1. 20 cm and seal with moisture resistant adhesive tape Run the vapor barrier 3 4 in 2 cm up the wall and trim after the wall base is installed The underlay must be installed prior to installation of laminate floors Do not overlap underlay edges Butt end edges together and seal with adhesive tape 3 Wood Subfloors e Wood subfloors must be structurally sound and screwed or nailed to supporting beams A 6 mil 0 15 mm polyethylene vapor barrier must be used if installing laminate floors over wood subfloors applied directly to concrete If installing floors over a crawl space install a 6 mil 0 15 mm vapor barrier Overlap vapor barrier edges by 8 in 20 cm and seal with moisture resistant adhesive tape Run the vapor barrier 3 4 in 2 cm up the wall and trim after the wall base is installed Crawl space should be dry and vented as per local building code Underlay must be installed prior to installing the laminate floors Underlay edges should not be overlapped Butt end edges together and seal with adhesive tape 4 Vinyl sheet tile Linoleum Ceramic Tile Subfloors e If vinyl linoleum or ceramic tile is installed over concrete install an 6 mil 0 15 mm vapor barrier over it Overlap vapor barrier edges by 8 in 20 cm and seal with moisture resistant adhesive tape Run the vapor barrier 3 4 in 2 cm up the wall and trim after the wall base is installed Underlay must be installed prior to installing the lamin
2. a minimum of 64 F 18 C with a maximum relative humidity of 75 EXPANSION TrafficMASTER laminate floors expand and contract with changes in relative humidity For this reason leave a 3 8 in 10 mm expansion space around the perimeter of the room and all other objects such as toe kicks and plumbing The expansion space will be covered by wall base moldings or quarter rounds once the floor is installed MAXIMUM ROOM SIZE ADJACENT ROOMS TrafficMASTER laminate floors can be installed in a single room up to 33 ft 10 m in length and 26 ft 8 m in width Installations in rooms that are over the maximum allowable length and width must use T moldings Also use T moldings when installing laminate floors to separate adjacent rooms i e through doorways INSTALLATION LAYOUT There are no rules when it comes to the layout of your installation Typically laminate flooring installations are laid out parallel to the longest wall in the room or perpendicular to the main window in the room SUBFLOOR PREPARATION TrafficMASTER laminate floors can be installed over many types of subfloors as long as they are properly prepared and meet the required criteria outlined in this section 1 General Subfloor Preparations amp Precautions e Subfloors must be clean and free of dirt and debris prior to installation e Subfloors must be structurally sound prior to installation e Subfloor moisture must be tested prior to installation and should not
3. exceed 12 through the installation area e Carpet is not a suitable underlay for laminate floors All carpet carpet pad and carpet tack should be removed prior to installation Variations in the subfloor flatness should not exceed 3 16 in per 10 ft 2 mm 2 m Floors must be leveled to meet this specification prior to installation Level by filling depressed areas with flooring leveling compound and sanding or grinding down any raised areas Installations over hydronic radiant heated subfloors are acceptable but temperatures should never exceed 80 F 27 C Radiant heat systems must be operating for a minimum of 3 weeks prior to installation of TrafficMASTER laminate floors to ensure the subfloor meets the moisture requirements 2 Concrete Subfloors e Concrete subfloors must be properly cured and allowed to dry for at least 60 days prior to installation Test the concrete subfloor for moisture prior to installation To do so i Tape 3 ft x 3 ft 91 cm x 91 cm pieces of polyethylene vapor barrier to the subfloor ii If condensation appears on the film after 24 hours or concrete appears dark in color moisture is likely present and a Calcium Chloride test must be performed iii The maximum allowable moisture emission is 5 0 Ibs 1000 ft per 24 hours 2 26 kg 92 9 m per 24 hours e A 0 12 in 3 mm thick underlay and 6 mil 0 15 mm polyethylene vapor barrier must be used when installing over concrete e Overlap vapor barrier edges by 8 in
4. of the second plank so that it overlaps the short edge groove of the first plank by half the width of the plank e Press down on the second plank so as to engage the locking mechanism and physically connect it to the first plank e The two planks should lock together tightly and there should be no height differences between them e Slide the second plank horizontally towards the wall until the two planks long edges are aligned Continue in this manner until the first row is complete Use the remainder of the last plank of the first row to start the second row provided that it is a minimum of 16 in 40 cm long If the cut piece is shorter than 16 in 40 cm long cut a new plank in half and use it to begin the second row m Installing All Other Rows Install the first plank of the second row by installing its long edge to the previous row s groove To install remaining planks install the long edge of the plank to the previous row e Before lowering the plank make sure it s short end tongue overlaps with the previous plank s short end groove e Lower the plank slowly a short oscillating or up and down motion may help lower the plank e Apply pressure to the short edge of the planks so as to activate the locking mechanism You will typically hear an audible click sound e When you are finished installing all rows remove all wall spacers and install wall base and applicable moldings transitions GENERAL CARE GUIDELINES e Place mats and area rug
5. INSTALLATION GUIDE Read all instructions before installation IMPORTANT TrafficMASTER laminate flooring is intended for a floating installation only Do not glue nail or attach in any other way to your existing subfloor Cabinets and kitchen islands should be installed prior to the laminate flooring PRECAUTIONS e Never tap laminate floors during installation Never use tools designed for other laminate flooring installation systems Never wax polish or use abrasive cleaners on laminate floors TrafficMASTER laminate floors should not be installed in rooms that are susceptible to moisture such as full bathrooms entryways or laundry rooms TOOLS AND MATERIALS Table or circular saw Gloves 6 mil 0 15 mm thick vapor barrier if installing over concrete Measuring tape Pencil marker Carpenter s square Pull bar Utility knife 3 8 in 10 mm thick spacers 2 in 51 mm wide moisture resistant adhesive tape Safety glasses Dust mask NIOSH designated Laminate floor underlayment SAFETY CAUTION Use safety glasses and gloves when cutting laminate floors Laminate floors will create wood dust always cut the product in a well ventilated area ACCLIMATION Allow 48 hours for your flooring to acclimate to the conditions of the installation area before opening the cartons Cross stack unopened cartons in the installation area away from outside walls heat and air conditioning vents Installation temperatures should be at
6. a evitar que se repitan y obtener los resultados m s naturales y variados e Inspecciona cada tabl n antes de instalarlo para ver si est da ada La primera y ltima fila de la instalaci n deben tener m s de 9 cm de ancho i Mide el ancho de la habitaci n y div delo por el ancho de los tablones que est s instalando li Si el resto es menor que 9 cm recorta 9 cm del ancho de la primera fila primera fila Si no es posible aseg rate de que ambos tablones del borde tengan un ancho lo m s parejo posible El primer y ltimo tabl n en una fila deben tener 40 cm de largo como m nimo Escalona los tablones de una fila a otra a 40 cm como m nimo Usa espaciadores para mantener el espacio de expansi n de 10 cm entre los tablones y los objetos verticales las paredes Selecciona una esquina de la habitaci n para empezar a trabajar de izquierda a derecha CONSEJO Con frecuencia es m s f cil comenzar desde la puerta de la habitaci n de manera que el primer tabl n pueda deslizarse f cil debajo de la jamba de la puerta vi 1 Instalaci n de la primera fila Coloca el primer tabl n con la leng eta del borde largo de frente a la pared Ubica la leng eta del borde corto del segundo tabl n de manera que coincida con la ranura del borde corto del primer tabl n a la mitad del ancho del tabl n Presiona sobre el segundo tabl n para trabar el mecanismo de cierre y que quede f sicamente conectado con el primer tabl n Ambos
7. acerlo usa un recorte de piso laminado y un pedazo peque o de piso base para sostener un hoja de sierra manual a la altura correcta y recortar Revisa los vanos de la puerta y ajusta las alturas si es necesario antes de instalar los pisos laminados Deja el espacio de expansi n adecuado debajo de la jamba de la puerta 9 Irregularidades de la pared Las paredes no siempre son perfectamente rectas Los pisos laminados TrafficMASTER necesitar n ser cortados para ajustarse a las irregularidades de tus paredes Sigue estos pasos i Instala la primera fila de pisos laminados siguiendo la secci n de Instalaci n y aseg rate de que todos los bordes largos de los tablones del piso laminado queden alineados ii Coloca la fila completa contra la pared As notar s cualquier irregularidad reas donde la pared no est recta iii Traza el contorno de la pared en la fila de piso laminado con un l piz o marcador iv A continuaci n desmontar las tablas con cuidado para no da ar el sistema de cierre y cortar a lo largo de la l nea trazada v A continuaci n desmonta los tablones con cuidado para no da ar el sistema de cierre y corta a lo largo de la l nea trazada Reinstala los tablones cortados y deja el espacio de expansi n necesario de 10 mm PROCEDIMIENTOS DE INSTALACI N Antes de comenzar con los pasos de la secci n de Instalaci n aseg rate de hacer lo siguiente e Ordena los tablones antes de la instalaci n par
8. ate floors Underlay edges should not be overlapped Butt end edges together and seal with adhesive tape ROOM PREPARATION 1 Wall Base Trim e Removal of the existing wall base trim is optional If the existing wall base trim is not removed leave the required expansion space in front of the existing wall base trim e Install wall base or trim after the flooring installation is complete to cover the expansion space around the perimeter of the room e Always nail adhere the wall base and trim to the wall Never nail adhere it to the laminate flooring 2 Doors Door Jambs Undercut door jambs so that the laminate floor can be installed under them To do this use a laminate flooring off cut and a small piece of underlay to support a hand saw blade at the correct height for undercutting e Check the door clearances and make any necessary height adjustments before installing laminate floors e Leave the correct expansion spacing under the door jamb 3 Wall Irregularities Walls are not always perfectly straight TrafficMASTER laminate floors need to be cut so as to fit within the irregularities of your walls Complete these steps i Install the first row of laminate floors following the Installation section and ensure that all long edges of the laminate flooring planks are aligned ii Slide the whole row against the wall You will now notice any irregularities areas where the wall is not straight iii Trace the contour of the wall o
9. ebles y otros muebles m viles e Usa tapetes protectores debajo de las sillas de oficina con ruedas e Evita el uso de lacas pulimentos ceras o limpiadores basados en detergentes ya que dejar n una pel cula en la superficie de tu piso y pueden causar da os irreparables La superficie de este piso no necesita renovaci n del acabado y mantendr su apariencia original e Nunca uses limpiadores abrasivos e No inundes tu piso ni uses un trapo mojado El uso excesivo de l quido sobre el piso puede hacer que los bordes de los tablones se hinchen y provocar da os irreparables e No uses un limpiador a vapor ya que el vapor puede hacer que los bordes de los tablones se hinchen y provocar da os irreparables INSTRUCCIONES DE LIMPIEZA DIARIA e Usa un trapeador o una aspiradora con accesorio para superficies duras para eliminar el polvo la suciedad o los residuos e Para una limpieza m s profunda que pueda requerir un limpiador usa uno a base de agua para pisos laminados Roc a ligeramente el limpiador sobre la superficie sucia y limpia de inmediato GARANT A TrafficMASTER TrafficMASTER ofrece garant a limitada contra defectos de f brica desde la fecha de compra de este producto TrafficMASTER garantiza que e La superficie laminada decorativa no se desgastar e La superficie de la tabla resistir las manchas e La superficie de la tabla no perder lustre ni color por causa de la luz natural o artificial Para preguntas sobre nues
10. ec rtala despu s de instalar la base de la pared El semis tano debe estar seco y ventilado seg n el c digo local de construcci n e El piso base debe instalarse antes que el piso laminado e Los bordes del piso base no deben superponerse 4 Pisos de vinilo l mina losa lin leo y losa de cer mica Si se instala vinilo lin leo o losas de cer mica sobre el concreto debe colocarse encima una barrera de vapor de 6 mil 0 15 mm Superp n los bordes de la barrera de vapor 20 cm y sella con cinta adhesiva resistente a la humedad Extiende la barrera para vapor 2 cm hacia arriba de la pared y rec rtala despu s de instalar la base de la pared El piso base debe instalarse antes que el piso laminado Los bordes de la base de piso no deben superponerse Unir bien los extremos y sellarlos con cinta adhesiva PREPARACI N DE LA HABITACI N 1 Moldura base de pared e Retirar la moldura base de pared existente es opcional Si no se retira la moldura base de pared deja el espacio de expansi n requerido frente aestos Instala la base de pared o moldura al completar la instalaci n del piso para cubrir el espacio de expansi n alrededor del per metro de la habitaci n Siempre debes clavar adherir la base de pared o moldura a la pared Nunca las claves adhieras al piso laminado N Puertas jambas de puerta Recorta las jambas de puertas en la parte inferior para que el piso laminado pueda instalarse debajo de ellas Para h
11. lan los criterios requeridos descritos en esta secci n 1 Precauciones e indicaciones generales para acondicionar el contrapiso e Los contrapisos deben debe estar limpios y sin polvo ni escombros antes de la instalaci n Los contrapisos tienen que estar estructuralmente estables antes de la instalaci n Antes de la instalaci n debe medirse el nivel de humedad que no debe superar el 12 en ning n lugar del rea de instalaci n La alfombra no es una base adecuada para pisos laminados Todas las alfombras almohadillas y tachuelas para alfombras deben retirarse antes de la instalaci n Las variaciones en el nivel horizontal del contrapiso no deben superar los 4 8 mm cada 3 m 2 mm 2 m Los contrapisos tienen que nivelarse hasta cumplir esta especificaci n antes de la instalaci n Nivela rellenando las reas hundidas con compuesto para nivelaci n de pisos y lija o pule cualquier rea levantada Es posible instalar sobre contrapisos hidr nicos de calefacci n radiante si la temperatura no supera los 80 F 27 C Los sistemas de calefacci n radiante tienen que estar funcionando al menos 3 semanas antes de instalar los pisos laminados TrafficMASTER para asegurarte de que el contrapiso cumple con los requisitos de humedad 2 Contrapisos de concreto e Los contrapisos de concreto deben curarse adecuadamente y hay que dejarlos secar durante al menos 60 d as antes de la instalaci n Verifica la humedad del contrapiso de concreto ante
12. ma cruzada en el rea de instalaci n alejadas de las paredes exteriores el calor y las rejillas de ventilaci n del aire acondicionado Las temperaturas de instalaci n deben estar a 64 F 18 C como m nimo con una humedad relativa m xima del 75 EXPANSI N Los pisos laminados TrafficMASTER se expanden y contraen con los cambios en humedad relativa Por esta raz n deja 10 mm de espacio de expansi n alrededor del per metro de la habitaci n y todos los objetos como z calos e instalaciones de plomer a El espacio para expansi n se cubrir con molduras de base de pared o cuartos de bocel una vez que el piso est instalado TAMA O M XIMO DE HABITACI N HABITACIONES ADYACENTES Los pisos laminados TrafficMASTER pueden instalarse en una sola habitaci n de hasta 10 m de largo x 8 m de ancho Las instalaciones en habitaciones que superan el largo y ancho permitidos requieren molduras en T Adem s usa molduras en T al instalar pisos laminados para separar habitaciones adyacentes es decir en umbrales DISPOSICI N PARA LA INSTALACI N No hay reglas para el dise o disposici n espacial de las instalaciones Generalmente las instalaciones de pisos laminados se colocan en paralelo a la pared m s larga o perpendicularmente a la ventana principal de la habitaci n PREPARACI N DEL CONTRAPISO Los pisos laminados TrafficMASTER pueden instalarse sobre muchos tipos de contrapisos siempre que se acondicionen bien y cump
13. nto the row of laminate flooring with a pencil or marker iv Once traced uninstall the planks carefully so as not to damage the locking system and cut along the traced line v Re install the planks leaving the necessary 3 8 in 10 mm expansion space INSTALLATION PROCEDURES Before you begin the steps in the Installation section ensure you have completed the following e Sort planks before installation to avoid plank repetition and to achieve the most natural and varied results e Inspect every plank for damage before installing it e The first and last row of the installation should be wider than 3 5 in 9 cm i Measure the width of the room and divide it by the width of the planks you are installing li If the remainder is less than 3 5 in 9 cm cut 3 5 in 9 cm from the width of the first row If this is not possible ensure that both edge planks are as even in width as possible e The first and last plank in a row should be a minimum of 16 in 40 cm long e Stagger the planks from row to row by a minimum of 16 in 40 cm e Use spacers to maintain the 3 8 in 10 cm expansion space between the planks and walls vertical objects e Select a starting corner of the room and work from left to right TIP It is often easiest to start at the door of the room so that the first plank can be easily slid under the door jamb ak Installing the First Row Lay the first plank with the long edge tongue facing the wall Position the short edge tongue
14. s at main entrances to minimize abrasive debris that may be tracked in on shoes e Place protective pads under furniture legs and other movable furniture e Use protective mats under wheeled office type chairs e Avoid using lacquers polishes waxes or detergent based cleaners as they will leave a film on the surface of the floor and may cause irreparable damage The surface of this flooring does not require refinishing and will maintain its original appearance e Never use abrasive cleaners e Never flood your floor or wet mop it Excessive liquid on your floor may cause plank edges to swell and become damaged beyond repair e Never use a steam cleaner as the steam may cause plank edges to swell and become damaged beyond repair DAILY CLEANING GUIDELINES e Use a dust mop or vacuum with a hard surface attachment to remove dust loose dirt or debris e For a more thorough cleaning where a cleaning solution may be required use a water based laminate floor cleaner Lightly mist the cleaner onto the soiled surface and wipe up immediately TrafficMASTER WARRANTY TrafficMASTER offers a limited warranty against manufacturing defects from date of purchase on this product TrafficMASTER guarantees that e The decorative laminate surface will not wear through e The surface of the plank will resist staining e The surface of the plank will not fade or discolor due to natural or artificial lighting For questions regarding our products please call
15. s de la instalaci n Para hacerlo i Pega con cinta adhesiva tiras de 91 cm x 91 cm de la barrera de vapor de polietileno en el contrapiso li Si aparece condensaci n sobre la pel cula luego de 24 horas o el concreto se oscurece es muy probable que haya humedad y es necesario realizar una prueba de cloruro de calcio iii El m ximo permitido de emisi n de humedad es 2 26 kg 92 9 m cada 24 horas e Al instalar sobre concreto usa un piso base de 3 mm de grosor y una barrera de vapor de polietileno de 6 mil 0 15 mm e Superp n los bordes de la barrera de vapor 20 cm y sella con cinta adhesiva resistente a la humedad e Extiende la barrera para vapor 2 cm hacia arriba de la pared y rec rtala despu s de instalar la base de la pared e El piso base debe instalarse antes que el piso laminado e No superpongas los bordes del piso base Une bien los extremos y s llalos con cinta adhesiva 3 Contrapisos de madera e Los contrapisos de madera tienen que ser estructuralmente estables y atornillarse o clavarse a las vigas de soporte Debe usarse una barrera contra vapor de polietileno de 6 mil 0 15 mm al instalar pisos laminados sobre contrapisos de madera aplicados directamente al concreto e Alinstalar los pisos sobre un semis tano instala una barrera para vapor de 6 mil 0 15 mm Superp n los bordes de la barrera de vapor 20 cm y sella con cinta adhesiva resistente a la humedad Extiende la barrera para vapor 2 cm hacia arriba de la pared y r
16. tablones deben quedar firmemente unidos y sin diferencias de altura entre ellos Desliza el segundo tabl n de manera horizontal hacia la pared hasta que los bordes largos de los dos tablones queden alineados Contin a de esta manera hasta completar la primera fila Usa el resto del ltimo tabl n de la primera fila para comenzar la segunda si quedaron al menos 40 cm de largo Si la pieza cortada es menor de 40 cm corta un tabl n nuevo a la mitad y salo para comenzar la segunda fila N Instalaci n de las dem s filas Instala el primer tabl n de la segunda fila con su borde largo hacia la ranura de la fila anterior Para montar los tablones restantes instala el borde largo del tabl n en la fila anterior Antes de bajar el tabl n aseg rate de que la leng eta del borde corto coincida con la ranura del borde corto del tabl n anterior Baja lentamente el tabl n puede ayudar un corto movimiento oscilante o hacia arriba y abajo Presiona el borde corto de los tablones hasta activar el mecanismo de cierre Por lo general oir s un clic Cuando termines de instalar todas las filas quita todos los espaciadores de la pared e instala la base de pared y las molduras transiciones correspondientes INSTRUCCIONES GENERALES DE CUIDADO e Coloca tapetes y alfombras de rea en las entradas principales para reducir la cantidad de residuos abrasivos que pueden adherirse a los zapatos e Coloca almohadillas protectoras debajo de las patas de los mu
17. toll free 1 888 864 4520 GU A DE INSTALACI N Lee todas las instrucciones antes de la instalaci n IMPORTANTE El piso laminado TrafficMASTER fue creado para instalaci n flotante nicamente No lo pegues claves ni fijes de ninguna otra manera sobre el contrapiso existente PRECAUCIONES e Nunca golpees los pisos laminados durante la instalaci n e Nunca uses herramientas dise adas para otros sistemas de instalaci n de piso laminado Nunca coloques cera pulas ni uses limpiadores abrasivos en los pisos laminados Los pisos laminados TrafficMASTER no deben instalarse en habitaciones que puedan tener humedad como ba os completos entradas o lavander as HERRAMIENTAS Y MATERIALES Sierra circular o de mesa Guantes Barrera contra vapor de 6 mil 0 15 mm de grosor si se instala sobre concreto Cinta de medir L piz marcador Escuadra de carpintero Barra de tracci n Cuchillo de uso general Espaciadores de 10 mm de grosor Cinta adhesiva resistente a la humedad de 51 mm de ancho Gafas de seguridad M scara contra el polvo certificada por NIOSH Base para piso laminado ADVERTENCIA DE SEGURIDAD Al cortar este producto usa gafas de seguridad y guantes Los pisos laminados generan aserr n corta siempre el producto en un rea bien ventilada ACLIMATACI N Antes de abrir las cajas deja que los pisos se aclimaten por 48 horas a las condiciones del rea de instalaci n Apila las cajas sin abrir de for
18. tros productos llamar por favor al tel fono gratis 1 888 864 4520

Download Pdf Manuals

image

Related Search

Related Contents

User Manual UR5/CB3  FCL NY CLEC Price Guide 20140120  ワンタッチボスタースタンド 取扱説明書  Home Decorators Collection 0347200210 Instructions / Assembly  Manual de instrucciones testo 477  PBI 17 recto - FDGDON Réunion  Istruzioni per l`uso / T Control Pro  SoftLogix Controllers, Version 21  MANUAL DEL USUARIO RECORTADORA DE  取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file