Home
        Cadet CBC103TCH Installation Guide
         Contents
1.                  ADJACENT WALL    Figure 4       INSTALLATION INSTRUCTIONS  continued     Part Two    After you have followed all instructions in Part One you are ready to install the heater assembly     CB103T Multi Volt    How do  configure the Multi Volt model CB103     SIA  Determine Supply Voltage  Heater must be connected to a GFCI protected branch circuit     Refer to wiring diagrams  and Figure 6 for desired voltage  Before  installing the heater  it is extremely important you verify the  heater is configured for the correct supply voltage  The Multi Volt  Com Pak Bathroom Heater is configured for 240 volt operation by  default  For 120 volt installation you must reconfigure the heater  wiring  Installing the heater without configuring for the correct  voltage will destroy the heater and void your warranty     How to determine the supply voltage     If replacing an existing heater  check the labels of the old heater  and replace using same voltage  For new construction  heater  wires must be configured to the same voltage as the supply wires   If you need assistance  consult a qualified electrician     SUE Select Proper Heater Voltage  For 240 volt configuration     The Multi Volt Com Pak Bathroom Heater is configured for 240  volt operation by default  Important  The red wire and its terminal  end are not connected in this configuration     For 120 volt Configuration     To configure heater for 120 volt  disconnect the blue wire from  terminal D and connect it to ter
2.   Los cables de suministro o del calentador que presentan cortocircuitos pueden ocasionar  chispas peligrosas  Revise el aislamiento de todos los cables de suministro y del calentador  para comprobar que no est  n da  ados  No reestablezca el cortacircuito sino hasta que se hayan  reparado todos los cortocircuitos el  ctricos    4  Reemplace el cortacircuito        El ventilador del  calentador funcio   na pero no env  a  aire caliente     1  Temperatura insuficiente del  elemento    2  Voltaje de suministro incorrecto    3  El elemento ha fallado      1  Espere unos momentos para que el elemento alcance la temperatura de funcionamiento     2  Compruebe que el voltaje de suministro coincida con la calificaci  n del calentador   3  Reemplace el elemento        El calentador no se  apaga     El calentador emite  humo o un olor a  quemado     1  La fuga de calor de la habitaci  n es  superior a la capacidad del calenta   dor     2  El termostato no funciona cor   rectamente  o bien el temporizador  supedit   el ajuste     1  Se han acumulado polvo  pelusas u  otros materiales dentro del calentador   2  Conexiones el  ctricas deficientes   o sueltas     1  Cierre las puertas y ventanas  Coloque aislamiento adicional  o instale un calentador de may   or vatiaje o m  ltiples calentadores si fuera necesario   Si su circuito tiene mayor capacidad      2  Espere que el temporizador termine su per  odo o bien g  relo en sentido contrario a las mane   cillas del reloj a    0     el temp
3.   nor authorizes anyone to assume for it  any other  obligation or liability in connection with its products other than as  set out herein     If you believe your Cadet product is defective  please contact  Cadet Manufacturing Co  at 855 CADET US  during the warrant  period  for instructions on how to have the repair or replacemen  processed  Warranty claims made after the warranty period has  expired will be denied  Products returned without authorization  will be refused     Parts and Service  Visit cadetheat com parts service for information on where to  obtain parts and service     Reduce Reuse Recycle   This product is made primarily of recyclable materials   You can reduce your carbon footprint by recycling this  product at the end of its useful life  Contact your local  recycling support center for further recycling instruc   ions                     Page 5    MAINTAINING YOUR HEATER                      Maintenance As Needed  or every six months minimum     WARNING  Before removing grill  turn the electrical power off at the main disconnect    panel  circuit breaker or fuse box   Lock or tag the main disconnect panel door to prevent  someone from accidentally turning the power on while you are working on the heater   Failure to do so could result in serious electrical shock  burns  or possible death      NWARNING  Any other service not detailed in this Owner s Guide should be performed by an autho   rized service representative     1  It is important that you verify p
4.  Built in Tim  r Built in Thermostat    125 8     32 0cm                         y       be 10    A  1 30m 25 4cm  Wall Can Bottom  19 Ye                laser  sam LISTED  TOOLS REQUIRED  e Utility Knife  e Phillips Screwdriver e  2  1   Wood Screws    7718   e Straight Screwdriver e  2  Insulated Wire Connectors  Poem e Wire Strippers e  1  Strain Relief Connector                SAVE THESE INSTRUCTIONS    cadetheat com Tel  855 CADET US PO Box 1675 Vancouver  WA 98668 1675 Page    IMPORTANT INSTRUCTIONS    A WARNING    When using electrical appliances  basic precautions should always be followed to reduce the risk of fire   electric shock  and injury to persons  including the following     1  Read all instructions before installing or using  this heater     2  A WARNING   Risk of Fire  This heater is hot when in use   Caution   High Temperature  Risk of Fire  Keep  electrical cords  drapery  furnishings  and other  combustibles at least 3 feet from the front of the  heater and 6 inches above and on both sides     3  A WARNING  Burn Hazard  To avoid burns  do not let bare skin  touch hot surfaces  Extreme caution is necessary  when any heater is used by or near children or  invalids and whenever the heater is left operating  and unattended     4  AWARNING A   Risk of Electrical Shock  Do not operate any  heater after it malfunctions  Disconnect power  at service panel and have heater inspected by a  qualified electrician before reusing     5  A WARNING  Do not use outdoors   
5.  ELECTRICAL CODES TO DETERMINE WHAT WORK MUST BE PERFORMED BY QUALIFIED  ELECTRICAL SERVICE PERSONNEL     1  Incorrect supply voltage    2  Overloaded circuit      3  A short circuit exists in the  supply or heater wiring      4  Defective circuit breaker      1  Insufficient element tempera   ture    2  Incorrect supply voltage     3  Element has failed      1  Heat loss from room is greater  than heater capacity      2  Thermostat is not functioning  properly  or setting has been  overridden by timer     1  Dust  lint or other matter has  accumulated inside heater    2  Poor or loose electrical  connections     1  Defective motor or internal  connection    2  Fan or motor jammed     1  Thermostat is set too low  or in  no heat position    2  Heater has tripped the manual  high temperature reset switch    3  Power not on at the circuit  breaker    4  Broken or poorly connected  wire s  to heater    5  Defective thermostat and or  timer     1  Dust  lint or other matter has    accumulated inside heater   2  Airflow is blocked     3  Fan or motor is jammed     4  None of the above        1  Verify that supply voltage matches the heater rating    2  The total amperage of all heaters on a branch circuit must not be more than  80  of the amperage rating of the circuit breaker and supply wire ratings  Use a  lower wattage heater  or reduce the number of heaters on the circuit    3  Shorted supply or heater wires may be accompanied by severe sparking   Inspect all supply and heater
6.  antes  de volver a usarlo    5  4  ADVERTENCIA   No lo use a la intemperie    6  Para desconectarlo  ponga los controles en  OFF  y apague la alimentaci  n del circuito del  calentador en el panel de desconexi  n principal     7  MADVERTENCIA A   Riesgo de electrocuci  n  No introduzca ni  permita que ingresen objetos en las aberturas  de la ventilaci  n o escape  ya que ello puede  causar electrocuci  n o incendio  o bien da  ar el  calentador     8    ADVERTENCIA   Riesgo de incendio  Para evitar posibles  incendios  no bloquee las tomas de aire ni el  escape de manera alguna     9  AADVERTENCIA   Podr  an producirse explosiones o incendios   Todo calentador contiene piezas que se calientan  y pueden producir arcos voltaicos o chispas   No lo use en   reas donde se utilice o almacene  gasolina  pintura o vapores o l  quidos inflamables     10  Use este calentador s  lo como se describe en  este manual  Todo otro uso no recomendado por  el fabricante puede causar incendios  descargas  el  ctricas o lesiones personales     11  El calentador debe instalarse correctamente  antes de usarlo    12  A ADVERTENCIA A   Riesgo de electrocuci  n e incendio  No lo opere  sin la rejilla     13  Conserve estas instrucciones     Diagramas de cableado       CB103T Voltaje M  ltiple CB132T Multi Vatiaje    Suministro de Alimentaci  n de 240 Voltios Suministro de Alimentaci  n de 120 Voltios    Suministro de Alimentaci  n de 240 208 Voltios             TEMPORIZADOR       TEMPORIZADOR    TERM
7.  consulte  a un t  cnico electricista calificado     mse  Seleccione el voltaje adecuado del calentador   Para la configuraci  n de 240 voltios    El calentador Com Pak Bath est   configurada para operar a 240   voltios de manera predeterminada    Importante  El alambre rojo y  su extremo terminal no est  n conectados en esta configuraci  n     Para la configuraci  n de 120 voltios    A fin de configurar el calentador para 120 voltios  desconecte  el alambre azul del terminal D y con  ctelo al terminal A  Luego  conecte el alambre rojo suelto al terminal D     Configuraci  n Correcta de 240 Voltios       Configuraci  n Correcta de 120 Voltios                                                 Alambre Azul             Alambre Blanco     gt                              Alambre Blanco                     Alambre Negro  gt   Alambre Negro        Alambre Rojo i    Alambre Roja     Alambre Azul                  Figura 6  Contin  e con el PASO 3        CB132T Multi Vatiaje      C  mo se configura Vatiaje M  ltiple modelo CB132     Configuraci  n de cableado del elemento de  PASO 1 vatiaje m  ltiple   El calentador se debe conectar a un circuito derivado con protec   ci  n GFCI     Consulte la tabla de Figura 5 para seleccionar el vatiaje correcto  necesario  y los terminales del elemento que se han de usar           240 208V  CONFIGURACI  N DE ALAMBRES    800 600   Desconecte y corte el conector AZUL del terminal  C  Cubra el extremo del alambre suelto con cinta  para uso el  ctrico  M
8.  mediante los  orificios que vienen en la c  mara  Como alternativa  se puede  a  adir la cu  a de caucho suministrada al costado de la c  mara  para cuadrarla con el puntal  Consulte las Figuras 1 y 2      Contin  e con la Parte Dos        PARED ADYACENTE       Figura 4       P  gina 9    INSTRUCCIONES PARA LA INSTALACION  continuaci  n        Parte Dos    Una vez que ha seguido todas las instrucciones en la Parte Uno  ya est   preparado para instalar el conjunto del  calentador     CB103T Voltaje Multiple      C  mo se configura Multi Voltaje modelo CB 103     ASTON  Determine el voltaje del suministro    El calentador se debe conectar a un circuito derivado con protec   ci  n GFCI     Antes de instalar el calentador  es extremadamente importante  verificar que est   configurado para el voltaje de suministro cor   recto  El calentador Com Pak Bath est   configurado de manera  predeterminada para funcionar a 240 voltios  Para la instalaci  n  a 120 voltios  se debe reconfigurar el cableado del calentador   Instalar el calentador sin configurarlo para el voltaje correcto  destruir   el aparato e invalidar   la garant  a     C  mo determinar el voltaje de suministro    Si va a reemplazar un calentador existente  revise las etiquetas  del calentador antiguo y sustit  yalo por otro del mismo voltaje   Para una construcci  n nueva  los alambres del calentador se  deben configurar de modo que coincidan con el voltaje de los  alambres del suministro del inmueble  Si necesita ayuda 
9.  to a higher temperature until heater operates  See Problem   5 if the problem persists    2  Press the manual reset button  See    OPERATING INSTRUCTIONS     section      3  Turn on the correct circuit breaker in the main disconnect panel     4  Turn off power at circuit breaker  Check supply wire continuity and proper con   nection to heater wires    5  Repair or replace the heater  The entire heater  or any of its components may  be checked for continuity to determine the cause of any problem     1  Clean heater  See    MAINTAINING YOUR HEATER    section for instructions      2  Remove obstruction  Maintain a minimum distance of 6 inches from adjacent  surfaces  4  inches from the floor  and 3 feet for furniture or other objects placed  directly in front of the heater    3  Remove obstruction  and press heater manual reset button  See    OPERATING  INSTRUCTIONS    section     4  Replace heater assembly       2015 Cadet PrintedinUSA Rev 06 15  720050    CADETS         Beneficios En Las Que Puede    Confiar    e La Mejor Alternativa para Su Ba  o    Calor r  pido donde m  s lo necesita  Incluye temporizador de 60 minutos y termostato  F  cil de instalar      Nuestro elemento de m  xima resistencia brinda  una agradable calidez durante muchos a  os de uso    confiable    e Componentes con sentido com  n dise  ados pen     sando en    usted    Sin bordes filosos    Resistentes a la corrosi  n  C  mara de pared f  cil de instalar      Seguro para usted y su familia       Tranqu
10.  wiring insulation for damage  Do not reset the circuit  breaker until all electrical shorts have been repaired    4  Replace the circuit breaker     1  Allow a few moments for element to reach operating temperature     2  Verify that supply voltage matches the heater rating   3  Replace element     1  Close doors and windows  Provide additional insulation  or install a higher  wattage heater or multiple heaters if necessary   If your circuit is rated for more  capacity     2  Wait for the timer to time out or turn the timer counterclockwise to    0     The timer  overrides the thermostat setting   If heater continues to run  adjust thermostat to  its lowest setting  If heater continues to run  allow two minutes for thermostat to  respond  the thermostat requires replacement     1  Clean heater  see    MAINTAINING YOUR HEATER    section above for instruc   tions     2  Turn off power at circuit breaker  Inspect all supply and heater wire connections  to make sure nothing is loose or poorly connected  Secure or reconnect all loose  connections  Do not reset circuit breaker until all connections have been checked  and repaired     1  Heater or fan motor requires replacement     2  Remove obstruction and press heater reset button  after allowing the unit to  cool   Test heater operation   if reset button has been pressed  be sure to listen  and feel for a click indicating it has been reset   but heater does not run  heater  requires repair or replacement     1  Adjust thermostat
11. 6  To disconnect heater  turn controls to off  and    turn off power to heater circuit at main disconnect  panel     7  AWARNING A   Risk of Electrical Shock  Do not insert or allow  foreign objects to enter any ventilation or exhaust  opening as this may cause an electric shock or  fire  or damage the heater     8  AWARNING  Risk of Fire  To prevent a possible fire  do not  block air intakes or exhaust in any manner     9    WARNING   Fire or explosion may occur  A heater has hot and  arcing or sparking parts inside  Do not use it in  areas where gasoline  paint  or flammable vapors  or liquids are used or stored     10  Use this heater only as described in this  manual  Any other use not recommended by the  manufacturer may cause fire  electrical shock  or  injury to persons    11  The heater must be properly installed before  it is used     12  AAWARNINGA   Risk of Electrical Shock and Fire  Do not operate  without grill     13  Save these instructions     Wiring Diagrams    CB103T Multi Volt CB132T Multi Watt    240 208 Volt Power Supply                                a a    240 Volt Power Supply 120 Volt Power Supply  TIMER THERMOSTAT ae oot ah JUMPER WITH  3 6 1 VV VV   SPARETERMINAL    MER CONNECTOR  a  i SHORTING BAR al         6       T 4   JUMPER WITH THERMOSTAT   INSULATED Q D  HEATING ELEMENT  CONNECTOR    MANUAL  RESET HIGH  TEMPERATURE  LIMIT    MANUAL  RESET HIGH    TEMPERATURE     LIMIT             4 E MOTOR La e             INSULATEDQD  D ______  A   SPARE TE
12. C A D E T cp Com Pak Bath Heater    Owner   s Guide  Benefits You Can Depend On                e Best Choice for Your Bathroom Com Pak Bath Multi Volt Model  Quick heat where you need it most        Line Model with  Includes 60 minute timer and thermostat Weltau   Thermostat  1  Watts Amps  Easy to install and Timer  f   120 CB1037 1000 8 3  e Our sturdiest element provides cozy warmth for aso a   000 ia                years of reliable use     Common sense components designed with you in  mind   No sharp edges       Com Pak Bath Multi Watt Model                                  k a Line Model with  Corrosion resistant Voltage Thermostat  1  Watts Amps  Easy to install wall can and Timer  500 2 1  e Safe for you and your family o 240  2  CB1327 200    Peace of mind with automatic high tempera  o    ture shutoff feature E        1  Standard built in thermostat is single pole with no heat position when turned       Your Cadet heater has been thoroughly tested and completely counterclockwise  Built in 60 minute timer overrides thermostat for instant  is guaranteed with a limited 3 year warranty warmth    2  240 volt models can be used at 208 volts  Wattage equals 75  of 240v rated  e Two models for multiple room sizes and multiple wattage     voltage applications       Com Pak Bath Models    with Built In Thermostat  Wall Thermostat Not Required    ESO    Sos     Reset Button  o  i    Rating Label 00o 00o          Q                         Side Grill Front Wall Can Side         
13. Consulte la Figura  3   Empalme el alambre de conexi  n  a tierra del suministro al tornillo de  puesta a tierra que viene en la c  mara  de pared     Contin  e con la Parte Dos        CABLE DEL SUMINISTRO    DESTAPADERO   GIRE PARA  IRARLO     S TORNILLO DE  CONECTOR DE PUESTA A TIERRA  ALIVIO DE TENSI  N         C  mo se instala el calentador en una pared existente     TO  Corte un orificio en la pared    La distancia MINIMA REQUERIDA es de 6 pulgadas desde las  superficies adyacentes y 4  pulgadas desde el piso  Consulte la  Figura 4   Sin embargo  Cadet recomienda 12 pulgadas desde las  superficies adyacentes y el piso para lograr un rendimiento m  s  prolongado y limpio  Si se instalan varios calentadores  deje al  menos tres pies entre ellos     Corte un orificio de 8 pulgadas de ancho por 10  de alto al lado  del puntal de la pared     OY  Instalaci  n de los cables de suministro    Dirija el cable de suministro desde el cortacircuito GFCI a la  c  mara de pared  Quite un destapadero y fije el cable de sum   inistro mediante un conector de alivio de tensi  n  no incluidos   dejando 6 pulgadas de cable de conexi  n  Consulte la Figura 3   Empalme el alambre de conexi  n a tierra del suministro al tornillo  de puesta a tierra que viene en la c  mara de pared       OJ  Montaje de la c  mara de pared    Inserte la c  mara de pared en la abertura  manteni  ndola  alineada con la superficie de la pared  Asegure la c  mara al  puntal de la pared con 2 tornillos  no incluidos 
14. D             e Cuchillo Multiuso   e  2  Tornillos de 172  para Madera  e  2  Conectores de Alambres   e  1  Conector de Alivio de Tensi  n    HERRAMIENTAS NECESARIAS   e Destornillador Phillips   e Destornillador Plano   e Pelacables          CONSERVE ESTAS INSTRUCCIONES       cadetheat com Tel  855 CADET US PO Box 1675 Vancouver  WA 98668 1675    P  gina 7    INSTRUCCIONES IMPORTANTES      MADVERTENCIA    Al utilizar artefactos el  ctricos  siempre se deben adoptar precauciones b  sicas para reducir el riesgo  de incendios  electrocuci  n y lesiones personales  incluyendo lo siguiente     1  Lea todas las instrucciones antes de instalar o  usar este calentador     2  A ADVERTENCIA   Riesgo de incendio  Este calentador se calienta  mucho cuando est   en uso  Precauci  n     Alta  temperatura  Riesgo de incendio  Mantenga los  cables el  ctricos  cortinas  muebles  y dem  s  materiales combustibles a por lo menos 3 pies por  delante y a 6 pulgadas por encima y por ambos  costados del calentador     3  A ADVERTENCIA   Riesgo de quemaduras  Para evitar quemaduras   no lo toque con su piel descubierta  Tenga  mucho cuidado cuando alg  n tipo de calentador  sea usado por o cerca de ni  os o de personas  inv  lidas  y cada vez que lo deje funcionando sin  vigilancia    4   A ADVERTENCIA A   Riesgo de electrocuci  n  No opere ning  n  calentador despu  s de una aver  a  Desconecte  la alimentaci  n en el panel de servicio y pida a un  t  cnico electricista calificado que lo revise
15. GFCI circuit breaker to the wall can   Remove a knockout from the wall can and attach the supply wire  with a strain relief connector  not included  leaving a minimum  of 6 inches wire lead  Connect supply ground wire to grounding  screw in wall can  See Figure 3      Proceed to Part Two     How do l install in an existing wall     SAA  Cut A Hole In The Wall   REQUIRED MINIMUM distance of 6 inches from adjacent  surfaces and 4  inches from the floor  See Figure 4   However   Cadet recommends 12 inches from adjacent surfaces and floor for  longer and cleaner performance  Heaters must be spaced at least  3 feet apart     Cut a hole 8 inches wide by 10  inches high next to a wall stud     SY Route Supply Wires    Route supply wire from the GFCI circuit  breaker to the wall can  Remove a  knockout from the wall can and attach  the supply wire with a strain relief con   nector  not included  leaving a minimum  of 6 inches wire lead  Connect supply  ground wire to grounding screw in wall  can  See Figure 3      Figure 3       KNOCK OUT   TWIST TO REMOVE     STRAIN RELIEF  CONNECTOR    SCREW    132  Mount The Wall Can    Insert wall can into opening  keeping front of the wall can flush  with the finished wall surface  Secure the wall can to the stud with  2 screws  not included  through holes provided in the wall can  As  an option  the rubber shim provided may be attached to the side  of the wall can to square the wall can to the stud  See Figures 1  and 2      Proceed to Part Two
16. INAL LIBRE PAA  EN LA BARRA DE         CORTOCIRCUITO     DEL ELEMENTO    c  f T 4  o ne 3 TERMOSTATO    c  ELEMENTO CALENTADOR                             R  PIDA AISLADA          INTERRUPTOI    R  L  MITE DE ALTA  10   TEMPERATURA DE Br   REGLAJE MANUAL          ee                    MOTOR             IE DESCONEXI  N  RAPIDAAISLADA    PUENTE CON CONECTOR TERMINAL LIBRE TERMOSTATO  EN LA BARRA DE  p DAAI aa y A CORTOCIRCUITO 3 6  DEL ELEMENTO Q a  ae Pess 2 c  1 4    L2             INTERRUPTOR  L  MITE DE ALTA  TEMPERATURA  DE REGLAJE  MANUAL    D       MOTOR    L1 L2  SUMINISTRO DE  ALIMENTACI  N  DE 240 208                CONSERVE ESTAS INSTRUCCIONES    cadetheat com Tel  855 CADET US PO Box 1675 Vancouver  WA 98668 1675    P  gina 8    INSTRUCCIONES PARA LA INSTALACION    1  ADVERTENCIA  Verifique que todos los cables de suministro el  c   trico sean del mismo voltaje que el calentador   2  Si va a reemplazar un calentador existente  re   vise la etiqueta del calentador antiguo   3  Todo trabajo y materiales el  ctricos deben  cumplir con el C  digo El  ctrico Nacional     NEC      por su sigla en ingl  s   con la Ley de Seguridad  y Salud Ocupacional   OSHA     por su sigla en in   l  s  y con todos los c  digos estatales y locales     Si se debe instalar un nuevo circuito o se  necesita informaci  n adicional sobre el cableado   consulte a un electricista calificado   5  Use conductores de cobre solamente   6  A ADVERTENCIA A  Riesgo de electrocuci  n  NO instale el cale
17. LICITA           8  EN CASO DE QUE CADET DECIDA REEMPLAZAR ALGUNA PIEZA  DEL PRODUCTO CADET  LOS REPUESTOS SE REGIRAN POR LAS  MISMAS GARANTIAS DEL PRODUCTO  LA INSTALACION O RE   EMPLAZO DE LOS REPUESTOS NO MODIFICA NI PROLONGA LAS  GARANTIAS VIGENTES  EL REEMPLAZO O REPARACION DE TODO  PRODUCTO O PIEZA CADET NO ORIGINA NINGUN TIPO DE NUEVA  GARANTIA    9  Estas garantias le otorgan derechos legales espec  ficos y es posible  que usted tenga otros derechos que var  en de un estado a otro  Cadet  no asume ni autoriza a nadie que lo haga en su nombre  ninguna otra  obligaci  n o responsabilidad en relaci  n con sus productos que no sean  las que se establecen en este documento     Si durante el per  odo de garant  a usted considera que su producto Cadet  presenta defectos  comun  quese con Cadet Manufacturing Co  llamando  al 855 CADET US para obtener instrucciones sobre c  mo tramitar la  reparaci  n o el reemplazo del producto  Los reclamos de garant  a pre   sentados despu  s de la finalizaci  n del per  odo no ser  n acogidos  Los  productos que se devuelvan sin autorizaci  n ser  n rechazados     Repuestos y Servicio  En cadetheat com parts service encontrar   informaci  n sobre d  nde  obtener repuestos y servicio     Reduzca Reutilice Recicle   Este producto est   hecho principalmente de materiales reci   clables  Puede reducir la cantidad de carbono que contribuye  al medio ambiente reciclando este producto al t  rmino de su  vida   til  Comun  quese con su centro loca
18. RMINAL  TO  ON ELEMENT  1 SHORTING BAR  PE              AAA                         SAVE THESE INSTRUCTIONS    cadetheat com Tel  855 CADET US PO Box 1675 Vancouver  WA 98668 1675    Page 2    INSTALLATION INSTRUCTIONS    1     WARNING  Verify that the electrical supply wires are the same  voltage as the heater   2  If replacing an existing heater  check the label  of the old heater   3  All electrical work and materials must comply  with the National Electric Code  NEC   the Occu   pational Safety and Health Act  OSHA   and all  state and local codes   4  If you need to install a new circuit or need addi   tional wiring information  consult a qualified elec   trician   5  Use copper conductors only   6  A WARNING A  Risk of Electrical Shock  DO NOT install the heat   er directly above bathtub or sink  DO NOT install  in shower stall area  Manufacturer recommends a  minimum 2 foot clearance    7  Heater must be installed in a wall can    Model CB Wall Can CC    Part One    8  A WARNING   Risk of Fire  DO NOT install the heater in a floor   in the ceiling  below a towel bar  behind a door   or anywhere the air discharge may be blocked in  any manner    9    AWARNING   Fire or Explosion May Occur  A heater has hot  and arcing or sparking parts inside  Do not use it  in areas where gasoline  paint  or flammable va   pors or liquids are used or stored    10  A WARNING A   Risk of Electrical Shock  Connect grounding lead  to grounding screw provided  Keep all foreign ob   jects ou
19. ed   to open the heater circuit and stop the  electrical current flow when excessive  operating temperatures are detected   The problem must be assessed and the  limit must be reset to resume operation                 Resetting the Manual Reset Limit Control       Resetting the Manual Reset Temperature Limit Control    If the manual reset limit control has opened the heater circuit due to excessive operating  temperatures  the heater will not work until the manual reset limit button is pressed     After allowing the unit to cool for at least 10 minutes and resolving the problem causing the limit  to trip  typically the heater is blocked or needs cleaning see Maintenance Instructions   use a  narrow object such as a ball point pen to access the manual reset button through the upper   left center section of the heater grill  Press FIRMLY and be sure to listen and feel for a click   indicating it has been reset                          Manual 3  Reset  Limit A  Button  o    e0  0   O    Warrant        For more effective and safer operation and to prolong the life of  the heater  read the Owner   s Guide and follow the maintenance  instructions  Failure to properly maintain the heater will void any  warranty and may cause the heater to function improperly  War   ranties are non transferable and apply to original consumer only   Warranty terms are set out below     LIMITED THREE YEAR WARRANTY  Cadet will repair or re   place any Com Pak Bath  CB  heater found to be defective withi
20. esentante de servicio autorizado        C  mo hacer funcionar el calentador  Con el termostato incorporado     la derecha      del reloj  G  rela en sentido de las manecillas del reloj para aumentarla     incorporado   Con el temporizador incorporado        control del calentador volver   al ajuste anterior del termostato     1  Una vez que se haya realizado la instalaci  n y reestablecido la energ  a el  ctrica  gire  totalmente la perilla del termostato en el sentido de las manecillas del reloj   El termostato est   a    2  Cuando la habitaci  n haya alcanzado un nivel c  modo  gire la perilla del termostato en  sentido contrario a las manecillas del reloj hasta que el calentador se apague  El calentador se  encender   y apagar   autom  ticamente seg  n esta temperatura preestablecida     3  Para reducir la temperatura del ambiente  gire la perilla en sentido contrario a las manecillas     Nota  Si la perilla del termostato se gira completamente en el sentido contrario a las manecillas  del reloj  quedar   en la posici  n de sin calor  pero a  n se puede supeditar por el temporizador    4  Para operar el calentador con el temporizador  encienda este   ltimo la cantidad de los  minutos que desee   El temporizador est   a la izquierda y se representa por el s  mbolo     Los  n  meros indican minutos   El calentador permanecer   encendido hasta que acabe el per  odo  el    Acerca del control de limite de  temperatura de reglaje manual   El calentador est   protegido por un con
21. ga la rejilla     4  Lave la rejilla con agua caliente y jab  n  y s  quela     5  Mientras sujeta el ventilador  para evitar que se da  e o tuer   za   utilice una secadora o una aspiradora en el ciclo de soplado  para quitar la suciedad en el elemento superior  sin tocarlo      6  Aspire el   rea del ventilador sin tocar los elementos   7  No lubrique el motor     8  Vuelva a instalar la rejilla y fijela con los tornillos  Vuelva a  colocar las perillas del termostato y el temporizador     9  Coloque el termostato en la graduaci  n deseada     10  Vuelva a conectar la alimentaci  n en el panel de desconex   i  n principal     Tabla de resoluci  n de problemas     CONSULTE LOS C  DIGOS EL  CTRICOS LOCALES PARA DETERMINAR QU   TRABAJOS DEBEN SER  REALIZADOS POR PERSONAL DE SERVICIO ELECTRICO CALIFICADO     intoma    El interruptor se  disyunta inmediata   mente al encend   erse el calentador     Problema    1  Voltaje de suministro incorrecto    2  Circuito sobrecargado      3  Hay un cortocircuito en los cables  de suministro o del calentador      4  Cortacircuito defectuoso      olucion    1  Compruebe que el voltaje de suministro coincida con la calificaci  n del calentador    2  El amperaje total de todos los calentadores en un circuito de rama no debe sobrepasar el 80   de la calificaci  n de amperaje del cortacircuito y de las calificaciones de los cables de suminis   tro  Utilice un calentador de vatiaje inferior o reduzca la cantidad de calentadores en el circuito   3
22. ilidad gracias a la funci  n de apagado    autom  tico por alta temperatura      Su calentador Com Pak Bath ha sido completa   mente probado y cuenta con una garant  a limitada  de 3 a  os    e Dos modelos para diversos tama  os de habita   ciones y aplicaciones con m  ltiples voltajes    El Calentador Com Pak Bath    Gu  a Para el Propietario       Modelo Com Pak Bath de Voltaje M  ltiple          z Modelo con  viele Termostato  1  y Vatios Amps  Temporizador  120 1000 8 3  A  CB103T  240  2  1000 4 2                      Modelo Com Pak Bath de Multi Vatiaje                   eel Termostato     y Vatios Amps  Temporizador  500 2 1  240  2  CB132T 800 3 3  1300 5 4                      Costado    Y          Rejilla Frente    C  mara de  pared costado                         10          1 3cm          25 4cm    C  mara de pared inferior  1  14      ascm   32cm         1  Termostato incorporado es de polo   nico con una posici  n sin calor cuando se  gira completamente en sentido contrario a las manecillas del reloj  El temporizador  incorporado de 60 minutos supedita el termostato para brindar calor instantaneo    2  Los modelos de 240 voltios pueden usarse a 208 voltios  El vatiaje es igual al  75  de la potencia nominal de 240 v     Com Pak Bath con  Termostato Incorporado y  Temporizador Incorporado    No Requieren Termostato Mural    Bot  n de L  mite A    Reglaje Manual                      Etiqueta Calificaci  n    Temporizador Incorporado Termostato Incorporado    LISTE
23. l de reciclaje para  obtener mayores instrucciones al respecto          P  gina 11    MANTENIMIENTO DEL CALENTADOR    Mantenimiento Seg  n sea necesario  o cada seis meses como m  nimo           APAGADO             ADVERTENCIA  Desconecte la electricidad en el panel de desconexi  n principal   caja de cortacircuitos o fusibles  y trabe o coloque un cartel en la puerta del panel  de desconexi  n principal para evitar que alguien vuelva a conectar la energ  a  mientras se est   trabajando en el calentador  De lo contrario podr  an producirse  graves golpes el  ctricos  quemaduras e incluso la muerte        ADVERTENCIA  Toda otra labor no detallada en esta Gu  a para el propietario la debe efectuar un  representante de servicio autorizado     ntes de proceder  es importante que usted verifique que se  haya desconectado la alimentaci  n y que el calentador no reciba  energ  a  Los cortacircuitos no suelen estar correctamente mar   cados  y apagar el incorrecto podr  a significar que sigue fluyendo  electricidad al calentador  aun cuando   ste parezca no estar  funcionando  Si no se siente c  modo al trabajar con artefactos  el  ctricos  no est   en condiciones de acatar estas pautas o no  cuenta con los equipos necesarios  solicite los servicios de un    t  cnico electricista calificado     2  Una vez que verifique que se ha apagado la alimentaci  n    correctamente  prosiga con el paso siguiente     3  Retire las perillas del termostato y el temporizador  los tornillos  y extrai
24. minal A  Then connect the loose  red wire to terminal D     Correct 240 Volt Configuration    Correct 120 Volt Configuration                                                          White Wire     gt                              White Wire     gt                  CS    Black Wire     gt     Black Wire       lt    Red Wire     lt        Red Wire          Blue Wire            Figure 6  Proceed to STEP 3     How do l insert the heater assembly into the wall can   SUSE Install Heater Assembly        CB132T Multi Watt    How do  configure the Multi Watt model CB132     SHa Multi Watt Element Wiring Configuration  Heater must be connected to a GFCI protected branch circuit     Use the table in Figure 5 to select the correct wattage required   and the element terminals to be used     y  240 208V WIRE CONFIGURATION    800 600   Disconnect and cut BLUE connector from terminal  C  Wrap loose wire end with electrical tape  Move  YELLOW connector at terminal B to the C terminal     500 375   Cut wire with BLUE connector at terminal C  Wrap  loose wire end with electrical tape     Factory set at 1300 Watts  DO NOT DISCONNECT THE YELLOW CONNECTOR FROM TERMINAL  A     Figure 5         i  2  E     a  Wi  m  D  Ww  a          Proceed to STEP 3                         O  Figure 7 Multi Volt    Figure 8 Multi Watt   Model CB103 shown      Model CB132 shown     Turn heater assembly upside down  element down with motor facing up   Connect the supply wires to the heater wires with wire con   necto
25. n  hree years after the date of purchase     These warranties do not apply    1  Damage occurs to the product through improper installation or   incorrect supply vage   2  Damage occurs to the product through improper maintenance    misuse  abuse  accident  or alteration    3  The product is serviced by anyone other than Cadet    4  If ihe date of manufacture of the product cannot be deter    mined    E    He product is damaged during shipping through no fault of  adet    6  The use of unauthorized accessories or unauthorized compo    nents constitutes an alteration and voids all warranties  Refer to   Cadet website or call customer service at 855 CADET US for list   of authorized accessories and components    7  CADET S WARRANTY IS LIMITED TO REPAIR OR RE    PLACEMENT AS SET OUT HEREIN  CADET SHALL NOT BE   LIABLE FOR DAMAGES SUCH AS PROPERTY DAMAGE OR   FOR CONSEQUENTIAL DAMAGES AND OR INCIDENTAL EX    PENSES RESULTING FROM BREACH OF THESE WRITTEN   WARRANTIES OR ANY EXPRESS OR IMPLIED WARRANTY             8  IN THE EVENT CADET ELECTS TO REPLACE ANY PART  OF YOUR CADET PRODUCT  THE REPLACEMENT PARTS  ARE SUBJECT TO THE SAME WARRANTIES AS THE PROD   UCT  THE INSTALLATION OF REPLACEMENT PARTS DOES  NOT MODIFY OR EXTEND THE UNDERLYING WARRANTIES   REPLACEMENT OR REPAIR OF ANY CADET PRODUCT OR  PART DOES NOT CREATE ANY NEW WARRANTIES   9  These warranties give you specific legal rights  and_you may  also have other rights which vary from state to state  Cadet nei   ther assumes
26. nta   dor directamente sobre la tina o lavamanos  NO  lo instale en la zona de la ducha  el fabricante  recomienda un espacio m  nimo de 2 pies    7  El calentador debe instalarse en una c  mara  de pared   Modelo CB C  mara de Pared CC    Parte Uno    8  MA ADVERTENCIA   Riesgo de incendio  NO instale el calentador en  el piso  en el cielo raso  bajo la barra de la toalla   detr  s de una puerta ni en ning  n otro lugar en  el que la descarga de aire se pueda bloquear de  alguna manera    9    ADVERTENCIA   Podr  an producirse explosiones o incendios   Todo calentador contiene piezas que se calientan  y pueden producir arcos voltaicos o chispas  No  o use en   reas donde se utilice o almacene gas   olina  pintura o vapores o l  quidos inflamables   10 A ADVERTENCIA A   Riesgo de electrocuci  n  Conecte el conductor a  tierra al tornillo de puesta a tierra suministrado   Evite que entren objetos extra  os al calentador   11 M ADVERTENCIA   Riesgo de incendio  Este calentador se calienta  mucho cuando est   en uso  Precauci  n     Alta  temperatura  Riesgo de incendio  Mantenga los  cables el  ctricos  cortinas  muebles  em  s  materiales combustibles a por lo menos 3 pies por  delante y a 6 pulgadas por encima y por ambos  costados del calentador     UBICACI  N  Instale verticalmente el calentador Com Pak Bath  Modelo CB   No se ha aprobado el uso horizontal del calentador ni    tampoco su montaje en cielo raso     CONTROLES  Un termostato incorporado y temporizador de 60 min
27. orizador supedita el ajuste del termostato   Si el calentador contin  a  funcionando  fijelo en el ajuste m  nimo  Si el calentador contin  a funcionando  espere un poco   para que el termostato tenga tiempo de responder al ajuste   el termostato se debe reemplazar     1  Limpie el calentador  consulte las instrucciones en la secci  n    MANTENIMIENTO DEL  CALENTADOR        2  Desconecte la energ  a en el cortacircuito  Inspeccione todas las conexiones de alambres  del suministro y del calentador para cerciorarse de que no haya nada suelto ni mal conectado   Afiance o reconecte todas las conexiones sueltas  No restablezca el cortacircuito sino hasta  haber revisado y reparado todas las conexiones        El elemento calien   ta por un momento  sin que gire el  ventilador y luego  deja de calentar  inmediatamente     1  Motor o conexi  n interna defectu   osos    2  Ventilador o motor trabado     1  Debe reemplazarse el calentador o el motor del ventilador     2  Quite la obstrucci  n y oprima el bot  n de reglaje del calentador  despu  s de dejar que la uni   dad se enfr  e   Pruebe el funcionamiento del calentador   si el bot  n de reglaje se ha oprimido   aseg  rese de escuchar y de sentir un chasquido indicando que se ha restablecido   pero el  calentador no funciona  el calentador debe repararse o reemplazarse        El calentador no  funciona     1  El termostato est   fijado muy bajo   o bien en la posici  n de sin calor    2  El calentador ha hecho saltar el  interrupto
28. ower has been turned off and no  power is going to the heater before proceeding  Circuit breakers  are often not marked correctly and turning the wrong breaker off  could mean electricity is flowing to the heater  even if the heater  does not appear to be working  If you are uncomfortable working  with electrical appliances  unable to follow these guidelines  or do  not have the necessary equipment  consult a qualified electrician     2  Once you verify the power has been turned off correctly  pro   ceed to the next step     3  Remove thermostat and timer knobs  screws and take off grill     4  Wash grill with hot soapy water and dry     Breaker trips  immediately upon  energizing heater     Heater fan  operates  but does  not discharge warm  air     Heater will not shut  off     Heater discharges  smoke or emits a  burnt odor     Element heats for   a moment without  the fan turning  then  immediately stops  heating     Heater does not  run     Heater continually  trips the manual  reset temperature  limit control     Page 6    5  While holding fan  to avoid damage or bending   use a hair dryer  or vacuum on blow cycle to blow debris through the top element   do not touch element      6  Vacuum fan area without touching the elements   7  Do not lubricate motor     8  Replace grill and secure with screws  Replace thermostat and  timer knobs     9  Turn thermostat to desired setting   10  Turn power back on at the main disconnect panel     Troubleshooting Chart   CONSULT LOCAL
29. r de reglaje de alta tempera   tura    3  La energ  a no est   conectada en el  cortacircuito    4  El o los cables que van al calenta   dor est  n rotos o mal conectados    5  Termostato y o temporizador  defectuosos     1  Ajuste el termostato a una temperatura m  s alta hasta que el calentador funcione  vea el  Problema No  5 si la dificultad persiste      2  Oprima el bot  n de reglaje manual  vea las instrucciones en la secci  n    OPERACI  N DEL  CALENTADOR         3  Conecte el cortacircuito correcto en el panel de desconexi  n principal     4  Desconecte la energ  a en el cortacircuito  Revise la continuidad del cable de suministro y la  conexi  n apropiada a los cables del calentador    5  Repare o reemplace el calentador  Se debe revisar la continuidad de todo el calentador  o bien  de sus componentes a fin de determinar la causa de cualquier problema        El calentador  disyunta continu   amente el control  limitador de tem   peratura de reglaje  manual           1  Se han acumulado polvo  pelusas u  otros materiales dentro del calentador   2  El flujo de aire est   bloqueado     3  El ventilador o el motor est    trabado   4  Ninguna de las anteriores        1  Limpie el calentador  vea las instrucciones en la secci  n    MANTENIMIENTO DEL CALENTA   DOR        2  Retire la obstrucci  n  Mantenga una distancia m  nima de 6 pulgadas de las superficies  adyacentes  4  pulgadas del piso y 3 pies de los muebles u otros objetos situados directamente  delante del calen
30. r panel before removing grill    7  Use a hair dryer or vacuum on blow cycle to  blow debris through the top element  do not touch  element     8  Install the grill before turning on power     A  WARNING  Any other service not detailed in  this Owner   s Guide should be performed by an  authorized service representative        How to operate your heater  With the built in thermostat     fully clockwise   The thermostat is on the right    temperature    room temperature  turn the knob clockwise     tion  but can still be overridden by the built in timer   With the built in timer        stat setting     1  Once installation is complete and power has been restored  turn the thermostat knob    2  When the room reaches your comfort level  turn the thermostat knob counterclock   wise until the heater turns off  The heater will automatically cycle around this preset    3  To reduce the room temperature  turn the knob counterclockwise  To increase the     Note  If thermostat knob is turned fully counterclockwise  it will be in the no heat posi     4  To operate the heater with the timer  turn timer to desired minutes   The timer is on  the left and represented by the symbol        The numbers indicate minutes   Heater will  remain on until time expires  then control of the heater will return to the previous thermo     About the Manual Reset  Temperature Limit Control    The heater is protected by a tempera   ture limiting control  The manual reset  temperature limit control is design
31. rs  not included    See Figures 7 and 8   Now rotate the heater so the element and the fan are facing up  The element should be    at the top     Insert the bottom edge of the heater assembly into the half round slots in the bottom lip of the wall can  See Figure 9    IMPORTANT   Push wires into bottom of wall can during insertion  Be sure that supply wires are not caught between motor and wall can   Attach    assembly at top with screw provided     Note  Warranty is void if any material is sprayed on the element  or blower  Use a paint mask to cover any exposed areas of the  heater if walls are to be textured or painted     SAS Install Grill    Secure grill with the screws provided  Slide thermostat knob onto  right control shaft extending through the grill and the timer knob  onto the left shaft  Turn power on at the main disconnect panel     Page 4             Figure 9          OPERATING INSTRUCTIONS    ANWARNING Risk of Electrical Shock and Fire   The heater must be properly installed before it is  used    1  Do not operate without grill    2  Keep electrical cords  drapery  furnishings and  other combustibles at least 3 feet away from the  front of the heater and 6 inches away from the  sides    3  Do not tamper with the over temperature limit  control    4  If the heater over temperature limit trips more  than once per day  the heater must be replaced     5  Clean heater at least every six months    6  After allowing the heater to cool  turn power off  at circuit breake
32. s las   reas expuestas del    calentador si las paredes se pintar  n o se les dar   textura     INACIO  Instale la rejilla    Fije la rejilla con los tornillos suministrados  Deslice la perilla del termostato  en el eje del control derecho extendi  ndola por la rejilla  y la perilla del tempo   rizador en el eje izquierdo  Conecte la alimentaci  n en el panel de desconex     i  n principal     P  gina 10              REJILLA  v     ex   _ L OREJETA          Figura 9       OPERACION DEL CALENTADOR      A ADVERTENCIA Riesgo de electrocuci  n e  incendio    El calentador debe instalarse correctamente  antes de usarlo    1  No lo opere sin la rejilla    2  Mantenga los cables el  ctricos  cortinas  mue   bles  y dem  s materiales combustibles a por lo  menos 3 pies por delante y a 6 pulgadas de los  costados del calentador    3  No manipule el control limitador de sobretem   peratura    4  Si los limitadores de sobretemperatura se di   syuntan m  s de una vez al d  a  se debe reempla   zar el calentador     5  Limpie el calentador por lo menos cada seis  meses    6  Despu  s de dejar que el calentador se enfr  e   desconecte la electricidad en el panel de cortacir   cuitos antes de retirar la rejilla    7  Use una secadora o aspiradora en el ciclo de  soplado para quitar la suciedad en el elemento  superior  sin tocarlo     8  Instale la rejilla antes de conectar la energ  a   A ADVERTENCIA  Toda otra labor no detallada  en esta Gu  a para el propietario la debe efectuar  un repr
33. t of heater    11  AWARNING   Risk of Fire  This heater is hot when in use   Caution   High Temperature  Risk of Fire  Keep  electrical cords  drapery  furnishings  and other  combustibles at least 3 feet from the front of the  heater and 6 inches above and on both sides     PLACEMENT  Install the Com Pak Bathroom Heater  Model CB  vertically  Heater is not approved for horizontal or ceiling mount appli     cations     THERMOSTAT  A built in thermostat and 60 minute timer   Note  Cannot be used with a wall thermostat      How do   install for new construction     SIA  Mount The Wall Can   REQUIRED MINIMUM distance of 6 inches from adjacent  surfaces and 4  inches from the floor  See Figure 4   However   Cadet recommends 12 inches from adjacent surfaces and floor  for longer and cleaner performance  Heaters must be spaced at  least 3 feet apart     Secure the wall can to the stud with 2 screws  not included   through holes provided in the wall can  As an option  the rubber  shim provided may be attached to the side of the wall can to  square the wall can to the stud  See Figures 1 and 2      Figure 1 Figure 2          Face of wall    a can must  yor oF WALL CAN   extend 7   EA inch or      inch from  face of stud    RUBBER  ToP view SH         TOP OF WALL CAN                to allow for SHEETROCK         thickness of  sheetrock     Attach wall can to stud with  screws  not included   through  holes provided in wall can        Sa Route Supply Wires   Route supply wire from the 
34. tador    3  Retire la obstrucci  n y oprima el bot  n de reglaje manual del calentador  vea las instrucciones  en la secci  n    OPERACI  N DEL CALENTADOR        4  Reemplace el conjunto del calentador           P  gina 12      2015 Cadet Impreso en EEUU Rev 06 15  720050    
35. trol limit   ador de temperatura con reglaje manual  el cual  est   dise  ado para abrir el circuito del calentador  y detener el flujo de corriente el  ctrica cuando  se detectan temperaturas de funcionamiento  excesivas  El problema debe evaluarse y el  l  mite debe restablecerse para que el calentador  vuelva a funcionar                    C  mo restablecer el control de l  mite de reglaje manual    C  mo restablecer el control limitador de temperatura de reglaje manual    Si el control limitador de reglaje manual ha abierto el circuito del calentador debido a temperatu   ras de funcionamiento excesivas  el calentador no funcionar   sino hasta que se oprima el bot  n    de l  mite de reglaje manual     Despu  s de dejar que la unidad se enfr  e durante al menos 10 minutos y resolver el problema de  que causa que se disyunte el interruptor de l  mite  generalmente el calentador est   bloqueado o  necesita limpieza   utilice un objeto puntiagudo como un bol  grafo para acceder al bot  n de reg   laje a trav  s de la secci  n central superior izquierda de la rejilla del calentador  Oprima el bot  n  FIRMEMENTE y aseg  rese de escuchar y sentir un chasquido indicando que se ha restablecido                    Reglaje     Manual e e oo          Garant  a         Para lograr una operaci  n m  s eficaz y segura y prolongar la vida   til del  calentador  lea la Gu  a del propietario y siga las instrucciones de manten   imiento  Si no le da el mantenimiento adecuado al calentador in
36. ueva el conector AMARILLO  del terminal B al terminal C     500 375   Corte el alambre con el conector AZUL en el  terminal C  Cubra el extremo del alambre suelto  con cinta para uso el  ctrico     Fijado de f  brica en 1300 vatios  NO DESENCHUFE EL CONECTOR AMARILLO DEL TERMINAL  A     VATIAJE QUE DESEA                Figura 5  Contin  e con el PASO 3                    Figura 7 Multi Voltaje   Modelo CB103 shown     Figura 8 Vatiaje M  ltiple   Modelo CB132 shown       C  mo se coloca la unidad del calentador en la c  mara de pared     wales  Instale la unidad del calentador    Voltee la unidad del calentador  dejando el elemento abajo con el motor hacia arriba   Empalme los alambres de suministro con los  del calentador mediante conectores de alambres  no incluidos    Consulte las Figuras 7 y 8   Ahora gire el calentador de modo que el  elemento y el ventilador queden hacia arriba  El elemento debe quedar arriba     Inserte el borde inferior del conjunto del calentador en las ranuras semicirculares del reborde inferior en la c  mara de pared  Consulte  la Figura 9    IMPORTANTE  Presione los cables hasta el fondo de la c  mara de pared durante la inserci  n  Cerci  rese de que los  cables de suministro no queden atrapados entre el motor y la c  mara de pared   Conecte el conjunto en la parte superior con el tornillo    que se proporciona     Nota  La garant  a pierde su validez si se roc  a alg  n producto en el elemento  o en el soplador  Cubra con cinta para pintura toda
37. utos   Nota  No se puede usar con un termostato mural        C  mo se instala el calentador en paredes de  construcciones nuevas     ASTON  Montaje de la c  mara de pared    La distancia MINIMA REQUERIDA es de 6 pulgadas desde las  superficies adyacentes y 4  pulgadas desde el piso  Consulte la  Figura 4   Sin embargo  Cadet recomienda 12 pulgadas desde las  superficies adyacentes y el piso para lograr un rendimiento m  s  prolongado y limpio  Si Se instalan varios calentadores  deje al  menos tres pies entre ellos     Fije la c  mara de pared al puntal con 2 tornillos  no incluidos    mediante los orificios que vienen en la c  mara  Como alternativa   se puede a  adir la cu  a de caucho suministrada al costado de la  c  mara para cuadrarla con el puntal  Consulte las Figuras 1 y 2      Figura 1    Figura 2       La cara de VISTA SUPERIOR Gaurd y   la camara de   Lo  pared debe   MES  sobresalir  entre   y   de      PA DELA  CAMARA DE PARED               PARTE SUPERIOR DE LA    pulgada de la      CAMARA DE PARED  PA L  MINA DE YESO   cara del puntal       r J Conecte la camara de  a fin de dejar pared al puntal mediante  espacio para la los tornillos  no incluidos    lamina de yeso           NSO Instalaci  n de los cables de suministro    Dirija el cable de suministro desde   el cortacircuito GFCI a la c  mara   de pared  Quite un destapadero y   fije el cable de suministro mediante  un conector de alivio de tensi  n  no  incluidos  dejando 6 pulgadas de  cable de conexi  n  
38. validar    la garant  a y puede hacer que el aparato funcione incorrectamente  Las  garant  as no son transferibles y rigen s  lo para el comprador original  Los  t  rminos de la garant  a se indican a continuaci  n     GARANT  A LIMITADA DE TRES A  OS  Cadet reparar   o reemplazar    todo calentador Com Pak Bath  CB  que se determine est   averiado en  un plazo de tres a  os a partir de la fecha de compra     Estas garant  as no son pertinentes para   1  Da  os que sufra el producto por instalaci  n o voltaje de suministro  incorrectos   2  Da  os que sufra el producto por mantenimiento incorrecto  uso indebi   do  abuso  accidente o alteraciones   3  Servicio que se le haya dado al producto por parte de personas o  entidades ajenas a Cadet   4  Casos en que no se pueda determinar la fecha de fabricaci  n del   roducto      Casos en que el producto resulte da  ado durante el embarque por  causas ajenas a Cadet   6  El uso de accesorios o componentes no autorizados constituye una  alteraci  n e invalida las garant  as  Consulte el sitio web de Cadet o bien  llame al servicio al cliente al 855 CADET US para ver una lista de los  accesorios y componentes autorizados     7  LAGARANTIA DE CADET SE LIMITAA LA REPARACION O RE   EMPLAZO  TAL COMO SE ESTABLECE EN ESTE DOCUMENTO   CADET NO SE HARA RESPONSABLE POR DANOS ALA PROPIEDAD  O DANOS CONSECUENTES  COMO TAMPOCO POR GASTOS AC   CIDENTALES DEBIDO AL INCUMPLIMIENTO DE ESTAS GARANTIAS  ESCRITAS O DE CUALQUIER GARANTIA EXPRESA O IMP
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
ST-SD20 User`s Guide  Time Series Analysis Tools User Manual  取扱説明書  Terra 800 User Manual  Samsung RT30GKSW User Manual    INMOS TN24 - Exploring multiple transputer arrays  A114.001 - Bartscher  Garmin GPSMAP 4000 User's Manual  Table of Contents    Copyright © All rights reserved. 