1. 6 Parts or units which are replaced become the property of Sunpentown 7 The warranty applies for the use of the product in the USA 8 Warranty does not include freight charges This GUARANTEE is in addition to your Statutory Rights Please keep this warranty for your record DO NOT return it EQ SUNPENTOWN INTERNATIONAL INC
2. Owner s Manual Magic clean HEPA Air Cleaner with lonizer Model AC 3000 63 SUNPENTOWN INTERNATIONAL INC INTRODUCTION Congratulations on your choice of the MAGIC CLEAN HEPA Air Cleaner with lonizer We highly recommend that you operate the Air Cleaner 24 hours a day because indoor air can be quickly contaminated by activity or objects in a room and infiltration of outside air Air cleaners are much more effective in rooms where all doors and windows are closed STRUCTURE Main Body HEPA amp Carbon Filter Package Front Grill Your Air Cleaner was thoroughly inspected and tested at the factory prior to packaging Visually inspect it upon removal from its packaging Return the unit if it shows any signs of damage or mishandling WARNING To avoid fire or shock hazard the Air Cleaner should ONLY be plugged into a polarized 120 Volt AC outlet IMPORTANT SAFETY INSTRUCTIONS Please read all instructions before using this product save these instructions for easy reference When using electrical appliances basic precautions should always be followed to reduce breakage risk of fire electric shock and injury to persons including the following Do not use air cleaner outdoors Do not use air cleaner too close to the wall to avoid the wall getting dirty Never operate air cleaner without the filter properly installed Permanent motor damage could result Never use air cleaner unless it is fully
3. STORAGE 1 Remove filter from the unit 2 Wrap the filter in an airtight plastic bag or plastic wrap Be sure that the filter is totally sealed to protect it from its storage environment To restore the Air Cleaner to service 1 Unwrap the filter 2 Install filter in the air cleaner See Filter Replacement section for proper installation TECHNICAL SPECIFICATIONS Length Width Height Weight input voltage REPLACEMENT PARTS Replacement Filter AC 3000F CUSTOMER ASSISTANCE LINE If you experience a problem please see the warranty for information Please DO NOT attempt to repair this unit yourself Doing so will void your warranty and could cause damage to the air cleaner or personal injury to yourself If you have any questions concerning this appliance please call 1 626 330 8888 YOUR GUARANTEE lf this product is found to be faulty as a result of faulty materials or workmanship within 1 year from date of purchase it will be repaired or replaced free of charge This guarantee is subject to the following terms 1 Sunpentown must be notified of the fault 2 Proof of purchase must be presented to Sunpentown s nominated representative 3 The warranty will be void if the product is modified misused or repaired by an unauthorized person 4 The guarantee after repair or replacement will not be extended beyond the original one year period 5 All replacement parts or units will be new or reconditioned
4. assembled Do not use air cleaner where combustible gases or vapors are present Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the air cleaner Do not block air outlets or intakes The air cleaner has a polarized plug one blade is wider than the other To reduce risk of shock this plug is intended to fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug DO NOT attempt to defeat this safety feature The Air Cleaner should ONLY be plugged into a 120 Volt AC outlet A loose fit between the plug and the AC outlet receptacle may cause overheating and a distortion of the plug Contact a qualified electrician to replace loose or worn receptacles Unplug from wall outlet before servicing OPERATION Room air is drawn into the Air Cleaner through the Front Grill and passes through the filter The filtered air is released from the top of the unit and is dispersed into the room The air cleaner has two operating speed with a slider switch Besides the lonizer function can obviously increase the efficiency in attracting dusts and restrain the propagating of the bacteria FILTER REPLACEMENT The filter is specially designed for easy replacement to ensure maximum performance THE FILTER shall be replaced every 6 six months depending on usage The replacement filter item number is AC 3000F The efficie
5. ncy and air volume output will begin to decrease dramatically when the filter needs to be changed The steps of replacing the filter are as below 1 Turn the Air Cleaner OFF and unplug the unit from the power outlet 2 Carefully lay unit down on a flat surface with the Front Grill facing up 3 Using finger pressure in the two notches located on top of the front grill pull front grill out and away 4 Remove and discard the old filter 5 Remove any protective plastic wrapping and packaging from the new filter 6 Set new filter into the air cleaner 7 Install the Front Grill by placing the top edge of the grill near the top of the air cleaner lining up the grill tabs with the air cleaner slots 8 Snap Front Grill into place by pushing down carefully near the bottom edges of the Front Grill 9 The Air Cleaner is now ready for operation FILTER CHANGE CALENDAR The Filter Change Calendar on the top panel can help you remember to change filter Set the month when replacing the filter CLEANING THE UNIT 1 Turn Air Cleaner OFF and unplug from power outlet 2 Clean unit with a moistened soft cloth only DO NOT pour or splash water on the unit or use any abrasive type cleaner on it Clean all external surfaces especially the air intake grilles and air outlet 3 DO NOT attempt to clean the filter itis NOT washable and washing will damage it 4 Reposition Air Cleaner plug into power outlet and turn ON