Home

Speakman SEF-1850 Installation Guide

image

Contents

1. INIMUM HOLE SIZE 20 SEF 1850 18 SEF 1 850 8 3 HOSES 24 MIN 36 MAX OPO OE COUNTERTOP HEIGHT HB COLD SUPPLY 6 LONG HOSE EYEWASH HOSE I HOT SUPPLY REPAIR PARTS MIN FROM WALL OR OBSTRUCTION 2 MAX DECK HEIGHT 2 1 4 SEF 1850 8 SIDE VIEW LESS HOSES MIN FROM WALL 7 1 2 6 7 1 OR OBSTRUCTION 10 7 8 2 MAX DECK HEIGHT 2 1 4 NOTE UNLESS OTHERWISE SPECIFIED ALL INLETS ARE 3 8 COMPRESSION WITH FEMALE THREADS UNLESS OTHERWISE SPECIFIED ALL DIMENSIONS ARE IN INCHES AND ARE SUBJECT TO CHANGE WITHOUT NOTICE
2. Instructions for Models SEF 1 850 SEF 1 850 8 EYESAVER Combination Faucet Need Help For additional assistance or service call SPEAKMAN Company 400 Anchor Mill Road New Castle DE 19720 PHONE 800 537 2107 EMAIL customerservice speakmancompany com WEB www speakmancompany com 92 SEF 1850 R3 What You Need To Know Tools Required Crescent Wrench Helpful Flat Head Screwdriver gt Important Notes The supply line for this unit shall provide an uninterruptible supply of flushing fluid at a minimum of 30 psi flowing pressure If shut off valves are installed in the supply line of the eyewash provisions shall be made to prevent unauthorized shut off ANSI Z358 1 requires that all emergency equipment shall be tested weekly to verify proper operation and inspected annually to assure conformance with ANSI Z358 1 requirements Be sure to read instructions thoroughly before beginning installation Do not overtighten any connections or damage may occur Safety Tips Cover your drain to prevent loss of parts Always wear eye protection Maintenance Keep the EYESAVER faucet looking new by cleaning it periodically with a soft cloth Avoid abrasive cleaners steel wool and harsh chemicals as these will dull the finish and void your warranty Q Turn off water supply Verify diameter of hole in countertop is a minimum of 1 1 4 Install mounting studs int
3. installed Tighten first by hand followed by the supplied aerator wrench O SPEAKMAN 05 1899 i NOTE If shut off valves are installed in the supply line of the eyewash provisions shall be made to prevent unauthorized shut off 11 Lift eyewash handle to activate the eyewash and test for proper operation See chart and notes at right Eyewash Flow Data Z f z FTU XS x y NS F VN A E VN o IT 7323 PE PIS IE Jua 2 7T x N y 2 12 The faucet spout was designed to swivel from left to right If a non swivel spout is preferred remove top cover from body Next remove allen head set screw from position 1 as seen below Center the spout between the handles and install the previously removed set screw into position 2 and tighten DO NOT OVERTIGHTEN Replace cap SEF 1850 FLOWING PLUME FLOWING PLUME PRESSURE pee Re DISTANCE A PRESSURE ks DISTANCE A NOTE If plume heights are low check to ensure that your supply valves are fully open If there is a noticeable height difference between the two plumes remove the aerators and flow controls and remove any debris that would inhibit the flow of water ROUGH IN MEASUREMENTS SEF 1850 SIDE VIEW LESS HOSES 9 FRONT VIEW 130 I 5 1 8 X IS SS N T 1 1 4 M
4. o base of faucet Install bottom washer over hoses and slide up to meet the base of the faucet Place hoses through hole in countertop sink one at a time Place faucet with studs through hole 3 From beneath countertop slide the rubber mounting washer then brass mounting washer over the mounting studs Thread two 2 brass nuts onto mounting studs Align faucet square to sink and tighten mounting nuts A F Locate the other blue hose attached to faucet and connect it to the F port on the the supply tee Tighten HSY M3A3 A Locate blue supply hose with the tag reading EYEWASH Connect Retrieve the 6 long blue hose from the box and connect it to the to the E port of the supply tee with check valves and tighten remaining port off the tee Tighten 4mm i 22 z HSY CAUTION HOSES PROVIDED INCLUDE RUBBER COMPRESSION WASHERS FOR SEALING DO NOT OVERTIGHTEN 7 Connect the short blue hose from the tee to the cold supply valve and 9 Before installing aerator turn on both hot and cold faucet the red hot supply hose to the hot supply valve handles This will clear out any debris from the supply lines Tighten both supply connections Open both supply valves and 10 Close both hot and cold faucet handles The aerator can now be check for leaks

Download Pdf Manuals

image

Related Search

Related Contents

HEC-102x-E-R Harsh Environment Controller  JAI CV-M300 Security Camera User Manual  取説PDF - セキスイ E-Shop  Riduttori industriali della serie MC  1. Appareil d`anesthésie    デタミナーCL IL-2R  Full Paper  Sony Ericsson J110 User's Manual    

Copyright © All rights reserved.
Failed to retrieve file