1. Aftermarket Completion of sale not for purpose of resale from the manufacturer PATENT INFORMATION This product may be covered by one or more of the following United States patents 8 915 239 8 851 065 8 764 436 8 757 202 8 757 139 8 752 541 8 568 136 8 545 216 8 517 718 8 516 878 8 506 290 8 465 277 8 317 511 8 297 968 8 281 781 8 241 034 8 235 708 8 152 515 8 011 920 7 967 006 7 967 007 7 654 820 7 730 765 7 677 236 7 607 426 7 434 447 2 www sureheat com 200211 01A SAFETY IMPORTANT Read this owner s manual carefully and completely before trying to assemble op erate or service this heater Improper use of this heater can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning Only aqualified installer service agent or local gas supplier may install and service this product WARNING Keep the appli ance area clear and free from combustible materials gasoline andotherflammable vapors and liquids WARNING This appliance can be used with propane or natural gas It is shipped from the factory adjusted for use with propane This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases A DANGER Carbon monoxide poisoning may lead to death CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or n
2. VENT FREE GAS WALL HEATER OWNERS OPERATION AND INSTALLATION MANUAL BLUE FLAME MODELS BWH10NLMC BWHS3ONLTE A WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable va pors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance e Do not touch any electrical switch do not use any phone in your building e Immediately call your gas supplier from a neighbors phone Follow the gas supplier s instructions f you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier A WARNING This appliance is equipped for Natural and Propane gas Field conversionis not permitted other than between natural or propane gases Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 229 5647 8 00 am 4 30 pm EST Monday through Friday TABLE OF CONTENTS Deer cette Specifications Electrical Connection Qualified Installing Agency Electrical Wiring Product Features I
3. Verifique el funcionamiento correcto despu s del servicio Si alguno de los cables originales suministrados con el aparato debe ser rem plazado deber ser remplazado con un cable de al menos 105 C de temperatura Interruptor termostato Switch www sureheat com 55 INSPECCI N DEL CALENTADOR IMPORTANTE El propietario debe revisar frecuentemente los patrones de la Ilama del piloto y de la llama del quemador Patrones de llama incorrectos indican la necesidad de limpieza o servicio de mantenimiento consulte Cuidado y mantenimiento p gina 57 A ADVERTENCIA Solo una persona de servicio capacitada debe repararlo o darle servicio Esto incluye el mantenimiento requerido refacciones o alteraci n de componentes PATR N DE LA LLAMA DEL PILOTO La figura 24 muestra un patr n correcto de la llama del piloto La figura 25 muestra un pa tr n incorrecto de la llama del piloto La llama incorrecta del piloto no toca el termopar Esto ocasionar que el termopar se enfr e Cuando eltermopar se enfr e el calentador se apagar Si el patr n de la llama del piloto es incorrecto como se muestra en la figura 25 apague el calentador consulte C mo ce rrar el suministro de gas al aparato en la p gina 53 o 54 e consulte Soluci n de problemas en la p gina 58 a 62 ADVERTENCIA Sisepresen ta un color amarillo en las pun tas de las llamas
4. Adquiera la v lvula opcional de cierre de equipo certificada con disefio CSA del distribuidor 200211 01A www sureheat com IMPORTANTE instale una v lvula de cierre del equipo en un lugar que sea accesible La v lvula de cierre del equipo es para abrir o cerrar el suministro de gas al aparato Para gas propano LP aplique una peque a cantidad de sellador de tuber a a las roscas NPT macho Esto evitar que el exceso de sellador entre a la tuber a El exceso de se llador en la tuber a puede ocasionar que las v lvulas del calentador se tapen El instalador debe proveer un regulador exter no El regulador externo reducir la presi n del gas entrante Debe reducir la presi n del gas entrante de manera que est entre 11 y 14 de c a Si no reduce la presi n del gas entrante se pueden producir dafios al regulador del calen tador Instale el regulador externo con la ventila apuntando hacia abajo Como se muestra en la figura 16 El apuntar la ventila hacia abajo la protege de la lluvia helada o aguanieve Instale la trampa de sedimentos en la l nea de suministro como se muestra en la figura 15 Sit e la trampa de sedimentos de manera que se pueda tener acceso a ella para limpieza Sit e la trampa de sedimentos donde sea poco probable que los materiales atrapados en ella se congelen La trampa de sedimentos atrapa humedad y contaminantes Esto evita que los sedimentos lleguen a los controles del calentador Si la
5. El piloto ODS est parcial mente tapado 1 Abra la ventana y o la puerta para proporcionar ventilaci n 2 Contacte a su proveedor local de gas 3 Limpie el piloto ODS consulte Cuidado y mantenimiento en la p gina 57 Hay olor a gas incluso cuando la perilla de con trol est en la posici n OFF apagado Fugas de gas Consulte la anotaci n de Advertencia p gina 58 La v lvula de control est defectuosa 1 Localice y repare todas las fugas consulte Revisi n de las conexiones de gas en la p gina 50 2 Remplace la v lvula de con trol Se observa humedad O condensaci n en las ventanas No hay suficiente aire para combusti n o ventilaci n 1 Consulte los requisitos de Aire Para Combusti n y Ventila ci n p gina 39 62 www sureheat com 200211 01A PIEZAS DE REPUESTO Nota use s lo piezas de repuesto originales Esto proteger la cobertura de su garant a para partes remplazadas bajo la garant a PIEZAS CON GARANT A Llame al n mero de servicio al cliente al los n meros de modelo y de serie de su 1 800 229 5647 para solicitar piezas en calentador garant a e la falla del calentador Cuando llame a Servicio al Cliente tenga El tipo de gas utilizado propano PL o gas preparados natural GN su nombre la fecha de compra SU direcci n Por lo general le pediremos que devuelva la pieza a la f
6. IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form too much moisture See Air for Combustion and Ventilation pages 7and 8 CHECK GAS TYPE Be sure your gas supply is right for your heat er Otherwise call dealer where you bought the heater for proper type heater CLEARANCES TO COMBUSTIBLES Carefully follow the instructions below This heater is a freestanding unit designed to be mounted on a wall or set on a base A WARNING Maintain the minimum clearances shown in Figure 4 If you can provide greater clearances from floor ceiling and joining wall CEILING 36 Minimum From Sides of Heater RR MUS NO MM RUN SM 2 Minimum to Top Surface of Carpeting Tile or Other Combustible Material FLOOR Figure 4 Mounting Clearances as Viewed From Front of Heater www sureheat com 9 INSTALLATION LOCATING HEATER This heater is designed to be mounted on a wall For convenience and efficiency install heater 1 Where there is easy access for operation inspection and service 2 In the coldest part of room FASTENING HEATER TO WALL Mounting Bracket The mounting bracket is located on back panel of heater see Figure 5 It has been taped there for shipping Remove mounting bracket from back panel Mounting Bracket Figure 5 Mounting Bracket Loca
7. V lvula de cierre 15 3 del equipo 2 29 Figure 19 Propano LP suministro de gas www sureheat com 51 FUNCIONAMIENTO ADVERTENCIA No seguir estas instrucciones al pie de la letra puede resultar en incen dio o explosi n que produzcan danos a la propiedad lesiones f sicas o la muerte A 1 2 52 Este aparato tiene un piloto que se debe encender manualmente Cuando encienda el piloto siga estas instruc ciones al pie de la letra ANTES DE ENCENDERLO compruebe que alrededor del aparato no hay olor a gas Aseg rese de oler tambi n cerca del suelo ya que algunos gases son m s pesados que el aire y se asientan cerca del suelo QU HACER SI PERCIBE OLOR A GAS No intente encender ning n aparato No toque ning n interruptor el ctrico no use ning n tel fono en el edificio POR SU SEGURIDAD LEA ESTO ANTES DE ENCENDER EL CALENTADOR NEK Llame inmediatamente a su dor de gas desde el tel fono de alg n vecino Siga las instrucciones del proveedor de gas Si no puede localizar al proveedor de gas llame al departamento de bomberos Utilice nicamente la mano para pre sionar o girar la perilla de control de gas Nunca utilice herramientas Si no puede presionar o girar la perilla ma nualmente no intente repararla llame a un t cnico de servicio capacitado Forzarla o tratar de repararla pueden producir un incendio o una ex
8. DO NOT RETURN THIS PRODUCT TO THE PLACE OF PURCHASE If the appliance does not operate properly first thoroughly carry out the instructions provided with the unit to ensure that the appliance is installed correctly and check the troubleshooting section in the use and care manual We recommend you return the warranty registration card so that you can be contacted when any ques tions of safety arise that could affect you The return of the warranty registration card is not a condition for warranty coverage Because of continuing product improvement these specifications are subject to change without notice If you have other questions or need replacement parts contact our Customer Service Hotline at 800 229 5647 or visit our website at www sureheat com SHM International Corp 3140 Moon Station Road Kennesaw GA 30144 200211 01 Rev A 04 15 _ReddyHeater lt CALENTADOR DE GAS DE PARED SIN VENTILAS MANUAL DE FUNCIONAMIENTO E INSTALACION DEL PROPIETARIO LLAMA AZUL MODELOS BWH10NLMC BWHS3ONLTE A ADVERTENCIA Este aparato est equipado para funcionar con gas natural y propano No se permite convertir m s que a gas natural o gas propano ADVERTENCIA si la informaci n contenida en este manual no se sigue al pie de la letra se puede producir un incendio o una explosi n que podr a ocasionar da os a la propiedad lesiones personales o la p rdida de la vida No guarde ni utilice gasolina u otr
9. Note Both HIGH and LOW are locked positions You must press in control knob before turning it from these positions OFF PILOT IGN HIGH LOW Ignitor Button Control Knob Figure 21 Control Knob in the OFF Position www sureheat com 19 OPERATION KN TO TURN OFF GAS TO APPLIANCE Shutting Off Heater Shutting off burner only Turn control knob clockwise to the pilot stays lit OFF position Turn control knob clockwise w to the Turn off all electric power to the appliance PILOT IGN position if service is to be performed LK ____ ALL MODELS 20 Remove lower rontipanel T Natural Gas Ignitor Thermocouple Follow steps 1 through 5 under Lighting Burner Electrode Instructions page 18 or 19 With control knob pressed in strike match Hold match to pilot until pilot lights Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob Follow step 8 under Lighting Instructions page 18 or 19 Replace lower front panel Propane LP Gas Burner Pilot Air Inlet Hole Pilot Air Inlet Hole Figure 22 Pilot Assembly www sureheat com 200211 01A ELECTRICAL CONNECTION FOR HEATERS EQUIPPED WITH A BLOWER Do not use this heater if any part of it has been under water Immediately call a qualified ser vice technician to inspect the heater and replace any part of the electrical system which has been under water GRO
10. Siempre especificar n meros de serie y modelo cuando se comunigue con servicio al cliente Nos reservamos el derecho a modificar estas especificaciones en cualguier momento sin previo aviso La nica garant a aplicable es nuestro est ndar escrito de garant a No hacemos ninguna otra garant a expresa o impl cita GARANT A LIMITADA SHM International Corp garantiza que los componentes de este aparato no presentan defectos en los materiales y la fabricaci n durante un 1 afio a contar de la fecha de compra SHM International Corp a su opci n reparar o reemplazar este producto o cualquiera de sus componentes que se encuentren defectuosos durante el per odo de la garant a El producto o componente ser reemplazado por otro nuevo Si el producto ya no est disponible se reemplazar por uno similar del mismo valor Esta garant a no incluye costos de transporte ni de env o de ning n tipo sta es su garant a exclusiva Esta garant a es v lida para el comprador original a contar de la fecha de compra inicial y no es transferi ble Conserve el recibo de venta original Se requiere un comprobante de la compra para obtener piezas bajo la garant a Esta garant a no cubre el desgaste normal de piezas como rasgufios y muescas de los componentes o dafios ocasionados por cualquiera de los siguientes motivos Uso negligente o mal uso del producto incluida la exposici n del producto a sustancias qu micas o productos de limpi
11. brica PIEZAS SIN GARANT A Llame al n mero de servicio al cliente al Cuando llame a Servicio al Cliente tenga 1 800 229 5647 para solicitar piezas que no preparados est n bajo garant a los n meros de modelo y de serie de su calentador el n mero de la pieza de repuesto ACCESORIOS Adquiera estos accesorios con su distribuidor local Si no pueden proporcionarle estos acce Sorios comun quese SHM International Corp al 1 800 229 5647 para obtener informaci n V LVULA DE INTERRUPCI N DE EQUIPOS RMH 120 00088 Para todos los modelos V lvula de interrupci n de equipos con 1 8 Llave de paso del TNP CONSEJOS PARA SERVICIO Cuando la presi n del gas de entrada sea muy baja e El piloto no permanecer encendido El quemador tendr un retraso durante el encendido Elcalentador no producir el calor especificado El suministro de gas propano LP puede ser bajo Posiblemente piense que la presi n del gas es muy baja Si es as comun quese con el proveedor local de gas SERVICIO T CNICO Es posible que tenga preguntas adicionales sobre la instalaci n el funcionamiento o la soluci n de problemas De ser as p ngase en contacto con SHM International Corp al 1 800 229 5647 Al llamar tenga a la mano los numeros de modelo y serie de su calentador 200211 01A www sureheat com 63 PIEZAS MODELO BWH10NLMC www sureheat com 200211 01A PIEZAS
12. lvula de cierre del equipo 200211 01A INSTALACI N 200211 01A Comprobaci n de la presi n de las conexiones de gas del calentador Abra la v lvula de cierre del equipo con sulte la figura 17 p gina 50 Si usa gas natural abra la v lvula principal de gas ubicada en el medidor de gas o cerca de ste Si usa propano o gas LP abra la v lvula de suministro de propano o gas LP Compruebe que la perilla de control del calentador est en la posici n OFF apa gado Revise todas las uniones entre la v lvula de cierre del equipo y v lvula de control V lvula de gas Medidor de gas IN 7 Or Sa V lvula de cierre del equipo Figura 18 Suministro de gas natural consulte la figura 18 o 19 Aplique en todas las uniones alg n l quido para detectar fugas que no sea corrosivo La formaci n de burbujas indicar una fuga 5 Repare todas las fugas inmediatamente 6 Encienda el calentador consulte Funcio namiento p gina 52 Revise el resto de las uniones internas para ver si hay fugas 7 Apague el calentador consulte C mo cerrar el suministro de gas al aparato p gina 53 o 54 8 Vuelva a colocar el panel anterior V lvula de gas Tanque de suministro de propano o gas LP YI z SEIE EEE Sos o 1000000008 SS SS PORO A SKKKKE RR
13. n de la manecillas del reloj hasta la posici n OFF apagado C mo apagar el quemador s lo permanece encendido Gire la perilla de control en direcci n de la manecillas del reloj hasta la posici n PILOT piloto MODELO BWH10NLMC ME INSTRUCCIONES DE ENCENDIDO ME 1 ALTO Lea la informaci n seguridad antes mencionada p gina 52 2 Comprobar que el suministro de gas para calefacci n 3 Empujar la perilla de control y a su vez en el sentido de las agujas del reloj 771 hacia la posici n OFF 200211 01A 4 Espere cinco minutos a que se disipe el gas Luego compruebe que no huela a gas incluso cerca del piso Si percibe olor a gas DET NGASE Realice el inciso B de la informaci n de seguridad provista a partir de la p gina 52 Si no percibe olor a gas contin e con el siguiente paso www sureheat com 53 FUNCIONAMIENTO 5 Gire la perilla de control en el sentido contrario a las agujas del reloj N hacia la posici n PILOT IGN PILOTO Presione la perilla de control durante cinco 5 segundos Nota la primera vez que haga funcionar el calentador despu s de conectar el sumi nistro de gas la perilla de control se debe presionar durante aproximadamente trein ta 30 segundos Esto permitir purgar el aire del sistema de suministro de gas 6 Con la perilla de control presionado presione y suelte el bot n arrancador Esto iluminar a piloto Si es necesario mantener bot n a
14. o bien abriendo la v lvula principal de gas que se localiza en el medidor de gas natural o cerca de ste o bien usando aire comprimido Revise todas las uniones del sistema de tuber a de suministro de gas Aplique en todas las uniones alg n l quido de detec ci n de fugas que no sea corrosivo La formaci n de burbujas indicar una fuga Repare todas las fugas inmediatamente Vuelva a conectar el calentador y la v lvula de cierre del equipo al suministro de gas Revise las conexiones que se volvieron a conectar en caso de fugas Presiones de prueba iguales o menores a 3 5 kPa 1 2 PSI Cierre la v lvula de cierre del equipo consulte la figura 17 2 Regule la presi n del sistema de tuber a de suministro ya sea abriendo la v lvula del tanque de suministro de gas propano LP en caso que utilice este tipo de gas o bien abriendo la v lvula principal de gas que se localiza en el medidor de gas natural o cerca de ste o bien usando aire comprimido 3 Revise todas las uniones desde el medi dor de gas tanto para suministro de gas natural o propano LP hasta la v lvula de 50 4 www sureheat com cierre del equipo consulte la figura 18 o 19 p gina 51 Aplique en todas las uniones alg n l quido de detecci n de fugas que no sea corrosivo La formaci n de burbujas indicar una fuga Repare todas las fugas inmediatamente V lvula de Abierta cierre del equipo Cerrada Figura 17 V
15. presion del todo al pulsar el bot n de encendido Qued aire en las l neas de gas nueva instalaci n o interrupci n gas reciente El piloto ODS est tapado La presi n de gas es in adecuada o el regulador de entrada de gas est da ado La perilla de control no est en la posici n PILOTO Se agot el suministro de gas gas propano LP ni camente Abra el suministro de gas o la v lvula de cierre del equipo Presione la perilla de control del todo al pulsar el bot n de encendido Mantenga presionada la perilla de control Repita el encendido hasta que se haya eliminado el aire Limpie el piloto ODS consulte Cuidado y mantenimiento en la p gina 57 o cambie el ensamble del piloto ODS Revise la presi n de entrada de gas o remplace el regulador de entrada de gas Gire la perilla de control a la posici n PILOTO Comun quese con la compa a local de gas propano LP 200211 01A www sureheat com 59 SOLUCI N DE PROBLEMAS Problema Causa Posible Acci n correctiva El piloto ODS en ciende pero la Ilama se extingue cuando la perilla de control se suelta La perilla de control no est presionada completamente La perilla de control no se presion durante el tiempo suficiente La v lvula de cierre del equipo no est totalmente abierta La conexi n del termopar est
16. 17 OPERATION MI FOR YOUR SAFETY READ BEFORE LIGHTING i WARNING If you do not fol lowthese instructions exactly a fireorexplosion may result caus ing property damage personal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water MODEL BWH30NLTE ee LIGHTING INSTRUCTIONS 1 STOP Read the safety information above 2 Make sure equipment shutoff valve is fully open 3 T
17. 25 Incorrect Pilot Flame Pattern BURNER FLAME PATTERN Figure 26 shows a correct burner flame pat tern Figure 27 shows an incorrect burner flame pattern The incorrect burner flame pattern shows yellow tipping of the flame It also shows the flame higher than 1 2 the heat shield height LAI Fics Figure 26 Correct Burner Flame Pattern 22 www sureheat com If burner flame pattern is incorrect as shown in Figure 27 turn heater off see To Turn Off Gas to Ap pliance page 19 or 20 see Troubleshooting pages 24 through 27 m __ ANANAGA ANAA Aaa QA Tipping AiG AMAA E o Height Figure 27 Incorrect Burner Flame Pattern 200211 01A CARE AND MAINTENANCE WARNING Turn off heater and let cool before servicing A CAUTION You must keep control areas burner and circulating air passageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a qualified service techni cian Heater may need more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc A WARNING Failure to keep the primary air opening s of the burner s clean may result in sooting and property damage ODS PILOT AND BURNER Use a vacuum cleaner pressurized air or a small soft bristled brush to clean BURNER PILOT AIR INLET The primary air inlet hole allows the proper amount of air to mix wit
18. 9101 200211 01A State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts the gas cock must be a T handle type The State of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length www sureheat com 5 PREPARING FOR INSTALLATION Before beginning assembly or operation of the product make sure all parts are present Com pare parts with package contents list If any part is missing or damaged do not attempt to assemble install or operate the product Con tact customer service for replacement parts Ignitor Control Knob Button Grill Burner Heater Cabinet Figure 1 Vent Free Gas Heater UNPACKING 1 Remove heater from carton 2 Remove all protective packaging applied to heater for shipping 3 Checkheater for any shipping damage If heater is damaged promptly inform dealer where you bought heater WATER VAPOR A BY PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by product of gas combus tion An unvented room heater produces ap proximately one 1 ounce 30 mL of water for every 1 000 BTUs 0 3 KWs of gas input per hour Unvented room heaters are recommended as supplemental heat a room rather
19. BWH3ONLTE www sureheat com 200211 01A PARTS MODEL BWH3ONLTE This list contains replaceable parts for your heater When ordering replacement parts follow the instructions listed under Replacement Parts of this manual ITEM PART DESCRIPTION QTY 1 Cabinet Assembly 1 2 Reflector Unit 1 3 ML087 01 Upper Glass Retainer 1 4 ML 086 01 Glass 1 5 ML088 01 Lower Glass Retainer 1 6 sil Middle Panel 1 if MB09051 Lower Front Panel Assembly 1 8 MB29001 Grill Guard 1 9 MB060 01 Mounting Bracket 1 10 RVD88 MAB 4 9 Pressure Regulator Assembly 1 11 ML083 04 Ignitor Assembly 1 12 STL1001 Thermostat Valve Assembly 1 18 Burner Assembly 1 14 NDDO310A 800 P ODS Pilot 1 15 PFO6 YJLF BMB Fan Accessory 1 16 PFO9B Base Assembly 1 PARTS AVAILABLE NOT SHOWN MB28001 Hardware Package 1 ML065 01 Thermostat Sensing Bulb Clip 1 160960 01 Inlet Cover Assembly 1 160960 03 Valve Fitting Assembly 1 ML073 01 Ignitor Cable 1 ML073 05 Ignitor Cable 1 Not a field replaceable part REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Call Customer Service toll free at 1 800 229 5647 to order parts under warranty When calling Customer Service or your dealer have ready Your name Your address Model and serial number o
20. Coloque la punta Vista lateral del tornillo en la abertura del anclaje de pared o del orificio que perfor 9 Apriete los tornillos hasta que el calenta dor est asegurado firmemente a la pared No los apriete demasiado Nota no vuelva a colocar el panel ante rior en este momento Coloque el panel anterior despu s de hacer las conexiones de gas y de revisar si hay fugas Pd Vista frontal Calentador om Figura 11 Instalaci n de los tornillos de montaje inferiores INSTALACI N DE LAS PATAS BASE Si est equipado Antes de instalar el calentador a la base asegurese de tener los siguientes art culos 2 patas base 4 tornillos para l mina de metal Procedimiento de instalaci n 1 Coloque el respaldo del calentador sobre una mesa con su parte inferior proyect n dose fuera del borde de la mesa 2 Coloque las patas base en el calentador con los tornillos para l mina de metal Y Patas Base Tornillo para lamina de metal Figura 12 Instalaci n de las patas base 200211 01A www sureheat com 45 INSTALACI N SELECCI N DE GAS Este aparato viene ajustado de f brica para gas propano LP No se requieren cambios para la conexi n a propano LP S lo un instalador o t cnico de servicio calificado puede realizar la selecci n de gas y la conexi n al suministro de gas PRECAUCI N Dos instala ciones de l neas de gas almismo tiempo est n
21. If you are using natural gas and the pilot will not light see Troubleshooting page 24 200211 01A INSTALLATION CONNECTING TO GAS SUPPLY A WARNING A qualified ser vice technician must connect heater to gas supply Follow all local codes WARNING This appliance requires a 3 8 NPT National Pipe Thread inlet connection to the pressure regulator WARNING For natural gas Never connect heater to private non utility gas wells This gas iscommonly known as wellhead gas WARNING Do not over tighten gas connections A CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to heater If pipe is too small undue loss of pressure will occur A CAUTION For propane LP gas never connect heater directly to the gas supply This heater requires an external regulator not supplied Install the external regulator between the heater and gas supply Gas supplier provides external regu lator for natural gas The installer provides the external regulator for propane LP gas A CAUTION For natural gas check your gas line pressure before connecting heater to gas line Gas line pressure must be no greater than 9 of water If gas line pressure is higher heater regulator damage could occur A CAUTION Avoid damage to regulator Hol
22. Ubicaci n de abrazadera de montaje Figura 6 Desmontaje del panel anterior del calentador 42 www sureheat com 200211 01A INSTALACI N M todos para fijar el soporte de montaje a la pared Use nicamente el ltimo orificio de cada extremo del soporte de montaje para fijarlo a la pared Fije el soporte de montaje a la pared mediante una de las dos maneras siguientes Fijaci n a viga de pared este m todo pro porciona la sujeci n m s firme Inserte los tornillos de montaje en el soporte de montaje y en las vigas de pared Fijaci n a anclajes de pared este m todo le permite fijar el soporte de montaje en pa redes huecas las reas de la pared que se encuentran entre los maderos o en paredes s lidas de concreto o mamposter a Decida cu l m todo se ajusta mejor a sus necesidades Cualquiera de los dos m to dos proporcionar un apoyo seguro para el Soporte de montaje C mo marcar las ubicaciones de los tornillos 1 Fije el soporte de montaje a la pared con cinta en el lugar donde estar situado Aseg rese de que el soporte de montaje est nivelado Ay ADVERTENCIA mantenga las distancias m nimas que se muestran en la figura 4 p gina 42 Si puede proporcione dis tancias m nimas mayores con respecto al piso y la pared de uni n 2 Marque la ubicaci n de los tornillos en la pared consulte la figura 7 Nota Marque nicamente el ltimo orificio de cada extremo del soporte d
23. comprimido a una presi n no mayor de 30 PSI Es posible que la tienda local de equipo de c mputo ferreter a o de mejoras al hogar tengan aire comprimido en latas Si utiliza aire comprimido en lata siga las instrucciones que aparecen en la misma Si no sigue las instrucciones escritas en la lata puede el conjunto del piloto 1 Apague la unidad incluyendo el piloto Deje que la unidad se enfr e durante por lo menos treinta minutos 2 Inspeccione el piloto del quemador en busca de polvo y tierra 3 Haga pasar aire a trav s de los puertos o ranuras y los orificios del quemador 4 Nuncainserte objetos en el tubo del piloto Limpie tambi n el conjunto del piloto Una punta amarilla en la llama del piloto indica la presencia de polvo y suciedad en el conjunto del mismo Hay un peque o orificio de entrada de aire al piloto a aproximadamente 5 cm 2 de donde sale la llama del piloto consulte la figura 28 Con la unidad apagada introduzca aire suavemente a trav s de la entrada de aire Si no cuenta con aire comprimido puede soplar a trav s de una pajilla o popote Electrodo del Quemador de encendedor Termopar gas natural P Quemador de Gas Propano LP Orificio de entrada de aire al piloto P Orificio de entrada de aire al piloto Figura 28 Orificio de entrada de aire al piloto GABINETE Conductos de aire Use aire a presi n para la limpieza Exterior Utilice un humedecid
24. conexi n para medidor de prueba uni n de terminal con conexi n a tierra trampa de sedimentos uni n T llave para tuber a manguera flexible para gas revise los c digos locales Una v lvula de cierre de equipo con disefio certificado por la CSA con rosca tipo NPT de 1 8 es una alternativa aceptable como conexi n para el medidor de prueba La v lvula opcional de cierre de equipo con disefio certificado por la CSA la puede adquirir con su distribuidor Di metros usuales de tuber a de entrada Utilice tuber as de hierro negro de 3 8 o m s grandes La instalaci n debe incluir la v lvula de cierre del equipo la uni n y el tap n con rosca NPT de 1 8 Situe el conector con rosca NPT a su alcance para realizar la conexi n del medidor de prueba El conector tipo NPT se debe conectar en direcci n del suministro desde el calentador consulte la figura 15 Uni n terminal con E conexi n a tierra RO Tanque de Regulador externo 2 ini con la ventila 2 tipo NPT suministro tando haci 2 Vua 299 Pepsi En 188 Uni n T edel ogasLP abajo 3 Buje equipo E reductor a E 1 8 tipo Gas natural 5 NPT Del medidor de o gas presi n de 5 Tap n con 7 a 9 c a rosca de Propano o S 1 8 tipo NPT gt gas LP o T Uni n Del regulador externo presi n de Trampa de _ Tubo de tuber a M n 11 a 14 de c a sedimentos Tap n 7 6 cm 3 Figura 15 Conexi n de gas
25. el calentador puede producir niveles elevados de mon xido de carbono Si el patr n dela flama del quemador muestra un color amarillo en las puntas siga las instrucciones AVISO no confunda las llamas anaranjadas con el color amarillo en las puntas El polvo y otras part culas pequefias se introducen al calentador y al quemarse producen breves manchas de llamas anaranjadas Figura 24 Patr n correcto de la llama del piloto Figura 25 Patr n incorrecto de la llama del piloto PATR N DE LA LLAMA DEL CALENTADOR En la figura 26 se muestra el patr n correcto de la flama del quemador En la figura 27 se muestra un patr n incorrecto de la flama del quemador El patr n incorrecto de la llama del quemador produce las puntas amarillas de las llamas Tambi n muestra llamas m s altas que la mitad de la altura del panel de vidrio Si el patr n de la llama del quemador es incorrecto como se muestra en la figura 27 apague el calentador consulte C mo ce rrar el suministro de gas al aparato en la p gina 53 o 54 e consulte Soluci n de problemas en la p gina 58 a 62 56 www sureheat com NINI 71 2 la altura del y vidrio Figura 26 Patr n correcto de la llama del quemador Puntas A amarillas 1 2 de la altura Y vidrio Figura 27 Patr n incorrecto de
26. el regulador externo para el gas propano LP ADVERTENCIA No sobre apriete las conexiones de gas A PRECAUCI N Utilice nica mente tuber a nueva de hierro negro o de acero En algunas reas se puede utilizartuber a de cobre con interior galvanizado Consulte los c digos locales Use tuber a de 1 2 de di metro interior o mayor para que el volumen de gas al calentador sea el adecuado Si la tuber a es demasiado angosta se pro ducir una p rdida indebida de presi n PRECAUCI N Revise la presi n de la l nea de gas natural antes de conectar el calentador a la l nea La presi n de la l nea de gas no debe ser superior a22 9 cm 9 dec a Sila presi n de la l nea de gas es superior podr a danarse el regulador del calentador PRECAUCI N Evite da ar el regulador Sostenga el regulador de gas con una llave cuando lo conecte a la tuber a de gas y o a las conexiones ADVERTENCIA Use sellador para tuber a que sea resistente al gas Propano LP o Gas Natural 48 www sureheat com 200211 01A INSTALACI N Antes de instalar el calentador aseg rese de tener los elementos gue se indican a continuaci n regulador externo para gas propano LP proporcionado por el t cnico capacitado que realiza la instalaci n tuber a consulte los c digos locales sellador resistente al gas natural y gas propano LP v lvula de cierre del equipo
27. from Outdoors 200211 01A INSTALLATION NOTICE This heateris intended for use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your pri mary heat source If you have a central heating system you may run systems circulating blower while using heater This will help circulate the heat throughout the house In the event of a power outage you can use this heater as your primary heat source CAUTION When installing heater in a home garage heater pilot and burner must be at least 18 above floor locate heater where moving vehicle will not hit it A WARNING A qualified ser vice person must install heater Follow all local codes WARNING Never install the heater in a bedroom or bathroom over 10 000 Btu hr notallowed in bedroom or bathroom Check local codes in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 36 from the front top or sides of the heater in high traffic areas in windy or drafty areas 200211 01A CAUTION This heater cre ates warm air currents These currents move heat to wall sur faces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as to bacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may cause walls to discolor
28. in person or through a representative is engaged in and is responsible for a Installing testing or replacing gas piping or b Connecting installing testing repairing or servicing equipment that is experienced in such work that is familiar with all precau tions required and that has complied with all the requirement of the authority having jurisdiction PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Deple tion Sensing ODS safety shutoff system The ODS pilot shuts off the heater if there is not enough fresh air 2 GAS OPTIONS AVAILABLE Your heater is equipped to operate on either Propane LP or Natural gas The heater is shipped from the factory ready for connect ing to Propane LP The heater can easily be changed to Natural gas by having your quali fied installer follow the instructions on page 13 and the markings on the heater THERMOSTATIC CONTROL Thermostat Model BWH3ONLTE Only These heaters have a control valve with a thermostat sensing bulb This results in the greatest heater comfort and may result in lower gas bills LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of The National Fuel Gas Code ANSI Z223 1 NFPA 54 Available from American National Standards Institute Inc 1430 Broadway New York NY 10018 National Fire Protection Association Inc 1 Batterymarch Park Quincy MA 02269
29. in place with one hand With other hand insert mounting screw though bottom mounting hole and spacer Place tip of screw in opening of wall anchor or drilled hole 9 Tighten both screws until heater is firmly secured to wall Do not over tighten Or 4s c Note Do not replace front panel at this time Replace front panel after making gas connec tions and checking for leaks LEER Ce OO XX XX B SS OK 4 Front View Wall Heater omm Spacer Side View Figure 11 Installing Bottom Mounting Screws INSTALLATION OF BASE STAND If Equipped Before installing heater to base please make sure you have a hardware packet that con tains the following items 2 Base Feet 4 Sheet Metal Screws 1 Carefully lay heater on its back on a table with the bottom of the heater extending outside the table edge 2 Attach base feet to heater using sheet metal screws 12 www sureheat com AM em Sheet Metal Screws db 4 sc oe Base Feet Figure 12 Installing Base Feet 200211 01A INSTALLATION GAS SELECTION This appliance is factory preset for propane LP gas No changes are required for connecting to propane LP Only a gualifiedinstaller or service technician can perform gas selec tionand connecting to gas supply CAUTION Two gas line in stallations at the same time are prohibited AX CAUTION To avoid gas le
30. la llama del quemador 200211 01A CUIDADO Y MANTENIMIENTO de darle mantenimiento A ADVERTENCIA Apague el calentador y deje que se enfr e antes de pelo de mascotas etc A PRECAUCION Debe mantener limpias las areas de control el quemador y las vias de circulaci n de aire del calentador Inspec cione estas reas del calentador antes de cada uso Haga que una persona de servicio calificada inspeccione el calentador una vez al afio Es posible que el calentador requiera de limpieza m s frecuente a causa del exceso de pelusa proveniente de alfombras de camas ADVERTENCIA No mantenerlimpias las entradas principales de aire puede facilitar la producci n de holl n y producir a la propiedad PILOTO CON ODS Y QUEMADOR Utilice una aspiradora aire a presi n o un cepillo de cerdas suaves para la limpieza ENTRADA DE AIRE AL PILOTO DEL QUEMADOR The primary air inlet hole allows the proper amount of air to mix with the gas This pro vides a clean burning flame Keep this hole clear of dust dirt and lint Clean this air inlet hole prior to each heating season A blocked air hole will create soot We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person Tambi n se recomienda que mantenga el conjunto de tubo y piloto del calentador limpio y libre de polvo y suciedad Para limpiar estas piezas se recomienda usar aire
31. pressed in for 30 seconds after lighting pilot After 30 seconds release control knob If control knob does not pop up when released contact a qualified service technician or gas supplier for repairs Cr Ignitor Button Control Knob Figure 20 Control Knob in the OFF Position 200211 01A OPERATION Note If pilot goes out repeat steps 3 through 7 This heater has a safety inter lock system Wait one 1 minute before lighting pilot again 8 Turn control knob counterclockwise to desired heating level The main burner should light Set control knob to any heat level between 1 and 5 A CAUTION Do not try to ad just heating levels by using the equipment shutoff valve Ee THERMOSTAT CONTROL OPERATION I NN The thermostatic control used on this model differs from standard thermostats You set standard thermostats to a specific tempera ture such as 72 degrees The thermostat used on this heater senses the room tem perature At times the room may exceed the set temperature If so the burner will shut off The burner will cycle back on when room temperature drops below the set temperature The control knob can be set to any comfort level between HIGH 5 and LOW 1 Note The thermostat sensing bulb reacts to the temperature depending on housing construction Eee TO TURN OFF GAS TO APPLIANCE IK Shutting Off Heater Turn control knob clockwise w to the OFF position Shutting Off
32. prohibidos PRECAUCI N Para evitar la fuga de gas para el gas no se utiliza en la entrada del regula dor un instalador o t cnico de servicio calificado debe utilizar el enchufe suministrado Ustednotar un c digo de colores mbolo en el interior del regula dor Esto es normal Cuando se inserta el accesorio de conexi n deentraday apretada este mbo lo se ech hacia atr s mediante la instalaci n de hacer todos los ajustes para el gas que se sumi nistra NO QUITE EL MBOLO El regulador no funcionar El regulador de entrada es un c digo decolor paralaidentificaci n del tipo de gas correcta El azul es para el propano gas LP y el amarillo es para el gas natural Ajuste suministradas con el producto se encuentra en la bolsa de accesorios N mero de pieza de montaje 160960 02 recto 160960 03 codo 46 www sureheat com Conexi n de gas Figura 13 Parte posterior del calentador Amarilla gas natural mbolo debajo enchufe del metal Azul propano LP gas tapa mbolo debajo de polvo Inserte gas montaje de Insertar gas montaje Gas Natural para Propano LP gas Figura 14 Regulador de Gas PARA EL PROPANO LP INSTALACI N DE GAS AZUL 1 Retire la cubierta de polvo azul Cubierta de NO QUITE polvo azul Azul propano LP gas mbolo Instale Gas Fitting Aqu 200211 01A INSTALACI N Apligue sellador de roscas a las roscas en el
33. s inside any structure Propane LP supply tank s must be placed outdoors If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture Heaters 10 000 Btu Hr or more shall 8 BWH10NLMC Model Only Always run be installed in a bedroom or bathroom heater with control knob at PILOT IGN This heater needs fresh air ventilation to LOW 1 or HIGH 5 locked positions run properly This heater has an Oxygen Never set control knob between locked Depletion Sensing ODS safety shutoff positions Poor combustion and higher system The ODS shuts down the heater levels of carbon monoxide may result if not enough fresh air is available See 9 Do not use heater if any part has been Air for Combustion and Ventilation pages under water Immediately call a qualified 7 and 8 If heater keeps shutting off see service technician to inspect the room Troubleshooting page 24 heater and to replace any part of the Keep all air openings in front and bottom control system and any gas control which of heater clear and free of debris This will has been under water ensure enough air for proper combustion 10 Turn off and unplug heater and let cool If heater shuts off do not relight until you before servicing Only a qualified service have provided fresh outside air If heater person should service and repair heater keeps shutting off have it serviced 11 Operating heater above eleva
34. solid walls do not pop open wings 200211 01A 5 Place mounting bracket onto wall Line up 1 2 last hole on each end of bracket with wall anchors Insert mounting screws through bracket and into wall anchors Tighten screws until mounting bracket is firmly fastened to wall Figure 8 Folding Anchor Nb 5 Figure 9 Popping Open Anchor Wings For Thin Walls Placing Heater On Mounting Bracket Locate two horizontal slots on back panel of heater see Figure 10 Place heater onto mounting bracket Slide horizontal slots onto stand out tabs on mounting bracket Horizontal Slots Mounting Bracket attached to wall Figure 10 Mounting Heater Onto Mounting Bracket www sureheat com 11 INSTALLATION Installing Bottom Mounting Bracket 1 Install bottom bracket to heater bottom with two screws It may be more conve nient to remove heater from wall bracket to attach Place heater on wall mounting bracket Mark screw locations on wall Remove heater from mounting bracket If installing bottom mounting screws into hollow or solid wall install wall anchors Follow steps 1 through 4 under Attaching To Wall Anchor Method page 11 If install ing bottom mounting screw into wall stud drill holes at marked locations using 9 64 drill bit 6 Replace heater onto mounting bracket 7T Place spacers between bottom mounting holes and wall anchor or drilled hole 8 Hold spacer
35. than a primary heat source an entire house In most supplemental heat applications the water vapor does not create a problem In most applications the water vapor enhances the low humidity atmosphere experienced during cold weather 6 www sureheat com The following steps will help ensure that water vapor does not become a problem 1 the heater 15 sized properly for the application including ample combustion air and circulation air 2 If high humidity is experienced a dehu midifier may be used to help lower the water vapor content of the air 3 Do not use an unvented room heater as the primary heat source 200211 01A AIR FOR COMBUSTION AND VENTILATION A WARNING This heater shall notbeinstalledinaconfined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Read the following instructions toinsure properfresh air for this and other fuel burning appliances in your home A WARNING This heater shall not be installed in a room or space unless the required vol ume of indoor combustion air is provided by the method de scribed in the National Fuel Gas Code ANSI Z223 1 NFPA 54 the International Fuel Gas Code or applicable local codes Today s homes are built more energy efficient than ever New materials increased insulation and new construction methods help reduce heat loss in homes Home owners weather strip and caul
36. trampa de sedimentos no se instala o se instala incorrectamente el ca lentador podr a no funcionar correctamente Figura 16 Regulador externo con la ventila apuntando hacia abajo s lo propano y gas LP 49 INSTALACI N REVISI N DE LAS CONEXIONES DE GAS ADVERTENCIA Despu s de instalar el calentador o de darle servicio pruebe todas las conexiones y tubos de gas de la unidad tanto internas como externas en busca de fugas Repare todas las fugas inme diatamente ADVERTENCIA Nunca use una llama al descubierto para verificar si hay fugas Aplique l quido no corrosivo para detectar fugas en todas las uniones La formaci n de burbujas indicar unafuga Repare todas las fugas inmediatamente Pruebas de presi n del sistema de tuber as de suministro de gas Presiones de prueba que exceden 3 5 kPa 1 2 PSI Desconecte el aparato del sistema de tuber a de suministro de gas con la v lvula principal de gas del aparato v lvula de control y con v lvula de cierre del equipo Las presiones que excedan 3 5 kPa 1 2 PSI ocasionar n al regulador del calentador Coloque una tapa en el extremo abierto del tubo de gas donde estaba conectada la v lvula de cierre del equipo Regule la presi n del sistema de tuber a de suministro ya sea abriendo la v lvula del tanque de suministro de gas propano LP en caso que utilice este tipo de gas
37. 00211 01A www sureheat com funcionamiento Usted debe proporcionar aire fresco adecuado para estos aparatos Esto asegurar una adecuada ventilaci n de los aparatos que queman combustible ventilados A ADVERTENCIA Este calen tador no se debe instalar en una habitaci n o espacio a menos queel volumen requerido de aire de combusti n en interiores es proporcionada por el m todo descrito en el C digo Nacio nal de Gas Combustible ANSI Z223 1 NFPA 54 el Fuel Gas Code Internacional o aplicable c digos locales ADVERTENCIA Silazonaen la que la estufa se puede operar no cumple con el volumen re querido de aire de combusti n en interiores combusti n y de ventilaci n ser n facilitados por uno de los m todos descritos en el C digo Nacional de Gas Combustible ANSIZ223 1 NFPA 54 el Fuel Gas Code Internacio nal o con los c digos locales aplicables 39 AIRE PARA COMBUSTI N Y VENTILACI N AIRE PARA VENTILACI N Aire del interior de la construcci n para ventilaci n Este aire fresco viene de un espacio adyacen te no confinado Cuando se ventila mediante un espacio adyacente no confinado debe haber dos aberturas permanentes en la pared gue est entre los dos espacios una abertura 30 4 cm 12 del techo y otra 30 4 cm 12 del piso consulte las opciones 1 y 2 figura 2 Tambi n se puede quitar la puerta de la habitaci n adyacente consulte la opci n 3 figura 2 Consulte el C
38. 0NLTE termostato s lo EI control apaga y enciende el quemador de forma autom tica por ciclos para mantener una temperatura ambiente deseada www sureheat com 37 NORMAS LOCALES Instale y use el calentador con cuidado Siga todas las normas locales Afalta de normas loca les utilice la ltima edici n del C digo Nacional de Gas Combustible ANSI Z223 1 NFPA 54 Disponible en American National Standards Institute Inc 1430 Broadway New York NY 10018 EE UU National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 EE UU Estado de Massachusetts La instalaci n la debe realizar un plomero o un instalador de gas con licencia para ejercer en el esta do de Massachusetts Los vendedores de calentadores com plementarios de interiores a base de gas propano o de gas natural y sin ventilaci n deben proporcionar a cada cliente una copia del 527 CMR 30 al realizar la venta En el estado de Massachusetts la manija del gas debe ser una manija tipo T El es tado de Massachusetts requiere que el co nector flexible no exceda de 3 pies de largo PREPARACI N PARA LA INSTALACI N Antes de ensamblar u operar el producto ase g rese de tener todas las piezas Compare las piezas con la lista del contenido del paquete Si hay piezas da adas o si faltan piezas no intente armar instalar ni usar el producto P ngase en contacto con el servicio al cliente para obtener piezas de repuesto an
39. ACI N M todo de fijaci n a anclajes de pared Para fijar el soporte de montaje en paredes huecas el rea entre las vigas o en paredes s lidas de concreto o mamposter a 1 Perfore orificios en los lugares marcados utilizando una broca de 5 16 Para las paredes s lidas de concreto o mampos ter a perfore a una profundidad de por lo menos 2 5 cm 1 2 Doble el anclaje de pared como se mues tra en la figura 8 3 Inserte el anclaje de pared las alas pri mero en el orificio Golpee suavemente el anclaje para introducirlo en la pared 4 Para paredes delgadas de 1 3 cm 1 2 o menos inserte la llave roja en el anclaje de pared Empuje la llave roja para que abra las alas de anclaje consulte le Fi gura 9 IMPORTANTE no golpee la llave con un martillo Para paredes gruesas de m s de 1 3 cm 1 2 de ancho o paredes s lidas no abra las alas 5 Coloque el soporte de montaje en la pared Alinee el ltimo orificio de cada extremo del soporte con los anclajes de pared 6 Inserte los tornillos de montaje en el so porte y en los anclajes de pared 7T Apriete los tornillos hasta que el soporte de montaje est asegurado firmemente a la pared N Figura 8 C mo doblar el anclaje ls Figura 9 C mo abrir las alas del anclaje para paredes delgadas 44 www sureheat com Colocaci n del calentador en el soporte de montaje Localice las dos ranuras horizontales en el panel post
40. Burner Only pilot stays lit Turn control knob clockwise w to the PILOT position MODEL BWH10NLMC KE LIGHTING INSTRUCTIONS AAN 1 STOP Read the safety information on page 18 2 Check that gas supply to heater is on 3 Pushin gas control knob slightly and turn clockwise to the OFF position 4 Waitfive 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information on page 18 If you do not smell gas go to the next step 5 Pushin gas control knob slightly and turn counterclockwise 47 to PILOT IGN and press for five 5 seconds Note The first time that the heater is oper ated after connecting the gas supply the control knob should be pressed for about thirty 30 seconds This will allow air to bleed from the gas system 6 With control knob pressed in push down and release the ignitor button This will light pilot If needed keep pressing ignitor button until pilot lights 200211 01A 7 Keep control knob pressed for ten 10 seconds after lighting pilot If pilot goes out repeat steps 5 6 and 7 8 To select the desired heating level par tially press down the control knob slightly and rotate counterclockwise Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position Do not operate between locked positions Set control knob to desired heating position
41. CIA DE INSTALACI N CALIFICADA La instalaci n y el remplazo de tuber as de gas de equipos o de accesorios para la utilizaci n de gas y la reparaci n y el mante nimiento de los equipos deben estar a cargo s lo de una agencia calificada El t rmino agencia calificada significa cualquier perso na empresa corporaci n o compa a que en persona o por medio de un representante se dedique a y sea responsable de a Instalar probar o remplazar tuber as de gas o b Conectar instalar probar reparar o reali zar mantenimiento de equipos que tenga experiencia en este tipo de trabajos que est al tanto de todas las precauciones necesarias y que cumpla con todas las exigencias de las autoridades que tienen jurisdicci n CARACTER STICAS DEL PRODUCTO PILOTO DE SEGURIDAD El calentador posee un piloto que cuenta con un sistema de apagado de seguridad por medio de un sensor de agotamiento de ox geno ODS El sensor de agotamiento de ox geno del piloto apaga el calentador si no hay suficiente cantidad de aire fresco 2 OPCIONES DE GAS DISPONIBLES El calentador est dise ado para funcionar con gas propano o con gas natural El calenta 200211 01A dor es enviado de f brica listo para conectar se a gas propano Para cambiarlo f cilmente a gas natural el instalador calificado debe seguir las instrucciones de la p gina 46 y las indicaciones que aparecen en el calentador CONTROL TERMOST TICO Modelos BWH3
42. MODELO BWH10NLMC Esta lista contiene las piezas remplazables utilizadas en el calentador Al hacer un pedido de piezas siga las instrucciones listadas en Piezas de repuesto en la p gina 63 de este manual ART PARTE DESCRIPCI N CANT 1 5 Ensamble de gabinete 1 2 ius Reflector unir 1 3 ML087 03 Retenedor de vidrio superior 1 4 MLO86 03 Vidrio 1 2 ML088 03 Retenedor de vidrio inferior 1 6 ML084 03 Panel central 1 Y MB09003 Bajar el conjunto del panel frontal 1 8 MB29003 Guardia de parrilla 1 9 MB06 02 Abrazadera de montaje 1 10 MLO83 04 Ensamble de arrancador 1 10 E Ensamble de grabadora 1 12 NV2020 1213B Valvula de control 1 13 RVD88 P 4 9 L Ensamble de regulador de presi n 1 14 NDD0310A 600 P ODS Plloto 1 15 PF0910B Ensamble de base 1 16 MB16002A Ensamble de la perilla de control 1 PIEZAS DISPONIBLES NO SE MUESTRAN MB28001 Hardware paquete 1 160960 01 Asamblea cubierta de la entrada 1 160960 03 Asamblea de montaje de la v lvula 1 ML073 02 Cable encendedor 1 ML073 06 Cable encendedor 1 200211 01A No es una pieza que se pueda remplazar en el sitio www sureheat com 65 PIEZAS 66 MODELO BWHS3ONLTE www sureheat com 200211 01A PIEZAS MODELO BWH3ONLTE Esta lista contiene las piezas remplazables utilizadas en el calentador Al hacer un pedido de piezas siga las instrucciones listadas en Piezas
43. SI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts SS SSS SSS Ventilation Grills Ventilation Into Grills Or into Adjoining Remove Room Door into Option 1 Adjoining Room M Option 3 Figure 2 Ventilation Air from Inside Building Note BWH30NLTE Not for use in bedrooms or bathrooms www sureheat com Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Rework worksheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces LEE Ventilated Attic Outlet hir To Attic To Crawl Space Inlet Air Ventilated Crawl Space Inlet Air Figure 3 Ventilation Air
44. UNDING INSTRUCTIONS This heater is for use on 120 volts The cord has a plug as shown at A in Figure 23 An adapter as shown at C is available for con necting three blade grounding type plugs to two slot receptacles The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box The adapter should not be used if a three slot grounded receptacle is available A o A Grounding Means Figure 23 Grounded Electrical Outlet Cover of Grounded Outlet Box Metal Screw ELECTRICAL WIRING Any electrical re wiring of this appliance must be done by a qualified electrician This wiring must be done in accordance with local codes and or in Canada with the current CSA C22 1 Canadian Electrical Code and for US instal lations the National Electrical Code ANSI NFPA NO 70 A WARNING If repairing or replacing any electrical compo nent or wiring the original wire routing color coding and secur ing locations must be followed A CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and danger ous operation 200211 01A WARNING Never attempt to service heater while itis plugged in operating or hot Burns and electrical shock could result Only a qualified service person should service or repair heater Verify proper operation after servicing If a
45. a puede ser a trav s de una caja de un toma corriente correctamente conectado a tierra El adaptador no se debe usar si hay disponible un recept culo de conexi n a tierra de tres ranuras A o Medios de conexi n a tierra Figura 23 Toma de corriente el ctrica con conexi n a tierra Cubierta de la caja de conexi n a tierra Clavija con conexi n a tierra Tornillo de metal CABLEADO EL CTRICO Todo nuevo cableado el ctrico del electro dom stico debe realizarlo un electricista calificado Este cableado se debe realizar de acuerdo con los c digos locales y o en Canad de acuerdo con el C digo de Elec tricidad de Canada CSA C22 1 actual y para las instalaciones en EE UU de acuerdo con el C digo Nacional de Electricidad ANSI NFPA No 70 A ADVERTENCIA Si se repara oremplaza cualquier componen te el ctrico o cableado se deben seguir las rutas originales de los cables los c digos de color y las ubicaciones de seguridad PRECAUCI N Marque todos los cables antes de la desco nexi n cuando se de servicio a los controles Los errores de cableado pueden ocasionar un funcionamiento incorrecto y peligroso 200211 01A ADVERTENCIA Nuncainten te reparar el calentador mientras esta enchufado funcionando o caliente Las quemaduras y descargas el ctricas podrian resultar S lo un t cnico califi cado debe dar servicio o reparar el calentador
46. accesorio de conexi n Mientras presiona gire hacia la derecha el ajuste hasta gue las roscas se acoplan al regulador Despu s de la instala ci n se ha apretado sido parte en el regulador con una llave para completar endurecimiento del accesorio Instale accesorio adicional para conectar al suministro de la casa PARA GAS NATURAL NG INSTALACION AMARILLO Retire la cubierta de polvo azul del regu lador 80 o Cubierta de polvo azul Retire la tapa met lica instalada sobre la entrada del regulador NG Tapa de metal Instale la tapa de metal sobre entrada del regulador LP propano Esto evitar que los residuos fuera del regulador Utilice solamente el tap n su ministrado en el regulador No utilice un fuera el tap n del tubo estante Esto puede da iar el mbolo La tapa del regulador suministrado est disenado de manera que no se acoplar con el tipo de gas utilizado 4 Aplique sellador de roscas a las roscas en el accesorio de conexi n Mientras presiona gire hacia la derecha el ajuste hasta que las roscas se acoplan al regu lador Despu s de la instalaci n se ha apretado sido parte en el regulador con una llave para completar endurecimiento del accesorio Instale accesorio adicional para conectar al suministro de la casa NO use un fuera de la tap n de tubo NPT de 3 8 estante Esto dafiar los mbolos ubicados dentro del regulador NO intente retirar los mbol
47. ador est en funcionamiento Mantenga a ni os y adultos alejados de las superficies calientes para evitar quemaduras o que la ropa se encienda El calentador perma necer caliente durante alg n tiempo despu s de que se ha apagado Permita que la super ficie se enfr e antes de tocarla ADVERTENCIA No coloque ropa ni otros materiales inflama bles sobre el aparato ni cerca del mismo Nunca coloque ning n objeto sobre el calentador 36 No ponga los tanques de suministro de propano o gas LP dentro de ninguna es tructura Sit e los tanques de suministro de propano o gas LP en el exterior Calentadores de 10 000 Btu Hr o m s no se debe instalar en un dormitorio o en un ba o Este calentador necesita ventilaci n con aire fresco del exterior para funcionar correctamente Este calentador tiene un sistema de apagado de seguridad con detecci n de agotamiento de ox geno ODS El ODS apaga el calentador cuan do no hay suficiente aire fresco Consulte Aire para combusti n y ventilaci n en la p ginas 39 y 40 Si el calentador contin a apag ndose consulte Soluci n de proble mas p ginas 58 a 62 Mantenga todas las entradas de aire del frente y fondo del calentador limpias y libres de escombros Esto asegurar aire suficiente para la combusti n 5 10 1 12 Si el calentador se apaga no lo vuelva a encender hasta que se le haya pro porcionado aire fresco del exterior Si el calen
48. ak ageforthe gas notbeing usedat the inlet of regulator a qualified installer or service technician must use supplied cap You will notice a color coded plunger on the inside ofthe regu lator Thisis normal When the in let connection fitting is inserted and tightened this plunger will be pushed back by the fitting making all of the adjustments for the gas being supplied DO NOT REMOVE THE PLUNGER The regulator will not work The inlet regulator 15 color coded for identification of the correct gas type Blue is for propane LP gas and yellow is for natural gas Fitting supplied with the product located in the hardware bag Fitting part number 160960 02 straight 160960 03 elbow 200211 01A Gas Connection Figure 13 Back of Heater Yellow Natural Gas Blue Propane LP Gas Plunger Underneath Plunger Underneath Metal Cap Dust Cover Insert Gas Fitting for Natural Gas Insert Gas Fitting for Propane LP Gas Figure 14 Gas Regulator FOR PROPANE LP GAS INSTALLATION BLUE 1 Remove blue dust cover zs DO NOT REMOVE Blue Propane LP Plunger Install Gas Fitting Here Blue Dust Cover www sureheat com 13 Yellow Natural Gas Plunger INSTALLATION Apply thread sealant to the threads on the connection fitting While pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to com
49. ando correctamente jRespire aire fresco inmediatamente Haga que le den servicio al calentador El mon xido de carbono afecta m s algunas personas que a otras Las m s afectadas son mujeres embarazadas perso nas con enfermedades del coraz n de los pulmones o anemia aquellas bajo la influen cia del alcohol y aquellas a grandes altitudes Gas natural y gas propano LP el gas na tural y gas propano LP son gases inodoros Al gas propano se le agrega un agente con olor El olor le ayuda a detectar las fugas de gas Sin embargo el olor que se a ade al gas puede desvanecerse Es posible que haya gas presente aunque no haya ningun olor A ADVERTENCIA Cualquier cambio a este calentador oa sus controles puede ser peligroso A ADVERTENCIA No utilice ningun tipo de accesorio de soplador accesorio para inter cambio de calor ni ningun otro accesorio que noest aprobado para su uso con este calentador A ADVERTENCIA Supervise cuidadosamente a los ni os pequenos cuando est n en la habitaci n en la que se encuen tra el calentador Ay ADVERTENCIA Aseg rese que la rejilla de resguardo est puesta antes de hacer funcionar el calentador ADVERTENCIA Debido a las altas temperaturas generadas por este aparato ste se debe colocarfuera de las rutas de paso y alejado de muebles y cortinas 35 SEGURIDAD ADVERTENCIA Este calen tador alcanza temperaturas muy altas cuando el calent
50. ausea If you have these signs the heater may not be working properly Get fresh air at once Have heater serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and those at high altitudes 200211 01A NATURAL AND PROPANEILP GAS Natural and Propane LP gas are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor exists A WARNING Any change to this heater or its controls can be dangerous A WARNING Do not use any accessories not approved for use with this heater A WARNING Carefully super vise young children when they are in the room with the heater WARNING Make sure grill guard is in place before running heater A WARNING Due to high tem peratures the appliance should be located out of traffic and away from furniture and draperies WARNING Heater becomes very hot when running Keep children and adults away from hot surfaces to avoid burns or clothing ignition Heater will re main hot for a time after shutoff Allow surfaces to cool before touching A WARNING Do not place clothing or other flammable material on or near the appli ance Never place any objects in the heater www sureheat com 3 SAFETY Do not place Propane LP supply tank
51. be made with a similar product of equal value This warranty does not include transportation or shipping costs of any kind This your exclusive warranty This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not trans ferable Keep the original sales receipt Proof of purchase is required to obtain warranty parts This warranty does not cover normal wear of parts such as scratches and dents of the components or damage resulting from any of the following Negligent use or misuse of the product including exposing the product to chemicals or cleaning products not approved by SHM International Corp Corrosion rust or discoloring of any kind Useorinstallation contrary to specified instructions and applicable building codes including heating the product to temperatures above its rated specifications which can cause considerable warping Disassembly including removal of the product from a built in installation Damageresulting from accident alteration misuse abuse hostile environments or improper installation Repair or alteration Acts of God such as fire flood hurricanes and tornadoes Gas cylinders propane tanks or other fuel delivery systems including connections to a household fuel supply Usage other than single family household use such as commercial or industrial use Minor warping or discoloration of parts which is normal and not a defect under this warranty
52. cendido demorado del quemador La presi n del tubo m ltiple es muyy baja El orificio del quemador est tapado Contacte a su proveedor local de gas Limpie el quemador consulte Cuidado y mantenimiento en la p gina 57 o remplace el orificio del quemador 60 www sureheat com 200211 01A SOLUCI N DE PROBLEMAS Problema Causa Posible Acci n correctiva El quemador presenta llamas deretorno durante la combusti n El orificio del quemador est tapado o El quemador est dafiado El regulador de gas est defectuoso 1 Limpie el quemador consulte Cuidado y mantenimiento en la p gina 57 o remplace el orificio del quemador Remplace el quemador Remplace el regulador de gas Llamas amarillas alta durante la combusti n en el quemador No hay suficiente aire El regulador de gas est defectuoso Laentrada de la presi n de gas es demasiado baja Revise el quemador en busca de polvo y residuos Si los hay limpie el quemador consulte Cuidado y mantenimiento en la p gina 57 Remplace el regulador de gas Contacte a su proveedor local de gas Hay olor a gas durante la combusti n Hay material extra o entre la v lvula de control y el quemador Fugas de gas Consulte la anotaci n de Advertencia p gina 58 Comun quese con un t cnico de servic
53. d connections for leaks after installing or servicing Correct all leaks at once WARNING Never use an open flame to check for a leak Apply a mixture of liquid soap and water to all joints If bubbles form there is a leak Correct all leaks at once Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect heater with its appliance main gas valve control valve and equipment shutoff valve from gas supply piping sys tem Pressures in excess of 1 2 PSIG will damage heater regulator 2 Capoffopen end of gas pipe where equip ment shutoff valve was connected 16 www sureheat com 3 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 200211 01A INSTALLATION 4 Check all joints of gas supply piping sys tem Apply a noncorrosive leak detection fluid to all joints If bubbles form there may be a leak 5 Correct all leaks at once 6 Reconnect heater and eguipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Egual To or Less Than 1 2 PSIG 3 5 kPa 1 Close eguipment shutoff valve see Fig ure 17 2 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or us
54. d gas regulator with wrench when connecting into gas piping and or fittings A CAUTION Use pipe joint sealant that is resistant to gas Propane LP or Natural Gas Before installing heater make sure you have the items listed below external regulator for propane LP unit only supplied by installer piping check local codes sealant resistant to natural gas and pro pane LP gas equipment shutoff valve test gauge connection sediment trap tee joint pipe wrench flexible gas hose check local codes A CSA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable al ternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer Typical Inlet Pipe Diameters Use 3 8 black iron pipe or greater Installa tion must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 15 page 16 IMPORTANT Install an equipment shutoff valve in an accessible location The equip ment shutoff valve is for turning on or shutting off the gas to the appliance 200211 01A www sureheat com 15 INSTALLATION Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves For propane LP gas the installer mus
55. de repuesto en la p gina 63 de este manual ART PARTE DESCRIPCI N CANT 1 gs Ensamble de gabinete 1 2 Reflector unir 1 3 ML087 01 Retenedor de vidrio superior 1 4 MLO86 01 Vidrio 1 5 ML088 01 Retenedor de vidrio inferior 1 6 ES Panel central 1 7 MB09051 Bajar el conjunto del panel frontal 1 8 MB29001 Guardia de parrilla 1 9 MB060 01 Abrazadera de montaje 10 RVD88 MAB 4 9 Ensamble de regulador de presi n 1 11 ML083 04 Asamblea de arrancador 1 12 STL1001 Asamblea de v lvula del termostato 1 18 pel Ensamble de grabadora 1 14 NDD0310A 800 P ODS piloto 1 15 PF06 YJLF BMB Accesorio de ventilador 16 PFO9B Ensamble de base 1 PIEZAS DISPONIBLES NO SE MUESTRAN MB28001 Hardware paquete 1 ML065 01 Termostato de detecci n clip del bulbo 1 160960 01 Asamblea cubierta de la entrada 1 160960 03 Asamblea de montaje de la v lvula 1 MLO73 01 Cable encendedor 1 ML073 05 Cable encendedor 1 No es una pieza que se pueda remplazar en el sitio 200211 01A www sureheat com 67 GARANT A GUARDE ESTA GARANT A Modelo N mero de serie Fecha de compra Conserve su recibo para la verificaci n de la garant a IMPORTANTE Le pedimos gue complete la informaci n de su garant a antes mencionada Completo con todo el n mero de serie gue se puede encontrar en la placa de caracter sticas Conserve este manual para futuras consultas
56. digo Nacional de Gas Combustible ANSI Z223 1 NFPA 54 Aire para Combusti n y Ventilaci n para conocer el tamafio requerido de las rejillas o los conductos de ventilaci n 30 5 cm 12 MAA SS va Rejillas de ventilaci n hacia Rejilas de una habitaci n adyacente ventilaci n O quite Ren 2 hacia una la puerta habitaci n hacia la adyacente habitaci n opci n 1 adyacente opci n 3 Figura 2 Aire del interior de la construcci n para ventilaci n Nota BWH30NLTE No para su uso en dor mitorios o bafios 40 www sureheat com Aire del exterior para ventilaci n Proporcione aire fresco adicional mediante el uso de rejillas o conductos de ventilaci n Debe haber dos aberturas permanentes una a 30 48 cm 12 del techo y otra a 30 48 cm 12 del suelo Conecte estos elementos directamente al exterior o a los espacios que est n abiertos al exterior Estos espacios incluyen ticos y espacios debajo del piso de la casa Consulte el C digo Nacional de Gas Combustible ANSI Z223 1 NFPA 54 Aire para combusti n y ventilaci n para conocer el tamafio requerido de las rejillas o los con ductos de ventilaci n IMPORTANTE No haga aberturas de entra da o de salida de aire hacia el tico si ste tiene ventilaci n el ctrica controlada por un termostato El aire caliente que entre al tico activar la ventilaci n el ctrica tico ventilado Salida de air
57. e Salida de aire Al tico mm espacio debajo del piso Entrada de aire Entrada de aire Espacio ventilado debajo del piso Figura 3 Aire del exterior para ventilaci n 200211 01A INSTALACI N AVISO Este calentador est disefiado para utilizarse como calefacci n adicional Use este calentador junto con su sistema de calefacci n principal No instale este calentador como fuente de calefacci n principal Si tiene un sistema de calefac ci n central puede activar el ventilador de circulaci n del sistema mientras utiliza el ca lentador Esto ayudar a que el calor circule por toda la casa En caso de una interrupci n de la energ a el ctrica puede usar este calentador como su fuente de calefacci n principal A ADVERTENCIA Nunca ins tale el calentador en un dormitorio o ba io no m s de 10 000 Btu hr permiti do en el dormitorio o el bano Verifique los c digos locales en un veh culo recreativo dondecortinas muebles ropa u otros objetos inflamables est n amenos de 0 914 m 36 del frente de la parte superior o laterales del calentador en reas de mucho tr fico en reas con mucho viento o con corrientes fuertes de aire A PRECAUCION Si instala el calentador en la chochera de una casa e el piloto y el quemador del calentador deben estar por lo menos a 45 7 cm 18 sobre el piso s
58. e 45 kg 100 libras de capacidad INFORMACI N DE PATENTES Este producto puede estar cubierto por una o m s de las siguientes patentes de Estados Unidos 8 915 239 8 851 065 8 764 436 8 757 202 8 757 13 8 752 541 8 568 136 8 545 216 8 517 718 8 516 878 8 506 290 8 465 277 8 317 511 8 297 968 8 281 781 8 241 034 8 235 708 8 152 515 8 011 920 7 967 006 7 967 007 7 654 820 7 730 765 7 677 236 7 607 426 7 434 447 www sureheat com 200211 01A ESPECIFICACIONES MODELO BWH10NLMC BWH3ONLTE BTU disponible 1 Encendido Tipo de gas Ajuste del regulador de presi n Presi n del gas de entrada pulg de agua E Tipo de gas f Ajuste del regulador de presi n Presi n del gas de entrada pulg de agua i Dimensiones del calentador alto x ancho x i profundidad Dimensiones caja alto x ancho x profundidad Pesa de calentador Peso con embalaje M ximo 14 de c a 19 4 x 14 1 6 x 6 3 6 10 000 Piezoel ctrico 30 000 Piezoel ctrico Con gas natural Con gas natural 4 de ca M ximo 9 de c a 4 de ca M ximo 9 de c a M nimo 5 de c a M nimo 5 de c a Con gas propano Con gas propano 9 de 9 deca Maximo 14 deca M nimo 11 de c a 23 102 x 2655 8 M nimo 11 de c a 22 x16 37 x 8 1 8 14 6 lbs 17 6 lbs 2531 x 28 Ih x 9 1h 31 Ibs Requisito el ctrico para el kit del ventilador si est equipado Voltaje 120 VAC V C A 60 Hz AGEN
59. e Switch 200211 01A TROUBLESHOOTING Problem Possible Cause Corrective Action When ignitor button is pressed in there is no spark at ODS pilot 1 Ignitor electrode is posi tioned wrong Ignitor elec trode is broken Ignitor electrode is not con nected to ignitor cable Ignitor cable is pinched or wet Broken ignitor cable Bad piezo ignitor Replace pilot assembly Replace ignitor cable Free ignitor cable if pinched Replace ignitor cable Replace piezo ignitor by any metal or tubing Keep ignitor cable dry When ignitor button is pressed in there is a spark at ODS pilot but no ignition Gas supply is turned off or equipment shutoff valve is closed Control knob not fully pressed in while pressing ignitor button Air in gas lines when in stalled ODS pilot is clogged Incorrect inlet gas pressure or inlet regulator is damaged 5 6 Turn on gas supply or open Fully press in control knob Continue holding down con Clean ODS pilot see Care Contact local propane LP equipment shutoff valve while pressing ignitor button trol knob Repeat igniting op eration until air is removed and Maintenance page 23 or replace ODS pilot assembly Check inlet gas pressure or replace inlet gas regulator Turn control knob to PILOT position gas company ODS fpilotlights but flame goes out when co
60. e The hard ware package is provided with heater Attaching to Wall Stud Method For attaching mounting bracket to wall studs 1 Drill holes at marked locations using 9 64 drill bit 2 Place mounting bracket onto wall Line up last hole on each end of bracket with holes drilled in wall 3 Insert mounting screws through bracket and into wall studs 4 Tighten screws until mounting bracket is firmly fastened to wall studs 200211 01A INSTALLATION L 63 4 Min 12 1 8 Only Insert Mounting Screws Through Last Hole On Each End 14 1 2 Min VSNSNNSS Wa Floor Model BWH10NLMC 10 5 2 Min s TI Only Insert Mounting 48 1 Screws Through Last Min Hole On Each End ASIS Nal Floor Model BWH30NLTE Figure 7 Mounting Bracket Clearances Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry 1 Drill holes at marked locations using 5 16 drill bit For solid walls concrete or masonry drill at least 1 deep Fold wall anchor as shown in Figure 8 Insert wall anchor wings first into hole Tap anchor flush to wall For thin walls 1 2 or less insert red key into wall anchor Push red key to pop open anchor wings see Figure 9 IMPORTANT Do not hammer anchor key For thick walls over 1 2 thick or
61. e Habitaci n Consejos para servicio Sin 39 Servicio t cnico Aire para combusti n y ventilaci n 39 Instalaci n ee 41 GUARDE ESTE MANUAL INSTALADOR Deje este manual con el aparato CONSUMIDOR Conserve este manual para referencias futuras Este es un calentador de llama de gas sin ventilaci n Utiliza aire ox geno de la habitaci n en la que se instala Se deben tomar las medidas necesarias para asegurar que haya suficiente aire para ventilaci n y combusti n Consulte la secci n Aire para combusti n y ventilaci n en la p gina 39 de este manual A ADVERTENCIA La instalaci n ajuste alteraci n servicio o mantenimiento inadecuados pueden provo car lesiones o da os a la propiedad Consulte este ma nual para conocer los procedimientos de instalaci n y operaci n correctos Para obtener asistencia o informa ci n adicionales consulte a un instalador capacitado agencia de servicio o al proveedor de gas Este aparato puede ser instalado en una casa m vil con ubicaci n permanente y adquirida en el mercado de posventa siempre que no est prohibido por los c digos locales Este dispositivo es s lo para su uso con propano o gas natural No se permite la conversi n de campo por cualquier otro medio incluido el uso de un kit Mercado de posventa venta comple
62. e a un t cnico de servicio calificado o a su proveedor de gas para que realicen las reparaciones necesarias Hasta que se hagan las reparaciones encender el piloto con un f sforo Bot n del encendedor ES Perilla de control Figura 20 Perilla de control en la posici n OFF apagado 200211 01A FUNCIONAMIENTO Si al soltar la perilla de control sta no regresa a su posici n original llame a un t cnico de servicio calificado o a su proveedor de gas para que realicen las reparaciones necesarias 6 Contin e presionando la perilla de control y al mismo tiempo oprima y suelte el bot n de encendido Esto encender el piloto EI piloto est instalado en la parte anterior del quemador El piloto puede ser visto a trav s de la parrilla En caso ne cesario contin e oprimiendo el bot n de encendido hasta que el piloto encienda Nota Si el piloto no se mantiene encen dido consulte la secci n Soluci n de problemas en la p gina 58 Tambi n en contacto con un t cnico de servicio calificado o proveedor de gas para las reparaciones Encienda el piloto con un f sforo hasta que se realicen las repara ciones Para encender el piloto con un f sforo Consulte el Procedimiento para encendido manual en la p gina 54 7 Una vez que haya encendido el piloto mantenga la perilla de control presionada durante 30 segundos Despu s de los 30 segundos suelte la perilla de control Si la perilla de con
63. e montaje Inserte los tornillos de montaje en estos orificios solamente 3 Quite la cinta y el soporte de montaje de la pared Instalaci n del soporte de montaje a la pared Nota Los anclajes de pared los tornillos de montaje y los separadores se encuentran en el paquete de ferreteria El paquete de ferre ter a se incluye con el calentador 200211 01A M todo de fijaci n a viga de pared Para fijar el soporte de montaje a las vigas de pared 1 Perfore orificios en los lugares marcados utilizando una broca de 9 64 2 Coloque el soporte de montaje en la pared Alinee el ltimo orificio de cada extremo del soporte con los orificios que perfor en la pared 3 Inserte los tornillos de montaje en el so porte y en las vigas de pared 4 Apriete los tornillos hasta que el soporte de montaje est asegurado firmemente a las vigas de pared 17 cm 6 2 4 orificio de cada extremo Min 31 cm 12 t s a 2 N 8 e Inserte los tornillos 36 8 4 de montaje s loa 14 1 2 4 trav s del ltimo Min p Piso Modelo BWH10NLMC 27 cm 10 5 Min T 2 8 2 Inserte los tornillos 47cm 6 de montaje s loa 18 1 2 4 trav s del ltimo n apie B A orificio de cada extremo p Piso Modelos BWH30NLTE Figura 7 Distancias m nimas del soporte de montaje www sureheat com 43 INSTAL
64. eater are blocked Dirty or partially clogged burner orifice Turn control knob to low 1 position and let warm up for a minute Operate burner until air is removed from line Have gas line checked by local gas supplier Observe minimum installa tion clearances Figure 4 page 9 Clean burner see Care and Maintenance page 23 or replace burner orifice Heater produces a click ing ticking noise just after burner is lit or shut off White powder residue forming within burner box or on adjacent walls or furniture Metal is expanding while heating or contracting while cooling When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue This is common with most heaters If noise is exces sive contact qualified ser vice technician Turn heater off when using furniture polish wax carpet cleaner or similar products 26 www sureheat com 200211 01A TROUBLESHOOTING Problem Possible Cause Corrective Action Heater produces un wanted odors Heateris burning vapors from paint hair spray glues etc See IMPORTANT statement page 24 Gas leak See Warning State ment at the top of page 24 Low fuel supply propane LP gas only 1 Ventilate room Stop using odor causing products while heater is running Locate and correct all leaks see Checking Gas C
65. ecuadas del aire 2 Si hay humedad elevada se puede uti lizar un des humidificador para ayudar a reducir el contenido de vapor de agua del aire 3 No utilice un calentador de habitaci n sin ventilaci n como fuente principal de calefacci n AIRE PARA COMBUSTI N Y VENTILACI N ADVERTENCIA Este calen tador no se debe instalar en un espacio reducido o excepcional mente herm tico a menos que se tomen las precauciones necesa rias parala combusti n adecuada y ventilaci n de aire Lea las instrucciones siguientes para asegurarse de aire fresco para ste y otros aparatos que queman combustible en su hogar Las casas de hoy se construyen m s energ a eficiente que nunca Nuevos materiales mejor aislamiento y los nuevos m todos de cons trucci n ayudan a reducir la p rdida de calor enlos hogares Los propietarios de viviendas burletes y calafateo alrededor de las ventanas y puertas para mantener el aire fr o y el aire caliente adentro Durante la temporada de calor los duefios de casa quieren que sus casas lo m s herm tica posible Mientras que es bueno para hacer su hogar de energ a eficiente su hogar necesita respirar El aire fresco debe entrar a su casa Todos los apara tos que queman combustible necesitan aire fresco para la combusti n y la ventilaci n adecuada Los extractores de aire chimeneas se cadoras de ropa y aparatos que queman combustible toman aire de la casa durante su 2
66. ed burner s ignition of a Manifold pressure is too low Burner orifice is clogged a Contact local gas supplier 2 Clean burner see Care and Maintenance page 23 or replace burner orifice Burner backfiring during combustion a oN Burner orifice is clogged or damaged Burner is damaged Gas regulator is damaged Clean burner orifice see Care and Maintenance page 23 or replace burner orifice Replace burner Replace gas regulator High yellow flame during burner combustion won Not enough air Gas regulator is defective Inlet gas pressure is too low Check burner for dirt and debris If found clean burner see Care and Maintenance page 23 Replace gas regulator Contact local gas supplier Gas odor during com bustion a Foreign matter between control valve and burner Gas leak See Warning Statement at top of page 24 Take apart gas tubing and remove foreign matter Locate and correct all leaks see Checking Gas Connec tions page 16 Slight smoke or odor dur ing initial operation a Residues from manufactur ing process Problem will stop after a few hours of operation Heater produces a whis tling noise when burner is lit a Turning control knob to high 5 position when burner is cold Air in gas line Air passageways on h
67. el instalador calificado debe encender el aparato Consulte el patr n correcto de la llama como se ilustra en la p gina 66 Todos los de la llama debe ser de forma segura en el interior del producto Si por alguna raz n no es as deje de utilizar el aparato y llame para las reparaciones Interruptor de presi n tornillo de fijaci n Figura 29 Interruptor de presi n del regulador de gas 200211 01A SOLUCI N DE PROBLEMAS Problema Causa Posible Acci n correctiva Cuando se presiona el bot n del encendedor no hay chispa en el piloto ODS a Electrodo de encendido est mal colocado Electro do de encendido est roto El electrodo del encende dor no est conectado al cable del encendedor El cable del encendedor est comprimido o mojado EI cable del encendedor est roto El encendedor piezoel ctri co est defectuoso 1 Remplace el electrodo del encendedor Remplace el cable del encen dedor Libere el cable del encendedor si alg n metal o tuber a lo est comprimiendo Mantenga seco el cable del encendedor Remplace el cable del encen dedor Remplace el encendedor pie zoel ctrico Cuando se presiona el bot n del encendedor hay chispa en el piloto ODS pero no se en ciende a El suministro de gas est cerrado o la v lvula de cie rre del eguipo est cerrada La perilla de control no se
68. erior del calentador consulte la figura 10 Coloque el calentador en el soporte de montaje Deslice las ranuras horizontales hacia las leng etas salientes del soporte de montaje Ranuras horizontales Soporte de montaje fijado a la Leng et pared saliente Figura 10 Montaje del calentador en el soporte de montaje Instalaci n de los tornillos de montaje inferiores Instale el soporte base en la parte inferior del calentador con dos tornillos Puede ser m s c modo retirar el calentador del soporte de pared para la colocaci n 2 Coloque el calentador sobre el soporte de montaje de pared 3 Marque la ubicaci n de los tornillos en la pared 4 Quite el calentador del soporte de montaje 200211 01A INSTALACI N 5 Si va a instalar los tornillos de montaje inferiores en una pared hueca o s lida instale los anclajes de pared Siga los pasos 1 a 4 en M todo de fijaci n a an clajes de pared pagina 44 Si va ainstalar el tornillo inferior de montaje en la viga de pared perfore orificios en los lugares marcados con una broca de 9 64 6 Vuelva a colocar el calentador en el so porte de montaje Pared 7 Coloque los separadores entre los orifi cios de montaje inferiores y el anclaje de pared o el orificio que perfor 8 Sostenga el separador en su sitio con una mano Con la otra mano inserte el tornillo Separador de montaje a trav s del orificio inferior de montaje y del separador
69. eza no aprobados por SHM International Corp Corrosi n oxidaci n o des coloraci n de cualquier tipo Usoo instalaci n contrarios a las instrucciones especificadas y a los c digos de construcci n vigentes incluida la pr ctica de calentar el producto a temperaturas que superan sus especificaciones lo cual puede ocasionar una torsi n considerable Desmontaje incluido el retiro del producto de una instalaci n incorporada Dafio causado por accidentes modificaciones mal uso abuso condiciones adversas o instalaci n incorrecta Reparaci n o modificaci n Desastres naturales como incendio inundaci n huracanes y tornados Cilindros de gas tanques de propano u otros sistemas de distribuci n de combustibles incluidas las conexiones a un suministro de combustible dom stico Uso para fines que no sean calefaccionar una casa familiar como uso comercial o industrial Torsi n o descoloraci n menor de las piezas lo cual es normal y no constituye un defecto bajo las con diciones de esta garant a NO DEVUELVA ESTE PRODUCTO AL LUGAR DONDE LO COMPR Si el aparato no funciona correctamente primero siga detalladamente las instrucciones proporcionadas con la unidad para asegurarse de que el aparato est instalado de manera correcta y consulte la sec ci n de soluci n de problemas en el manual de uso y mantenimiento Le recomendamos que env e de vuelta la tarjeta de registro de garant a para que pueda recibir
70. f your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Call Customer Service toll free at 1 800 229 5647 to order parts not under warranty When calling Customer Service have ready Model number of your heater The replacement part number 200211 01A www sureheat com 31 WARRANTY KEEP THIS WARRANTY Model Serial No Date Purchased Keep receipt for warranty verification IMPORTANT We urge you to fill out your warranty information above Complete with the entire serial number which can be found on the rating plate Retain this manual for future reference Always specify model and serial numbers when communicating with customer service We reserve the right to amend these specifications at any time without notice The only warranty applicable is our standard written warranty We make no other warranty expressed or implied LIMITED WARRANTY SHM International Corp warrants the components of this appliance to be free from defects in material and workmanship for one 1 year from the date of purchase SHM International Corp at its option will repair or replace this product or any component of the product found to be defective during the warranty period Replacement will be made with a new manufactured product or component If the product is no longer available replacement may
71. floja en la v lvula de control La llama del piloto no est tocando el termopar lo que hace que el termopar se enfr e y ocasiona que la llama del piloto se extinga Este problema puede ser ocasionado por alguna de las siguientes condiciones o por ambas A Baja presi n del gas B El piloto ODS est sucio O parcialmente tapado El termopar est da ado La v lvula de control est da ada 1 2 Presione la perilla de control completamente Despu s de que el piloto ODS se encienda mantenga la perilla de control presionada durante 30 segundos Abra la v lvula de cierre del equipo totalmente Apriete con la mano hasta que sienta que topa luego apriete 1 4 de vuelta m s A Comun quese con la com pa a local de gas natural o de gas propano LP B Limpie el piloto ODS con sulte Cuidado y mantenimien to en la p gina 57 o remplace el ensamble del piloto ODS Remplace el termopar Remplace la v lvula de con trol El quemador no se en ciende despu s de que el piloto ODS se enciende El orificio del quemador est tapado El di metro del orificio del quemador es demasiado peque o La entrada de la presi n de gas es demasiado baja Limpie el quemador consulte Cuidado y mantenimiento en la p gina 57 o remplace el quemador Remplace el orificio del que mador Contacte a su proveedor local de gas En
72. h the gas This pro vides a clean burning flame Keep this hole clear of dust dirt and lint Clean this air inlet hole prior to each heating season A blocked air hole will create soot We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Your local computer store hardware store or home center may carry compressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could damage the pilot assembly 1 Shutoffthe unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner and pilot for dust and dirt 3 Blow air across the ports slots and holes in the burner 4 Never insert objects into the pilot tube Clean the pilot assembly also A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air inlet about 2 from where the pilot flame comes out of the pilot assembly see Figure 28 With the unit off lightly blow air through the air inlet You may blow through a drinking straw if compressed air is not available Ignitor Electrode Natural Gas Burner Thermocou
73. iende 9 WC Presi n inicial supera los Presostato Bypass Vea las instrucciones de abajo Interruptor de presi n Cuando se usa gas natural NG hay un interruptor de presi n que act a para apagar el flujo de gas al piloto si la presi n de entrada excede 9 WC Esto es para prevenir la opera ci n de la unidad en el gas de mal propano LP Si el suministro de gas natural supera los 9 WC la unidad no funcionar O p ngase en contacto con su proveedor de gas para comprobar y ajustar la presi n de entrada o un t cnico de servicio calificado puede pasar por alto el interruptor de presi n Antes de tratar de pasar por alto el interruptor de presi n aseg rese de que el tipo de gas que se utiliza es la correcta Aseg rese de que el accesorio de conexi n se encuentra en la entrada correcta en el regulador Consulte Co nexi n a Suministro de gas en la p gina 48 S lo un t cnico calificado debe pasar por alto el interruptor de presi n Para anular el interruptor de presi n localizar el tornillo de ajuste en el regulador Utilice un peque o destornillador de punta plana para girar el tornillo de ajuste 58 www sureheat com en sentido antihorario 2 vueltas Esto pasar por alto la funci n de interruptor de presi n La tuber a de suministro de gas completa inclui das las conexiones en el interior del calentador debe probar contra fugas por el instalador auto rizado Despu s de la fuga probar
74. informa ci n sobre cualquier asunto de seguridad que pueda surgir y que pueda afectarle Enviar de vuelta la tarjeta de registro de garant a no es una condici n para obtener cobertura de garant a Debido a que este producto est mejorando constantemente estas especificaciones est n sujetas a cambios sin previo aviso Si tiene otras consultas o si necesita piezas de reemplazo p ngase en contacto con nuestra l nea direc ta de Servicio al cliente llamando al tel fono 800 229 5647 o visite nuestro sitio Web en www Sure Heat com 200211 01 SHM International Corp 3140 Moon Station Road Kennesaw GA 30144 Rev A 04 15
75. ing compressed air 3 Check all joints from gas meter natural gas installations see Figure 18 or from propane LP tank propane LP gas installa tions see Figure 19 to equipment shutoff valve Apply a noncorrosive leak detection fluid to all joints If bubbles form there is a leak 4 Correct all leaks at once i 44 Open Figure 17 Equipment Shutoff Valve Equipment Shutoff Valve Gas Valve Y Y Gas Meter Equipment oa Shutoff Valve Figure 18 Natural Gas Supply Gas Valve Propane LP Supply Tank Equipment H Shutoff Valve Figure 19 Propane LP Fuel Supply PRESSURE TESTING HEATER GAS CONNECTIONS 1 Open equipment shutoff valve see Fig ure 17 2 For natural gas open main gas valve lo cated on or near gas meter For propane LP gas open propane LP supply tank valve 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 18 or 19 Apply a noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operation page 18 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 19 or 20 8 Replace lower front panel 200211 01A www sureheat com
76. io capacitado para eliminar los materiales extra os Localice y repare todas las fugas consulte Revisi n de las conexiones de gas en la p gina 50 Hay un poco de humo u olor durante el funciona miento inicial Residuos del proceso de manufactura y ahumado del le o El problema desaparecer despu s de algunas horas de funcionamiento El calentador produce un silbido cuando el quema dor est encendido Se gir la perilla de control a la posici n alto 5 cuan do el quemador estaba fr o Hay aire en la tuber a de gas Los pasajes de aire del ca lentador est n bloqueados El orificio del quemador est sucio o parcialmente obstruido Gire la perilla de control a la posici n bajo 1 y deje que se caliente durante un minuto Haga funcionar el quemador hasta que se elimine el aire de la tuber a Pida a la empresa proveedor local de gas que revise la l nea de gas Respete las distancias m ni mas de instalaci n consulte Figura 4 pagina 42 Limpie el quemador consulte Cuidado y mantenimiento en la p gina 57 o remplace el orificio del quemador El calentador produce un ruido de chasquidos o golpeteos met licos justo despu s de que el quemador se enciende o se apaga Los metales se dilatan al calentarse y se contraen al enfriarse Esto es normal en la mayor a de los calentadores Si el ruido es excesivo c
77. it e el calentador donde nin g n veh culo en movimiento lo pueda golpear A ADVERTENCIA Un t cni co calificado debe realizar la instalaci n Respete todos las normas locales 200211 01A PRECAUCI N Este calen tador crea corrientes de aire caliente Estas corrientes mue ven el calor hacia la superficie de las paredes pr ximas al calentador La instalaci n del calentador cerca de paredes con recubrimientos de vinilo o tela o la operaci n del calentador en lugares donde existan im purezas en el aire como humo de tabaco velas arom ticas l quidos limpiadores l mparas de aceite o de queroseno entre otros puede manchar las pare des o producir olores www sureheat com IMPORTANTE Los calentadores sin ventila ci n a aden humedad al aire Aunque esto es ben fico la instalaci n del calentador en habitaciones sin suficiente aire de ventilaci n puede ocasionar la formaci n de moho debido al exceso de humedad Consulte Aire para Combusti n y Ventilaci n en la p gina 39 VERIFIQUE EL TIPO DE GAS Aseg rese de que el suministro de gas es apropiado para el calentador De lo contrario llame al distribuidor donde compr el calen tador para el calentador de tipo adecuado 41 INSTALACI N DISTANCIA DE SEPARACI N DE COMBUSTIBLES Siga con atenci n las siguientes instruc TECHO ciones Este calentador es una unidad de montaje en la pared dise ada para apoya
78. k around windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your home needs to breathe Fresh air must enter your home All fuel burning ap pliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces clothes dryers and fuel burning appliances draw air from the house to operate You must provide adequate fresh air for these appliances This will insure proper venting of vented fuel burning appliances WARNING Ifthe areain which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction provide adequate combustion and ventilation air byoneofthe methods described in the National Fuel Gas Code ANSI Z223 1 NFPA 54 the In ternational Fuel Gas Code or applicable local codes 200211 01A www sureheat com AIR FOR COMBUSTION AND VENTILATION VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 ofthe ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code AN
79. nspecting Heater Local Codes Care And Maintenance Preparing For Installation T Troubleshooting Unpacking Accessories Water Vapor By Product Of Service Hints Unvented Room Heaters 6 Technical Service Air For Combustion and Ventilation 7 Replacement Parts installation as 9 Warranty coti e dn SAVE THIS BOOK INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for ad equate combustion and ventilation air mustbe provided Refer to Air For Combustion and Ventilation section on page 7 of this manual A WARNING Improper installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For assistance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by local codes This appliance is only for use with propane or natural gas Field conversion by any other means including the use of a kit is not permitted
80. ntrol knob is released Control knob not in PILOT position Depleted gas supply pro pane Control knob is not fully pressed in Control knob is not pressed in long enough Equipment shutoff valve is not fully open Thermocouple connection is loose at control valve Pilot flame not touching thermocouple which allows thermocouple to cool caus ing pilot flame to go out This problem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot Thermocouple damaged Control valve damaged Press in control knob fully After ODS pilot lights keep Fully open equipment shutoff Hand tighten until snug and A Contact local natural or Replace thermocouple T control knob pressed in 30 seconds valve then tighten 1 4 turn more propane LP gas company B Clean ODS pilot see Care and Maintenance page 23 or replace ODS pilot as sembly Replace control valve 200211 01A www sureheat com 25 TROUBLESHOOTING Problem Possible Cause Corrective Action Burner s does not light after ODS pilot is lit Burner orifice is clogged Burner orifice diameter is too small 3 Inlet gas pressure is too low Clean burner orifice see Care and Maintenance page 23 or replace burner orifice Replace burner orifice Contact local gas supplier Delay
81. ntrol presionada durante 30 segundos Despu s de 30 segundos suelte la perilla de control Realice el paso 8 de las Instrucciones de encendido p gina 52 o 53 5 Vuelva a colocar el panel anterior 54 www sureheat com C mo apagar el quemador s lo permanece encendido Gire la perilla de control en direcci n de la manecillas del reloj hasta la posici n PILOT IGN piloto endendedor PROCEDIMIENTO PARA ENCENDIDO MANUAL PEE TODOS LOS MODELOS Electrodo del encendedor Quemador de gas natural Termopar Quemador de Gas Propano LP Orificio de entrada de aire al piloto Orificio de entrada de aire al piloto Figura 22 Conjunto de piloto 200211 01A CONEXI N EL CTRICA PARA CALENTADORES EQUIPADO CON UN VENTILADOR A No utilice este calentador si alguna de sus piezas estuvo sumergida en agua Llame de inmediato a un t cnico en man tenimiento calificado a fin de que inspeccione la calentador y remplace cualquier pieza del sistema el ctrico que haya es tado bajo agua INSTRUCCIONES DE CONEXI N A TIERRA Este calentador fue disefiado para su uso con 120 voltios El cable tiene un enchufe como se muestra en la Figura 23 Hay un adaptador disponible como se muestra en la C para conectar enchufes con conexi n a tierra de tres clavijas a recept culos de dos ranuras La terminal verde de conexi n a tierra que sale del adaptador se debe conectar perma nentemente a tierr
82. ny of the original wire as supplied with the appli ance must be replaced it must be replaced with a wire of at least a 105 C temperature rating Thermostat Switch Black Green www sureheat com 21 INSPECTING HEATER IMPORTANT Owner s should check pilot flame pattern and burner flame pattern often Incorrect flame patterns indicate the need for cleaning see Care and Maintenance page 23 or service A WARNING Only a qualified service person should service and repair heater This includes maintenance requiring replacement or alteration of components PILOT FLAME PATTERN Figure 24 shows a correct pilot flame pattern Figure 25 shows an incorrect pilot flame pat tern The incorrect pilot flame is not touching the thermocouple This will cause the ther mocouple to cool which shuts the heater off If pilot flame pattern is incorrect as shown in Figure 25 turn heater off see To Turn Off Gas to Ap pliance page 19 or 20 see Troubleshooting pages 24 through 27 A WARNING If yellow tipping occurs your heater could pro duce increased levels of carbon monoxide If the burner flame pattern shows yellow tipping follow instructions below Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the heater and burn causing brief patches of orange flame Figure
83. o con una mezcla de agua y jab n suave Frote el gabinete para quitar el polvo 200211 01A www sureheat com 57 SOLUCI N DE PROBLEMAS Cierre el suministro de gas el edificio de bomberos dh ADVERTENCIA Si percibe olor a gas No intente encender ning n aparato No toque ning n interruptor el ctrico no use ning n tel fono en Llame inmediatamente a su proveedor de gas desde el tel fono de alg n vecino Siga las instrucciones del proveedor de gas Si no puede localizar al proveedor de gas llame al departamento ADVERTENCIA S louna personadeservicio capacitada debe reparar la calentador y darle servicio Aseg rese de que el equipo est apagado antes de proceder Apague y deje que se enfr e antes de darle servicio PRECAUCI N Nunca utilice un alambre aguja u objetos parecidos para limpiar el piloto ODS Esto puede da ar la unidad de piloto ODS IMPORTANTE Si hace funcionar el calentador donde existen impurezas en el aire se pueden producir olores Los productos de limpieza pintura solventes de pintura humo de cigarro cementos y pegamentos alfombras o textiles nuevos etc producen gases Estos gases se pueden mezclar con el aire que se utiliza para la combusti n y producir olores Nota Todos los puntos para soluci n de problemas se listan en orden de funcionamiento Problema Causa Posible Acci n Correctiva El uso de gas natural y el piloto no se enc
84. omun quese con una persona de servicio capacitada 200211 01A www sureheat com 61 SOLUCI N DE PROBLEMAS Problema Causa Posible Acci n correctiva Se forma un residuo de polvo blanco dentro de la caja del quemador o en las paredes o muebles contiguos Cuando se calientan los vapores provenientes de los pulidores de muebles cera limpiadores de alfom bras etc pueden conver tirse en residuos de polvo blanco 1 Apague la calentador cuando utilice pulidores de muebles ceras limpiadores de alfom bras o productos parecidos El calentador produce olores no deseados En el calentador se est n quemado vapores prove nientes de pintura fijador para el cabello pegamen tos productos de limpieza productos qu micos alfom bras nuevas etc Consul te la nota IMPORTANTE pagina 58 Fugas de gas Consulte la anotaci n de Advertenci p gina 58 Hay poco suministro de combustible 1 Abra la ventana para ventilar la habitaci n Deje de utilizar los productos que ocasionan el olor mientras el calentador est funcionando 2 Localice y repare todas las fugas consulte Revisi n de las conexiones de gas en la p gina 50 3 Surta nuevamente el tanque de suministro gas propano LP nicamente EI calentador se apaga mientras se est usando el ODS funciona No hay suficiente aire fres co Hay poca presi n en la tuber a
85. onnec tions page 16 Refill supply tank Propane LP models Heater shuts off in use ODS operates Not enough fresh air is avail able Low line pressure ODS pilot is partially clogged Open window and or door for ventilation Contact local gas supplier Clean ODS pilot see Care and Maintenance page 23 Gas odor exists even when control knob is in OFF position Gas leak See Warning Statement at top of page 24 Control valve is defective Locate and correct all leaks see Checking Gas Connec tions page 16 2 Replace control valve Moisture condensation noticed on windows Not enough combustion ventilation air Refer to Air for Combus tion and Ventilation require ments page 7 ACCESSORIES Purchase these heater accessories from your local dealer If they can not supply these acces sories contact SHM International Corp at 1 800 229 5647 for information EQUIPMENT SHUTOFF VALVE RMH 120 00088 For all models Equipment shutoff valve with 1 8 NPT tap SERVICE HINTS pilot will not stay lit e burners will have delayed ignition fireplace will not produce specified heat e propane LP gas supply might be low propane LP units only You may feel your gas pressure is too low If so contact your local gas supplier TECHNICAL SERVICE When Gas Pressure Is Too Low You may have further questions ab
86. os desde el interior del regulador El mbolo se empuj hacia atr s como se instala el accesorio Aseg rese de queeltipo de gas que se utiliza es la correcta Aseg rese de que el accesorio de conexi n se encuentraenlaentradacorrectaen el regulador Consulte Conexi n a Suministro de Gas en la p gina 48 Si est utilizando el gas natural y E H H S el piloto no se enciende consul te Soluci n de Problemas en la p gina 58 NO QUITE Tapa de Amarillo Gas Natural mbolo metal Instale Gas Fitting Aqu 200211 01A www sureheat com 47 INSTALACI N CONEXI N AL SUMINISTRO DE GAS ADVERTENCIA Una per sona de servicio capacitada debe conectar el calentador al suministro de gas Siga todas las normas locales ADVERTENCIA Este aparato reguiere una conexi n de entra da tipo NPT rosca de tuber a nacional de 3 8 al regulador de presi n ADVERTENCIA Para gas na tural nunca conecte el calenta dora pozos de gas privados que no sean de servicio p blico Este gas se conoce com nmente como gas de pozo PRECAUCI N Para gas propano LP nunca conecte el calentador directamente al sumi nistro de gas propano LP Este calentadorrequiere un regulador externo no se incluye Instale el regulador externo entre el ca lentador y el suministro de gas propano LP El proveedor de gas debe suministrar un regulador externo para el gas natural El t cnico capacitado proporciona
87. os vapores y l quidos inflamables cerca de este aparato ni de cualquier otro QU HACER SI PERCIBE OLOR A GAS e No intente encender ning n aparato e No toque ning n interruptor el ctrico no use ning n tel fono en el edificio e Llame inmediatamente a su proveedor de gas desde el tel fono de alg n vecino Siga las instrucciones del proveedor de gas e Si no puede localizar al proveedor de gas llame al departamento de bomberos La instalaci n y el servicio deben ser realizados por un instalador capacitado una agencia de servicio o el proveedor de gas T Preguntas problemas piezas faltantes Antes de volver a la tienda llame a nuestro Departamento de Servicio al Cliente al 1 800 229 5647 de lunes a viernes de 8 00 a m a 4 30 p m hora est ndar del Este TABLA DE CONTENIDOS ironia 35 Funcionamiento cce ci 37 Conexi n El ctrica Agencia de Instalaci n Calificada 37 Cableado El ctrico Caracter sticas del Producto Inspecci n del calentador Norrmias Locales iced Cuidado y mantenimiento Preparaci n Para la Instalaci n Soluci n de problemas Piezas de repuesto Vapor De Agua Un Producto Derivado ACCOSOMOS a nn de Los Calentadores d
88. out installation operation or troubleshooting If so contact SHM International Corp at 1 800 229 5647 When calling please have your model and serial numbers of your heater ready 200211 01A www sureheat com 27 PARTS MODEL BWH1ONLMC 4 4 yp gt gm IM VW QAM d SU u 28 www sureheat com 200211 01A PARTS MODEL BWH10NLMC This list contains replaceable parts for your heater When ordering replacement parts follow the instructions listed under Replacement Parts on page 31 of this manual ITEM PART DESCRIPTION QTY 1 Cabinet Assembly 1 2 Reflector Unit 1 3 ML087 03 Upper Glass Retainer 1 4 ML086 03 Glass 1 5 ML088 03 Lower Glass Retainer 1 6 ML084 03 Middle Panel 1 if MB09003 Lower Front Panel Assembly 1 8 MB29003 Grill Guard 1 9 MB06 02 Mounting Bracket 1 10 ML083 04 Ignitor Assembly 1 11 Assembly 1 12 NV2020 1213B Control Valve 1 13 RVD88 P 4 9 L Pressure Regulator Assembly 1 14 NDD0310A 600 P ODS Pilot 1 15 PF0910B Base Assembly 1 16 MB16002A Control Knob Assembly 1 PARTS AVAILABLE NOT SHOWN MB28001 Hardware Package 1 160960 01 Inlet Cover Assembly 1 160960 03 Valve Fitting Assembly 1 ML073 02 Ignitor Cable 1 ML073 06 Ignitor Cable 1 Not a field replaceable part www sureheat com 29 30 PARTS MODEL
89. ple Propane LP Gas Burner Pilot Air Inlet Hole Pilot Air Inlet Hole Figure 28 Pilot Inlet Air Hole CABINET Air Passageways Use pressurized air to clean 200211 01A Exterior Use a soft cloth dampened with a mild soap and water mixture Wipe the cabinet to re move dust www sureheat com 23 TROUBLESHOOTING A WARNING If you smell gas Shut off gas supply building Do not try to light any appliance Do not touch any electrical switch do not use any phone in your Immediately call your gas supplier from a neighbor s phone Fol low the gas supplier s instructions f you cannot reach your gas supplier call the fire department WARNING Only a qualified service technician should service and repair heater Make sure that power is turned off before proceeding Turn off and let cool before servicing CAUTION Never use a wire needle or similar object to clean ODS pilot This can damage ODS pilot unit IMPORTANT Operating heater where impurities in air exist may create odors Cleaning sup plies paint paint remover cigarette smoke cements and glues new carpet or textiles etc create fumes These fumes may mix with combustion air and create odors Note All troubleshooting items are listed in order of operation Problem Possible Cause Corrective Action Using natural gas and pilot will not light Inlet pressure exceeds 9 WC Bypas
90. plete tightening of the fitting Install additional fitting to connect to the house supply FOR NATURAL GAS NG INSTALLATION YELLOW Remove the blue dust cover from the regulator Blue Dust Cover Remove the metal cap installed over the NG regulator inlet VY N N ZN A Metal Cap Install metal cap over LP Propane regulator inlet This will keep debris out of regulator 941 z DO NOT REMOVE Metal Cap Install Gas Fitting Here www sureheat com Use only the cap supplied onthe regulator Do not use an off the shelf pipe plug This can damage the plunger The supplied regula tor cap is designed so it will not engage the unused gas type 4 Apply thread sealant to the threads on the connection fitting While pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to complete tightening of the fitting Install additional fitting to connect to the house supply DO NOT use an off the shelf 3 8 NPT pipe plug This will damage the plungers located inside the regulator DONOT try toremove the plung ers from inside the regulator The plunger will be pushed back as the fitting is installed Make sure the type of gas being used is correct Check to make sure the connection fitting is in the correct inlet on the regula tor Refer to Connecting to Gas Supply page 15
91. plosi n No use este aparato si alguna de sus partes estuvo sumergida en agua Llame inmediatamente a un t cnico ca pacitado de servicio para que inspec cione el aparato y remplace las piezas del sistema de control y los controles de gas que hayan estado sumergidos en agua MODELO BWH30NLTE EE INSTRUCCIONES DE ENCENDIDO MAA iALTO Lea la informaci n seguridad antes mencionada Aseg rese de que la v lvula de cierre del equipo est totalmente abierta Gire la perilla de control en direcci n de la manecillas del reloj hasta la posici n OFF apagado Espere cinco minutos a que se disipe el gas Luego compruebe que no huela a gas incluso cerca del piso Si percibe olor agas DET NGASE Siga el punto B en la informaci n de seguridad por encima Si no percibe olor a gas contin e con el siguiente paso Gire la perilla de control en direcci n contraria a las manecillas del relo hasta la posici n PILOT piloto Manten ga presionada la perilla de control durante cinco 5 segundos consulte la figura 20 Nota es posible que sta sea la primera www sureheat com vez que hace funcionar el calentador des pu s de conectarlo al suministro de gas Si es asi es posible que deba presionar la perilla de control durante 30 segundos o mas Esto permitir que el aire salga del sistema de gas En caso que el piloto no encienda consulte la secci n Soluci n de problemas en la p gina 58 Tambi n llam
92. rrancador hasta luces de piloto 7 Mantenga la perilla de control pulsado durante 10 diez segundos al piloto de iluminaci n Si el piloto sale repita los pasos del 5 6 y 7 8 Para seleccionar el nivel deseado de calefacci n parcialmente presiona li geramente el mando de control y girar en sentido antihorario gt Liberar la presi n descendente sobre el pomo mientras continuaba hasta las cerraduras de perilla a la posici n de ajuste deseado No operan entre posiciones bloqueadas Perilla de control conjunto en posici n de calefacci n deseada Nota Ambos son altas y bajas posiciones bloqueadas Debe presionar en el mando de control antes de girar de estos posiciones OFF PILOT IGN HIGH LOW Bot n del encendedor Perilla de control Figura 21 Perilla de control en la posici n OFF apagado C MO CERRAR EL SUMINISTRO DE GAS AL APARATO MN C mo apagar el calentador 1 Gire la perilla de control en direcci n de la manecillas del reloj hasta la posici n OFF apagado 2 Si va a realizar alg n trabajo de man tenimiento desconecte el suministro de energ a el ctrica al calentador 1 Desmonte el panel delantero inferior 2 Realice los pasos 1 a 7 de las Instruccio nes de encendido p gina 52 o 53 3 Con la perilla de control presionada encienda un f sforo Sostenga el f sforo en el piloto hasta que ste se encienda 4 Una vez que haya encendido el piloto mantenga la perilla de co
93. rse _ gt pnminime A 20 3 cm de 91 5 cm directamente sobre el suelo o una base de 8 36 repisa Distancias m nimas sn Ay ADVERTENCIA Mantenga delos las distancias m nimas como del ii se muestra en la Figura 4 Si es calentador BYRNE N M Wl RAO LE YY posible proporcione distancias mayores respecto al suelo al te izquierdo cho y a las paredes adyacentes oon dE z cm 2 Distancia m nima a la superficie de la Mida desde el punto mas alejado alfombra azulejo u otro material combustible del calentador Ser Figura 4 Distancias minimas de montaje vistas desde la parte anterior del calentador UBICACI N DEL CALENTADOR Este calentador est dise ado para montarse Donde haya f cil acceso para la operaci n en la pared Para mayor comodidad y eficien inspecci n y servicio cia instale el calentador En el lugar m s fr o de la habitaci n COLOCACI N DEL CALENTADOR EN LA PARED Soporte de montaje Desmontaje del panel anterior del El soporte de montaje se encuentra en el pa calentador nel posterior del calentador consulte la Figura 1 Quite los dos tornillos cerca de esquinas 5 Se coloc con cinta en ese lugar para el inferior del panel frontal inferior transporte Retire el soporte de montaje del 2 Tire hacia abajo del avance de panel panel posterior frontal inferior y a continuaci n abajo consulta la figura 6 Soporte de montaje Figura 5
94. s pressure switch See instructions below Pressure Switch When using natural gas NG there is a pressure switch that acts to turn off the gas flow to the pilot if the inlet pressure exceeds 9 WC This is to prevent the operation of the unit on the wrong gas propane LP If your natural gas supply exceeds 9 WC the unit will not operate Either contact your gas supplier to check and adjust the inlet pressure or a qualified service technician can bypass the pressure switch Before attempting to bypass the pressure Switch make sure the type of gas being used is correct Check to make sure the connection fitting is in the correct inlet on the regulator Refer to Connecting to Gas Supply page 15 Only a qualified installer should bypass the pressure switch To bypass the pressure Switch locate the set screw on the regulator Use a small flat bladed screw driver to turn the set screw counterclockwise 2 turns This will bypass the pressure switch function 24 www sureheat com The entire gas delivery piping including con nections inside the heater should be leak tested by the qualified installer After leak testing the qualified installer should light the appliance Refer to the correct flame pattern as illustrated on page 22 AII flame patterns should be safely inside the product If for any reason they are not stop use ofthe appliance and call for repairs Pressure Switch Set Screw Figure 29 Gas Regulator Pressur
95. t supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 of water If you do not reduce incom ing gas pressure heater regulator damage could occur Install external regulator with Ground 3 8 NPT the vent pointing down as shown in Figure 16 Pointing the vent down protects it from freezing rain or sleet Install sediment trap in supply line as shown in Figure 15 Place sediment trap where it is within reach for cleaning Place sediment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contami nants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly Joint Union Pipe Nipple ie with Equipment Propane LP ann Tee Joint Shutof Valve Supply Tank Reducer Natural Gas Test Gauge Bushing to From Gas Connection 1 8 NPT Meter 4 W C 118 NPT a Plug 224 Propane LP From External Tee Joint Regulator 11 W C to 14 W C Pressure Sediment Pipe Nipple Trap 3 Minimum Gap 8 Cd Figure 15 Gas Connection Purchase the optional CSA design certified equipment shutoff valve from your dealer Figure 16 External Regulator with Vent Pointing Down CHECKING GAS CONNECTIONS WARNING Testall gas piping an
96. tada por parte del fabricante sin fines de reventa 34 www sureheat com 200211 01A SEGURIDAD IMPORTANTE Leaeste manual del propietario cuidadosa y completa menteantes de intentar ensamblar operar o dar servicio a este calen tador El uso inadecuado de este calentador puede causar da ios a la propiedad lesiones graves o la muerte por quemaduras incendio explosi n electrocuci n e intoxi caci n con mon xido de carbono No seguir estas instrucciones anula la garant a La instalaci n y reparaci n de este producto deben estar a cargo s lo de personal calificado para la instalaci n una empresa de ser vicio o el proveedor de gas local ADVERTENCIA Mantenga el rea limpia y libre de materiales combustibles gasolina y otros vapores y l quidos inflamables ADVERTENCIA Este dispo sitivo se puede utilizar con gas propano o gas natural Se env a desde la f brica ajustado para su uso con gas propano Este aparato est disenado para usarse nicamente con el tipo de gas indicado en la placa de clasificaci n Este aparato no se puede convertir para que utilice otro tipo de gas Intoxicaci n con mon xido de carbono los s ntomas iniciales de la intoxicaci n con mon xido de carbono son semejantes a los de la gripe con dolores de cabeza mareos ylo n usea Si usted presenta estos s ntomas es posible que el calentador no est funcio 200211 01A www sureheat com n
97. tador continua apagando se deber ser revisado por personal calificado No haga funcionar el calentador Donde se utilicen o almacenen l quidos o vapores inflamables En condiciones con mucho polvo Apague el calentador antes de usar puli dores de muebles ceras limpiadores de alfombras o productos parecidos Si se calientan los vapores que se despren den de estos productos pueden producir un residuo de polvo blanco dentro de la caja del calentador o en las paredes y los muebles adyacentes BWH10NLMC s lo para el modelo siempre ejecuci n calefactor con mando de control al piloto IGN baja 5 o alta 1 bloqueado posiciones Nunca esta blezca perilla de control entre posiciones bloqueadas Pueden resultar mala com busti n y mayores niveles de mon xido de carbono No use este calentador si alguna de sus partes estuvo sumergida en agua Llame inmediatamente a un t cnico de servicio para que inspeccione el calentador y para que remplace las piezas del sistema de control o los controles de gas que hayan estado sumergidos en agua Apague y desconecte el calentador d jelo enfriar antes de cualquier reparaci n S lo un t cnico calificado debe realizar el mantenimiento o reparar el calentador Hacer funcionar el calentador a alturas superiores a 1 371 m 4 500 pies puede ocasionar que el piloto se apague Para evitar problemas de rendimiento en los modelos de gas propano LP no use tanques de gas propano LP de menos d
98. terior Perilla de control Bot n de encendido Rejilla Quemador Gabinete del calentador Figura 1 Calentador de gas sin ventilaci n DESEMPAQUE 1 Saque el calentador de la caja 2 Retire todo el empaque de protecci n que se agreg al calentador para su env o 38 www sureheat com 3 Revise el calentador para ver si hay alg n dafio debido al transporte Si el calenta dor est informe de inmediato al distribuidor donde lo compr 200211 01A VAPOR DE AGUA UN PRODUCTO DERIVADO DE LOS CALENTADORES DE HABITACI N SIN VENTILACI N EI vapor de agua es un producto derivado de la combusti n del gas Un calentador de habitaci n sin ventilaci n produce aproxima damente 29 57 ml 1 onza de agua por cada 1 000 BTU 0 29 kW de entrada de gas por hora Los calentadores de habitaci n sin ven tilaci n son recomendables como calefacci n suplementaria una habitaci n m s que como fuente principal de calefacci n una casa entera En la mayor a de las aplicaciones de calefacci n suplementaria el vapor de agua no constituye un problema En la mayor a de las aplicaciones el vapor de agua contribuye a la baja humedad de la atm sfera que se experimenta en climas fr os Los siguientes pasos asegurar n que el vapor de agua no se convierta en un problema 1 Aseg rese de que el calentador tenga el tama o adecuado para la aplicaci n incluidas la combusti n y la circulaci n ad
99. tion Removing Front Panel of Heater 1 Remove two screws near bottom corners of lower front panel 2 Pull bottom of lower front panel forward then down see Figure 6 Figure 6 Removing Front Panel Of Heater Methods For Attaching Mounting Bracket To Wall Use only the last hole on each end of mount ing bracket to attach bracket to wall Attach mounting bracket to a wall only in one of two ways 10 www sureheat com 1 Attaching to wall stud This method pro vides the strongest hold Insert mounting screws through mounting bracket and into wall studs 2 Attaching to wall anchor This method allows you to attach mounting bracket to hollow walls wall areas between studs or to solid walls concrete or masonry Decide which method better suits your needs Either method will provide a secure hold for the mounting bracket Marking Screw Locations 1 Tape mounting bracket to wall where heater will be located Make sure mount ing bracket is level WARNING Maintain minimum clearances shown in Figure 4 page 9 can provide greater clearances from floor and join ing wall 2 Mark screw locations on wall see Figure 7 page 11 Note Mark only last hole on each end of mounting bracket Insert mounting screws through these holes only 3 Remove tape and mounting bracket from wall Attaching Mounting Bracket To Wall Note Wall anchors mounting screws and spacers are in hardware packag
100. tions of Do not run heater 4 500 feet could cause pilot outage Where flammable liquids or vapors are 12 To prevent performance problems do used or stored not use propane LP fuel tank of less than Under dusty conditions 100 Ibs capacity Before using furniture polish wax carpet cleaner or similar products turn heater off SPECIFICATIONS i BTU available Ignition MODEL BWH10NLMC BWH30NLTE 10 000 Electric Piezo 30 000 Electric Piezo Gas Type Using Natural Gas Using Natural Gas Pressure Regulator Setting 4 W C 4 W C Inlet Gas Pressure Maximum 9 Maximum 9 inches of water Minimum 5 Minimum 5 Gas Type Using Propane Gas Using Propane Gas Pressure Regulator Setting 9 W C 9 W C Inlet Gas Pressure Maximum 14 Maximum 14 inches of water Minimum 11 Minimum 11 Heater Dimensions HxWxD 19 A x 14 1 8 x 6 23 1 2 x 26 Js x 8 Carton Dimensions HxWxD Heater Weight Shipping Weight 22 x16 2 4 x 8 1 14 6 Ibs 17 6 lbs 25 3 x 28 112 x 9 1 4 31 Ibs Electrical Requirement for Blower Kit if equipped Voltage 120 VAC 60 Hz www sureheat com 200211 01A QUALIFIED INSTALLING AGENCY Only a qualified agency should install and replace gas piping gas utilization equipment or accessories and repair and equipment ser vicing The term qualified agency means any individual firm corporation or company that either
101. trol no aparecer cuando se libera p ngase en contacto con un t cnico de servicio calificado o proveedor de gas para las reparaciones Nota si el piloto se apaga repita los pasos 3 al 7 Este calentador tiene un sistema de bloqueo de seguridad Espere un 1 minuto antes de encender el piloto nue vamente 8 Gire la perilla de control en sentido contrario al de las manecillas del reloj FK hasta la temperatura deseada El quemador principal deber encenderse Los calentadores con control ma La perilla de control se puede colocar en cualquier nivel de calor entre 1 y 5 AA PRECAUCI N no intente ajustar los niveles de calefac ci n por medio de la v lvula de cierre del equipo MM FUNCIONAMIENTO DEL CONTROL CON TERMOSTATO MN El control termost tico utilizado en este modelo se diferencia de los termostatos est ndar Se establece termostatos est ndar a una tempera tura espec fica como por ejemplo 72 grados El termostato utilizado en este calentador detecta la temperatura ambiente Aveces el ambiente puede superar la temperatura establecida Si es as el quemador se apagar El quemador volver a encenderse cuando la temperatura ambiente des ciende por debajo de la temperatura programada La perilla de control se puede ajustar a cualquier nivel de confort entre baja 1 y HIGH 5 C MO CERRAR EL SUMINISTRO DE GAS AL APARATO MN C mo apagar el calentador Gire la perilla de control en direcci
102. urn control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out any air Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you do not smell gas go to the next step 5 Turn control knob counterclockwise to the PILOT position Press in control knob for five 5 seconds see Figure 20 Note The first time that the heater is oper ated after connecting the gas supply the control knob should be pressed for about thirty 30 seconds This will allow air to bleed from the gas system If pilot does not stay lit referto Troubleshooting pages 24 though 27 Also contact a qualified service technician or gas supplier for repairs Until repairs are made light pilot with match e If control knob does not pop up when released contact a qualified service technician or gas supplier for repairs 18 www sureheat com 6 With control knob pressed in push down and release ignitor button This will light pilot The pilot is attached to the front of burner The pilot can be seen through the grill If needed keep pressing ignitor button until pilot lights Note If pilot does not stay lit refer to Troubleshooting pages 24 though 27 Also contact a qualified service technician or gas supplier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure page 20 Keep control knob