Home
LG Electronics LT1235CER Use and Care Manual
Contents
1. Remote 7 Cool F1 LOW F F2 MED Energy Clean zl O Saver Filter En Filter Reset 2 an gt TEMP WJ wwe ry imer 4 FAN MODE TIMER SPEED POWER 4 3 2 D 1 POWER Operation starts when this button is pressed and stops when you press the button again 2 FAN SPEED SELECTOR Use to set the fan speed to Low F1 MED F2 High F3 3 ON OFF TIMER Delay ON when the air conditioner is off it can be set to automatically turn on from 1 to 24 hours at its previous mode and fan settings Delay OFF when the air conditioner is on it can be set to automatically turn off from 1 to 24 hours 4 OPERATION MODE SELECTOR Push the MODE button to rotate between Energy Saver Cool Fan Dry Energy Saver The fan stops when the compressor stops cooling Approximately every 3 minutes the fan will turn on and check the room air temperature if cooling is needed Cool Compressor runs and cools the room Use the A V and FAN buttons to set the desired temperature and circulation fan speed Fan Fan circulates air but compressor does not run Use the FAN button to set the desired fan speed Dry Dry mode is used to remove humidity from the room without additional cooling Once the set temperature is reached the compressor and circulation fan turns off Fan speed is pre set and cannot be adjusted 18 Room Air Conditioner 5 TEMPERATURE CONTROL The thermostat monitors room temperature to maintain
2. No se suba a la unidad interior exterior ni coloque objetos sobre la misma aparato o al caerse los objetos que haya colocado Tenga cuidado para no tocar los bordes puntiagudos al instalar ocasiones Podr a ocasionar lesiones salud Si entra l quido de las pilas en contacto con la piel o la ropa l vela inmediatamente con agua No utilice el control remoto si las pilas tienen fugas Los productos qu micos de las pilas podr an e causar quemaduras u otros perjuicios a la salud _ i No bloquee la entrada ni la salida del flujo de aire Inserte siempre el filtro correctamente L mpielo cada dos semanas acondicionado e Puede lesionarse al caerse del El funcionamiento sin filtros puede provocar fallos Evite un enfriamiento excesivo y ventile en Utilice un pa o suave para limpiar No utilice cera disolventes o detergentes fuertes Puede causar una aver a en el e La apariencia del aparato de aire aparato acondicionado puede deteriorar cambiar el color o desarrollar flujos en las superficies No beba el agua que drena el aparato de aire e Contiene elementos de contenci n y hacer que se enferme No introduzca la mano ni barras en la entrada o salida del aire durante el funcionamiento del aparato e De lo contrario podr a da ar su De lo contrario podr an ocurrir lesiones personales Si el l quido de las pilas alcanzara su boca cepille sus dientes
3. LG Life s Good HSISNaA TONWdS4 OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your air conditioner and retain it for future reference TYPE WINDOW MODELS LT1035CER LT1235CER P NO MFL68743902 www lgappliances com Safety Precautions Before Operation 7 Introduction eet 8 Electrical Safety 9 Installation eee 11 Operating Instructions 18 Maintenance and Service 21 2 Room Air Conditioner _ FOR YOUR RECORDS Write the model and serial numbers here Model Serial You can find them on a label on the side of each unit Dealer s Name Date Purchased E Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues yo READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION e Contact the authorized service technician for repair or maintenance of this unit e Contact the installer for installation of this unit The air conditioner is not intended f
4. LG Customer Information Center 1 800 243 0000 Register your product Online LG ELECTRONICS INC 1000 Sylvan Ave Englewood Cliffs NJ 07632 www Igappliances com
5. Los da os o aver as causados por accidentes plagas e insectos rayos viento fuego inundaciones o actos de Dios 5 Los da os o fallos ocasionados por el mal uso abuso instalaci n inadecuada reparaci n o mantenimiento Se considera reparaci n inadecuada aquella en que se hayan utilizado piezas no aprobadas o especificadas por LG 6 Los da os 0 aver as causados por modificaciones no autorizadas o alteraciones del producto 7 Los da os o aver as causados por la utilizaci n de una corriente el ctrica tensi n o c digo de plomer a incorrectos 8 Da os est ticos incluyendo ara azos abolladuras desportilladuras u otros da os en el acabado del producto a menos que dichos da os sean el resultado de defectos en los materiales o mano de obra y se informe a LG en el plazo de siete d as naturales 7 a partir de la fecha de entrega 9 Los da os o la p rdida de componentes de cualquier producto cuya caja haya sido abierta haya sido objeto de un descuento o se haya restaurado 10 Los productos cuyos n meros de serie de f brica originales hayan sido quitados borrados o cambiados de ninguna manera 11 Las reparaciones cuando el producto se utiliza para cualquier cosa fuera de lo normal y del uso dom stico habitual por ejemplo su alquiler uso comercial en oficinas o en instalaciones de ocio o en contra de la instrucciones que se indican en el manual del propietario 12 La extracci n y reinstalaci n del prod
6. Otherwise it may electrical electric shock accident shock and failure No correlation between fan Turn off the power and _ Unplug the unit when not usage and oxygen depletion ocr first when cleansing using it for a long time e unit e An oxygen shortage may occur Since the fan rotates at high e Prevent accidental startup and speed during operation it may the possibility of injury cause injury gt a7 nr VY 4 Room Air Conditioner Safety Precautions Do not operate or stop the Do not damage or use an Do not operate with wet unit by inserting or pulling unspecified power cord hands or in damp out the power plug environment e It will cause electric shock or fire It will cause electric shock or fire It will cause electric shock due to heat generation NEC Hold the plug by the head When gas leaks open the Never touch the metal parts when taking it out window for ventilation of the unit when removing before operating the unit the filter e It may cause electric shock and Otherwise it may cause e They are sharp and may cause damage explosion and a fire injury For inner cleaning contact an Authorized Service Center or a dealer Do not use harsh detergent that causes corrosion or damage on the unit Harsh detergent may also cause failure of product fire or electric shock CAUTION E Installation Install the product so the exhaust and noise Follow installation instructions exactly are
7. 2 Size options 2 Size options 3 m NAME OF PARTS PLASTIC GRILLE VERTICAL INSULATION STRIP AROUND INSULATION STRIPS HORIZONTAL INSULATION STRIP SUPPORT BLOCK BAFFLE TRIM FRAME SHIM 2 DD po PO ld lt PLASTIC NUTS AND WASHER SCREWS OGS EE A CAUTION To avoid risk of personal injury property damage or product damage due to the weight of this device and sharp edges that may be exposed e Air conditioners covered in this manual pose an excessive weight hazard Two or more people are needed to move and install the unit To prevent injury or strain use proper lifting and carrying techniques when moving unit e Carefully inspect location where air conditioner will be installed Be sure it will support the weight of the unit over an extended period of time e Handle air conditioner with care Wear protective gloves whenever lifting or carrying the unit AVOID the sharp metal fins of front and rear coils e Make sure air conditioner does not fall during installation REQUIRED TOOLS e Tight Fitting gloves e Standard screwdriver e Phillips screwdriver e Pliers e Sharp knife e 3 8 inch open end wrench or adjustable wrench e 1 4 inch hex socket and ratchet Tape measure e Electric drill e 1 4 inch drill bit Owner s Manual 11 Installation INSTALLATION A CAUTION We strongly recommend the remo
8. DE PODER Limpieza El filtro de aire debe ser controlado al menos dos veces al mes para ver si es necesaria su limpieza Las part culas atrapadas en el filtro pueden acumularse y bloquear el flujo del aire Esto reduce la capacidad de refrigeraci n y tambi n causa una acumulaci n de hielo en los sepentines de enfriamiento Si el filtro se inutiliza o se da a debe ser reemplazado inmediatamente Filtros de repuesto est n disponibles en la tienda donde lo compr el representante y en los centros de servicios autorizados 1 Abra la rejilla de entrada hacia abajo tirando de la parte superior de la rejilla de entrada 2 Quite el filtro de aire de la rejilla frontal tirando ligeramente del filtro de aire 3 Lave el filtro usando agua tibia por debajo de 40 C 104 F 4 Sacuda suavemente el exceso de agua del filtro Reemplace el filtro Como agregar la rejilla frontal al La rejilla frontal puede quitarse para su limpieza o para comprobar el modelo y el n mero de serie Para su seguridad debe seguir el siguiente procedimiento para colocarla 1 Quite la parte superior de la rejilla frontal de 4 Ajuste los tornillos a trav s de la rejilla frontal la parte superior del gabinete en la placa de la caja de control 2 Empuje los extremos frontales de la rejilla 5 Cierre la rejilla de entrada hacia el gabinete a fin de insertar las pesta as de la rejilla frontal en el gabinete 3 Abra la rejilla de ent
9. Estancia La temperatura est demasiado baja Seleccione una temperatura m s alta demasiado fr a Si aparece CH en la pantalla por favor llame al 1 800 243 0000 Manual del Propietario 45 WARRANTY LG ROOM AIR CONDITIONER LIMITED WARRANTY USA WHAT THIS WARRANTY COVERS LG Electronics U S A Inc LG warrants your LG Room Air Conditioner product against defect in materials or workmanship under normal household use during the warranty period set forth below LG will at its option repair or replace the product This limited warranty is valid only to the original retail purchaser of the product is not assignable or transferrable to any subsequent purchaser or user and applies only when the product is purchased through an LG authorized dealer or distributor and used within the United States U S including U S Territories Note Replacement products and repair parts may be new or factory remanufactured and are warranted for the remaining portion of the original unit s warranty period or ninety 90 days whichever is longer Please retain dated receipt or delivery ticket as evidence of the Date of Purchase for proof of warranty you may be required to submit a copy to LG or authorized representative WARRANTY PERIOD 1 year from the Date of Purchase Any internal functional Parts and Labor HOW SERVICE IS HANDLED In Home Service In home service will be provided during the warranty period subject to avai
10. existente antes de instalar la unidad segun la lista Marca Dimensiones del soporte de pared pulgadas Ancho Altura Profundidad White Westinghouse Frigidaire 25 12 15 14 16 1712 Carrier Serie 52F General Electric Hotpoint 26 15 5 8 16 7 8 17 1 8 Whirlpool 25 7 8 16 1 2 623 Fedders Emerson 27 16 3 4 1 6 3 4 19 3 4 LGE 25 7 8 15 17 32 16 23 32 Emerson Fedders 26 3 4 15 3 4 15 Carrier Serie 51S 25 3 4 16 7 8 18 5 8 Friedrich 27 16 3 4 16 3 4 CONSEJO Todos los soporte de pared utilizados para montar el nuevo aire acondicionado deben estar en condiciones estructurales sanas y tener una rejilla posterior que se acople con seguridad al soporte de pared o una pesta a posterior que sirva como freno para el aire acondicionado a Desmonte el antiguo aire acondicionado del soporte de pared existente E Limpie el interior del soporte de pared existente No toque el sellado 4 El soporte de pared se estar firmemente sujeto a la pared antes de instalar el aire acondicionado Utilice los clavos o tornillos a trav s del soporte de pared si fuera necesario Vuelva a pintar el soporte de pared si fuera necesario B Prepare el soporte de pared para la instalaci n de la unidad Si usted piensa utilizar el soporte de pared existente y no es LGE utilice el procedimiento B C a continuaci n Procedimiento Marca Profundidad pulgadas A LGE 1
11. instalaci n Las tuercas est n instaladas en el interior del soporte de pared y est n presionando las perforaciones rectangulares de las pesta as posteriores oe Figure 5 Retire el envoltorio de la tira vertical de aislamiento 15 9 16 x 1 3 8 x 1 3 8 y unala a la parte interior derecha del soporte de pared seg n se muestra a continuaci n Retire el envoltorio de la tira de aislamiento envolvente de 67 1 8 x 1 3 8 x 25 32 y nala a la parte frontal interior del soporte de pared seg n se muestra a continuaci n Interior Exterior 917 6 Figure 6 Instalacion 4 Instale la nueva unidad en el soporte de pared B Para el montaje encaje la leng eta de cada pieza en la ranura de la otra pieza seg n se muestra a continuaci n Deslice la pieza sobre la parte frontal del aire acondicionado hasta que el ajuste sea rasante con el soporte de pared seg n se muestra a continuaci n Figure 7 A PRECAUCION e Los aires acondicionados tratados en este manual representan un peligro por peso excesivo Son necesarias dos o m s personas para desplazar e instalar la unidad Para evitar lesiones o esfuerzos excesivos utilice las t cnicas de levantamiento y desplazamiento apropiadas al mover la unidad e Manipule con cuidado el aire acondicionado tenga cuidado de evitar cortes de las aristas afiladas de metal de las bobinas frontal y posterior e
12. not trip or if the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician NOTICE Use Wall Receptacle A WARNING Never push the test button during operation Otherwise this plug can damaged Use 15 AMP time delay fuse or 15 AMP Do not remove modify or immerse circuit breaker this plug Standard 250V 3 wire groundin A A pecpiacia rated 16A 250 AE If this device trips the cause should be corrected before further use 44 WARNING 44 CAUTION USE OF EXTENSION CORDS The conductors inside this cord are RISK OF FIRE could cause serious injury or death peels by NEEDE DO NOT use an extension cord with this window Saag eben air conditioner Me oa are der a DO NOT use surge protectors or multi outlet eg aa S areal Se ie e damage Do not use this product in the adapters with this window air conditioner event the shields become exposed Avoid shock hazard This unit cannot be user serviced Do NOT open the tamper resistant sealed portion All warranties and performance will be voided This unit is not intended to be used as an ON OFF switch Owner s Manual 9 Electrical Safety Electrical Safety i IMPORTANT PLEASE READ CAREFULLY FOR THE USER S PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED The power cord of this appliance is equipped with a three prong grounding plug Use this with a standard three slot grounding wal
13. polarizaci n adecuada A PRECAUCION Adaptar la terminal del ground del adaptador a la cubierta de la pared con un tornillo no neutraliza el aparato a menos que la cubierta del tornillo sea de metal u no sea insolada y el receptor de pared este neutralizado a trav s del alambrado del la casa El cliente debe hacer verificar el circuito por un electricista calificado para asegurarse que el receptor esta debidamente neutralizado Desconecte el cord n de energ a del adaptador utilizado una mano en cada uno De lo contrario la terminal del adaptador puede romperse NO UTILICE el aparato con un enchufe roto B SITUACIONES EN LAS CUALES EL APARATO ES DESCONECTADO CON FRECUENCIA No utilice un adaptador en estas circunstancias Desconectar el cord n de energ a con frecuencia lo llevar al eventual rompimiento de la terminal de neutralizaci n La saluda de energ a de la pared debe ser reemplazada por una salida de tres patas neutralizada El Instalacion Retire los materiales de embalaje del soporte de pared de pared y la cinta del aire acondicionado REQUISITOS DE INSTALACI N Si utiliza un soporte de pared de pared ya existente deber medir sus dimensiones Instale el nuevo aire acondicionado seg n estas instrucciones de instalaci n para lograr el mejor funcionamiento Todos los soporte de pared de pared utilizados para montar el nuevo aire acondicionado deben estar en buenas condiciones estructurales y contar
14. pulgadas Manual del Propietario 33 Instalacion INSTALACION APRECAUCION Recomendamos encarecidamente que desmonte el viejo soporte de pared y la instalaci n de un nuevo soporte de pared LGE Si decide mantener el soporte de pared existente tendra que redireccionar las rejillas de ventilaci n en la parte posterior de la ilustraci n del soporte de pared Recomendamos el uso de alicates Si NO las redirecciona corre el riesgo de un rendimiento pobre o de aver as en el producto Estas no est n cubiertas bajo los t rminos de garant a de LGE e Escoja una ubicaci n que permita al aire acondicionado soplar hacia el rea que desee Una buena instalaci n prestando especial atenci n a la posici n correcta de la unidad reducir la necesidad de reparaciones ART CULOS EN EL HARDWARE DE INSTALACI N Usted puede no necesitar todas las piezas del conjunto Descarte las piezas que no utilice ART CULO pulgadas Cant Rejilla pl stica 2634 X 1612 1 Tira vertical de aislamiento 15 6 X 198 X 198 Tiras de aislamiento 6718 X 198 X 2 32 envolventes 5927 32 X 13 g X 198 Tira horizontal de aislamiento 237 32 X 198 X 13 16 Bloque de apoyo 13 4 X 198 x 45 16 Compuerta 14 x 412 x 18 Cu a 812X 1 Xx 34 Marco de ajuste Tornillos de arandela Tuercas Plastico Rejilla posterior INN IN C MO INSTALAR Identifique el soporte de pared
15. the desired temperature The thermostat can be set between 60 F 86 F 16 C 30 C 6 REMOTE CONTROL SENSOR 7 CLEAN FILTER Clean Filter LED will light up to notify you that your filter needs to be cleaned After cleaning the filter press Temp AV together to turn off Clean Filter light Filter reset must be done from unit control panel not remote control NOTICE This feature is reminder to clean the Air Filter See Maintenance for more efficient operation The LED light will illuminate after 250 hours of operation AUTO RESTART During operation in failure of electric power the unit runs as previous setting operation ENERGY SAVER The unit defaults to Energy Saver mode each time the unit is switched on except restoration after an electrical power outage and fan mode A CAUTION The remote controller will not function properly if strong light strikes the sensor of the air conditioner or if there are obstacles between the remote controller and the air conditioner 1 Push out the cover on the back of the remote control with your thumb 2 Pay attention to polarity and insert one new AAA 1 5V battery 3 Reattach the cover NOTICE Do not ure rechargeable battery Make sure that the battery is new Do not mix alkaline standard Carbon zinc or rechargeable Nickel cadmium battery In order to prevent discharge remove the batteries from the remote control if the air conditioner
16. the support blocks se 7 5 2 Wall Wall Sleeve Support Block Figure 13 Install the new unit into the wall sleeve a Assemble trim as described in Step 5 Procedure A Ah caution e Air conditioners covered in this manual pose an excessive weight hazard Two or more people are needed to move and install the unit To prevent injury or strain use proper lifting and carrying techniques when moving unit e When handling the air conditioner be careful to avoid cuts from sharp metal fins on front and rear coils e Make sure air conditioner does not fall during removal e If unit does not operate after installation check to be sure the circuit interrupter has not been tripped Refer to the Troubleshooting guide for reset procedure Installation Owner s Manual 15 m Z a H 77 ae Installation PROCEDURE C Redirect the louvers at the back of the wall sleeve to 60 angle as shown in Figure 14 The use of pliers is recommended 7 3132 60 A wean Rear Louvers Top View Figue 14 4 Remove the backing from the horizontal insulation strip 237 32 X 13 g x 1946 and attach that to the inside right of the sleeve as shown below Remove the backing from the around insulation strip 5927 32 x 137g x 137g and attach that to the inside front of the sleeve as shown below Indoor Outdoor 0 SS eS eS eS eeen A DR OR SS 8 8 E
17. 6 23 32 White Westinghouse Frigidaire Carrier B R Carrier Serie 52F 9 B General Electric g Hotpoint Len Whirlpool 17 1 8 23 Carrier Serie 51S 18 5 8 16 3 4 e Fedders Emerson 619 3 4 Emerson Fedders 15 Friedrich 16 3 4 6 Instale la nueva unidad en el soporte de pared A PRECAUCION Al finalizar la instalaci n la unidad de sustituci n DEBE tener una pendiente hacia atr s segun se ilustra Para lograr una pendiente de 1 4 retire el envoltorio de las cu as de 8 1 2 y ac plelas seg n se muestra a continuaci n en la Figure 3 Coloque el extremo m s alto de la cu a en la parte frontal de la base del soporte de pared zol 3 4 de alto Soporte UNIDAD de pared FRENTAL COLOCACI N DE LA CU A INSTALACI N DE LA UNIDAD Figure 3 34 Aire Acondicionador PROCEDIMIENTO A 11 Si est utilizando un nuevo soporte de pared incluido opcionalmente con su unidad salte al paso 3 Si no es as instale la rejilla pl stica Corte la rejilla pl stica a 25 1 2 de ancho y 15 1 4 de alto Coloque la rejilla pl stica en el interior del soporte de pared en la pesta a posterior Figure 4 2 Apriete los 4 tornillos de la arandela para asegurar la rejilla al soporte de pared Si necesita tuercas pl sticas para montar la rejilla pl stica en el interior del soporte de pared encontrar tuercas pl sticas en el equipo de
18. 671 g X 13 g X 25 32 and attach that to the inside front of the sleeve as shown below RRR RS DS RIE Rs EEE DS DS SES DS 17 a 91 6 44 CAUTION e Air conditioners covered in this manual pose an excessive weight hazard Two or more people are needed to move and install the unit To prevent injury or strain use proper lifting and carrying techniques when moving unit e When handling the air conditioner be careful to avoid cuts from sharp metal fins on front and rear coils Make sure air conditioner does not fall during removal e If unit does not operate after installation check to be sure the circuit interrupter has not been tripped Refer to the Troubleshooting guide for reset procedure Owners Manual 13 Installation PROCEDURE B Redirect the louvers at the back of the wall sleeve to 60 angle as shown in Figure 8 The use of pliers is recommended A NEN O Rear Louvers Top View Figure 8 If the wall sleeve already has a rear grille skip to step 4 If the wall sleeve does not have a rear grille or louvered panel install the plastic grille from the kit Cut the plastic grille to 25 1 2 wide and 15 1 4 high Place the plastic grille to the inside of the wall sleeve at the rear flange SES SOS 0 0 SS SS IS vesten SS RIS vaten RS os SS 5 5 es SS eS cece wees 5 SS sean 5 stoten PRS eee vens B
19. Aseg rese de que el aire acondicionado no se caiga al desmontarlo e Si la unidad no funciona tras la revisi n de instalaci n aseg rese que el interruptor del circuito no se ha disparado Consulte la gu a de soluci n de aver as para conocer el procedimiento de reinicio Manual del Propietario 35 Instalacion PROCEDIMIENTO B 1 Redireccione las rejillas de ventilaci n en la parte posterior del soporte de pared a un ngulo de 60 seg n muestra la FIG 8 Recomendamos el uso de alicates 7 3 30 Rejillas de ventilaci n posteriores wA Perspectiva superior Figure 8 2 Si el soporte de pared ya cuenta con una rejilla posterior salte al paso 4 Si el soporte de pared no tiene una rejilla posterior o un panel en rejilla instale la rejilla pl stica del conjunto Corte la rejilla pl stica a 25 1 2 de ancho y 15 1 4 de alto Coloque la rejilla pl stica en la parte interior del soporte de pared en la pesta a posterior w SS 55 SS SS ee See ses Ss SS SS sane iene RRS teen ee se ane SS Se eS SS SS aot SS SS 3 SS SS SS se A SS se ses S SS SS S Ss os SS SS SS ess ISS RS eee eee RRR Se secs SS S ess ee RS se seco sect gates gone x SS SS 3 e 3 es 5 si os ES ROSS e 3 SS 3 e e SS SS Coloque la rejilla pl stica Retire el envoltorio de la t
20. E AISLAMIENTO TIRA HORIZONTAL DE AISLAMIENTO BLOQUE DE APOYO COMPUERTA MARCO DE AJUSTE CUNA 2 AN D anamn a ay lt TUERCAS DE PL STICO Y TORNILLOS DE ARANDELA esosessSeso A PRECAUCION Para evitar riesgos de da os corporales materiales o da os al producto debidos al peso de este dispositivo y a los bordes afilados que pueden estar expuestos e Los aires acondicionados tratados en este manual representan un peligro por peso excesivo Son necesarias dos o m s personas para desplazar e instalar la unidad Para evitar lesiones o grandes esfuerzos utilice las t cnicas de elevaci n y desplazamiento para mover la unidad Examinar cuidadosamente la ubicaci n donde el aire acondicionado vaya a ser instalado Aseg rese de que aguantar el peso de la unidad a lo largo de un extenso per odo de tiempo Manipule con cuidado el aire acondicionado Utilice los guantes protectores siempre que levante o desplace la unidad EVITE las aristas afiladas de metal de las bobinas frontal y posterior Aseg rese de que el aire acondicionado no se caiga durante la instalaci n HERRAMIENTAS NECESARIAS e Guantes ce idos e Llave inglesa abierta o adecuados ajustable de 3 8 pulgadas e Destornillador est ndar Enchufe y carrete de tuerca Destornillador de estrella hexagonal de 1 4 pulgadas Alicates Cinta m trica e Cuchillo afilado Taladro el ctrico Boca de taladro de 1 4
21. EK oonoonoonoonoono R SS SS es este ste tete 222R SS SS SS SS SS SS SS es eee SS SS Seco sist eee SS SS eS see SS SS se SS siete eee westen SS ee sens es see III III EE RIRS SS Ss eS s Ss os ES ss aces RRR Z aes HOI es SS eS eS 12 If the wall sleeve already has a rear grille skip to step 4 If the wall sleeve does not have a rear grille or louvered panel install the plastic grille from the kit Cut the plastic grille to 26 1 2 wide and 15 1 2 high Place the plastic grille to the inside of the wall sleeve at the rear flange 817 Figure 17 S Sense 5 es se ee ves RS SS eee Seater Place the plastic grille If the depth of your existing sleeve is less than B or equal to 18 skip to step 7 Otherwise cut the baffles and the support blocks according to Length A in the table below Depth D of the existing Length A A wall sleeve inches inches D Support 18 lt D lt 18 5 3 4 Block 18 s lt D lt 19 4 1 3 4 T Baffle 19 3 4 lt D lt 22 4 A Figure 18 Figure 15 E Fasten the 4 washer screws to secure the grille to the wall sleeve If you need plastic nuts to mount plastic grille to the inside of the wall sleeve there are plastic nuts in the installation kit The nuts are installed from the inside of the sleeve and ar
22. ONSEJO Utilice el enchufe de la pared Consumo de Energia 15AMP o un Standard 250V enchufe de 3 Lineas de 15A 250V AC A ADVERTENCIA USO DE PROLONGADORES RIESGO DE INCENDIO Podr a ocasionar lesiones graves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos de tensi n ni adaptadores para m ltiples tomacorrientes con este Acondicionador de Aire de Ventana Utilice un fusible de Interruptor de 15AMP Seguraida Electrica El cable de alimentaci n puede incluir un dispositivo interruptor de corriente La carcasa del enchufe cuenta con un bot n de prueba y otro de reinicio El dispositivo debe comprobarse peri dicamente presionando primero el bot n TEST y despu s RESET Si el bot n TEST no se desconecta o si el bot n RESET no permanece activo suspenda el uso del aire acondicionado y p ngase en contacto con un t cnico de servicio cualificado A ADVERTENCIA No presione nunca el bot n de prueba durante el funcionamiento de lo contrario el enchufe podria resultar dafiado No desmonte modifique ni sumerja en agua este enchufe Si el dispositivo se activara deber corregir la causa antes de volver a utilizarlo A PRECAUCION Los hilos conductores dentro del cable est n rodeados por blindajes que supervisan la corriente de fuga Estos blindajes no est n puestos a tierra Examine peri dicamente el cable en busca de c
23. OTO D LIMPIEZA DEL FILTRO El LED Clean Filter Limpiar filtro se iluminar para avisarle que hay que limpiar el filtro Despu s de limpiar el filtro pulse simult neamente los botones Temp V para apagar la luz Clean Filter El reinicio del filtro debe hacerse desde el panel de control de la unidad no desde el mando a distancia CONSEJO Esta funcionalidad es un recordatorio para limpiar el Filtro de Aire Consulte Mantenimiento para un funcionamiento mas eficiente La luz LED se iluminara despu s de 250 horas de funcionamiento AUTO ARRANQUE En caso de fallo de la corriente el ctrica la unidad funcionar como antes cuando vuelve la corriente AHORRADOR DE ENEERGIA La unidad pasa de forma predeterminada al modo de Ahorro de Energia cada vez que la unidad se enciende excepto al restaurarse despu s de una falla de la energia el ctrica PRECAUTION El mando a distancia no funcionara correctamente si una luz fuerte hace contacto con el sensor del aire acondicionado o si hay obs culos entre el mando a distancia y el aire acondicionado 1 Empuje hacia afuera con su pulgar la cubierta en la parte posterior del control remoto 2 Preste atenci n a la polaridad e inserte dos nuevas bater a AAA 1 5V 3 Vuelva a colocar la cubierta CONSEJO No use bater a recargables Aseg rese que ambas baterias sean nuevas No mezcle las pilas alcalinas estandares Carbon zinc o recargables Niquel cadm
24. PLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE HOW TO OBTAIN WARRANTY SERVICE amp ADDITIONAL INFORMATION Call 1 800 243 0000 or visit our website at www lg com Mail to LG Customer Information Center ATTN CIC 201 James Record Road Huntsville AL 35824 Garantia GARANTIA LIMITADA DEL AIRE ACONDICIONADO LG EE UU COBERTURA DE LA GARANTIA LG Electronics Inc LG garantiza que reparar o sustituir gratuitamente su producto si resulta defectuoso en materiales o mano de obra bajo condiciones normales de uso durante el periodo de garant a mencionado m s abajo efectivo a partir de la fecha de compra del producto original por parte del consumidor Esta garant a limitada s lo es v lida para el comprador original del producto y no es asignable ni transferible a ning n otro comprador o usuario final subsecuentes y efectiva nicamente cuando el producto se compra a trav s de un distribuidor autorizado de LG y se utiliza en los Estados Unidos EE UU o en cualquiera de sus territorios Nota Los recambios y piezas de repuesto pueden ser nuevos o estar reconstruidos de f brica y est n garantizados durante el tiempo restante del periodo de garant a de la unidad original o noventa d as 90 el periodo de los dos que sea m s largo Por favor guarde el recibo de compra o la nota de entrega como prueba de la fecha de compra como comprobante de gar
25. S es te pS nee Se BS oes el 8 Si Place the plastic grille Figure 9 Fasten the 4 washer screws to secure the grille to the wall sleeve If you need plastic nuts to mount plastic grille to the inside of the wall sleeve there are plastic nuts in the installation kit The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges Fasten the screws Figure 10 14 Room Air Conditioner Remove the backing from the Vertical Insulation strip 15916 X 138 x 157g and attach that to the inside right of the sleeve as shown below Remove the backing from the Around Insulation strip 671 g X 138 X 25 32 and attach that to the inside front of the sleeve as shown below Indoor Outdoor DE SS SS DS SS RRR KK RR Seco Wy u 91 5 6 Figure 11 If the depth of your existing wall sleeve is less than or equal to 18 skip to step 6 Otherwise cut the baffles and the support blocks according to length A in the table below Depth D of the existing Length A A wall sleeve inches inches K Support 18 lt D lt 18 5 JA ral ROK 18 s lt D lt 19 4 1 3 4 ree Baffle 19 9 4 lt D lt 22 4 Al Figure 12 PROCEDURE B a Remove the backing from the support blocks and attach them to the inside of the wall sleeve as shown in Figure 13 Slide the baffle into slots of
26. Y consulte a un m dico No utilice el mande a distancia si las pilas han experimentado ugas e Los productos qu micos de las pilas podr an causar quemaduras u otros perjuicios a la salud 28 Aire Acondicionador Antes de poner el equipo en funcionamiento Fig Antes de poner el equipo en funcionamiento 1 P ngase en contacto con un especialista para realizar la instalaci n 2 Enchufe correctamente la toma de alimentaci n 3 Utilice un circuito dedicado 4 No utilice un cable alargador 5 No inicie cese el funcionamiento enchufando desenchufando el cable el ctrico 6 Si el cable enchufe est dafiado sustituyalo solo por una pieza autorizada Uso 1 Estando expuesto a la circulaci n directa de aire durante un extenso per odo de tiempo podr a resultar peligroso para su salud 2 Debido a la probabilidad de falta de ox geno ventile el cuarto cuando est utilizado el aparato junto con estufas u otros aparatos de calefacci n 3 No utilice este aire acondicionado con prop sitos especiales no especificados Ej conservaci n de dispositivos de precisi n comida animales dom sticos plantas y objetos de arte Tal uso podr a da ar los art culos CIF 1 No toque las piezas met licas de la unidad al retirar el filtro Manejar aristas afiladas de metal puede causar lesiones 2 No utilice el agua para limpiar el interior del aire acondicionado La exposici n al agua puede destruir el aislamiento co
27. a el interruptor de energi Falta de energ a 7 Cuando la energ a se reestablezca espere 3 minutos para encender de nuevo el aire acondicionado Con esto vitara que se produzca una sobrecarga en el compresor El dispositivo interruptor de corriente Presione el bot n RESET situado en el enchufe del cable est desconectado de alimentaci n Si el bot n RESET no p ermanece activo suspenda el uso del aure acondicionado y pongase en contacto con un t cnico de servicio cualificado El aire El flujo de aire esta restringido Aseg rese que no haya cortinas persianas o muebles acondiciona do no bloqueando el frente del aire acondicionado enfr a corno pa ee A ree debiera Coloque el control de TEMPERATURA Ajustar el control de temperatura a un n mero m s bajo en un numero mas alto El filtro de aire est sucio Limipe el filtro pro lo menos cada dos semanas Vea la secci n de instrucciones de operaci n El cuarto a n est caliente Cuando usted enciende el aire acondicionado debe esperar un momento para que la habitaci n se enftre El aire frio se est escapando Aseg rese que todas las salidas de aire est n cerradas para que el aire regrese El serpentin de refrigeraci n se ha Establezca una temperatura m s alta congelado El aire El hielo bloquea el flujo de aire y Elija el modo alto del ventilador High Fan o enfriado alto acondiciona do detiene el enfriamiento del cuarto High Cool enfria dernasiado Hay go
28. a suelta que est da ada toma a tierra e De lo contrario podr a provocar De lo contrario podr a provocar De lo contrario puede provocar un incendio o descarga un incendio o descarga una descarga el ctrica o el ctrica el ctrica incendio debido a la generaci n de calor No desmonte ni modifique Tenga cuidado al No use el cable de alimentaci n los productos desembalar e instalar el cerca gas inflamable o aparato materiales combustibles tales como la gasolina benceno disolvente etc e Puede ocasionar fallos y una e Los bordes afilados pueden e Podr a ocurrir una explosi n o descarga el ctrica provocar lesiones incendio Manual del Propietario 25 Precauciones de Seguridad B Operaci n No use el cable de alimentaci n No comparta el Saque el enchufe en caso de cerca gas inflamable o materiales tomacorriente con otros necesidad sosteniendo la combustibles tales como la electrodom sticos cabeza del enchufe y no lo gasolina benceno disolvente etc toque con las manos mojadas e Puede ocasionar una explosi n De lo contrario puede provocar una De lo contrario podr a provocar un o descarga el ctrica descarga el ctrica o incendio debido incendio o descarga el ctrica a la generaci n de calor No ponga el cable de No permita que entre agua Utilice un pa o suave para alimentaci n cerca de un en las piezas el ctricas limpiar No utilice cera calentador disolventes o detergente
29. ange of the front of the unit Deactivating Remote control signal Remove obstruction Prematurely obstructed Room too Set temperature too low Increase set temperature cold If you see CH in the display please call 1 800 243 0000 Owner s Manual 23 Precauciones de Seguridad 25 Antes de poner el equipo en funcionamiento 29 Introducci n a e 30 Seguraida Electrica 31 Instalacion A ae E 33 Instruccionnes de Funcionamiento 40 Cuidado y Mantenimiento 43 24 Aire Acondicionador _ PARA SUS ARCHIVOS Escriba aqu el modelo y n mero de serie Modelo n Serie n Puede encontrar estos datos en la etiqueta situada en el lateral de cada unidad Nombre del distribuidor Fecha de compra B Adjunte su recibo a esta p gina con la grapadora para el momento que lo necesite para probar la fecha de su adquisici n o para la validaci n de la garant a J LEA ESTE MANUAL En su interior encontrar muchos consejos tiles sobre la utilizaci n y mantenimiento de su acondicionador de aire Unos pocos cuidados por su parte le pueden ahorrar mucho tiempo y dinero durante la vida de su acondicionador de aire En la tabla de consejos para la soluci n r pida de problemas encontrara muchas respuestas a los problemas mas habituales Si revisa primero nuestra Tabla de Consejos para la soluci n
30. ant a se le puede pedir que presente una copia a LG o a su representante autorizado PERIODO DE GARANT A 1 a o desde la fecha de compra Cualquier repuesto interno funcional y mano de obra PROCESO DE SERVICIO Servicio a domicilio Los servicios a domicilio se prestar n durante el periodo de garant a sujeto a disponibilidad en los Estados Unidos El servicio a domicilio puede no estar disponible en todas las reas Para recibir asistencia t cnica a domicilio el producto debe estar en un entorno despejado y accesible al personal t cnico Si durante el servicio a domicilio la reparaci n no se puede llevar a cabo es posible que sea necesario desplazarlo a nuestras instalaciones repararlo y devolverlo a su hogar Si este fuera el caso LG puede optar a petici n nuestra a utilizar el transporte de nuestra elecci n para desplazar la unidad al y del centro de servicio autorizado de LG ESTA GARANT A LIMITADA NO SE APLICA A 1 Las visitas de Asistencia a domicilio para entregar recoger y o instalar el producto instruir o sustituir fusibles 2 Sustituci n de fusibles de la casa o reajuste de interruptores de circuito la correcci n del cableado de la casa o de la tuber a o la correcci n de la instalaci n del producto 3 Los da os o aver as causados por fugas roturas congelaci n de tuber as de agua l neas de drenaje restringido suministro insuficiente de agua o interrumpido o suministro insuficiente de aire 4
31. con una rejilla trasera para conectar el nuevo aire acondicionado de forma segura Figure 1 Con el soporte de pared LGE incluido opcionalmente con su unidad podr mantener el mejor rendimiento del nuevo aire acondicionado Figure 2 20 32 TS 511 mm 18 15 22 468 mm Aire acondicionado Figure 1 Rejilla de aluminio p 6 23 32 Soporte de pared 425 mm LGE Figure 2 SERVICIO EL CTRICO Compruebe su servicio el ctrico disponible La fuente de alimentaci n disponible debe ser igual que la que se muestra en la placa de identificaci n de la unidad encontrada en el lado izquierdo de la carcasa Todos los modelos est n equipados con un enchufe de tres dientes para proporcionar el servicio apropiado y poner a tierra el positivo de forma segura No cambie el enchufe de ninguna manera No utilice un enchufe adaptador Si su enchufe de pared actual no admite su enchufe llame a un electricista cualificado para realizar las correcciones necesarias GUARDE LA CAJA DE CART N para el almacenamiento y este MANUAL DEL PROPIETARIO para futuras referencias El cart n es la mejor manera de almacenar la unidad durante el invierno o cuando no est en uso Instalacion HARDWARE DE INSTALACI N SI SIL x RZ 7 7 E ted LLL Vid ZA Ao 2 opciones de tama o ART CULO NOMBRE DE LAS PIEZAS REJILLA DE PL STICO TIRA VERTICAL DE AISLAMIENTO TIRAS ENVOLVENTES D
32. d on you hot need to allow time for the room to cool down Cold air is escaping Check for open furnace floor registers and cold air returns Cooling coil have iced up See Air Conditioner Freezing Up below Air conditioner The cooling coils are iced Ice may block the air flow and obstruct the air freezing up over conditioner from properly cooling the room Set the mode control at High Fan or High Cool Water drips Hot humid weather This is normal outside Water drips The air conditioner is not For proper water disposal make sure the air indoors tilted to the outside ee slants slightly from the case front to the rear Water collects Moisture removed from air This is normal for a short period in areas with in base pan and drains into base pan little humidity normal for a longer period in very humid areas Air conditioner Dirty air filter air restricted Clean air filter turns on and Outside temperature SetFAN speed to a faster setting to bring air ff idi Outside temperature Set FAN speed to a faster setting to bring air ont rapidly extremely hot through cooling coils more frequently y Noise when Air movement sound _____ This is normal If too loud set to lower FAN setting unit is cooling Window vibration poor Refer to installation instructions or check with installation installer Remote Remote control not located Place remote control within 20 feet amp 120 radius Sensing within r
33. e la parte posterior de la unidad Ve gotear agua de la parte posterior de la unidad El agua puede ser recogida en la bandeja de base en condiciones de mucha humedad o d as de lluvia Esta agua desborda y gotea desde la parte posterior de la unidad Goteo o chapoteo Las gotas de agua que caen sobre el condensador durante la normal Traqueteo agudo Los compresores modernos de alto operaci n del producto pueden producir sonidos de goteo o chapoteo rendimiento pueden presentar un traqueteo agudo durante el ciclo de enfriado Sonido de r fagas de aire Delante de la unidad puede o r el sonido de r fagas de aire que son movidas por el ventilador Borboteo Siseo Un sonido parecido a un borboteo Vibraci n O siseo puede escucharse debido La unidad puede vibrar y hacer al refrigerante pasando a trav s ruido debido a una estructura d bil del evaporador durante una de la pared o la ventana o a una normal operaci n instalaci n incorrecta 44 Aire Acondicionador Mantenimiento y servici Resolucion de problemas l EI acondicionador de aire puede estar funcionando anormalmente cuando El aire El aire acondicionado est Asegurese q e ei aire acondicionado est conectado acondiciona do desconectado completamente a la fuente de energia no enciende El fusible esta quemado el interruptor Cheque los fusibles interruptor de la casa y reemplace de energ a se habloqueado los fuslbles o reestablezc
34. e pressed into the square holes of the rear flanges Fasten the screws Figure 16 16 Room Air Conditioner Remove the backing from the support blocks G and attach them to the inside of the wall sleeve as shown in Figure 19 Slide the baffle into slots of the support blocks Block Figure 19 Installation To achieve rearward slope for unit draining remove the backing from the 8 1 2 shim strips and attach them as shown below in Figure m 21 The higher portion of shim is to be placed Z in front of the rib on the base of wall sleeve a ui _ ac r high pe High Figure 20 Figure 21 a Install the new unit into the wall sleeve 9 Assemble trim as described in Step 6 Procedure A A CAUTION Air conditioners covered in this manual pose an excessive weight hazard Two or more people are needed to move and install the unit To prevent injury or strain use proper lifting and carrying techniques when moving unit When handling the air conditioner be careful to avoid cuts from sharp metal fins on front and rear coils Make sure air conditioner does not fall during removal e If unit does not operate after installation check to be sure the circuit interrupter has not been tripped Refer to the Troubleshooting guide for reset procedure Owner s Manual 17 Operating Instructions a Operating Instructions
35. iento A Instalacion A PRECAUCION e Los aires acondicionados tratados en este manual representan un peligro por peso excesivo Son necesarias dos o m s personas para desplazar e instalar la unidad Para evitar lesiones o esfuerzos excesivos utilice las t cnicas de levantamiento y desplazamiento apropiadas al mover la unidad e Manipule con cuidado el aire acondicionado tenga cuidado de evitar cortes de las aristas afiladas de metal de las bobinas frontal y posterior Aseg rese de que el aire acondicionado no se caiga al desmontarlo e Si la unidad no funciona tras la revisi n de instalaci n aseg rese que el interruptor del circuito no se ha disparado Consulte la gu a de soluci n de aver as para conocer el procedimiento de reinicio Manual del Propietario 39 Instruccionnes de Funcionamiento E Instruccionnes de Funcionamiento Funcionamiento d 7 D Cool F1 LOW F F2 MED Energy Clean ranan O Saver Filter Filter Reset Fan 2 TEMP Y Ae Dry Timer 4 FAN MODE TIMER SPEED POWER e e 1 POWER El funcionamiento se inicia cuando se pulsa esta tecla y se detiene cuando se la presiona nuevamente 2 SELECTOR DE VELOCIDAD DEL VENTILADOP Usado para ajustar la velocidad del ventilador a Low F1 MED F2 High F3 3 CRONOMETRO ON OFF Encendido Cuando el acondicionador de aire esta apagado puede ajustarse para que se encienda automaticamente dentro de 1 a 24 hora
36. ira vertical de aislamiento 15 9 16 x 1 3 8 x 1 3 8 y nala a la parte interior derecha del soporte de pared seg n se muestra a continuaci n Retire el envoltorio de la tira de aislamiento envolvente de 67 1 8 x 1 3 8 x 25 32 y nala a la parte frontal interior del soporte de pared seg n se muestra a continuaci n Interior Exterior SIRI iento vertical Zg DS DRESS IIIe in 91 6 Figure 11 Si la profundidad de su soporte de pared es menor o igual a 18 salte al paso 6 Si no corte las compuertas y los bloques de soporte seg n la longitud A en la tabla a continuaci n Profundidad D del soporte _ Longitud A A de pared existente pulgadas pulgadas K Bila 18 lt D lt 18 s 3 4 a de apoyo 18 5 s lt D lt 19 3 4 1 3 4 an Compuerta ps a A Figure 12 Figure 9 E Apriete los 4 tornillos de la arandela para asegurar la rejilla al soporte de pared Si necesita tuercas pl sticas para montar la rejilla pl stica en el interior del soporte de pared encontrar tuercas pl sticas en el equipo de instalaci n Las tuercas est n instaladas en el interior del soporte de pared y est n presionando las perforaciones cuadradas de las pesta as posteriores Apriete los tornillos Figure 10 36 Aire Acondicionador PROCEDIMIENTO B a Retire el envoltorio de los bloques de apoyo y ac plelos al interior del s
37. is not going to be used for an extended period of time Keep the remote control away from extremely hot or humid places To maintain optimal operation of the remote control the remote sensor should not be exposed to direct sunlight Owner s Manual 19 Operating Instructions Ventilation The ventilation lever is located in the right of the air discharge The ventilation lever must be in the CLOSE posotion in order to maintain the best cooling conditions When fresh air is necessary in the room set the ventilation lever to the OPEN position The damper is opened and room air is exhausted outside a CLOSE zin VENT alla OPEN Air Direction i The direction of air can be controlled wherever you want by adjusting the horizontal louver and the vertical louver HORIZONTAL AIR DIRECTION CONTROL VERTICAL AIR DIRECTION CONTROL The horizontal air direction is adjusted by moving The vertical air direction is adjusted by moving vertical louver the horizontal louver The lever of vertical louver is located in the right and left side of the air discharge 20 Room Air Conditioner Maintenance and Service E Maintenance and Service TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET The air filter should be checked at least twice a month to see if cleaning is necessary Trapped particles in the filter will build up and block the airflow This reduces the cooling capacity and also causes an accumulation of frost
38. ium e Para evitar que se descarguen quite las bater as del control remoto si el acondicionador de aire no va a ser usado por un per odo largo de tiempo Mantenga el control remoto lejos de los lugares h medos o extremadamente calientes Para mantener el funcionamiento ptimo del control remoto el sensor remoto no debe exponerse a la luz solar directa Manual del Propietario 41 Instruccionnes de Funcionamiento Control de ventilacion Empuje la palanca hacia la posici n CLOSE cerrado para que el aire de la habitaci n se caliente se enfr e o simplemente recircule Empuje la palanca hacia la posici n OPEN abierto para expulsar el humo o el aire estancado de la habitaci n Obtendr el m ximo rendimiento de esta funci n si se utiliza junto con la posici n FAN ONLY s lo ventilador a CLOSE zin VENT sl OPEN Direcci n del aire i Se puede controlar la direcci n del aire ajustando las persianas horizontales y verticales e AJUSTE DE LA DIRECCI N e AJUSTE DE LA DIRECCI N HORIZONTAL DEL AIRE VERTICAL DEL AIRE La direcci n horizontal del aire se ajusta La direcci n vertical del aire se ajusta moviendo la persiana vertical La palanca de moviendo las persianas horizontales la persiana vertical se ubica a la derecha y a la izquierda de la descarga de aire 42 Aire Acondicionador Cuidado y Mantenimiento A Cuidado y Mantenimiento APAGUE EL ACONDICIONADOR DE AIRE Y DESENCH FELO DE LA FUENTE
39. l and 5 Damage or failure resulting from misuse abuse improper usual household use e g rental commercial use installation repair or maintenance Improper repair offices or recreational facilities or contrary to the includes use of parts not approved or specified by LG instructions outlined in the owner s manual 6 Damage or failure caused by unauthorized modification or 12 The removal and reinstallation of the Product if it is alteration to the product installed in an inaccessible location 7 Damage or failure caused by incorrect electrical current voltage or plumbing codes THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESS OR IMPLIED INCLUDING AND WITHOUT LIMITATION TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT ANY IMPLIED WARRANTY IS REQUIRED BY LAW THIS WARRANTY IS LIMITED IN DURATION TO THE TERM PERIOD EXPRESSED ABOVE REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY FOR THE CUSTOMER NEITHER THE MANUFACTURER NOR ITS U S DISTRIBUTOR SHALL BE LIABLE FOR ANY INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY NATURE INCLUDING AND WITHOUT LIMITATION TO LOST REVENUES OR PROFITS OR ANY OTHER DAMAGE WHETHER BASED IN CONTRACT TORT OR OTHERWISE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE EXCLUSION OR LIMITATION MAY NOT AP
40. l power outlet to minimize the hazard of electric shock The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded 10 Room Air Conditioner DO NOT CUT OR REMOVE THE THIRD GROUND PRONG FROM THE POWER PLUG A SITUATIONS WHEN THE APPLIANCE WILL BE DISCONNECTED OCCASIONALLY Because of potential safety hazards we strongly discourage the use of an adapter plug However if you wish to use an adapter a TEMPORARY CONNECTION may be made Use UL listed adapter available from most local hardware stores The large slot in the adapter must be aligned with the large slot in the receptacle to assure a proper polarity connection A CAUTION Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated and the wall receptacle is grounded through the house wiring The customer should have the circuit checked by a qualified electrician to make sure the receptacle is properly grounded Disconnect the power cord from the adapter using one hand on each Otherwise the adapter ground terminal might break DO NOT USE the appliance with a broken adapter plug B SITUATIONS WHEN THE APPLIANCE WILL BE DISCONNECTED OFTEN Do not use an adapter plug in these situations Unplugging the power cord frequently can lead to an eventual breakage of the ground terminal The wall p
41. lability within the United States In home service may not be available in all areas To receive in home service the product must be unobstructed and accessible to service personnel If during in home service repair cannot be completed it may be necessary to remove repair and return the product If in home service is unavailable LG may elect at our option to provide for transportation of our choice to and from a LG authorized service center THIS LIMITED WARRANTY DOES NOT COVER 1 Service trips to deliver pick up or install the product or 8 Cosmetic damage including scratches dents chips or for instruction on product use other damage to the finish of the product unless such 2 Replacing house fuses or resetting of circuit breakers damage results from defects in materials or correction of house wiring or plumbing or correction of workmanship and is reported to LG within seven 7 product installation calendar days from the date of delivery 3 Damage or failure caused by leaky broken frozen water 9 Damage or missing items to any display open box pipes restricted drain lines inadequate or interrupted discounted or refurbished product water supply or inadequate supply of air 10 Product where the original factory serial numbers have 4 Damage or failure caused by accidents pests and vermin been removed defaced or changed in any way lightning wind fire floods or acts of God 11 Repairs when product is used in other than norma
42. lems and Solutions Before Calling for Service If you have problems with your air conditioner read the following information and try to solve the problem If you cannot find a solution turn off the air conditioner and call 1 800 243 0000 Air conditioner does not operate 1 Ensure that the air conditioner is plugged into an outlet of the proper voltage and amperage 2 Check the fuse or circuit breaker 3 Check whether the voltage is unusually high or low Air does not feel cold enough on the cooling setting 1 Ensure that the temperature settings are correct 2 Check to see if the air filter is clogged with dust If so clean the filter 3 Ensure that the air flow from the outside is not obstructed and that there is a clearance of over 20 between the back of the air conditioner and the wall or fence behind it 4 Close all doors and windows and check for any source of heat in the room Water drip from the rear of the unit You see water dripping from the rear of the unit Water may be collected in the base pan in highly humid conditions or on rainy days This water overflows and drips from the rear of the unit Normal S Pinging or Swishing High pitched Chatter Droplets of water hitting condenser during normal operation may cause pinging or swishing sounds Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the fro
43. mbiente humedo e De lo contrario puede provocar Provocar descargas el ctricas Provocar descargas una descarga el ctrica o o incendios el ctricas incendio debido a la eneraci n de calor la f in ua Qs aN pe le Kx pie CIR Sostenga el enchufe porsu Cuando haya un escape de No toque las partes cabeza al sacarlo gas abra la ventana para met licas del aparato al ventilar antes de poner en sacar el filtro del aire marcha la unidad e Podr a ocasionar una descarga De lo contrario podr a ocurrir Son puntiagudas y pueden el ctrica y da os una explosi n o incendio provocar lesiones 5 Ca Para una limpieza interior p ngase en contacto con un Centro de Servicios Autorizado o un revendedor No utilice detergentes abrasivos que causan corrosi n o da an la unidad Los detergentes abrasivos pueden igualmente provocar un fallo del producto un incendio o una descarga electr nica ADVERTENCIA E Instalaci n Instale el producto de modo que el ruido o Mantenga nivelado el producto al instalarlo el aire caliente producido por la unidad externa no moleste a los vecinos e De lo contrario puede dar lugar a disputas e De lo contrario se podr a causar vibraciones o vecinales escapes de agua Manual del Propietario 27 Precauciones de Seguridad E Operaci n No ponga plantas ni animales en la trayectoria que recorrer el aire caliente e Podr a ocasionar lesiones
44. nduciendo a posibles descargas el ctricas 3 Al limpiar la unidad aseg rese antes de que la electricidad y el interruptor est n apagados El ventilador rota a muy alta velocidad durante el funcionamiento del equipo Existe la posibilidad de lesiones si acciona accidentalmente la electricidad de la unidad mientras limpia el interior de la unidad Servicio Para cuestiones de reparaci n y mantenimiento p ngase en contacto con su distribuidor de servicio autorizado Manual del Propietario 29 Introducci n E Introducci n Este s mbolo lo advierte de un peligro de accidente por corriente el ctrica Este simbolo lo adiverte de un peligro que pueda causar un dano del ventliador 0 EJ A 0 Este s mbolo significa condicciones especiales Caracter sti A ADVERTENCIA Este aparato deber a instalarse de acuerdo con las normas del C digo El ctrico Nacional EL SOPORTE DE PARED Y LA REJILLA POSTERIOR incluido opcionalmente con su unidad MONTAJE DEL SOPORTE DE PARED Incluyendo rejilla posterior de aluminio REJILLA POSTERIOR Rejilla posterior de aluminio DEFLECTOR VERTICAL DE AIRE Rejilla de ventilaci n horizontal DESCARGA DE AIRE FILTRO DE AIRE ARMARIO REJILLA DE ENTRADA Toma de aire REJILLA FRONTAL DEFLECTOR HORIZONTAL DE AIRE Rejilla de ventilaci n vertical CONTROL DEL ORIFICIO DE VENTILACI N 30 Aire Acondicionador E Seguraida Electrica C
45. not aimed directly at the neighbors e Be considerate e Otherwise it may cause vibration or water leakage Owner s Manual 5 Safety Precautions E Operation Do not use this appliance for special purposes such as cooling pets foods precision machinery or objects of art e It is an air conditioner not a Do not step on the indoor outdoor unit and do not put anything on it e It may cause an injury through dropping of the unit or falling down precision refrigeration system Do not block the inlet or outlet of air flow e It may cause product failure Always insert the filter securely Clean it every two weeks e Operation without filters will cause failure Use a soft cloth to clean Do not use wax thinner or a strong detergent e The appearance of the air conditioner may deteriorate change color or develop surface flaws Do not drink water drained from air conditioner e lt contains containments and will make you sick Be cautious not to touch the Instead of running air conditioning Do not insert the hands or sharp edges when installing e It may cause injury constantly open a window for fresh air occasionally e You will feel better bars through the air inlet or outlet during operation e Otherwise it may cause personal injury If the liquid from the battery gets onto your skin or clothers wash it well with clean water Do not use the remote if
46. nt of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Vibration Gurgling or hissing noise may be n E heard due to refrigerant passing mie ay vibrate ard of poor through evaporator during normal wall or window construction operation or incorrect installation 22 Room Air Conditioner Maintenance and Service The air conditioner may be operating abnormally when Air The air conditioner is Make sure the air conditioner plug is pushed conditioner unplugged completely into the outlet coes not The fuse is blown circuit Check the house fuse circuit breaker box and Sia breaker is tripped replace the fuse or reset the breaker Power failure If power failure occurs turn the mode control to Off When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload The current interrupter Press the RESET button located on the power device is tripped cord plug If the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Air conditioner Airflow is restricted Make sure there are no curtains blinds or does not cool furniture blocking the front of the air conditioner as it should Emone Aar nn pei eey LL TT The air filter is dirty Clean the filter at least every 2 weeks See the care and Maintenance section The room may have been When the air conditioner is first turne
47. on the cooling coils If the filter becomes turn or damaged you should replace immediately Replacement filters are available from your salesperson dealer and the authorized customer service centers 1 Open the inlet grille downward by pulling out the top of the inlet grille 2 Remove the air filter from the front grille assembly by pulling the air filter up slightly 3 Wash the filter using lukewarm water below 40 C 104 F 4 Gently shake the excess water from the filter completely Replace the filter How To Attach Front The front grille can be removed for cleaning or to check the model and serial numbers For your safety you should attach the front grille as the following procedures 1 Pull down front grille from the cabinet top 3 Open the inlet grille 2 Push front grille s tips toward the cabinet in 4 Tighten the screw through the front grille into order to insert front grille s tabs into the the plate of control box cabinet 5 Close inlet grille Guide the lever carefully through the grille as you push it in Owner s Manual 21 Maintenance and Service Common Prob
48. on una rejilla posterior salte al paso 4 Si el soporte de pared no tiene una rejilla posterior o un panel en rejilla instale la rejilla pl stica del conjunto Corte la rejilla pl stica a 26 1 2 de ancho y 15 1 2 de alto Coloque la rejilla pl stica en la parte interior del soporte de pared en la pesta a posterior R g es so se rests aes PRRP ns SS 8 eee IS A Se ae 3 es aten be o ate ten SS os 239S Bs ee Siete o e 8 lt n ete 2 Coloque la rejilla pl stica Figure 15 E Apriete los 4 tornillos de la arandela para asegurar la rejilla al soporte de pared Si necesita tuercas pl sticas para montar la rejilla pl stica en el interior del soporte de pared encontrar tuercas pl sticas en el equipo de instalaci n Las tuercas est n instaladas en el interior del soporte de pared y est n presionando las perforaciones cuadradas de las pesta as posteriores Figure 16 Apriete los tornillos 38 Aire Acondicionador Retire el envoltorio de la tira horizontal de aislamiento de 23 7 32 x 1 3 8 x 1 3 16 y Unala a la parte interior derecha del soporte de pared seg n se muestra a continuaci n Retire el envoltorio de la tira de aislamiento envolvente de 59 27 32 x 1 3 8 x 1 3 8 y nala a la parte frontal interior del soporte de pared seg n se muestra a continuaci n Interi
49. oporte de pared como muestra la Figure 13 Deslice la compuerta en las ranuras de los bloques de apoyo 7 320 Pared gt BE Pee Compuerta O Bloque de apoyo J Figure 13 Instale la nueva unidad en el soporte de pared a Ajuste la posici n seg n describe el paso 5 procedimiento A A PRECAUCION e Los aires acondicionados tratados en este manual representan un peligro por peso excesivo Son necesarias dos o m s personas para desplazar e instalar la unidad Para evitar lesiones o esfuerzos excesivos utilice las t cnicas de levantamiento y desplazamiento apropiadas al mover la unidad e Manipule con cuidado el aire acondicionado tenga cuidado de evitar cortes de las aristas afiladas de metal de las bobinas frontal y posterior e Aseg rese de que el aire acondicionado no se caiga al desmontarlo e Si la unidad no funciona tras la revisi n de instalaci n aseg rese que el interruptor del circuito no se ha disparado Consulte la gu a de soluci n de aver as para conocer el procedimiento de reinicio Instalacion Manual del Propietario 37 Instalacion PROCEDIMIENTO C 1 Redireccione las rejillas de ventilaci n en la parte posterior del soporte de pared a un ngulo de 60 seg n muestra la Figure 14 Recomendamos el uso de alicates 60 A 7 3 30 Rejillas de ventilaci n posteriores Perspectiva superior Figure 14 2 Si el soporte de pared ya cuenta c
50. or Exterior i KRI ki en SS EE RR SS SRR 17 8 1 3 Figure 17 B Si la profundidad de su soporte de pared es menor o igual a 18 salte al paso 7 Si no corte las compuertas y los bloques de apoyo seg n la longitud A en la tabla a continuaci n Profundidad D del soporte Longitud A A de pared existente pulgadas pulgadas K Bloque 18 lt D lt 18 5 s 3 4 de apoyo 18 e lt D lt 19 4 1 3 4 Compuerta 19 2 4 lt D lt 22 4 peice B Retire el envoltorio de los bloques de apoyo y nalos al interior del soporte de pared como muestra la FIG 19 Deslice la compuerta dentro de las ranuras en los bloques de apoyo Pared Soporte de pared Compuerta 1 i 1 1 1 i i 1 Frontal Bloque de poyo Figure 19 PROCEDIMIENTO C Para lograr una pendiente de posterior para el drenaje de la unidad retire el envoltorio de las cufias de 8 1 2 y ac plelas seg n se muestra a continuaci n en la FIG 21 Coloque el extremo m s alto de la cu a en la parte frontal de la base del soporte de pared 1 de ji 3 alto de alto Figure 20 SS SE es SEER ES SKK KK ss 35 29 50 X SS Se veter Figure 21 a Instale la nueva unidad en el soporte de pared O Monte el ajuste seg n lo descrito en el paso 6 procedim
51. or use by young children or invalids without supervision e Young children should be supervised to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts e Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only Safety Precautions E Safety Precautions To prevent injury to the user or other people and property damage the following instructions must be followed E Incorrect operation due to ignoring instruction will cause harm or damage The seriousness is classified by the following indications WARNING This symbol indicates the possibility of death or serious injury ACAUTION This symbol indicates the possibility of injury or damage to properties only Meanings of symbols used in this manual are as shown below he 0 Be sure not to do Q Be sure to follow the instruction AWARNING E Installation Don t use a power cord a Always plug into a grounded Do not modify or extend the plug or a loose socket outlet power cord length which is damaged e Otherwise it may cause a fire Otherwise it may cause a fire e It will cause electric shock or fire or electrical shock or electrical shock due to heat generation Do not disassemble or Be caution when unpacking Do not sto
52. ower outlet should be replaced by a three slot grounding outlet instead Ai Installation Remove packing materials from the wall sleeve and tape from the air conditioner INSTALLATION REQUIREMENTS If you use an existing wall sleeve you should measure its dimensions Install the new air conditioner according to these installation instructions to achieve the best performance All wall sleeves used to mount the new air conditioner must be in good structural condition and have a rear grille to securely attach the new air conditioner Figure 1 With the LGE sleeve optionally supplied with your unit you can maintain the best performance of the new air conditioner Figure 2 Air Conditioner Figure 1 Aluminum metal grille 16 23 32 _ 425 mm LGE Wall Sleeve Figure 2 ELECTRICAL SERVICE Check your available electrical service The power supply available must be the same as that shown on the unit nameplate found on left side of cabinet All models are equipped with a 3 prong service plug to provide proper service and safe positive grounding Do not change plug in any way Do not use an adapter plug If your present wall outlet does not match your plug call a qualified electrician to make the necessary corrections SAVE CARTON for storage and this OWNER S MANUAL for future reference The carton is the best way to store unit during winter or when not in use Installation INSTALLATION HARDWARE
53. r pida de problemas tal vez no necesite llamar nunca al servicio t cnico PRECAUCION e P ngase en contacto con un t cnico del servicio autorizado para realizar la reparaci n y mantenimiento de esta unidad e P ngase en contacto con un instalador para realizar la instalaci n de esta unidad e Cuando se va a cambiar el cable el ctrico el trabajo de reemplazamiento debe ser realizado nicamente por personal autorizado utilizando las piezas de cambio genuinas nicamente El trabajo de reemplazamiento debe ser realizado de acuerdo con el C digo El ctrico Nacional nicamente por personal autorizado Precauciones de Seguridad ai Precauciones de Seguridad Para evitar lesiones al usuario o a otras personas y da os a la propiedad estas instrucciones est n seguirse E Una operaci n incorrecta por ignorar las instrucciones provocar lesiones o da os La seriedad se clasifica por las siguientes indicaciones 7 A ADVERTENCIA Este s mbolo indica la posibilidad de muerte o de seria lesi n A PRECAUCION Este s mbolo indica s lo la posibilidad de lesiones o da os a la propiedad GC aif E Significados de los s mbolos utilizados en este manual a a Q No hacer 19 Siga estas instrucciones NZ a ADVERTENCIA E Instalaci n No utilice un cable de Enchufe siempre a un No modifique ni alargue el alimentaci n enchufe o una tomacorriente que tenga cable de alimentaci n tom
54. r 23 16 3 4 Fedd E 27 16 3 4 edders Emerson 6 3 or 19 3 4 LGE 25 7 8 15 17 32 16 23 32 Emerson Fedders 26 3 4 15 3 4 15 Carrier 51S Series 25 3 4 16 7 8 18 5 8 Friedrich 27 16 3 4 16 3 4 12 Room Air Conditioner NOTICE All wall sleeves used to mount the new air conditioner must be in sound structural condition and have a rear grille that securely attaches to sleeve or rear flange that serves as a stop for the air conditioner Remove the old airconditioner from existing wall sleeve E Clean the interior of the existing sleeve Do not disturb seals 4 Wall sleeve must be securely fastened in wall before installing the air conditioner Use the nails or screws through sleeve into wall if needed Repaint sleeve if needed Prepare the wall sleeve for installation of the unit If you plan to use your existing wall sleeve and it is not LGE use procedure B or C below Procedure Brand Depth inches A LGE 16 23 32 White Westinghouse Frigidaire Carrier 16 Tug 52F series or B General Electric 5 Hotpoint 1657 8 Whirlpool 17 1 8 or 23 Carrier 51S series 18 5 8 16 3 4 A Fedders Emerson or 19 3 4 Emerson Fedders 15 Friedrich 16 3 4 a Install new unit into wall sleeve 44 CAUTION When installation is completed the replacement unit MUST have a rearward slope as shown To achieve 1 4 slope remove the backing from the 8 1 2 shim strips and at
55. rada MAZ Guie la palanca cuidadosamente a trav s de la parrilla mientras la empuja Manual del Propietario 43 Mantenimiento y servicio Problemas y Soluciones habitu Antes de Llamar el Servicio de Asistencia T cnica Si tiene problemas con su ventilador lea las informaciones siguientes y trate de resolver el problema Si no puede encontrar la soluci n desconecte el ventilador y dirijase a 1 800 243 000 El ventilador no funciona 1 Compruebe que el ventilador est conectado en un enchufe correcto 2 Revise el fusible 3 Compruebe que la tensi n no sea demasiado alta o baja Al ajustarse el enfriamiento el aire no parece fr o lo suficiente 1 Revise si los ajustes de la temperatura son correctos 2 Revise si el filtro de aire no est atascado de polvo En el caso de que s cambie el filtro 3 Compruebe que afuera no haya un obst culo del flujo de aire y si entre la parte trasera del ventilador y la pared o la barrera haya espacio libre de por lo menos 1 metro 20 4 Cierre todas las puertas y ventanas y compruebe que no haya una fuente de calor en la habitaci n Ve gotear agua d
56. re flammables like modify products and installing gasoline benzene thinner etc near the air conditioner e It may cause failure and e Sharp edges may cause e It may cause explosion or fire electric shock Owner s Manual 3 Safety Precautions B Operation Do not place heavy object Do not share the outlet with Take the power plug out if on the power cord and take other appliances necessary holding the head care so that the cord should of the plug and do not touch not be pressed it with wet hands e There is danger of fire or electric It will cause electric shock or fire Otherwise it may cause a fire or electrical shock shock due to heat generation A y Co q fa E Y S N VA IN IN IPod Do not place the power cord Do not allow water to run Use a soft cloth to clean Do near a heater into electric parts not use wax thinner or a strong detergent It may cause fire and electric e It will cause failure of machine or The appearance of the air electric shock conditioner may deteriorate change color or develop surface flaws AS AS Ly Thing AI Unplug the unit if strange Do not open the suction If water enters the product turn sounds odors or smoke inlet grill of the product off the the power switch of the come from it during operation main body of appliance Contact service center after taking the power plug out from the socket e Otherwise it may cause fire and
57. s fuertes e Puede ocasionar un incendio y Puede provocar fallos en el e La apariencia del aparato de aire una descarga el ctrica producto o descargas acondicionado puede deteriorar el ctricas cambiar el color o desarrollar flujos en las superficies gi enn qe 00 Desenchufe la unidad si oye No abra la parrilla de Si entra agua en el producto un sonido extra o olores o entrada al aparato mientras apague el interruptor de la si observa salir humo est en funcionamiento carcasa principal del aparato P ngase en contacto con el centro de servicio despu s de haber sacado el enchufe del tomacorriente e De lo contrario puede ocurrir e De lo contrario pueden ocurrir un incendio y un accidente por descargas el ctricas y fallos descarga el ctrica Ventile bien la sala al usar Apague el aparato y el Apague el interruptor de este aparato con una estufa interruptor diferencial alimentaci n principal cuando etc primero antes de limpiar la no vaya a utilizar el aparato unidad durante mucho tiempo e Puede ocurrir un falta de e Debido a que el ventilador gira a e Evitar el arranque accidental y ox geno alta velocidad durante el la posibilidad de lesiones funcionamiento podr a ocasionar 26 Aire Acondicionador Precauciones de Seguridad No opere ni detenga la No dane ni use un enchufe No toque el producto con unidad insertando o de alimentacion no las manos mojadas o en un estirando de enchufe especificado a
58. s en el nivel previo Apagado Cuando el acondicionador de aire esta apagado puede ajustarse para que se apague automaticamente dentro de 1 a 24 horas 4 FUNCIONAMIENTO DEL MODO SELECTOR Pulse el bot n MODE Modo para desplazarse entre Ahorro de Energia Frio Ventilador Secar Energy Saver Ahorro de Energ a El ventilador se detiene cuando el compressor no sigue enfriando Aporximadamente cada 3minutos el ventilador se encender y necesitara verificar la temperatura del cuarto para saber si es necesario mas enfriamiento Cool frio El compresor funciona y enfria la habitaci n Use los botones TEMP TIMER A V y FAN ventilador para configurar la temperatura deseada y la velocidad de circulaci n del ventilador FAN ventilador El ventilador hace circular el aire pero el compresor no funciona no funciona Utilice el bot n FAN ventilador para configurar la velocidad deseada del ventilador DRY El modo de secado se utiliza para eliminar la humedad de la sala sin a adir refrigeraci n adicional Una vez se alcanza la temperatura el compresor y el ventilador de circulaci n se apagan La velocidad del ventilador est predefinida y no puede ajustarse 40 Aire Acondicionador Instruccionnes de Funcionamiento 5 CONTROL DE TEMPERATURA El termostato monitorea la temperature de la habitaci n para mantener la temperatura deseada El termostato puede ser colocado entre 60 F 86 F 16 C 30 C 6 SENSOR DEL CONTROL REM
59. tach them as shown below in Fig 3 Place the higher portion of the shim to the front of the rib on the base of the wall sleeve 1 highf 3 4 High UNIT Wall Sleeve FRONT Le SHIM PLACEMENT UNIT INSTALLATION Figure 3 PROCEDURE A If you are using the new sleeve optionally supplied with your unit skip to step 3 Otherwise install the plastic grille from the kit Cut the plastic grille to 25 1 2 wide and 15 1 4 high Place the plastic grille to the inside of the wall sleeve at the rear flange Installation 4 Install the new unit into the wall sleeve B To assemble trim snap the tab of each piece into the slot of the other piece as shown below Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below Figure 4 Fasten the 4 washer screws to secure the grille to the wall sleeve If you need plastic nuts to mount plastic grille to the inside of the wall sleeve there are plastic nuts in the installation kit The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges y A Trim 2 ea y Figure 7 Figure 5 Remove the backing from the vertical insulation strip 15916 x 198 x 157g and attach that to the inside right of the sleeve as shown below Remove the backing from the around insulation strip
60. tates at a very high speed during operation There is a possibility of injury if the unit s power is accidentally triggered on while cleaning inner parts of the unit Service For repair and maintenance contact an Authorized Service Center See the warranty page for details or call 800 243 0000 Have your model number and serial number available They should be written on page 2 of this manual Owner s Manual 7 Introduction E Introduction A This symbol alerts you to the risk of electric shock This symbol alerts you to hazards that could cause harm to A the air conditioner Nojy 01 4 This symbol indicates special notes Features 44 WARNING This appliance should be installed in accordance with the National Electric Code THE SLEEVE AND THE REAR GRILLE optionally supplied with your unit SLEEVE ASSEMBLY Including Aluminum Rear grille REAR GRILLE Aluminum Rear grille VERTICAL AIR DEFLECTOR Horizontal Louver AIR DISCHARGE AIR FILTER i CABINET INLET GRILLE Air Intake FRONT GRILLE HORIZONTAL AIR DEFLECTOR Vertical Louver VENT CONTROL 8 Room Air Conditioner Electrical Safety E Electrical Safety Power cord may include a current interrupter device A test and reset button is provided on the plug case The device should be tested on a periodic basis by first pressing the TEST button and then the m Z a un I RESET button If the TEST button does
61. teo de agua Clima caliente y himedo Esto es normal en la parte externa Hay goteo de El acondicionador de aire no esta Para una salida correcta del agua asegurese de que el aguaen la parte inclinado hacia el exterior acondicionador de aire se incline levemente desde la interna parte frontal hasta la parte trasera de la caja Se acumula agua Se elimino la humedad del aire y se Esto es normal durante un peri do corto en afeas con en la bandeja drena en la bandeja poca humedad es normal durante un per odo m s largo en areas muy humedas El aparato de aire Filtro de aire sucio flujo de aire Limpie el filtro acondicionado se _ restringido eee enciende y apaga La temperatura exterior es Establezca el ventilador en una velocidad m s alta para r pidamente extremadamente c lida conseguir que el aire circule m s r pidamente por el circuito refrigerador Se escuchan Suena el movimiento del aire Esto es normal Si est muy fuerte ajuste el FAN ruidos cuando el A _ ventilador a una velocidad m s baja ______________ equipo est Vibraci n de la ventana instalaci n Consulte las instrucciones de montaje o al instalador operando defectuosa El sensor remoto El control remoto no est en el rango Ubique el control remoto dentro de un rango de 20 pies y se desactiva de de alcance en un ngulo de 120 desde el frontal de la unidad manera prematura La se al del control remoto est Remueva la obstrucci n obstruida
62. the battery has leaked The chemicals in battery could cause burns or other health hazards 6 Room Air Conditioner If you eat the liquid from the battery brush your teeth and see doctor Do not use the remote if the battery have leaked e The chemicals in battery could cause burns or other health hazards A T Y gt Before Operation m a a Un I Preparing for Operation Contact an installation specialist for installation Plug in the power plug properly Use a dedicated circuit Do not use an extension cord Do not start stop operation by plugging unplugging the power cord If the cord plug is damaged replace it with only an authorized replacement part RON Usage 1 Being exposed to direct airflow for an extended period of time could be hazardous to your health 2 No correlation between fan usage and oxygen depletion 3 Do not use this air conditioner for non specified special purposes e g preserving precision devices food pets plants and art objects Such usage could damage the items Cleaning and Maintenance 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure that the power and breaker are turned off The fan ro
63. ualquier da o No utilice este producto si los blindajes resultaran expuestos Evite el riesgo de descargas el ctricas esta unidad no puede ser reparada por el usuario por ser resistente y a prueba de alteraciones Manipular la porci n sellada de la unidad anular todas las garantias y quejas de rendimiento Esta unidad no esta disefiada para su USO como un interruptor de encendido apagado Aire Acondicionador 31 Seguraida Electrica IMPORTANTE FAVORLEA CON ATENCION POR LA SEGURIDAD PERSONAL DEL USUARIO ESTE APARATO DEBE SER DEBIDAMENTE NEUTRALIZADO El cord n de energia de ste aparato esta equipado con tres patas cable a tierra Utilice ste con un enchufe de pared de tres salidas a tierra para minimizar el peligro de choque el ctrico El cliente debe revisar el receptor de pared y el circuito por un electricista calificado para asegurarse que la recepci n esta debidamente neutralizada 32 Aire Acondicionador NO CORTE O REMUEVA LA TERCERA PATA GROUND DEL ENCHUFE A SITUACIONES EN LAS CUALES EL APARATO ES DESCONECTADO OCASIONALMENTE Debido al peligro potencial nosotros no recomendamos el uso de adaptadores Sin embargo si usted desea utilizar un adaptador una CONEXION TEMPORAL puede ser efectuada Utilice adaptadores UL disponibles en la mayoria de los estable cimientos de herramientas La pata mas grande del adaptador debe ser alineada con la pata mas grande del interruptor para asegurarse una
64. ucto si est instalado en un lugar inaccesible ESTA GARANT A SE OTORGA EN SUSTITUCI N O EXCLUSI N DE TODA OTRA GARANT A EXPRESA O IMPL CITA INCLUYENDO SIN LIMITAR CUALQUIER GARANT A DE CALIDAD O IDONEIDAD CON UN PROP SITO CONCRETO EN LA MEDIDA EN QUE CUALQUIER GARANT A IMPL CITA ES OBLIGADA POR LA LEY EST LIMITADA EN DURACI N AL PERIODO DE GARANT A YA MENCIONADO LA REPARACI N O REEMPLAZO DE PIEZAS SEG N LO ESTABLECIDO EN ESTA GARANT A ES EL NICO QUE PUEDE RECLAMAR EL CLIENTE NI EL FABRICANTE NI SU DISTRIBUIDOR EN LOS EE UU SE HACE RESPONSABLE DE CUALQUIER DA O DERIVADO INDIRECTO ESPECIAL O PENAL DE CUALQUIER NATURALEZA INCLUYENDO SIN LIMITACION LA P RDIDA DE INGRESOS O BENEFICIOS O CUALQUIER OTRO TIPO DE DA O A N BASADO EN UN CONTRATO SEA UN AGRAVIO O DE CUALQUIER OTRA MANERA ALGUNOS ESTADOS NO PERMITEN LA EXCLUSI N O LIMITACI N DE DA OS IMPREVISTOS O RESULTANTES O LIMITACIONES A LA DURACI N DE LAS GARANT AS IMPL CITAS POR LO QUE LA EXCLUSI N O LIMITACI N MENCIONADA ANTERIORMENTE NO SER APLICABLE AL USUARIO ESTA GARANT A LE OTORGA DERECHOS LEGALES ESPEC FICOS Y TAMBI N PUEDE TENER OTROS QUE VARIAR N DE UN ESTADO A OTRO COMO OBTENER EL SERVICIO DE ESTA GARANT A E INFORMACI N ADICIONAL Llame al 1 800 243 0000 o visite nuestra p gina web www lg com Direcci n de correo ordinario LG Customer Information Center ATTN CIC 201 James Record Road Huntsville AL 35824 LG Life s Good
65. val of the old wall sleeve and the installation of a new LGE Wall Sleeve If you decide to keep the existing wall sleeve you have to redirect the louvers at the back of the wall sleeve illustration The use of pliers is recommended If you DO NOT redirect you run the risk of poor performance or product failure This is not covered under the terms of the LGE warranty e Pick a location which will allow the conditioned air to blow into the area you want Good installation with special attention to the proper position of the unit will lessen the chance that service will be needed ITEMS IN INSTALLATION HARDWARE You may not need all parts in the kit Discard unused parts ITEM inches Qty 2634 X 1612 15946 X 138 X 13 g 671 8 X 198 X 25 32 5927 32 X 13 g X 13g Horizontal Insulation Strip 237 32 x 13g x 13 14 Support Block 13 4 X 198 X 45 16 Plastic grille Vertical insulation strip Around Insulation Strips Baffle 14 x 41 X 18 Shim 812X 1 X 34 Trim Frame Washer Screw Nuts Plastic Grille Rear HOW TO INSTALL Identify the existing wall sleeve before installing the unit from the listed below IAA ININ IN Brand Wall Sleeve Dimensions inches ran Width Height Depth White Westinghouse Frigidaire 25 1 2 15 1 4 L oF E fe Carrier 52F series General Electric 26 15 5 8 16 7 8 Hotpoint 7 5 17 1 8 Whirlpool 25 7 8 16 1 2 o
Download Pdf Manuals
Related Search
Related Contents
User manual Téléchager le catalogue tablettes 肩用フェーズドアレイコイル MJAJ− 107A Scorpion for Universities, Colleges & Schools Untitled - Saint Nom la Bretèche HI 151-02 - Hanna Instruments Portugal NEC A3842 User's Manual SERVICE MANUAL Tecumseh AE2425Z-AA3C Drawing Data Copyright © All rights reserved.
Failed to retrieve file