Home
Battic Door Energy Conservation Products Infinity2200 Installation Guide
Contents
1. Ta marack Technologi nc ologies gn l di HONS www tamtech com 320 Main Street Buzzards Bay MA 02532 508 759 4660 800 222 5932 Fax 508 759 6001 The INFINITY PRODUCT MANUAL amp INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit in the manner intended by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting cannot be locked securely fasten a prominent warning device such as a tag to the service panel When cuiting or drilling into wall or ceiling do not damage electrical wiring or other hidden utilities Never place a switch where it can be reached from a tub or shower Do not use this fan over a tub or shower Do not use this fan over cooking appliances CAUTION For General Ventilation Use Only Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors CAUTION This unit has an unguarded impeller Do Not Use in Locations Readily Accessible to People or Animals The Best Location for The Infinity 1 When selecting fan mounting location consider the following a Mounting The Infinity as far as possible from the interior air intake or exhaust points will minimize fan operating
2. noise from being transmitted back through the duct work Insulated flexible type duct work will result in much quieter operation b The Infinity location should allow sufficient access for service 2 Attach fan to the mounting bracket with the nuts and bolts provided The wiring box should be positioned for easy access 3 Using the wood screws provided attach the mounting brackets to a rafter or support beam at the selected location 4 Connect ductwork to the inlet and outlet collars of The Infinity using clamps or duct tape When using insulated duct it is recommended that the inner vinyl core be clamped or taped to the collars and that the vapor barrier surrounding the insulation be duct taped to the housing SPECIFICATIONS Duct Size 4 10 Duct Collar Length 3 with Bead Electrical Requirements 115V 60Hz 3A Total Overall Dimensions 30 W x 17 1 8 H x 9 5D Mounting Flange Dimensions 27 x 1 1 2 Unit Weight 27 Lbs Air Flow each motor 1070 cfm 1 Wg Tamarack Technologies 320 Main Street Buzzards Bay MA 02532 Ph 508 759 4660 Fx 508 759 6001 Electrical Connections DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED MAKE SURE ELECTRICAL SERVICE TO THE FAN IS LOCKED IN OFF POSITION NOTE The Infinity fan motors can be wired individually or as a pair 1 Remove the cover from the junction box 2 Remove the knockout on the junction box that is closest to the source wirin
3. EPT AS SET FORTH ABOVE NO EXPRESS OR IMPLIED WARRANTY IS GIVEN OR AUTHORIZED BY TAMARACK TECHNOLOGIES INC AND ALL OTHER SUCH WARRANTIES ARE EXPRESSLY DISCLAIMED ANY WARRANTY OR MERCHANTABILITY OF FITNESS FOR ANY PARTICULAR PURPOSE SHALL BE LIMITED TO THE WARRANTY HEREUNDER MOREOVER ANY LIABILITY OF TAMARACK TECHNOLOGIES INC FOR THE PRODUCT SHALL BE LIMITED TO THE REPLACEMENT VALUE OF THE PRODUCT IN NO EVENT SHALL TAMARACK TECHNOLOGIES INC BE LIABLE FOR ANY INCIDENTAL DAMAGES OR FOR ANY CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGES IRRESPECTIVE OF THE CAUSE THEREOF OCCURRING EITHER DURING OR AFTER THE WARRANTY PERIOD INCLUDING WITHOUT LIMITATION ANY DAMAGES TO ANY PART OF A BUILDING OR ITS CONTENTS NOTE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES AND SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE PROOF OF PURCHASE REQUIRED Tamarack Technologies 320 Main Street Buzzards Bay MA 02532 Ph 508 759 4660 Fx 508 759 6001
4. g 3 Attach a cable clamp 4 Feed the source electrical wires into the electrical box and tighten the clamp 5 Connect The Infinity fan motor wires to the source wires by twisting each pair together and then installing a wire nut over them 6 Fasten the ground wire from the source electrical wires to the ground screw located in the junction box 7 Replace the cover on the junction box NEUTRAL NEUTRAL 1TSV SUPPLY 115V SUPPLY LINE LINE Single Control Independent Control P N INFPG 1 LIMITED WARRANTY If within the period of three years from the date of purchase The INFINITY the Product is defective or malfunctions in normal home use Tamarack Technologies Inc will repair or replace the Product at its discretion Customer is responsible for shipping charges CONDITIONS EXCLUSIONS AND LIMITATIONS This Warranty is subject to the following conditions exclusions and limitations THIS WARRANTY DOES NOT COVER PROBLEMS RESULTING FROM INSTALLATION OPERATION OR MAINTENANCE THAT HAS BEEN UNDERTAKEN OTHER THAN IN ACCORDANCE WITH THE INSTRUCTIONS THIS WARRANTY DOES NOT COVER PROBLEMS RESULTING FROM DEFECTS IN OR CAUSED BY ASSOCIATED EQUIPMENT FURNACES SOLARIA ETC FROM REPAIRS OR MODIFICATIONS ATTEMPTED BY PERSONS OTHER THAN TAMARACK TECHNOLOGIES INC FROM ABUSE ACCIDENTAL OR SHIPPING DAMAGE OR ACTS OF GOD THIS WARRANTY DOES NOT APPLY TO THE PRODUCT USED OUTSIDE THE UNITED STATES ITS TERRITORIAL POSSESSIONS AND CANADA EXC
Download Pdf Manuals
Related Search
Related Contents
307A Manual(1832 IN) Emerson Process Management OXYMITTER 4000 User's Manual PHOTOMOD Mosaic USER MANUAL Projecta Speedy Crank Sony D-EJ756CK User's Manual Silverstone SDP08 British Telecom Duet 60 Faites confiance au meilleur Draytek Vigor2700 Copyright © All rights reserved.
Failed to retrieve file