Home

SPT TN-09E Use and Care Manual

image

Contents

1. 2m eee TM TECHN For Models TN O9E TN 12E PORTABLE Air Conditioner is important that you ese instructions befor ing your new purche nd we strongly recom hat you keep them i lace for futur HE le We m Orel ELO Energy Saving Tips T N 09E TN 12E w Accessories Mounting the Unit g Mounting the Exhaust Pipe s s ss sscssssessssssscecsstos s eso cessessseescseseesesesees Installation of the Carbon Filter OPERATION ELECTRONIC CONTROL MODE LG ssssssssssssessessssesessstreeseceeessssnsstesstenseees 7 Control Panel Turning On Off Setting Mode Function Auto Mode Setting the Temperature Setting Fan Speed iarere aniar AEA A nine rie PETISE Setting the Timer Regulating Airflow Direction By the Draining into a Container By Water Tube continuous drainage Cleaning the Housing Cleaning the Filter End of Season Storage Storing the Power Cord TROUBLESHOOTING YOUR GUARANTEE scssssassecesdssosisetessdasicenabtndeuconecisdasenesiqasitledoccdcaieeudaaaaieassesvavchsncdteseaidstiniels gt Thank You Thank you for choosing the portable air conditioner from Technitrend a leading brand in indoor air treatment We would like you to enjoy the many benefits this unit offers so please take the time to read this manual carefully and take full advantage of the many advanced features that your Technitrend Air Conditioner offers you Technitrend has specialized in complete ind
2. To adjust the height of the slider kit align the small openings on the side when the desired height is reached insert a small scre w not supplied through one of the opening Extend one end of the exhaust hose a nd insert it into the Round Connector Tighten hose by turning clockwise Attach the Adapter to the other end of the hose Tighten by turning Adapterclockwise Attach the Adapter to the back of the unit Slide window patio door close a gainst the slider kit Make sure the exhaust hose has no kinks or sharp bends The be st distance betwee n the machine and window or wall is 31 39 inches 2 Using the Through the Wall L Wall or Window Window Slider Kit Round Connector Outward adaptor o DD 7 FIG 7 FIG 6 e Make a hole 5 in diameter in the wall to fit the supplied round connector e Fit the hose directly to the round connector e When the hole is not in use use the cap for the round connector to cover the hole Installation Mounting the exhaust pipe e The supplied exhaust hose can be extended from 1 foot to 5 feet for iki mounting It is recommended that you use the shortest possible length of hose FIGS e Take care to prevent any kink or bend in the middle of the exhaust hose as this will trap hot exhaust air which will radiate back into the room WARNING The length of the exhaust pipe is specially designe
3. to select the required working mode Automatic Cooling Fan lhe green indicator illustrating your selected mode lights up It is recommended to select Cooling and set your desired temperature as the Auto mode has a preset temperature please see below that cannot be changed The indicators of the functions in progress come on at the same time e g Cool and Lo Cooling mode with Low fan speed Auto Mode When this mode is selected the unit is preset to the following temperature settings and unit will only start to e Cool when room temperature is higher than 75 F If room temperature is between 68 F and 75 E unit will stay in Fan mode Again when in Auto Mode the temperature settings cannot be changed Setting the Temperature in Cooling The display window s default is to display the ambient room temperature The green indicator light under RT is on RT Room Temperature lo set your desired temperature press the Temperature Up or Down buttons ranging from 62 F to 90 F Each press will increase or decrease your set temperature by 1 F When pressing the temperature up or down buttons the window will change to display your set temperature At this time the green indicator will light under ST Set Temperature Once the temperature up or down buttons is released the window will return to displaying the ambient temperature after a second Note When unit is in the following modes Auto or Cool the compressor will cool the room to reach
4. d according to the specification of this product Do not replace or extend it with your own hose as this could cause the unit to malfunction Installation of the Carbon Filter Remove the filter frame from the unit Separate the filter from the filter frame wn Remove the active carbon filter from its plastic bag 4 Insert the active carbon filter into the filter frame 5 Fix the filter by reassembling the fixer onto the filter frame 6 Re fit the filter frame inside the unit It is recommended to replace the carbon filter every 3 to 6 months Operation Electronic Control Models Control Panel 1 3 7X8 X6 X910 18 i sans 1 I O power button tt T 2 Compressor operation indicator Cus Green 4 3 Speed ventilation button 2 go Jl pe 4 Low ventilation indicator E T a 5 _ High ventilation indicator r Eme L 6 Mode function option button D AADO OE 66 4 G Automatic mode indicator 10 Heating mode indicator not applicable 14 Temperature up button j E aac 11 Timer button 15 jai wal Remote Control 12 Timer operation indicator 16 Display window 13 Temperature down button 17 Room temperature indicator Turning ON OFF 18 Set temperature indicator Press the ON OFF selector the unit will start to work at its last setting Setting Mode Function Press the MODE button
5. d or damage to the compressor Damage caused by improper maintenance will void the warranty Cleaning the Filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse them thoroughly under running water no hotter than 104 F Do not wet the activated carbon filter remove from frame before washing Dry thoroughly before replacing Notice Never operate the unit without the filters End of Season Storage Unplug the unit Drain the condensed water COMPLETELY please refer to page 9 Clean or change the filter On a warm day turn the unit to fan mode for a couple of hburs so that the inside can dry out completely It is recommended that the unit be put back into its original carton for storage Do not stack heavy objects on top of the unit Storing The Power Cord When the unit is not in use please store the power cord away shown in Figure 3 Fig 3 10 Troubleshooting The unit doesn t run or eIs the machine plugged in els the mains power supply on eIs the room temperature in the working range els the unit in auto mode Electronic Model set to cool or heat and set to proper temperature only runs in fan mode The unit seems to do little els there direct sunshine Please close the curtains or blinds e Are too many windows or doors open e Are there too many people in the room Is there something in the room producing lots of heat The unit
6. etting e Do not sit or place objects on the unit e Do not touch the unit with wet damp hands or when standing barefoot e Avoid all contact with chemical based materials The filter must be used with the product at all times When removing for i i a 0 cleaning always disconnect the unit from the mains first fio He 000 Turn off the appliance when not in use We Op e At the end of each season all water must be drained and the unit and i 1 oo filters cleaned before storage Drainage of the water container is required before moving the unit or putting it into storage e If the electric socket is different from the plug provided have a professionally qualified electrician replace the plug with a suitable one Avoid the use of adaptor plugs multiple sockets and or extension leads if their use is necessary ensure that they conform to the current safety regulations e Do not pull the supply cable or place it near a source of heat always unroll it completely to avoid the possibility of dangerous overheating e Ifthe supply cord is damaged it must be replaced by the service agent or a similarly qualified person THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED Seococoonn gt osoononnnn oao208000m o0000000m oopo00000N oopoonoon oooonnooon 1 Control Panel 5 Air Filter 2 Cooling Air Outlet 6 Air Inlet 3 Handle 7 Ex
7. haust Air Outlet 4 Castors 8 Cord Hanger 9 Water Stopper Rubber Plug Inside Accessories 10 Adaptor for insertion over the hose and into the back of the air conditioner G Y 11 Round Connector to be used between Dns hose and window kit or between hose and 7 wall 12 Exhaust Hose l Length 14 60 Diameter 4 75 13 Plastic Sliderkit for filling the open window space and with a hole for connection to thexhaust hose Dimension 7 x24 5 x0 75 Plastic Slider kit for filling the open window space Dimension 7 x24 5 x0 75 14 Cap for Round Connector 15 Drain tube 16 Carbon filter 17 Remote Control Installation Mounting the unit This unit is a portable air conditioner It can be moved from room to room so that the cooling can follow you anywhere Fitting the exhaust hose is easy through a window or wall Please refer to either of the following ways 1 Using the Plastic slider kit Window Slider Kit Round Connector FIG 5 Remove the 4 scre ws around the circular opening on the plastic kit Insert the round connector through the circular opening the lip of the round connector should be on the flat side of the slider kit Align the screw openings and replace the 4 Screws Determine how many sections of the slider kit you window sliding door requires the sli der kit inside the window door frame with flat side of round connector acing out
8. oor environment control manufacturing world class air conditioners dehumidifiers and air purifiers with innovative technology In designing these advanced products we have listened carefully to our customers and have passed their views on to our research and development laboratories We wish you many years of enjoyable use After reading this manual please keep it in a safe place for future reference Energy Saving Tips Please use the unit in the recommended room size Refer to SPECIFICATIONS Do not locate the air conditioner where furniture or other objects can obstruct the airflow e Keep blinds curtains closed during the sunniest part of the day Close the fireplace damper and floor or wall grills so that cool air does not escape through the chimney or ductwork Keep the filters clean Set the unit to maximum cooling and high speed fan initially then adjust the unit to a comfortable setting NOTE It is recommended to turn on the air conditioner when the room temperature is around 75 F Do not wait until the room is excessively hot Specifications TN 09E TN 12E m 9 000BTU hr 12 000BTU hr N A N A Model Number Cooling Capacity Heating Capacity 1 2 Power Consumption 873W 8 15A 965W 8 5A Humidity Removal Capacity 50 pts day 65 pts day Recommended Room Size 250 sq ft 400 sq ft rs Powe
9. ork continuously By pressing the timer button but without turning on the unit you j AEN can PRE SET the time for the machine to work For example if you E3 press the timer to 2 the unit will come on automatically after 2 hours All the above functions can also be performed with the supplied remote control This remote control requires 2 AAA batteries to operate J Regulating the airflow direction Turn the roller on the air vent to control the airflow direction from the vertical louvers Notice e To prolong the unit s life it will start 3 minutes after the unit was switched on After switching off please wait at least 3 minutes before switching it on again e The cooling system will switch off if the room temperature is lower than set The fan however keeps working at the set level If the ambient temperature rises above the chosen temperature 1 F the cooling will resume MEALA aA Always unplug the unit from the mains before beginning the cleaning Cleaning the Housing Use a soft damp cloth to wipe the body clean Never use strong chemicals oil based products detergents chemically treated cloths or other cleaning solutions These could possibly damage the cabinet Important Clean the exhaust air intake area located on the side near bottom with a vacuum to remove dust accumulation Excessive dust may cause a decrease in performance an
10. r Supply 115V 60Hz 1 Phase 115V 60Hz 1 Phase Compressor Rotary Rotary fn d J Refrigerant R 22 18 3 oz R 22 17 3 oz Fan Speed 2 2 Timer 1 12hours 1 12hours Thermostat 62 F 90 F 62 F 90 F Net Weight 63 lbs 65 lbs Dimensions 17 W x 16 D x 30 H 17 W x 16 D x 30 H Working Temperature Cooling 62 F to 110 F Cooling 62 F to 110 F REMARKS 1 The data may vary please refer to the rating label on the back on the back of the unit 2 The above conditions are measured at Cooling Indoor RT 81 F RH 60 Heating Indoor RT 68 F RH 60 Uninsulated rooms such as sunrooms garages or attics should be less than 250 sq ft Before Use Important e Transport the unit in an upright position only or leave it in an upright position for at least 2 hours before first use e Always place the unit on an even surface Figure 1 e Make sure the unit is connected to a correctly grounded power supply refer to the rating label located at the back of the unit e An opening in a window or wall is required to accommodate the exhaust hose kit supplied to expel the warm air Do not cover or obstruct the appliance inlet or outlet grilles Figure 2 To avoid the risk of shock the product should never be used in bathrooms shower rooms or in any other steamy or wet areas e The unit will cool when the room temperature is between 62 F and 110 depending on the thermostat s
11. seems to do nothing els the dust filter dirty els the air intake or outlet blocked up els the temperature within the selected temperature 5 F els the water tank full Drain the water The room being cooled should have proper insulation If the unit is used in UN INSULATED rooms such as Sunrooms Garages or Attics ideal The room is not cold enough cooling might not be attained Too noisy els the machine positioned unevenly so as to create vibration els the floor underneath the machine uneven The compressor doesn t run The overheat protection feature on the compressor might be on If this occurs wait for the temperature of the unit to drop els the water container full Does it need draining NEVER TRY TO REPAIR OR DISMANTLE THE UNIT YOURSELF REPLACEMENT FILTERS To purchase Replacement Filters for this unit contact SPT usa at 1 800 330 0388 and request model number TN 12F amp TN O9F If this product is defective or not working properly please DO NOT return to your retail store Please contact us directly for any Service or Technical Assistance at 1 800 330 0388 11 TECHNIFRERS Portable Air Conditioner Your Guarantee If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase it will be repaired or replaced free of charge This guarantee is subject to the following terms JECHNTRENZ must be notified of the faul
12. t Proof of purchase must be presented to TECHNITREAS nominated representative The warranty will be void if the product is modified misused or repaired by an unauthorized person The guarantee after repair or replacement will not be extended beyond the original one year period All replacement parts or units will be new or reconditioned Parts or units which are replaced become the property of TECHNIFRERD The warranty applies to the use of this product in the United States Warranty does not include freight charges This GUARANTEE is in addition to your Statutory Rights TECHNITREND By SUNPENTOWN 1 800 330 0388 www spt usa com Dear Customer Please keep this warranty for your record DO NOT return it 12
13. the set temperature Once the ambient temperature has reached the set temperature the compressor will stop and unit will run in Fan mode lo conserve energy the compressor will not start immediately after a couple degrees increase or decrease In auto mode it will wait for a 5 F as an allowance In cooling mode it will wait fora 1 F as an allowance In Cooling Mode with a set temperature of 70 F When compressor first stops after reaching 70 F unit will auto switch to Fan Compressor will start cooling again when ambient temperature increases to 71 F or above In Auto Mode with preset temperature and 75 F for cool Compressor will start cooling again when ambient temperature reaches above 80 F Operation Electronic Control Models Setting The Fan Speed Press the SPEED button to choose the fan speed you require high or low The indicator of high or low fan will light up at the same time If the unit is in AUTO mode it will select the fan speed automatically according to the ambient temperature the related indicators cool fan or heat will light up at this time the fan speed switch is invalid Setting the Timer Press the TIMER button to set the operating hours you desire 1 to 12 hours the timer indicator will light up When the set time has elapsed the machine will turn off automatically The display window will show the hour s you set as you press the TIMER button If the timer button is not pressed the unit will w