Home

Genie 2022-T Instructions / Assembly

image

Contents

1. 4 7 1 4 x 1 1 4 lag screws provided into wood If ric mounting into concrete or block other fasteners are 6 oo required and are available at leading retail stores no L Use garage pre wiring when available or route two we 9 lengths of two conductor wires from powerhead i SA through 4 wire clips and fixed to top of rail across Floor mount option lt gt header on both left and right of door down to the source and sensor Secure wire to rail with wire clips spaced evenly along rail and wire to header and wall with insulated staples Insert wires from above Powerhead through control wire tube Cut off excess wire Attach wire to terminals on each Safe T Beam At powerhead twist 2 y striped wires together and insert into lt Sensor terminal 1 then twist 2 white wires ource together and insert into terminal 2 Tape excess wire to powerhead away from lights At powerhead press IN the orange tabs above the terminal to insert the wires with a flat head screw driver To powerhead i Sensor Source A CAUTION When using insulated staples make only snug enough to hold wire in place Staples too tight can cause damage to wire and cause Safe T Beam System to malfunction 2 Fully read instructions and warnings before proceeding 1e Lift door end rail section C slightly and slide rail connector J onto middle rail section B 1f Lower door rail end section C and s
2. Swing lens E up into place It may be necessary to squeeze lens slightly to align tabs with slots at top of motor cover Parts List Chain drive models A Opener end rail section G Powerhead bracket L Safe T Beam wall B Middle rail section H Mounting straps console wire C Door end rail section I Powerhead bracket M Remote D Door arm curved belt drive N Wall console E Powerhead lens J Rail connector 0 Wireless keypad F Powerhead K Emergency release cord Optional on some models Mounting Rail Bracket on Header ia ORANGE BAG hardware 4a Center header bracket above door mark holes 4b Drill two 5 32 pilot holes in header board or 2 x 6 board connected to wall studs 4c Secure bracket with lag screws Typical Installation Highest Point of Door Travel 5 16 x 1 3 4 Lag screw Highest Point Of Travel Door centerline t Sectional Door Highest point of door travel as door is opening plus To determine highest point of door travel Get on a ladder to the side of your garage door Have someone lift the door open slowly As the door is raised note the point and amount it extends above the door tracks with tape measure that is the highest point of door travel Measured from floor to door or from door to ceiling Highest point of door travel plus Sectional door Highest point plus 2 5 One piece door Highest point plus 6 A
3. WARNING Door springs are under high tension If spring or shaft is in the way measure above spring or shaft on the garage door centerline and mark as location for header bracket DO NOT ATTEMPT TO MOVE ADJUST OR REMOVE DOOR SPRING A CAUTION Header Bracket must be fastened to garage framing DO NOT fasten to drywall particle board plaster or other such materials Attaching Door Arm to Door ia Bracket and Shuttle uve sac naroware 8a Secure emergency release handle to cord K and attach emergency release cord to carriage in rail 8b Using the emergency release cord disengage the shuttle carriage 8c Sectional Doors typically accept curved door arm D In some cases straight door arm F may be used if the door bracket is mounted on the top edge of door 8d With the door closed the angle from door arm D to header is 30 max Note One Piece Door Top Edge Face Mount instructions are in the Operation and Maintenance Manual provided Clevis pin A lt D Door bracket tter pi lt g pin J fre pin oor bracket 4 Door end rail section lt Header 3 8 16 x 7 8 Bolt amp 3 8 Lock nut Connecting Power For Grounded Outlet connection 12a Plug in the power cord Coil excess cord and tape or twist tie it to top of powerhead DO NOT PLACE ABOVE LIGHT BULBS A WARNING Opener is equipped with grounded electrical plug for your protection and only fits grounded electrical
4. P N 37067501312 Recommended Tools Parts Included ASSEMBLY INSTALLATION POSTER A WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ AND FOLLOW ALL SAFETY INSTALLATION AND OPERATION INSTRUCTIONS If you have 70705 00706 Chain Belt Drive Models Potential Hazards Overhead doors are large heavy objects that move with the help of springs under high tension_and_electric motors Since moving objects springs under tension and electric motors can cause injuries your safety and the safety of others depends on you reading the information in this installation poster If you have questions or do not understand the information presented call The Genie Company or your local Genie Factory Authorized Dealer In this section and those that follow the words Danger Warning and Caution are used to emphasize important safety information A Danger indicates an imminently hazardous situation which if not avoided will result in death or serious injury A Warning indicates a potentially hazardous situation which if not avoided could result in death or serious injury A Caution indicates a potentially hazardous situation which if not avoided may result in injury or property damage Note is used to indicate important steps to be followed or important considerations Pre Installation Considerations This opener includes parts and supplies needed for installation in MOST garages and on MOST garage doors There are many varia
5. assembly and other hardware must be made by a trained service person using proper tools and instructions Remove all ropes and disable all locks connected to the door before installing operator Install door operator 7 feet or more above the floor Mount the emergency release knob 6 feet above the floor e DO NOT connect the operator to the source of power until instructed to do so e Locate the wall console button A Within sight of door B At a minimum height of 5 feet so small children cannot reach it C Away from all moving parts of the door Install the entrapment WARNING label next to the wall button or console Install the emergency release tag on or next to the emergency release handle The operator must reverse when the door contacts a 1 1 2 inch high object on the floor at the center of the doorway This is about the size of a 2 x 4 board laid flat A WARNING m moving door could result in serious injury or death e e Keep people clear of opening while door is moving nr e DO NOT allow children to play with the door operator e DO NOT operate a door that jams or one that has a broken spring A WARNING x An Electrical Shock could result in serious injury or death e Turn off power before removing operator cover e When replacing cover make sure wires are not pinched or near moving parts e Operator must be properly grounded A WARNING __ WARNING HIGH SPRING TENSION a N DO NOT try to remove repair or adj
6. cure wire with insulating staples and cut off excess wire Attach wires to wall console as shown From above insert opposite end of wire through control wire tube on powerhead and attach as shown Control wire tube Yoo Striped console 10e Mount wall console with 6 screws 10f Post ENTRAPMENT WARNING LABEL included in Manual next to the Wall Console Child can be pinned under automatic garage door Death or serious injury can result Note Some homes are pre wired for Safe T Beam devices Neverie enua wat or run under moving door Complete the connection and apply power If the sensor reparan la pinned push cantal Button opuss or wall console LEDs come ON wire routing is correct Test door opener m You may need to wire one sensor at a time to confirm wire routing in some cases Test door opener monthly A WARNING Use of any other wall control can cause unexpected operation of the door and loss of lighting feature Locate wall console within sight of door and far enough from door to prevent contacting it while operating the console Control must be at least 5 feet above floor to prevent small children from operating it BLUE BAG b Cotter pin x2 Clevis pin x2 3 8 16 x 7 8 Bolt x2 Header bracket M 1 4 14 x 3 4 al Tapered flange screw x6 3 8 Lock nut x2 ORANGE BAG l Clevis pin l
7. lide into rail connector J until it locks 1g Slide gear assembly to front end of opener end rail section A Turn rail assembly over and place drive gear assembly in slots Insert two screws to fasten assembly to the rail 8 x 3 4 Drive gear Self tapping screw assembly The drive gear assembly is loose and must be pulled towards the slots and fastened Be certain the tension bracket is hooked into the rail as shown in illustration 2c Mounting Powerhead to Ceiling creen Bac hardware 6a Find and mark ceiling at center line of door For finished ceilings attach cross piece not supplied to joists Cross piece a location _ Jvc lt Door centerline gt aN Fi a Z Attach mounting straps G to joists or cross piece with 2 lag screws 5 16 x Way lag pus 1 3 4 provided in green bag Lh not included While supporting opener unit open door and raise opener unit to clear door so it passes the rail clearly Secure opener unit in position to mounting straps with nuts and bolts KU LT ARZ Note Rail should be level to floor For tall garage ceilings additional hanging angle and hardware may be required and is available at leading retail stores Finished Ceiling Attach to joists Installing Wall Console a CLEAR BAG hardware 10a Route wire from powerhead to desired location for wall console Some homes are pre wired and they may not be color coded Se
8. oam cushion from underside of powerhead foam cushion Attaching Door Bracket to Door ia ORANGE BAG hardware Sectional Door Typical 7a Center bracket on door higher than the top set of door rollers 7b Using bracket mark holes on door or frame 7c Drill 1 8 holes 7d Secure with 1 4 20 x 3 4 self drilling screws 7e Some garage door manufacturers provide door brackets that CAN be used with your Genie Door Arms Door centerline Top Roller Sectional Door Wooden 7a Center bracket on door higher than the top set of door rollers 7b Using bracket mark holes on door or frame 7c Drill 1 8 holes completely through door 7d Fasten bracket with 5 16 x 2 carriage bolts and nuts not furnished Door centerline Note One Piece Door Top Edge Face Mount instructions are in the Operation and Maintenance Manual provided A CAUTION Doors made of masonite lightweight wood fiberglass and sheet metal must be properly braced before mounting door opener Contact door manufacturer or distributor for any questions or concerns The Genie Company is not responsible for any damage caused due to an improperly braced door Compact CFL bulbs can be used Motor Cover gt S Note DO NOT exceed maximum wattage Each light bulb should be no more than 100W Model 2562 requires light bulbs of no more than 60 watts 11b Insert powerhead lens hinge E into slots in motor cover on powerhead F 11c
9. ong Wire clip x4 CB amip 5 16 x 1 3 4 i NG 1 4 20 x 3 4 Lag screw x2 Door bracket Release handle Push nut Self drilling screw x3 GREEN BAG 5 16 x 1 3 4 Lag screw x2 8 x 3 4 1 4 x 3 4 Self tapping Insulated staple x30 screw x2 uu 5 16 18 Lock nut 5 16 18 x 3 4 1 4 x 1 1 4 Safe T Beam Safe T Beam serrated x2 Bolt x2 Lag screw x4 sensor source Adjusting Rail Tension 2a The chain belt needs to be tightened inside the rail 2b Make sure carriage and bullet are not engaged To disengage the carriage pull the red cord 2c Prior to tightening check to make certain the tension bracket is hooked into the rail as shown in illustration 2c Tighten tension nut until chain belt is approximately 1 8 above bottom edge of rail Measure at midpoint of rail Attaching Rail to Powerhead BLUE BAG hardware 3a Turn the rail with open side toward the powerhead Lower drive gear over spline shaft on top of opener with the lights facing away from the door Place rail mounting bracket s G over rail and align with holes in opener On Belt drive models align belt guide bracket I tongue with slot and align holes in opener On Chain drive models utilize a second mounting bracket G and align with holes in opener 3d Fully tighten 1 4 x 14 x 3 4 screws Do not over tighten Note To prevent damage to motion sensor not on all models Piee DO NOT remove f
10. outlets DO NOT alter plug in any way If you have no grounded outlets have one installed by a licensed electrician Opener must be properly grounded to prevent personal injury and equipment damage NEVER USE AN EXTENSION CORD Check local building codes for any requirement that you must have a permanent hard wired connection NEVER REMOVE MOTOR COVER All work inside cover must be performed by a licensed electrician using proper tools and instructions For Permanent Wiring by an Electrician 12a Cut existing wires OUTSIDE CHASSIS 12b The wire connections must be made INSIDE CHASSIS and there must be at least 6 of new power supply line wire INSIDE CHASSIS Conduit is optional Conduit strain relief and wire nuts are not provided 1 Ready to Program Refer to Operation and Maintenance Manual for programming instructions A CAUTION DO NOT run opener until travel limits have been set to avoid damage to unit
11. tions of garages and garage doors A few additional parts and supplies may be needed for installation in YOUR garage and to YOUR garage door While going over these instructions please note the additional items you may need For help finding a local Genie Professional Dealer call 1 800 OK GENIE or Customer Service at 1 800 35 GENIE Is there an electrical outlet within approximately 3 of the point where the powerhead will be If not you need to contact a licensed electrician Check condition of the door and all its associated hardware Tracks springs hinges rollers Is anything loose or appear worn If so call a trained professional for an evaluation and repairs if needed DO NOT ATTEMPT TO ADJUST SPRINGS OR THEIR ATTACHED PARTS Operate the door manually Does it move freely and smoothly Check the balance of the door by lifting it by hand approximately halfway open and let go It should stay put or move very slowly If not call a trained professional for repairs Remove all ropes and remove or disable all locks connected to the garage door It is also recommended that T handles be removed Closed loop lifting handles with no protruding parts can remain any questions or do not understand an instruction call The Genie Company or your local Genie Factory Authorized Dealer e DO NOT install operator on an improperly balanced door An improperly balanced door could cause severe injury Repairs and adjustments to cables spring
12. ust springs or anything to which door spring parts are fastened such as wood block steel brackets cables or other like items e Repairs and adjustments must be made by a trained door system technician using proper tools and instructions Need help or have questions DO NOT RETURN to the store Call us 800 354 3643 1 Check door height 8 doors require a Rail Extension Kit available at leading retail stores Rail Assembly GREEN BAG hardware 1a Slide the opener end rail section A to correct position 1b Slide the door end rail section C to correct position 1c Lift opener rail section A slightly and slide rail connector J onto middle rail section B 1d Lower opener rail end section A and slide into rail connector J until it locks Attaching Rail to Bracket ORANGE BAG hardware 5a Elevate opener assembly and position door end rail section C inside bracket Protective foam cushion Note Support opener and have a second person assist during this step Align holes in rail with holes in bracket Slide clevis pin through holes in rail and bracket and secure with push nut by pressing the push nut ends together Insert rubber plugs into powerhead accessory holes if present Clevis pin long Installing Safe T Beam YELLOW BAG hardware Position Safe T Beam source and sensor on Wall mount each side garage door 5 6 above floor Mark bracket mounting holes and secure with