Home

Florida Pneumatic FP-823 Use and Care Manual

image

Contents

1. AX PLEASE READ AND FOLLOW ALL WARNINGS f AIR TOOLS FP823 3 Mini Sander Kit Read Operating Instructions Always become familiar with all the instructions and warnings before operating any power tool Always Wear Approved Eye Protection Impact resistant eye protection should meet or exceed the standards as set forth in the United States ANSI Z87 1 Occupational and Educational Eye and Face Protection Look for the marking Z87 1 on your eye protection to insure that it is an approved style For further information ANSI 287 1 Occupational and Educational Eye and Face Protection is available from the American National Standards Institute Inc 11 West 42nd Street New York NY 10036 Hearing Protection is Recommended Hearing protection should be used when the noise level exposure equals or exceeds an 8 hour time weighted average sound level of 85 dBA Process noise reflective surfaces other tools being operated nearby all add to the noise level present in your work area If you are unable to determine your noise level exposure we recommend the use of hearing protection Avoid Prolonged Exposure to Vibration Tools can vibrate during use Prolonged exposure to vibration or very repetitive hand and arm movements can cause injury Stop using any tool if discomfort tingling feeling or pain occurs You should consult your physician before resuming use of the tool 90 PSIG Maximum This tool is designed t
2. 27 9403 Description Florida Pneumatic 3 mini sander is intended for all medium duty sanding applica tions Its orbital action and 3 pad diameter assures swirl free finishes on flat areas Safety Instructions The following instructions are furnished as general guidelines for use of your pneumatic tool They cannot compre hensively cover all possible or conceiv able uses of the subject tool For additional information on the safe use of air tools we advise you to obtain a copy of CAGI B186 1 2009 Safety Code for Portable Air tools from the following source COMPRESSED AIR AND GAS INSTITUTE 1300 Sumner Avenue Cleveland OH 44115 2851 PH 216 241 7333 Www cagi org Or from Florida Pneumatic MFG Corp 851 Jupiter Park Lane Jupiter FL 33458 PH 561 744 9500 The use of the word shall in the following instructions indicates that adherence to the particular require ment is necessary to conform to CAGI B186 1 2009 Tool Application and Usage Portable tools shall be used only for y the purposes intended in their design and within the capacity for which the were intended and rated It shall be the tool owner s and or employer s responsibility to instruct each operator Read these instructions carefully before attempting to install operate or service this Florida Pneumatic product Failure to comply with the instructions could result in personal injury and or property damage in the safe use of the too
3. ce AiR TOOLS FP823 3 Mini Sander Kit FP823 3 Mini Sander Kit AIR TOOLS Pad SiZ ccenn nonne es ee aed ee ee ee A 3 Free Speed isiecc ied die os antes E Ne eee 15 000 RPM SPINGIS threadi ceeace edeageteesvatedessesstersseeeideestieeeyieeevenst 5 16 X 24 Weini sei ses vaess cds cdes tasks sa cencae E R 1 2 3 Ibs Races gues laine a fee tcc sa cess ss cases cues ae caeeens odes aves AE A eee eee eee 4 5 8 3 8 D ie Sate EE E pegs welds eengy A cate ede ata abies A E E ere 1 1 2 PAU UM GE arenen a a E RE 1 4 NPT Maximum operating PreSSUre c ccccececeeceeeeeeeeeeeeeceeeeeeeeeeeceeeeteeseciieeeeeeeeaee 90 PSI Parts Breakdown for FP823 Note always use accessories with an RPM rating that meets or exceeds the tool RPM rating Always examine accessories before mounting for chips cracks or signs of damage Never use accessories that have been dropped or exposed to water solvent or extreme tempera ture changes It is a good practice to operate the tool in a protected enclosure for one minute after mounting any accessory Replacement Parts for FP 823 a foraotos arnt ad s 3 ors 725146fvaive Stem wit Rubber space 1 19 osons cymer Ja 2 z losos scew a at foeoonor2 Front Pistowit200 Rng 8 scoorar ituser daje olos pnt 2s feoeo ovine fa 1 24 eeooros spacer Jal f e ome _t 25 oeoo votorkocenut 12 loso0104 trigger a 26 focootto Ruvercrp Ja
4. l Tools shall not be used without guards and safety devices as furnished by the manufac turer Where an air tool is modified or altered the modifier shall provide the safeguards to enable it to be safely used in the operations intended and to comply with any applicable provisions as contained in CAGI B186 1 2009 Tool Installation Pressure regulators shall be used to limit air pressure to the rated pressure where the supply pressure exceeds the tool s rated pressure Air hoses and lines shall be relieved of compressed air before being disconnected or disjointed unless there is automatic valve closing protec tion at the joint being separated Syn thetic lubricants which can cause deterioration of elastomer seals shall not be used in air systems of air tools Tool Maintenance It shall be the tool owner s and or employer s responsibility to assure that tools are maintained in a safe operating condition Tool maintenance and repair shall be performed by authorized trained competent personnel Tools shall be disconnected from their compressed air supply before repairs are attempted Repairs shall be consistent with the manufacturer s recommended proce dures Tool hoses and fittings shall be replaced if unsuitable for safe operation It shall be the tool owner s and or employer s responsibility to keep required rating markings and warnings on the tool in legible condition Retain these instructions for future referen
5. o operate at S0psig an air pressure of 90 pounds per square inch gauge pressure 90 PSIG maximum at the tool Use of higher air pressure can and may cause injury Also the use of higher air pressure places the internal components under loads and stresses they were not designed for causing premature failure The air supply should be clean and dry preferably lubricated For best results drain the moisture from your compressor daily WARNING Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to cause cancer birth defects or reproductive harm Some examples of these chemicals are Lead from lead based paints e Crystalline silica from bricks cement and other masonry products e Arsenic and chromium from chemi cally treated lumber Your risk from these exposures varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as those dust masks that are specially designed to filter out microscopic particles More than 1 100 slope More tran Tion dap i Main line 3 times Branch line 2 times Mise P i ome tegul Tool inlethose size skh ubric Tool inlethhose size Florida Pneumatic Manufacturing Corporation 851 Jupiter Park Lane Jupiter Florida 33458 Toll Free 1 800 3
6. ta osoor06 Air Reguator a 27 osz spene Ta a loosorna fpangearng 1 28 focoorar a fa a e ala a a wlos foo Ss tt CT Limited Warranty Florida Pneumatic warrants its tools to be free from defects in material and workmanship for two years from the date of purchase This warranty does not apply to tools which have been abused misused modified or repaired by someone other than Florida Pneumatic or its authorized service centers If a Florida Pneumatic proves defective in material of workmanship within one year after purchase return it to any authorized service center or to Florida Pneumatic freight prepaid Please enclose your name address and adequate proof of purchase date with a brief description of the defect Florida Pneumatic will at its option repair or replace defective tools free of charge Repairs or replacements are warranted as described above for the remainder of the warranty period Florida Pneumatic s sole liability and your exclusive remedy under this warranty is limited to repair or replacement of the defective tool There are no other warranties expressed or implied and Florida Pneumatic shall not be liable for incidental consequential or special damages or any other damages costs or expense of repair or replacement as described above

Download Pdf Manuals

image

Related Search

Related Contents

TOUT`ABSORB - Gamme absorbants  USER MANUAL  Un outil pour fabriquer des règles de vie avec les - CLPS-Bw  Here`s the Orcas manual  JVC CB-A260 User's Manual  ANTEVS User Manual - Frederick Vollmer  Mode d´emploi SCHICK - Fraiseuse S2 Master  取扱説明書ダウンロード(0.51MB  User Guide RES Power HD  Technical Manual - Revision January 2012  

Copyright © All rights reserved.
Failed to retrieve file