        Nature Power 38215 Instructions / Assembly
         Contents
1.                   10                                                                                                                               11           a e a     Page     1  INTRODUCTION    Thank you for purchasing the Nature Power Power Inverter  With our state of the art  easy to use  design  this product will offer you reliable service for providing AC power and 5V USB power for  your home  cabin  RV or Trailer  The Nature Power Inverter can run many AC powered appliances  when you need AC power anywhere  The 5V USB power can charge many USB powered devices   This manual will explain how to use this unit safely and effectively  Please read and follow these  instructions and precautions carefully     IMPORTANT SAFETY INFORMATION   This section contains important safety information for the Nature Power Inverter  Before using  the Nature Power Inverter  READ ALL instructions and cautionary markings on or provided with  the inverter  and all appropriate sections of this guide    The Nature Power Inverter contains no user serviceable parts     WARNING  FIRE AND OR CHEMICAL BURN HAZARD      Do not cover or obstruct any air vent openings and or install      a zero clearance compartment        WARNING  FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN   DEATH OR SERIOUS INJURY   e When working with electrical equipment or lead acid batteries  have someone nearby in case of  an emergency    e Study and follow all the battery manufacturer   s specific precautions when insta
2.         Page 5       Pos          Fuse or Circuit  Breaker    Disconnect  Switch       Power Inverter 12 V Battery Bank     38210   38215   Charger system    38310  sold separately is  38320  required to charge    the battery bank  when battery is  discharged     12V Battery Bank       The use of deep cycle battery is highly recommended for power inverter application      For battery size  you need to identify how much you will be using them between charges   Nature Power recommends you purchase as much battery capacity as possible  See more  on Battery Run time and Load in Section 4     Fuse or Circuit Breaker       DC rated fuse or DC rated circuit breaker connected along the DC positive line is required       For 38210  38310  select a fuse or circuit breaker with a minimum of 150 Adc      For 38215  select a fuse or circuit breaker with a minimum of 225 Adc      For 38320  select a fuse or circuit breaker with a minimum of 300 Adc      Based on the size of the battery bank chosen on the 12V Battery Bank above  determine the  overall short circuit current rating of the battery bank from the battery manufacturer  The fuse  or circuit breaker chosen has to be able to withstand the short circuit current that may be  generated by the battery bank     Disconnect Switch       Select a Disconnect Switch with the same or higher the rating of the selected fuse or circuit  breaker from the above       The Disconnect Switch is used to disconnect the DC power between the power inverte
3.        38310   Inverter 12V 1000W 38320   Inverter 12V 2000W    Page 4    3  INSTALLATION    WARNING  Nature Power recommends that all wiring be done by a certified technician or   electrician to ensure adherence to the applicable electrical safety wiring regulations and   installation codes  Failure to follow these instructions can damage the unit and could also   result in personal injury or loss of life    CAUTION    Before beginning your Nature Power Inverter Installation  please consider the following        The Nature Power Inverter base unit should be used or stored in an indoor area away from  direct sunlight  heat  moisture or conductive contaminants        When placing the unit  allow a minimum of three inches of space around the unit for optimal  ventilation           Understanding the unit features       AC Output Front Panel    Picture shown 38210     gt  Status Indicator  GFCI Output Display  On Off Switch    Output Port for optional  remote switch    USB Output    120       60      1000W8 3A continuous  Non Sinusoidal Output          DC Input Rear Panel    Fan    f DC Input Terminals  opening    Ground Terminal       Picture shown 38210    Material Prepare for Installation  Typical Wiring block diagram of the Power Inverter        Important  Choose your AWG by the distance you will mount your inverter from the battery  We  recommend stranded wire  Stranded wire does not fatigue or loose connections over time  It is  best to attach wires using crimped connectors
4.        Nature  POWER    Nature Power Inverters       Modified Sinewave 1000w 1500w       True Sinewave 1000     2000           Owner   s Manual          Modified Sinewave Series True Sinewave Series    For safe and optimum performance  the Power Inverter must be used properly  Carefully read and follow  all instructions and guidelines in this manual and give special attention to the CAUTION and WARNING  statements     PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE    Disclaimer   While every precaution has been taken to ensure the accuracy of the contents of this guide  Nature  Power Technology assumes no responsibility for errors or omissions  Nature Power reserves the  right to make changes to the product  specifications and this manual without notice  Therefore   check the website for manual updates as necessary  www naturepowerproducts com       Important   Please be sure to read and save the entire manual before using your Nature Power Inverter   Misuse may result in damage to the unit and or cause harm or serious injury  Read manual in its  entirety before using the unit and save manual for future reference     Table of Contents    Ts  INERODUC         iccse a a 3  2     PRODUCT                                                                4  3  INSIALLA HON                 5  Me UNI OPERATION                8  9  TROUBLESHOOTING                                        ai 10  0   SPECIFICA TONS                                                                               
5. al wear and tear  including chips  scratches  abrasions  discoloration or fading due  to usage or exposure to sunlight   accidents  damage during shipping to our service facility   alterations  unauthorized use or repair  neglect  misuse  abuse  failure to follow instructions for care  and maintenance  fire and flood     Nature Power Inverters are Made in China         Nature  POWER       Customer Service  1 800 588 0590  Email  Info naturepowerproducts com  Website  www naturepowerproducts com       Page 11    
6. ble to the Power Inverter DC positive terminal        a                       7       Connect the other end of the positive DC input cable to one of the terminal of the Disconnect  Switch       Connect a DC input cable between the other terminal of the Disconnect Switch and one side  of the terminal of the fuse holder       Connect a DC input cable between the other terminal of the fuse holder and the battery  positive terminal       Install the selected fuse to the fuse holder       Turn Disconnect Switch to ON position     Remote Switch  optional  Connection      Insert the Remote Switch to the RJ11 Remote Port located at the Front AC panel of the  Power inverter  Please note polarity  The part number is   RM1201 00 or   30001     Test the Power Inverter connection       Turn unit on by pressing and holding the On Off button on the main unit for about a second  until a beep sound occur  The    Status    light turns on indicating the Nature Power Inverter is  ON  Check the digital display show measured battery voltage and output power alternatively   Both AC output and 5V USB are now available       Plug in a small AC load like a 40W table lamp or small appliance to the AC socket to verify  AC is available  If AC is not available  the GFCI may be tripped  Reset the GFCI by pressing  the    RESET    button       The unit is successfully installed and functioning properly     Test the GFCI monthly       Use the following instruction to perform    monthly test on the GFCI to en
7. fication    38210 38215 38310 38320  Inverter         DC Input Voltage operating 10 5     15 5 VDC  range    11 8 VDC    5V  750 mA    SafetyandEnvironmental     gt   gt  S O  Certified to CSA C22 2 no  107 1  Agency Markings  Operating Temperature 0  C to 40  C  32  F to 104  F   Storage Temperature  20  C to 60  C   4  F to 140  F   Relative Humidity  Operating Altitude Up to 9 843ft  3000 meters  above sea level  Weights and Dimensions    5 3 Ibs 6 9 Ibs 6 0 Ibs 11 5 Ibs   2 4 kg   3 1 kg   2 7 kg   5 2 kg        Page 10    Weights 38210  5 3 Ibs  2 4 kg   38215  6 9 Ibs  3 1 kg   38310  6 0 Ibs  2 7 kg     38320  11 5 Ibs  5 2 kg    Dimensions 38210  12 3 x 6 9 x 3 4      31 2 x 17 5 x 8 7 cm   38215  15 0 x 6 9 x 3 4      38 2 x 17 5 x 8 7 cm   38310  12 6 x 6 9 x 3 4      32 1 x 17 5 x 8 7 cm   38320  16 3 x 9 1 x 4 3     41 4 x 23 0 x 11 cm        7  WARRANTY    One Year Limited Warranty   The limited warranty program is the only one that applies to this unit  and it sets forth all the  responsibilities of Nature Power  There is no other warranty  other than those described herein  Any  implied warranty of merchantability of fitness for a particular purpose on this unit is limited in  duration to the duration of this warranty    This unit is warranted  to the original purchaser only  to be free of defects in materials and  workmanship for one year from the date of purchase without additional charge  The warranty does  not extend to subsequent purchasers or users    Man
8. gh the fan holes       For RV installation  the unit has to be mounted flat on horizontal surface       Use mounting template below to mark the positions of the mounting screws       Drill the 4 mounting holes and place the inverter in position and fasten the inverter to the  mounting surface     qd 38215 150            38210 12 3              gt   il    E    1     amp     a                          38210 12 3       38215  15 0      lt  __   _  38310 16 3            gt     38320 12             gt     38320 9 1                   383206 9  4 383109 7       38310 12067           38320 16 3       Power Inverter Chassis Grounding Connection     DANGER  The Power Inverter   s chassis needs to be grounded properly  Never operate the  Power Inverter without it being properly grounded  Failure to do so will result in death or  serious injury           Connect the grounding cable   s ring terminal to the unit ground screw      Connect the other side of the cable to the common grounding point     Power Inverter DC Input Connection    CAUTION  Reverse the DC Input terminal will damage the unit and cannot be repaired   Damage caused by reverse polarity connection is not covered by the warranty       Connect one end of the negative      input cable to      Power Inverter DC negative terminal      Connect the other end of the negative DC input cable to the battery negative terminal       Make sure the Disconnect Switch is in the OFF position       Connect one end of the positive DC input ca
9. lling  using and  servicing the battery connected to the inverter    e Wear eye protection and gloves    e Avoid touching your eyes while using this unit        Keep fresh water and soap on hand in the event battery acid comes in contact with eyes  If this  occurs  cleanse right away with soap and water for a minimum of 15 minutes and seek medical  attention    e Use precautions by not smoking or having an open spark or fire near battery installations   Batteries contain flammable materials        Keep unit away from moist or damp areas    e Avoid dropping any metal tool or object on the battery  Doing so could create a spark or short  circuit which goes through the battery or another electrical tool that may create an explosion        WARNING  Shock Hazard  Keep away from children    e Avoid moisture  Never expose unit to snow  water etc        Unit provides 120 Vac  treat the         output socket the same as regular wall AC sockets at  home        WARNING  Explosion hazard        DO NOT use the Nature Power Inverter in the vicinity of flammable fumes or gases  Such as  propane tanks or large engines         AVOID covering the ventilation openings  Always operate unit in an open area        Prolonged contact to high heat or freezing temperatures will decrease the working life of the unit        Page 3    FCC INFORMATION  This equipment has been tested and found to comply with the limits for a Class B digital device   pursuant to part 15 of the FCC Rules  These limits are de
10. ollers found in  some fans  power tools and some power tools    AC charger may not like the modified sine wave  generate by the inverter  those appliances may not work or may be damaged if they are  connected to the inverter  If you are unsure about powering any device with the inverter  contact  the manufacturer of the device     Estimate Run time on Load  Following run time is an estimate based on using a 12V 120AH battery bank for reference  Actual  run time may vary        Page 9    5  TROUBLESHOOTING    To trouble shoot the unit  please note the error code display on the main unit and review the     Understanding the Error Codes    in section 4       Problem   Symptom   Solution    No output voltage  Turn unit ON by following the instruction in  And Status LED is Section 4 to turn unit ON  installed  is either blown or turn OFF    No AC output  GFCI was tripped Check load and reset the          Status LED is  Green    No Output  Status   Check error code on Verify the error condition and make  LED is in Amber display correction    Products Products connected to Products are not compatible with the  connected to unit unit do not accept modified sine wave output generated by the  malfunction or modified sine wave output   NATURE POWER Power Inverter  See    AC  overheat  38210  38215 only  Load on Power Inverter    in Section 4       6  SPECIFICATIONS    Note  Specifications are subject to change without notices     a as Modified Sinewave Series True Sinewave Series  Speci
11. r and  the battery bank during service  maintenance or trouble shooting     DC Input Cable       Low resistance wire  copper  is required for all the DC connections between the inverter and  the battery bank       For 38210  38310  uses minimum  2 AWG wire with maximum cable length of 5 feet       For 38215  use minimum  1 0 AWG wire with maximum cable length of 5 feet       For 38320  use minimum  2 0 AWG wire with a maximum cable length of 5 feet     Grounding Cable    Use minimum  10 AWG wire  Make sure you install the proper fuse or circuit breaker in the DC  positive line  The unit is grounded through the ground stud of the unit located near the DC Input  terminal  Use crimp ring terminal  lugs  to connect the grounding cable to the stud     Installing the Power Inverter System        WARNING  Electrical Shock Hazard   The unit    On Off    switch does not disconnect the DC power from the battery  Use the DC  Disconnect Switch or disconnect the DC input cables connection to disconnect the DC  power from the battery before working on any circuits connected to the unit  Failure to  follow these instructions can result in death or serious injury        Power Inverter Installation      Choose      appropriate mounting location     Page 6       For indoor use  the orientation of the unit can be mounted in any direction except with the DC  Input panel facing downwards  This is to meet electric codes  so in case the unit gets fire  any  hot debris cannot fall to the floor throu
12. signed to provide reasonable protection  against harmful interference in a residential installation  This equipment generates  uses and can  radiate radio frequency energy and  if not installed and used in accordance with the instructions   may cause harmful interference to radio communications  However  there is no guarantee that  interference will not occur in a particular installation  If this equipment does cause harmful  interference to radio or television reception  which can be determined by turning the equipment off  and on  the user is encouraged to try to correct the interference by one or more of the following  measures       Reorient or relocate the receiving antenna       Increase the separation between the equipment and the receiver       Connect the equipment into      outlet on a circuit different from that to which the receiver   is connected      Consult the dealer or an experienced radio TV technician for help     LIMITATIONS ON USE  Do not use in connection with life support systems or other medical equipment or devices     2  PRODUCT DESCRIPTION    The Nature Power Inverter package includes the items list below       Power Inverter base unit  one of the following models       38210  Inverter 1000w  Modified Sinewave    e 38215  Inverter 1500w  Modified Sinewave       38310  Inverter 1000w  True Sinewave    e 38320  Inverter 2000w  True Sinewave     Modified Sinewave series       38210   Inverter 12V 1000W 38215   Inverter 12V 1500W    True Sinewave series
13. sure the GFCI is  functioning properly       Turn unit on and plug a small AC load  40W light bulbs  to the GFCI       Check the AC load is ON       Press    Test    button and observe a click sound  Check AC load is turned off       Press    RESET    button and check the AC load is back ON again     4  UNIT OPERATION    WARNING  RISK OF EQUIPMENT DAMAGE       For 38210  38215  Do not plug surge protected power bars into the unit   s 120 VAC outlets  The  surge protected components on the surge protected power bar may not like the modified sine  wave output generate by the inverter             not connect an AC power source like utility power or generator to the unit 120 VAC outlets        Turn ON and OFF the 120 VAC and USB      Press and hold the    Power Select    button for 1 second until a beep is sounded  Display will  show the measured battery voltage and output power alternatively  Status LED will turn  green  Both 5V USB and 120 VAC are available       Press    Power Select    button to turn unit off     Remote ON  OFF  Optional      If optional remote is used  the Remote ON OFF momentary switch is connected in parallel  with the    Power Select    button on the unit  Same procedure applies to ON and OFF the unit     Understanding the Display  amp  Status LED  Display    125 Display shows measured battery voltage   0 80 Display shows total output AC power in kW  800W as shown       E01    Display shows error or warning code  See trouble shooting section in details  S
14. tatus LED    Green  Unit operation is normal    Page 8    Amber  Warning is detected  Unit will shutdown at any time  Please check error code to  troubleshoot the unit    Red  Error is detected and unit has shutdown  Please check error code to troubleshoot  the unit     Understanding the Error Code    and has shutdown restart unit  e                                and has shutdown charger is connected to the battery bank    E02  Unit output has sensed overload or   Check load connected to the output   E  05  7    short circuit and was shutdown Reduce load and restart the unit  04 Unit has sensed internal Turn unit off and wait for 15 minutes  temperature was high and has before restarting  Check if any object  shutdown has blocked the air flow of the unit  E    Unit has sensed input voltage is low Recharge battery as unit will shutdown  and warning occurs shortly    E06 Unit has sensed load connected is Reduce load  close to overload shutdown limit   Not applicable for 38210  38215        Unit has sensed internal Reduce load and check if any ventilation       temperature is high and is close to of the unit is blocked    thermal shutdown limit       AC Load on Power Inverter   Although the Power Inverter can provide high surge power up to two times the rated output power   some appliances may still trigger on the inverter protection system  A higher power inverter is  required for those appliances    For 38210  38215 modified sinewave inverter  some appliances like speed contr
15. ufacturer will not be responsible for any amount of damage in excess of the retail purchase  price of the unit under any circumstances  Incidental and consequential damages are specifically  excluded from coverage under this warranty    This unit is not intended for commercial use  This warranty does not apply to damage to units from  misuse or incorrect installation connection  Misuse includes wiring or connecting to improper  polarity power sources     If you are experiencing any problems with your unit  please contact our customer service  department at info naturepowerproducts com or Phone 1 800 588 0590 before returning  product to retail store  After speaking to a customer service representative  if products are deemed  non working or malfunctioning  the product may be returned to the purchasing store    If such a unit is returned less than one year from the purchase date  manufacturer will repair the  unit or  at its discretion  replace it  free of charge  If the unit is repaired  new or reconditioned  replacement parts may be used  at manufacturer   s discretion  A unit may be replaced with a new or  reconditioned unit of the same or comparable design  The repaired or replaced unit will then be  warranted under these terms for the remainder of the warranty period  The customer is responsible  for the shipping charges on all returned items        Limitations    This warranty does not cover accessories  such as adapters and batteries  damage or defects  result from norm
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
TextWrangler 4.0 User Manual  Reusable code. A lot ot a    Mini Chiller Service Manual (T1/R22/50Hz)  Mode d`emploi version élève - CPNE    Manual del propietario  Internet Security `Internet Security` is the term used to describe the  ハニカムスクリーン レフィーナ ツインスタイル ドラム式 取扱説明書      Copyright © All rights reserved. 