Home
B-Air CP-1 ETL RED Use and Care Manual
Contents
1. OWNER S MANUAL B AIR BLOWER CUB POWER MODEL 1 INTRODUCTION e OPERATION e SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS e IROUBLESHOOTING READ AND SAVE THESE INSTRUCTIONS INTRODUCTION TO 1 1 YOUR NEW B AIR CUB 1 BLOWER HAS A 1 4 HP EFFICENCY MOTOR WHICH HAS STATE OF THE ART CONSTRUCTION AND SCREENS ON OPEN VENTS FOR SAFETY AND LONG LIFE THE HANDLES ARE DESIGNED FOR EASY CARRYING AND THE UNITS CAN OPERATE IN THREE DIFFERENT POSITIONS OPERATION USE THE CUB POWER BLOWER IS INTENDED TO INFLATE SMALL INFLATABLE STRUCTURES IT IS ALSO SUITABLE FOR A VARIETY OF OTHER APPLICATIONS INCLUDING USING THEM INTERNALLY A CAREFULLY PLACE THE B AIR CUB UNIT ON STABLE FLAT DRY SURFACE KEEPING CHILDREN AWAY B ATTACH AN INFLATABLE TUBE AROUND THE EXHAUST OPENING USING STRAPS OR ANY OTHER FORM OF TIGHTENER C PLUG CORD INTO A GROUNDED GFCI OUTLET ONLY D TURN ON SWITCH AND MAKE SURE IT IS OPERATING CORRECTLY E ALL BLOWERS IN OPERATION MUST BE SUPERVISED AT ALL TIMES STORAGE STORE UNIT INDOORS IN A CLEAN DRY ENVIRONMENT TO ENSURE LONG LIFE SAFETY 1 2 3 4 5 6 7 8 9 10 wa 11 12 13 14 15 16 BLOWER MUST HAVE BACK PRESSURE MEANING IT MUST BE ATTACHED TO AN INFLATABLE OR DUCT TO AVOID ANY DAMAGE TO MOTOR KEEP CHILDREN AWAY FROM UNIT AT ALL TIMES WHILE IN OPERATION AND OR PLUGGED IN DO NO
2. OWERS HOUSING IS COVERED FOR A TERM OF 5 FIVE FULL YEARS FROM THE DATE OF THE ORIGINAL PURCHASE DOES NOT COVER 1 ANY SIGNS OF MISUSE INCLUDING BUT NOT LIMITED TO ROUGH HANDLING ABUSE TAMPERING IMPROPER VOLTAGE USE UNAUTHORIZED MAINTENANCE AND REPAIRS WARNING ALL BLOWERS IN OPERATION MUST BE SUPERVISED AND ATTENDED AT ALL TIMES THE USE OF A 3 PRONG TO 2 PRONG ADAPTER IS PROHIBITED ONLY USE A 2 PRONG TO 2 PRONG ADAPTER CONTACT INTERTEX INC B AIR BLOWERS 1851 TYBURN STREET GLENDALE CA 91204 1 877 800 2247 BAIR FAX 818 242 2430 EMAIL INFO INTERTEXINC COM WEB SITE www b air com SPECIFICATIONS MODEL CP 1 VOLTAGE 115 V 230 V MAX AIR VOLUME 375 CFM 345 CFM AMPS 2 3 A 1 3 A MAX STATIC PRESSURE 2 8 INCH 2 6 INCH WEIGHT NET GR 11 12 LBS 11 12 LBS UNIT SIZE LxWxH 10 5 x 10 x 8 5 INCH 10 5 x 10 x 8 5 INCH WHEEL SPEED RPM 3400 2850 MOTOR 1 4 HP 1 4 HP ATTACHED CORD 18G 6FT 6 FT TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Motor Not Running a Switch is OFF a Turn Switch ON b Check Outlet Change to ungt Another Outlet c Call Factory for new eeu owe oe Switch Replace Cord Scraping Noise From Blower Wheel Out Of Line Replacement Advise Weak Air Flow a Obstructed Vents Inlets a Clean Out Vents Inlets
3. T PUT FINGERS OR OTHER OBJECTS IN UNIT WHILE IN OPERATION AND OR PLUGGED IN DO NOT OPERATE IN POOLED WATER TO AVOID ELECTRIC SHOCK MOTOR MUST BE KEPT DRY AT ALL TIMES IF UNIT BECOMES WET THOROUGHLY DRY BEFORE NEXT OPERATION INDOOR USE USE ONLY WITH A GROUNDED PLUG AND OR EXTENSION CORD TO AVOID RISK OF ELECTRICAL SHOCK OR FIRE REMEMBER NEVER TO USE A CORD WITH ANY KIND OF DAMAGE OR WEAR MAKE SURE THE POWER SOURCE IS SUFFICIENT TO MEET THE REQUIREMENTS OF THE BLOWER KEEP AIR INTAKES CLEAR AT ALL TIMES TO AVOID CLOGGING OR BLOCKING IN ORDER TO PREVENT OVERHEATING THE UNIT BLOCKING THE AIR INTAKES COULD RESULT IN A FIRE OR ELECTRICAL HAZARDS DO NOT REMOVE ANY SCREENS OR SAFETY GUARDS FROM THIS UNIT TO PREVENT INJURY TO PERSONS AND TO AVOID OBJECTS FROM COMING IN CONTACT WITH THE BLOWER WHEEL UNIT DAMAGE IN THIS MANNER WILL VOID YOUR WARRANTY DO NOT OPERATE UNIT CLOSE TO ANY DANGEROUS AREAS SUCH AS EXPLOSIVE GASES FLAMMABLES HEATERS AND VENTILATED ENVIORMENTS WHICH MAY RESULT IN EXPLOSIONS OR ELECTRICAL HAZZARDS DO NOT USE ANY FORM OF SPEED CONTROL DEVICE AS DOING SO MAY RISK INJURY OR FIRE ALWAYS PLACE BLOWER ON A SMOOTH AND LEVELED SURFACE FOR SAFE OPERATION DO NOT OPERATE IN STACKED POSITION DO NOT USE UNIT IF DAMAGED BEFORE CLEANING OR SERVICING UNPLUG UNIT ALL BLOWERS IN OPERATION MUST BE SUPERVISED AT ALL TIMES WARRANTY 1 YEAR From Original Purchase date will cover all parts except Cords labor a
4. nd one way shipping costs to your location in the 48 Contiguous states using UPS Ground Service Customer will pay shipping to our warehouse Canada and Non Contiguous States must pay for freight both ways 5 YEAR B Air will cover Housing from date of Original purchase SERVICE IN ORDER TO RECEIVE SERVICE OR REPLACEMENT PARTS UNDER WARRANTY YOU MUST A CALL FOR A RMA Return Merchandise Authorization Number B HAVE PROOF OF PURCHASE C SHIP TO B AIR BLOWERS IFIMMEDIATE SERVICE IS REQUIRED B AIR WILL SHIP REFURBISHED BLOWER IMMEDIATELY TO REPLACE THE ONE REQUIRING SERVICE IF A CREDIT CARD IS PROVIDED AND CHARGED ONCE WE RECEIVE YOUR BLOWER WE WILL CREDIT YOUR CREDIT CARD ACCOUNT e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
Download Pdf Manuals
Related Search
Related Contents
その2(839KB) Leica Manuel de l`utilisateur POWER AMPLIFIERS Einbau- und Bedienungsanleitung お使いの手引き(7.43MB Petite Bibliothèque des Compagnons du Taijiquan Aerocharger.com ロータリーダンパー (手動用) 取扱説明書 Black & Decker TO2050S Use & Care Manual page 1/2 251, rue de Vaugirard 75732 PARIS CEDEX 15 Tél.: 01.49 Copyright © All rights reserved.
Failed to retrieve file