die Einhaltung aller gesetzlichen Bestimmungen in anderen Landern Sollen Sendegerate in anderen Landern eingesetzt werden so muss der Importeur vor dem Gebrauch sicherstellen dass die Sendegerate auch solchen lokalen Bestimmungen entsprechen welche von den Bestimmungen der USA und Kanadas abweichen AE TRE D ORES DI E A DEN A AEE Ke MERROREE RE ti KPA AER ZI tee UR a Re GEREEST HOMME ZR ERER ENEE LMA PI BIAS ooh EE CELL Ed LALARO Ee EE FICHES 2 PAUL RATE RHA KAILA VI M FEN OE CHE S41 E DETTAL Di FEN DISA CHE OE CRS Z ENS 270 Hh ERICH 2 ZE edel E ETA MADE Se Olea UC MSO HZ SAS YF ek 2 TARA eot SIUC 7IEF CE HSH DE HAQI Gd AFS Heto ARE Gell ua SHADES 7E CRE AAAA AT SS ROBE ARS ol Ol SAM Droa LCR 2H CS BE AAAS Hat EA HeFe RE BAolOk ELLE PN 37026500123 05 15 2009 29 GENIE
38. ren to play with opener including Wall Control remote control or Wireless Keypad 3 During programming the door opener could begin to run so keep people and objects away from the moving door and its parts To keep the door from moving close the door and disconnect it from the Opener by pulling the Emergency Release NOTE For remote control locate Box 3 1a Single Button Remote Programming NOTE This opener can learn up to 7 transmitter buttons e Locate Learn Code button and indicator LED on the power head Fig 7 1 e Press and release Learn Code button Indicator LED will blink RED at a rate of twice per second e Within 30 seconds push remote control button once Indicator LED will stop blinking and stay ON e Press remote control button again Red LED will go out Remote is now programmed and ready for use 1b Multi Button Remote Programming NOTE Each button on a multi button remote is designed for use with 1 door You cannot program 2 buttons to operate the same door nor can you program 1 button to operate 2 doors You can program a maximum of 7 different transmitters or wireless devices NOTE Pushing two buttons on power head simultaneously will erase programmed memory and limits must be reset e For each button Program each button separately using the Single Button Remote Programming steps 2 Operating e Press remote button once Door will move e Press button agai
39. s and or cables and disable garage door lock NOW before continuing with installation Fig 1 8 Set assembled power head and rail aside Begin with Section 2 INSTALLATION Assembly for BELT DRIVE OPENER NOTE For power head and rail assembly locate Bag 1 from Box 1 NOTE Copy serial number from power head frame and record it on warranty page 1 Attach rail assembly to power head by aligning the sprocket onto the motor shaft Use 3 bolts 5 16 18 x 1 2 Fig 1 5 2 Tighten the belt by turning the adjustment nut clockwise The belt adjustment nut is located in the Belt Pulley Bracket opposite rail end from the power head Fig 1 7 3 Tighten belt until belt is approximately 1 8 inch above the base of the rail at midpoint on the rail Fig 1 7 Do NOT over tighten belt CAUTION You should have removed all ropes and or cables NOT door lift cables and disabled the door lock already If you have not remove all ropes and or cables and disable garage door lock NOW before continuing with installation Fig 1 8 Set assembled power head and rail aside Begin with Section 2 INSTALLATION PN 37026500123 Use 5 16 18 x 1 2 H Use 1 2 socket DN on adjustment nut Tighten nut to move pulley this direction E T Rail at center of rail assembly 1 8 IE 4 FIG 1 6 Chain adjustment Belt Pulley Bracket at wall end of rail ken h a
40. some pre installation issues which need to be addressed They are as follows The Genie Company recommends that you read and fully understand all information and instructions contained herein before choosing a Do it yourself installation Any questions should be directed to The Genie Company or an authorized Genie Dealer The issue numbers below refer to the circled numbers in the illustrations on page 5 Check your ceiling where the power You need a properly grounded 110 120 Volt head of your new unit will be mounted power supply available The outlet should be Plan how you will be mounting the power head no more than 3 feet from the power head once it is It is possible that ceiling joists may not be in the mounted Refer to Section 5 position needed with respect to the garage door opener It may be necessary to add an WARNING DO NOT USE AN EXTENSION CORD DO NOT USE A PORTABLE GENERATOR This additional bracket and fasteners not included with your new door opener kit Refer to Section 2 product is designed to operate on standard house current Check the wall directly above the garage DO NOT USE ALTERNATE POWER SUPPLIES door The door opener s header bracket must be securely fastened to this wall Insure 6 To avoid damage to your door and or opener make sure you disable and or remove any door locks ropes and or cables 8 NOT door lift cables prior to installing your that the structure will provid
41. tomer service and provide proof of the date and location of purchase and identification as the original purchaser Call Genie Customer Service toll free at 1 800 354 3643 to speak with a trained representative Purchaser must allow seller a reasonable opportunity to inspect Product claimed to be defective prior to removal or alteration of its condition Upon determination by Seller that the Product or any part thereof is defective during the applicable warranty period which may require purchaser to return the Product to Seller at purchaser s expense Seller will supply the purchaser with replacement parts or at its option a replacement Product Seller may use new or reconditioned parts or a new or reconditioned Product of the same or similar design a There are no established informal dispute resolution procedures of the type described in the Magnuson Moss Warranty Act PURCHASER INSTALLATION ADDRESS DATE PURCHASED SERIAL NUMBER OPENER MODEL REMOTE CONTROL MODEL DEALER NAME DEALER ADDRESS P900 787
42. tton wire short e Check button s and wiring Repeat Staples can cut insulation and shorts wires Replace Wall Control repair or replace wiring Contact The Genie Company at 1 800 35 GENIE e Wall button wires reversed e Reverse wire placement in power in power head connector head connector See section KI 5 BLINKS Pause Te Chain belt is too tight e Adjust chain belt tension Repeat See section El Contact The Genie Company at 1 800 35 GENIE e Control system failure e Contact Gene authorized dealer for service PN 37026500123 05 15 2009 TRANSMITTER COMPLIANCE STATEMENT Transmitters comply with all United States and Canadian legal requirements as of the date of manufacture No warranty is made that they comply with all legal requirements of any other jurisdiction If transmitters are to be used in another country the importer must determine compliance with any local laws and regulations which may differ from United States and Canadian requirements prior to use Los transmisores cumplen con todas las reglamentaciones legales de los Estados Unidos y del Canada en la fecha de fabricaci n Ninguna garant a se da que cumplan con todas las reglamentaciones legales de ninguna otra jurisdicci n Si los transmisores se van a utilizar en otro pais el importador debe determinar si cumplen con las reglamentaciones y leyes locales que puedan ser diferentes a las reglamentaciones de los Estados Unidos y del Canada antes de usa
43. use Box Label Example FIG 1 1 Internal boxes PN 37026500123 05 15 2009 9 10 Rail Assembly for CHAIN DRIVE OPENER NOTE For split rail clamps nuts and bolts locate Bag 0 from Box 1 3 Remove the two rail sections that are not connected to the chain and place them on floor Fig 1 2 A 4 Carefully remove the third rail section with chain and plastic sleeve Place rail section on floor and extend chain straight out Fig 1 2 B Chain and rail should extend approximately 7 feet 5 Remove wire ties and plastic bag from chain Leave chain extended straight out on floor Avoid kinks in the chain by careful handling and keeping chain flat on the floor 6 Align the three rail sections by pulling the chain straight and wrapping it around the chain tensioner pulley Fig 1 3 amp 1 4 7 Attach the two rail clamps to the rail section joints with 4 bolts and nuts After both rail clamps have been assembled to the rail sections securely tighten the bolts and nuts Rail Assembly for BELT DRIVE OPENER NOTE For split rail clamps nuts and bolts locate Bag 0 from Box 1 3 Remove the two rail sections that are not connected to the belt and place them on floor Fig 1 2 A 4 Carefully remove the third rail section with belt Place rail section on floor remove ties on belt and extend belt straight out Fig 1 2 B Avoid twists and kinks in the belt by careful handling and keeping belt flat on the fl
44. using to make adjustments e The Red LED transmitter will blink if there is a misalignment When the LED units are aligned the Red LED will remain ON continuously e After the alignment is finished tighten the adjustment screws on both sensors PN 37026500123 FOR HELP 1 800 354 3643 OR WWW GENIECOMPANY COM FIG 5 2 Remove motor cover Electrican ONLY FIG 5 3 Power cord strain relief CAUTION Do NOT use an extension cord Do NOT use a portable generator This product is designed to operate using standard household current Do NOT use alternate power supplies FIG 5 4 Check Safe T Beam alignment INFRARED PROTECTION FUNCTION When the garage door is opening its movement will not be influenced if the Safe T Beam is obstructed If the Safe T Beam is obstructed before the garage door fully closes the door will not close When the garage door is closing if Safe T Beam is cut off by people or obstacle the garage door will reverse automatically to its fully opened position Meanwhile the opener light will keep blinking until door moves to its fully opened position If the Safe T Beam System fails loses power or is installed improperly press and hold the Wall Control open close button until the door reaches its fully closed position The LED indicator light on the power head will be green and blink twice Pattern X8 pause 1171 paus
45. wired wire ends Fig 3 1 They should be located within the guidelines mentioned above e Split and strip ends of wire Fig 3 2 e Fasten wire to Wall Control board screws on back of Wall Control Striped wire to the plus terminal White wire to the minus terminal 2b Wiring If NOT pre wired e Pick a convenient location for mounting Wall Control using the guidelines mentioned above Fig 3 1 e Run wire from power head to Wall Control Fig 3 1 e Split and strip ends of wire Fig 3 2 e Fasten wire to Wall Control board screws on back of Wall Control Striped wire to the plus terminal White wire to the minus terminal PN 37026500123 Wire from power head to Wall Control Wall Control SS warning label Separate entry door EXAMPLE ONLY This is an example of wire routing when NOT pre wired Your wire routing may be different FIG 3 1 Wall Control wire routing FIG 3 2 Splitting and stripping 05 15 2009 15 3 Securely fasten wires Locking e Securely fasten wires to ceiling and 7 m ni puis wire guide mt wall using insulated staples provided SIS10101e Use insulated staples 6 A 5 Staples should be snug only Insulated e f rear cover is attached to power head Staple remove it e On power