Home
Florida Pneumatic FP-793BL Use and Care Manual
Contents
1. PLEASEREAD AND FOLLOWALLWARNINGS A Read Operating Instructions Always become familiar with all the instructions and warnings before operating any power tool Always Wear Approved Eye Protection Impact resistant eye protection should meet or exceed the standards as set forth in the United States ANSI Z87 1 Occupational and Educational Eye and Face Protection Look for the marking 287 1 on your eye protection to insure that it is an approved style For further information ANSI Z87 1 Occupational and Educational Eye and Face Protection is available from the American National Standards Institute Inc 11 West 42nd Street New York NY 10036 Hearing Protection is Recommended Hearing protection should be used when the noise level exposure equals or exceeds an 8 hour time weighted average sound level of 85 dBA Process noise reflective surfaces other tools being operated nearby all add to the noise level present in your work area If you are unable to determine your noise level exposure we recommend the use of hearing protection Avoid Prolorged Exposure to Vibration Tools can vibrate during use Prolonged exposure to vibration or very repetitive hand and arm movements can cause injury Stop using any tool if discomfort tingling feeling or pain occurs You should consult your physician before resuming use of the tool Florida Pneumatic ionof Florida Pneumatic Manufacturing Corporation 851 JupiterPa
2. 20 906205Z Ball Bearing 1 43 910018 Hex Key Wrench 21 947 407121 Air Regulator 1 46 947 407146 Valve Bushing Limited Warranty Florida Pneumatic warrants its tools to be free from defects in material and workmanship for two years from the date of purchase This warranty does not apply to tools which have been abused misused modified or repaired by someone other than Florida Pneumatic or its authorized service centers If a Florida Pneumatic tool proves defective in material or workmanship within two years after purchase return it to any authorized service center or to Florida Pneumatic freight prepaid Please enclose your name address and adequate proof of purchase date with a brief description of the defect Florida Pneumatic will at its option repair or replace defective tools free of charge Repairs or replacements are warranted as described above for the remainder of the warranty period Florida Pneumatic s sole liability and your exclusive remedy under this warranty is limited to repair or replacement of the defective tool There are no other warranties expressed or implied and Florida Pneumatic shall not be liable for incidental consequential or special damages or any other damages costs or expense of repair or replacement as described above Q hie iS get We etl A gpa oo deen hee 2
3. P 793BL air TOOLS Super Duty Impact Wrench Specifications Free Bolt Square Impacts MaxTorque Air Rec Hose Rec Air Description Model No Speed Capacity Drive Per ft lb Weight Length Inlet Size Air Cons RPM in in Min 90psi lbs in NPT lin Pres cfm 1 StraightImpactWrench FP 793B 5 000 1 1 4 1 1 400 1 800 23 25 14 1 2 1 21D 90psi 12 1 8 Ext Str ImpactWrench FP 793BL 5 000 1 1 4 1 1 400 1 800 26 22 1 2 1 21D 90psi 12 REF PARTS NO DESCRIPTION QTY REF PARTSNO DESCRIPTION 1 947 407101 Motor Housing 1 22 90R01608204 O Ring 2 9 PN04002308 Pin 1 23 943 403323 Spring 3 947 407103 Air Inlet 1 24 943 403324 Pin 4 947 407104 Trigger 1 25 947 407125 Anvil Bushing 5 947 407105 Valve Stem 1 27 9SP04001000 Spring Pin 6 947 407106 Reverse Valve Bushing 1 28 947 407128 Hammer Case 7 90R01908204 O Ring 1 29 947 407135 Gasket 8 943 403147 Valve Spring 1 30 947 407130 12 Screw 9 90R00705305 O Ring 1 32 947 407112 Side Plate 10 961902 Spring Pin 2 33 947 407108 Hammer Frame 11 947 407134 Gasket 1 34 947 407109 Hammer Cam 12 947 407220 Rear Cover 1 35 947 407111 Hammer 13 90610146 Ball Bearing 1 36 947 407102 11 Anvil 1 14 947 407114 Rear End Plate 1 947 4071L02 91 Anvil 1 L 9 15 947 407115 Rotor 1 37 910211 O Ring 16 947 407116 Rotor Blade 6 38 947 405112 Retainer Ring 17 9SP06001800 Spring Pin 2 39 940317 14 Spring Pin 18 947 407118 Cylinder 1 40 947 407160 Dead Handle 19 947 407119 Front End Plate 1 41 97H 753528 Screw
4. es for use of your pneumatic tool They cannot comprehensively cover all possible or conceivable uses of the subject tool For additional information on the safe use of air tools we advise you to obtain a copy of CAGI B186 1 2009 Safety Code for Portable Air Tools available from the following source COMPRESSED AIRAND GAS INSTITUTE 1300 Sumner Avenue Cleveland OH 44115 2851 Ph 216 241 7333 www cagi org OR from Florida Pneumatic Manufacturing Corp 851 Jupiter Park Lane Jupiter FL 33458 561 744 9500 www florida pneumatic com The use of the word shall in the following instructions indicates that adherence to the particular require ment is necessary to conform to CAGI B186 1 2009 ToolApplication and Usage Portable tools shall be used only for the purposes intended in their design and within the capacity for which they were intended and rated It shall be the tool owner s and or employer s responsibility to instruct each operator in the safe use of the tool Tools shall not be used without guards and safety QO Mare than 17100 A or property damage reference Read these instructions carefully before attempting to install operate or service this Universal Tool product Failure to comply with the instructions could result in personal injury and Retain these instructions for future FP 793B amp FP 793BL Super Duty Impact Wrench Rugged Construction with Bolt On Side Handle Combination Th
5. rk Lane Jupiter Florida 33458 561 744 9500 Fax 561 575 9134 Toll Free 1 800 327 9403 AIR TOOLS 90 PSIG Maximum This tool is designed to operate at An air pressure of 90 pounds per square inch gauge pressure 90 PSIG maximum at the tool Use of higher air pressure can and may cause injury Also the use of higher air pressure places the internal components under loads and stresses they were not designed for causing premature failure The air supply should be clean and dry preferably lubricated For best results drain the moisture from your compressor dally WARNING Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to cause cancer birth defects or reproductive harm Some examples of these chemicals are Lead from lead based paints Crystalline silica from bricks cement and other masonry products Arsenic and chromium from chemi cally treated lumber Your risk from these exposures varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as those dust masks that are specially designed to filter out microscopic particles 1 800 ft Ib Torque Unique Low Wear Pin less Hammer Design Weighs Only 26 8 Ibs Extended Anvil Shown Safety Instructions The following instructions are fur nished as general guidelin
6. rough Hole amp Friction Ring Anvil Precision Engineered Motor for Added Reliability devices as furnished by the manufac turer Where an air tool is modified or altered the modifier shall provide the safeguards to enable it to be safely used in the operations intended and to comply with any applicable provisions as contained in ANSI B186 1 Tool Installation Pressure regulators shall be used to limit air pressure to the rated pressure where the supply pressure exceeds the tool s rated pressure Air hoses and lines shall be relieved of compressed air before being disconnected or disjointed unless there is automatic valve closing protec tion at the joint being separated Syn thetic lubricants which can cause deterioration of elastomer seals shall not be used in air systems of air tools Tool Maintenance It shall be the tool owner s and or employer s responsibility to assure that tools are maintained in a safe operating condition Tool maintenance and repair shall be performed by authorized trained competent personnel Tools shall be disconnected from their compressed air supply before repairs are attempted Repairs shall be consistent with the manufacturer s recommended proce dures Tool hoses and fittings shall be replaced if unsuitable for safe operation It shall be the tool owner s and or employer s responsibility to keep required tating markings and warnings on the tool in legible condition FP 793B amp F