Home

Cadet CS102T Installation Guide

image

Contents

1. thickness of sheetrock Attach wall can to stud with screws Model CS shown Sl Route Supply Wires Route supply wire from the circuit breaker to the thermostat to the wall can For models with a built in thermostat route supply wire from the circuit breaker to the wall can Remove a knockout from the wall can and attach the supply wire with a strain relief connector not included leaving a minimum of 6 inches wire lead for later use Connect supply ground wire to grounding screw in wall can See Figure 3 Proceed to PART TWO How do l install in an existing wall SAA Cut A Hole In The Wall REQUIRED MINIMUM distance of 6 inches from adjacent surfac es and 4 1 2 inches from the floor See Figures 4 amp 5 However Cadet RECOMMENDS 12 inches from adjacent surfaces and floor for longer and cleaner performance Heaters must be spaced at least 3 feet apart Model CS Cut a hole 8 inches wide by 10 1 4 inches high next to a wall stud Model CST Cut a hole 14 5 8 inches wide by 10 1 4 inches high next to a wall stud SY Route Supply Wires Route supply wire from the circuit breaker to the thermostat to the wall can For models with an in built thermostat route supply wire from the circuit breaker to the wall can Remove a knockout from the wall can and attach the supply wire with a strain relief con nector not included leaving a minimum of 6 inches wire lead for later use Con nect supply ground wire
2. 6 CADET S WARRANTY IS LIMITED TO REPAIR OR RE PLACEMENT AS SET OUT HEREIN CADET SHALL NOT BE LIABLE FOR DAMAGES SUCH AS PROPERTY DAMAGE OR FOR CONSEQUENTIAL DAMAGES AND OR INCIDENTAL EX PENSES RESULTING FROM BREACH OF THESE WRITTEN WARRANTIES OR ANY EXPRESS OR IMPLIED WARRANTY 7 IN THE EVENT CADET ELECTS TO REPLACE ANY PART OF YOUR CADET PRODUCT THE REPLACEMENT PARTS ARE SUBJECT TO THE SAME WARRANTIES AS THE PROD UCT THE INSTALLATION OF REPLACEMENT PARTS DOES NOT MODIFY OR EXTEND THE UNDERLYING WARRANTIES REPLACEMENT OR REPAIR OF ANY CADET PRODUCT OR PART DOES NOT CREATE ANY NEW WARRANTIES 8 These warranties give you specific legal rights and you may also have other rights which vary from state to state Cadet nei ther assumes nor authorizes anyone to assume for it any other obligation or liability in connection with its products other than as set out herein If you believe your Cadet product is defective please contact Cadet Manufacturing Co at 360 693 2505 during the warranty period for instructions on how to have the repair or replacement processed Warranty claims made after the warranty period has expired will be denied Products returned without authorization will be refused Parts and Service Visit cadetheat com parts service for information on where to obtain parts and service Reduce Reuse Recycle This product is made primarily of recyclable materials You can reduce your carbon footprint by recycling
3. No lo use a la intemperie 6 Para desconectarlo ponga los controles en OFF y apague la alimentaci n del circuito del calentador en el panel de desconexi n principal 7 AADVERTENCIA 4 Riesgo de electrocuci n No introduzca ni permita que ingresen objetos en las aberturas de la ventilaci n o escape ya que ello puede causar electrocuci n o incendio o bien da ar el calentador 8 ADVERTENCIA Riesgo de incendio Para evitar posibles incendios no bloquee las tomas de aire ni el escape de manera alguna 9 ADVERTENCIA Podr an producirse explosiones o incendios Todo calentador contiene piezas que se calientan y pueden producir arcos voltaicos o chispas No lo use en reas donde se utilice o almacene gasolina pintura o vapores o l quidos inflamables 10 Use este calentador s lo como se describe en este manual Todo otro uso no recomendado por el fabricante puede causar incendios descargas el ctricas o lesiones personales 11 El calentador debe instalarse correctamente antes de usarlo 12 A ADVERTENCIA A Riesgo de electrocuci n e incendio No lo opere sin la rejilla 13 Conserve estas instrucciones Diagramas de cableado CON TERMOSTATO MURAL DE UN SOLO POLO ALTERNATIVO A 77 Hacialdesde Y el calentador a Modelo CS REGLAJE MANUAL LIMITADOR N y ELECTRICO DE ALTA TEMPERATURA Na L2 Y m e Calentador Aislado de Desconexi n ALTERNATE CON TERMOSTATO MURAL DE DOS POLOS
4. 1000 8 3 CS151 CS151T 1500 12 5 CS058 CS058T 500 2 4 CS078 CS078T 750 3 6 CS108 CS108T 1000 4 8 on CS118 CS118T 1100 5 3 CS158 CS158T 1500 7 2 CS208 CS208T 2000 9 6 CS052 CS052T 500 2 1 CS072 CS072T 750 3 1 sate C 102 CS102T 1000 4 2 CS122 CS122T 1250 5 2 CS152 CS152T 1500 6 3 CS202 CS202T 2000 8 3 Com Pak Twin Models voltage Thermostat Thermostat 1 Watts Amps CST308 CST308T 3000 14 4 one CST408 CST408T 4000 19 2 CST102 CST102T 1000 4 2 CST152 CST152T 1500 6 3 240 2 CST202 CST202T 2000 8 3 CST302 CST302T 3000 12 5 CST402 CST402T 4000 16 7 1 Standard built in thermostat is single pole and has no OFF position 2 240 volt models can be used at 208 volts Wattage equals 75 of 240v rated wattage Com Pakand Das Com Pak Twin feed ER LEA Models Without o oo o Thermostat LN N N Wall Thermostat O Pi Y a O Required V4 OS OS UL O EJ o Om 7 LISTED Com Pakand 2 3 Com Pak Twin A cad ada Models With o E oa o Thermostat N UN ZSJ Wall Thermostat Not O Pi YU D Required qQ O04 OVS Ade LOD o _ oo Rating Label Built in Thermostat SAVE THESE INSTRUCTIONS cadetheat com Tel 360 693 2505 PO Box 1675 Vancouver WA 98668 1675 Page 1 IMPORTANT INSTRUCTIONS A WARNING When using electrical appliances basic precautions shoul
5. ALTERNATIVO ee eee no Fusible de sobretemperatura e e 1 Hacia desde s Y el calentador y Calentador con termostato incorporado Modelo CST REGLAJE MANUAL LIMITADOR ELECTRICO DE ALTA TEMPERATURA REGLAJE MANUAL LIMITADOR EL CTRICO DE ALTA TEMPERATURA 1 Calentador Aislado de Desconexi n ida l Calentador Aislado de Desconexi n Calentador con E termostato incorporado En E L2 a a Consulte las inserciones para cableado de calentadores sin termostato incorporado CONSERVE ESTAS INSTRUCCIONES cadetheat com Tel 360 693 2505 PO Box 1675 Vancouver WA 98668 1675 P gina 8 INSTRUCCIONES PARA LA INSTALACION 1 ADVERTENCIA Verifique que todos los cables de suministro el c trico sean del mismo voltaje que el calentador 2 Si va a reemplazar un calentador existente re vise la etiqueta del calentador antiguo 3 Todo trabajo y materiales el ctricos deben cumplir con el C digo El ctrico Nacional NEC por su sigla en ingl s con la Ley de Seguridad y Salud Ocupacional OSHA por su sigla en in l s y con todos los c digos estatales y locales Si se debe instalar un nuevo circuito o se necesita informaci n adicional sobre el cableado consulte a un electricista calificado 5 Use conductores de cobre solamente 6 A ADVERTENCIA A Riesgo de electrocuci n NO instale el calenta dor directamente sobre la tina o lavamanos NO lo instale en la z
6. de pared apuntando hacia arriba TERMOSTATO Se requiere un termostato mural para los modelos que no lo traigan incorporado Se recomienda usar un termostato electr nico Cadet para una comodidad y un control ptimos C mo se instala el calentador en paredes de construcciones nuevas Nsom Montaje de la c mara de pared La distancia MINIMA REQUERIDA es de 6 pulgadas desde las superficies adyacentes y 4 1 2 pulgadas desde el piso consulte las figuras 4 y 5 Sin embargo Cadet RECOMIENDA 12 pul gadas desde las superficies adyacentes y el piso para lograr un rendimiento m s prolongado y limpio Si se instalan varios calen tadores deje al menos tres pies entre ellos Revise la etiqueta de la c mara de pared para determinar la direcci n correcta tal como lo indican las flechas ascendentes N antes de montar la c mara en el puntal En la posici n de mon ale VERTICAL el elemento del conjunto del calentador que da en la parte SUPERIOR En la posici n de montaje HORIZON TAL queda a la IZQUIERDA Modelo CS Manteniendo la parte delantera de la c mara a ras con la superficie mural acabada consulte la figura 1 fije la c mara de pared al puntal con 2 tornillos no se inclu en mediante los orificios que vienen en la c mara Se puede a adir la cu a de caucho suministrada al costado de la c mara para cuadrarla con el puntal consulte la figura 2 Modelo CST Manteniendo la parte delantera de la c mara a ras con la superficie
7. this product at the end of its useful life Contact your local recycling support center for further recycling instructions Page 5 MAINTAINING YOUR HEATER Maintenance As Needed or every six months minimum A WARNING Before removing grill turn the electrical power off at the electrical panel board circuit breaker or fuse box Lock or tag the panel board door to prevent someone from accidentally turning the power on while you are working on the heater Failure to do so could result in serious electrical shock burns or possible death NWARNING Any other service not detailed in this Owner s Guide should be performed by an autho rized service representative 1 It is important that you verify power has been turned off and no power is going to the heater before proceeding Circuit breakers are often not marked correctly and turning the wrong breaker off could mean electricity is flowing to the heater even if the heater does not appear to be working If you are uncomfortable working with electrical appliances unable to follow these guidelines or do not have the necessary equipment consult a qualified electrician 2 Once you verify the power has been turned off correctly pro 4 Wash grill with hot soapy water and dry immediately 5 While holding fan to avoid damage or bending use a hair dryer or vacuum on blow cycle to blow debris through the top element do not touch element 6 V
8. too low 2 Heater has tripped the power reset high temperature control 3 Heater has tripped the second ary over temperature fuse 4 Power not on at the circuit breaker 5 Broken or poorly connected wire s to heater 6 Defective thermostat olution 1 Verify that supply voltage matches the heater rating 2 The total amperage of all heaters on a branch circuit must not be more than 80 of the amperage rating of the circuit breaker and supply wire ratings Use a lower wattage heater or reduce the number of heaters on the circuit 3 Shorted supply or heater wires may be accompanied by severe sparking Inspect all supply and heater wiring insulation for damage Do not reset the circuit breaker until all electrical shorts have been repaired 4 Replace the circuit breaker 1 Allow a few moments for element to reach operating temperature 2 Verify that supply voltage matches the heater rating 3 Replace element 4 CST models have two heating units with independent over temperature controls One of the high temperature manual power reset controls may trip and cut power to one of the heating units while the other remains running resulting in only half output Reset the heater unit see Operating section for Resetting the Manual Power Reset Limit Control 1 Close doors and windows Provide additional insulation or install a higher wattage heater or multiple heaters if necessary If your circuit is rated
9. 27 C mara de pared inferior 36 83 1016 ae Com Pak Twin Al 2 22 HERRAMIENTAS NECESARIAS e Cuchillo multiuso e Destornillador Phillips e 4 tornillos de 17 para madera e Destornillador plano e Conectores de alambre aislados e Pelacables e 1 conector de alivio de tensi n Com Pak Modelos eg Modelo sin Modelo con Vatios Amps inea Termostato Termostato 1 CS051 CS051T 500 4 2 120 Cs101 CS101T 1000 8 3 CS151 CS151T 1500 12 5 CS058 CS058T 500 2 4 CS078 CS078T 750 3 6 CS108 CS108T 1000 4 8 en CS118 CS118T 1100 5 3 CS158 CS158T 1500 7 2 CS208 CS208T 2000 9 6 CS052 CS052T 500 2 1 CS072 CS072T 750 3 1 240 2 CS102 CS102T 1000 4 2 CS122 CS122T 1250 5 2 CS152 CS152T 1500 6 3 CS202 CS202T 2000 8 3 Com Pak Twin Modelos poe Modelo sin Modelo con Vatios Amps inea Termostato Termostato 1 CST308 CST308T 3000 14 4 cl CST408 CST408T 4000 19 2 CST102 CST102T 1000 4 2 CST152 CST152T 1500 6 3 240 2 CST202 CST202T 2000 8 3 CST302 CST302T 3000 12 5 CST402 CST402T 4000 16 7 1 Termostato estandar incorporado de un solo polo y sin posici n de apagado 2 Los modelos de 240 voltios pueden usarse a 208 voltios El vatiaje es igual al 75 de la potencia nominal de 240 v Modelos p Com Pak Twin E o sin termostato AS Requieren Pi Y UL termostato mural OCS oo LISTED o Modelos Com p
10. CADETS Benefits You Can Depend On e DUAL SAFETY FEATURES Primary power reset thermal switch Secondary over temperature thermal fuse e Heating element style quickly warms your room and quickly cools when heater is not in use Common sense components designed with you in mind 1 NO sharp edges 2 Corrosion resistant 3 Easy to install heater one screw 4 Easy to install wall can Your Cadet heater has been thoroughly tested and is guaranteed with a 2 year extended warranty Side Grill Front Wall Can Side 12 30 48 o E lt g 2 54 22 86 Wall Can Bottom Te ___ 20 00 E i ds 10116 Com Pak o ofl 1 14 la as 3 18 Side Grill Front ese 12 1118 30 48 28 26 25 4 Wall Can Side 16 2 54 41 27 Wall Can Bottom 14 36 83 4 3 10 16 ze Com Pak Twin 7 2 22 TOOLS REQUIRED Phillips Screwdriver e Straight Screwdriver e Wire Strippers e Utility Knife e 4 1 1 2 Wood Screws e Insulated Wire Connectors e 1 Strain Relief Connector Com Pak Heater Owner s Guide http www cadetheat com products wall heaters com pak Com Pak Models Mel free heroes 1 Watts Amps CS051 CS051T 500 4 2 120 CS101 CS101T
11. S Pak Twin con o ES termostato ZX No requieren 0 lt 7 termostato mural Etiqueta calificaci n a Termostafo incorporado is Q LN ES e eo no Ss P gina 7 INSTRUCCIONES IMPORTANTES MADVERTENCIA Al utilizar artefactos el ctricos siempre se deben adoptar precauciones b sicas para reducir el riesgo de incendios electrocuci n y lesiones personales incluyendo lo siguiente 1 Lea todas las instrucciones antes de instalar o usar este calentador 2 A ADVERTENCIA Riesgo de incendio Este calentador se calienta mucho cuando est en uso Precauci n Alta temperatura Riesgo de incendio Mantenga los cables el ctricos cortinas muebles y dem s materiales combustibles a por lo menos 3 pies por delante y a 6 pulgadas por encima y por ambos costados del calentador 3 A ADVERTENCIA Riesgo de quemaduras Para evitar quemaduras no lo toque con su piel descubierta Tenga mucho cuidado cuando alg n tipo de calentador sea usado por o cerca de ni os o de personas inv lidas y cada vez que lo deje funcionando sin vigilancia 4 A ADVERTENCIA A Riesgo de electrocuci n No opere ning n calentador despu s de una aver a Desconecte la alimentaci n en el panel de servicio y pida a un t cnico electricista calificado que lo revise antes de volver a usarlo 5 4 ADVERTENCIA
12. The heater should come back on An additional 20 minute waiting period is required every time the power is turned off Restoring power even briefly will heat the limit even though the heater does not come on 6 The heater is now functional and the thermostat can be reset to your comfort level Note that resetting the manual power reset control may not restore heater operation if a severe over temperature condition has occurred See the Troubleshooting Guide on next page for more information Warrant For more effective and safer operation and to prolong the life of the heater read the Owner s Guide and follow the maintenance instructions Failure to properly maintain the heater will void any warranty and may cause the heater to function improperly War ranties are non transferable and apply to original consumer only Warranty terms are set out below LIMITED TWO YEAR WARRANTY Cadet will repair or replace any Com Pak CS Com Pak Twin CST heater found to be detective within two years after the date of purchase These warranties do not apply 1 Damage occurs to the product through improper installation or incorrect supply voae 2 Damage occurs to the product through improper maintenance misuse abuse accident or alteration 3 The product is serviced by anyone other than Cadet 4 If ne date of manufacture of the product cannot be deter mined ir the product is damaged during shipping through no fault of adet
13. acuum fan area without touching the elements 7 Do not lubricate motor 8 Replace grill and secure with screws Replace thermostat knob ceed to the next step 3 Remove thermostat knob if any screws and take off grill ymptom Problem Breaker trips 1 Incorrect supply voltage immediately 2 Overloaded circuit upon energiz ing heater 3 A short circuit exists in the supply or heater wiring 4 Defective circuit breaker Heater fan 1 Insufficient element temperature operates 2 Incorrect supply voltage but does not 3 Element has failed discharge 4 Model CST only One of the warm alr heater units over temperature con trols must be reset Heater will 1 Heat loss from room is greater not shut off than heater capacity capacity 2 Defective thermostat 3 Thermostat wired incorrectly to heater Heater 1 Dust lint or other matter has discharges accumulated inside heater smoke or 2 Poor or loose electrical connec emits a burnt odor stops heating Heater does not run Troubleshooting Chart CONSULT LOCAL ELECTRICAL CODES TO DETERMINE WHAT WORK MUST BE PERFORMED BY QUALIFIED 9 Turn thermostat to desired setting 10 Turn power back on at the electrical panel board ELECTRICAL SERVICE PERSONNEL tions Element 1 Defective motor or internal heats for a connection moment with 2 Fan or motor jammed out the fan turning then immediately 1 Thermostat set
14. all can See Figure 9 Important Push wires into bottom of wall can during insertion Be sure that supply wires are not caught between motor and wall can Attach heater assembly at top with screw provided Suaa Install Grill Secure grill with the screws provided If you have a built in thermo stat model slide thermostat knob onto shaft Turn power on at the electrical panel board Warranty is void if any material is sprayed on the element or blower GRILL Use a paint mask to cover any exposed areas of the heater if walls are to be textured or painted Figure 8 Figure 9 Page 4 OPERATING INSTRUCTIONS ANWARNING Risk of Electrical Shock and Fire The heater must be properly installed before it is used 1 Do not operate without grill 2 Keep electrical cords drapery furnishings and other combustibles at least 3 feet away from the front of the heater and 6 inches away from the sides 3 Do not tamper with the over temperature limit control 4 If the heater over temperature limits trip more than once per day the heater must be replaced 5 Clean heater at least every six months 6 After allowing the heater to cool turn power off at circuit breaker panel before removing grill 7 Use a hair dryer or vacuum on blow cycle to blow debris through the top element do not touch element 8 Install the grill before turning on power A WARNING Any other service not detailed in this Ow
15. calentador no reciba energ a Los cortacircuitos no suelen estar correctamente mar cados y apagar el incorrecto podr a significar que sigue fluyendo electricidad al calentador aun cuando ste parezca no estar 4 Lave la rejilla con agua caliente y jab n y s quela de inmedi ato 5 Mientras sujeta el ventilador para evitar que se da e o tuer za utilice una secadora o una aspiradora en el ciclo de soplado para quitar la suciedad en el elemento superior sin tocarlo funcionando Si no se siente c modo al trabajar con artefactos el ctricos no est en condiciones de acatar estas pautas o no cuenta con los equipos necesarios solicite los servicios de un t cnico electricista calificado 2 Una vez que verifique que se ha apagado la alimentaci n correctamente prosiga con el paso siguiente 3 Retire la perilla del termostato si la hubiera los tornillos y extraiga la rejilla 6 Aspire el rea del ventilador sin tocar los elementos 7 No lubrique el motor 8 Vuelva a instalar la rejilla y fijela con los tornillos Vuelva a colocar la perilla del termostato 9 Coloque el termostato en la graduaci n deseada 10 Vuelva a conectar la alimentaci n en el tablero del panel el ctrico Tabla de resoluci n de problemas CONSULTE LOS C DIGOS EL CTRICOS LOCALES PARA DETERMINAR QU TRABAJOS DEBEN SER REALIZADOS POR PERSONAL DE SERVICIO ELECTRICO CALIFICADO intoma El interruptor se disyunta inmedia
16. d always be followed to reduce the risk of fire electric shock and injury to persons including the following 1 Read all instructions before installing or using this heater 2 A WARNING Risk of Fire This heater is hot when in use Caution High Temperature Risk of Fire Keep electrical cords drapery furnishings and other combustibles at least 3 feet from the front of the heater and 6 inches above and on both sides 3 A WARNING Burn Hazard To avoid burns do not let bare skin touch hot surfaces Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended 4 AWARNING A Risk of Electrical Shock Do not operate any heater after it malfunctions Disconnect power at service panel and have heater inspected by a qualified electrician before reusing 5 A WARNING Do not use outdoors 6 To disconnect heater turn controls to off and turn off power to heater circuit at main disconnect panel 7 AWARNING A Risk of Electrical Shock Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater 8 AWARNING Risk of Fire To prevent a possible fire do not block air intakes or exhaust in any manner 9 WARNING Fire or explosion may occur A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable
17. ebajo de la temperatura ambiente 2 Deje que la unidad se enfr e durante al menos 20 minutos 3 Resuelva el problema que causa la disyunci n del limitador general mente el calentador est bloqueado o necesita limpieza consulte las instrucciones de mantenimiento 4 Aumente la temperatura en el termostato por sobre la temperatura ambiente El calentador debiera encenderse Si no vuelve a encenderse restablezca el calentador en el cortacircuito usando las instrucciones siguientes Se requiere esperar un per odo adicional de 20 minutos cada vez que se apaga la alimentaci n Restaurar la alimentaci n incluso brevemente calentar el interruptor de l mite aunque el calentador no se encienda 5 En este instante el calentador funciona correctamente y el termostato puede volver a fijarse en un nivel c modo Para reestablecer el calentador en el cortacircuito se recomienda si la temperatura ambiente es inferior a 45 1 Coloque el cortacircuito en la posici n de apagado 2 Deje que la unidad se enfr e durante al menos 20 minutos 3 Resuelva el problema que causa la disyunci n del limitador general mente el calentador est bloqueado o necesita limpieza consulte las instrucciones de mantenimiento 4 Reestablezca la alimentaci n colocando el cortacircuito en la posici n de encendido 5 Aumente la temperatura en el termostato por sobre la temperatura ambiente El calentador debiera encenderse Se requiere esperar un
18. ed for models without a built in thermostat A Cadet electronic thermostat is recommended for ultimate control and comfort How do l install for new construction SAA Mount The Wall Can REQUIRED MINIMUM distance of 6 inches from adjacent surfac es and 4 1 2 inches from the floor See Figures 4 8 5 How ever Cadet RECOMMENDS 12 inches from adjacent surfaces and floor for longer and cleaner performance Heaters must be spaced at least 3 feet apart Review the wall can label for correct direction as noted by the UP arrows before mounting the wall can to the stud In the VERTI CAL mounting position the element of the heater assembly will be at the TOP In the HORIZONTAL mounting position the element of the heater assembly will be to the LEFT Model CS Keeping front of the wall can flush with the finished wall surface See Figure 1 secure the wall can to the stud with 2 screws not included through holes provided in the wall can The rubber shim provided may be attached to the side of the wall can to square the wall can to the stud See Figure 2 Model CST Keeping front of the wall can flush with the finished wall surface See Figure 1 secure the wall can to both wall studs with 4 screws not included through holes provided in the wall can Figure 1 Figure 2 RUBBER TOP view SH fj CCC Face of wall can must yop oF WALL CAN extend 1 2 Vee inch or 5 8 inch from face of stud to allow for TOP OF WALL CAN
19. educir la temperatura del ambiente gire la perilla en sentido contrario a las manecillas del reloj G rela en sentido de las manecillas del reloj para aumentarla Acerca de los controles limitadores de la temperatura del calentador El calentador est protegido por dos controles limitadores de tempera tura para el modelo CST se usan cuatro controles Ambos controles son parte integral del conjunto del elemento El primero es un control limitador de reglaje el ctrico manual dise ado para abrir el circuito del calentador cuando se detectan temperaturas de funcionamiento excesiv as El problema debe evaluarse y el l mite debe reestablecerse para que el calentador vuelva a funcionar Se brinda protecci n adicional mediante un fusible secundario de so bretemperatura el cual abrir el circuito del calentador en condiciones graves de sobretemperatura o bien en caso de falla de alg n componen te Si ello ocurre el calentador se debe reparar o reemplazar C mo restablecer el control de l mite de reglaje el ctrico manual Si el control limitador de reglaje el ctrico manual ha abierto el circuito del calentador debido a temperaturas de funcionamiento excesivas el calentador no funcionar sino hasta que se haya restablecido Ello puede hacerse en el termostato o en el cortacircuito que controla el calentador Para reestablecer el calentador en el termostato 1 Reduzca la temperatura en el termostato por d
20. ermostat are not recommended REQUIRED MINIMUM distance of 6 inches from adjacent surfaces See Figure 6 However Cadet RECOMMENDS 12 inches from adjacent surfaces for longer and cleaner performance Secure the wall can to studs rafters on opposite sides See Fig ures 6 and 7 with 4 screws not provided The face of the wall Figure 6 can must extend 1 2 or 5 8 inch from face of rafters to allow for Model CS shown thickness of sheetrock SU Route Supply Wires Important Supply connections must use wires suitable for at least 167 F 75 C Route supply wire from the circuit breaker to the thermostat to the wall can Remove a knockout from the wall can and attach the supply wire with a strain relief connector not included leaving a minimum of 6 inches wire lead for later use Connect supply ground wire to grounding screw in wall can See Figure 3 Pro Figure 7 ceed to PART TWO Model CS shown Partio SUPPLY How do l insert the heater assembly into the wall can WIRES Su Install Heater Assembly CONNECTOR Turn the heater face down element facing down and the motor facing you Connect the supply wires to the heater wires with wire HEATER WIRES connectors not included See Figure 8 Rotate the heater up so that the element and fan are facing you with the fan below the ele GROUNDING ment Insert the bottom edge of the heater assembly into the tabs in the bottom lip of the w
21. ficies adyacentes y el piso para lograr un rendimiento m s prolongado y limpio Si se instalan varios calen tadores deje al menos tres pies entre ellos Modelo CS Corte un orificio de 8 pulgadas de ancho por 10 Y de alto al lado del puntal de la pared Modelo CST Corte un orificio de 14 5 8 pulgadas de ancho por 10 de alto al lado del puntal de la pared ARTO Instalaci n de los cables de suministro Dirija el cable de suministro desde el cortacircuito al termostato y a la c mara de pared Para los modelos con termo stato incorporado dirija el alambre de suministro desde el cortacircuito hasta la c mara de pared Quite uno de los destapaderos de la c mara y coloque el cable de suministro mediante un conec tor de alivio de tensi n m se incluye dejando un m nimo de 6 pulgadas de cable de conexi n para utilizarlo m s adelante Conecte el cable de suminis tro a tierra al tornillo de puesta a tierra situado en la c mara de pared consulte la figura 3 NO Montaje de la c mara de pared Revise la etiqueta de la c mara de pared para determinar la direcci n correcta tal como lo indican las flechas ascendentes UP antes de montar la c mara en el puntal En la posici n de montaje VERTICAL el elemento del conjunto del calentador gueda en la parte SUPERIOR En la posici n de montaje HORI ONTAL queda a la IZQUIERDA Coloque la c mara d pared en la abertura Modelo CS Manteniendo la parte delantera de la c mara a
22. for more 2 Adjust thermostat to its lowest setting If heater continues to run allow two minutes for the thermostat to respond and room temperature is greater than 50 replace the thermostat 3 Refer to thermostat documentation and correct wiring 1 Clean heater see Maintenance section above for instructions 2 Turn off power at circuit breaker Inspect all supply and heater wire connec tions to make sure nothing is loose or poorly connected Secure or reconnect all loose connections Do not reset circuit breaker until all connections have been checked and repaired 1 Heater or fan motor requires replacement 2 Remove obstruction and follow instructions in the Operating section for Resetting the Manual Power Reset Limit Control Test heater operation If heater does not run heater requires repair or replacement 1 Adjust thermostat to a higher temperature until heater operates see Problem 6 if the problem persists 2 Follow instructions in the Operating section for Resetting the Manual Pow er Reset Limit Control If room temperature is below 45 see Reset Heater at the Circuit Breaker instructions 3 Asevere over temperature condition has occurred Repair or replace heater 4 Turn on the correct circuit breaker in the main panel 5 Turn off power at circuit breaker Check supply wire continuity and proper connection to heater wires 6 The entire heater or any of its com
23. it or need addi tional wiring information consult a qualified elec trician 5 Use copper conductors only 6 A WARNING A Risk of Electrical Shock DO NOT install the heat er directly above bathtub or sink DO NOT install in shower stall area Manufacturer recommends a minimum 2 foot clearance 7 Heater must be installed in a wall can Model CS Wall Can CC Model CST Wall Can WC1 Part One 8 MWARNING Risk of Fire DO NOT install the heater in a floor in the ceiling below a towel bar behind a door or anywhere the air discharge may be blocked in any manner 9 AWARNING Fire or Explosion May Occur A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable va pors or liquids are used or stored 10 A WARNING A Risk of Electrical Shock Connect grounding lead to grounding screw provided Keep all foreign ob jects out of heater 11 AWARNING Risk of Fire This heater is hot when in use Caution High Temperature Risk of Fire Keep electrical cords drapery furnishings and other combustibles at least 3 feet from the front of the heater and 6 inches above and on both sides PLACEMENT Install the Com Pak model CS vertically recommended horizontally or in the ceiling For ceiling mounting refer to instructions on page 4 The Com Pak Twin Model CST must be installed with the arrows in the wall can pointing upwards THERMOSTAT A wall thermostat is requir
24. l 360 693 2505 para obtener instrucciones sobre c mo tramitar la reparaci n o el reemplazo del producto Los reclamos de garant a pre sentados despu s de la finalizaci n del per odo no ser n acogidos Los productos que se devuelvan sin autorizaci n ser n rechazados Repuestos y Servicio En cadetheat com parts service encontrar informaci n sobre d nde obtener repuestos y servicio Reduzca Reutilice Recicle Este producto est hecho principalmente de materiales reciclables Puede reducir la cantidad de carbono que contribuye al medio ambi ente reciclando este producto al t rmino de su vida til Comun quese con su centro local de reciclaje para obtener mayores instrucciones al respecto P gina 11 MANTENIMIENTO DEL CALENTADOR Mantenimiento Seg n sea necesario o cada seis meses como m nimo APAGADO ADVERTENCIA Desconecte la electricidad en el tablero del panel el ctrico caja de cortacircuitos o fusibles y trabe o coloque un cartel en la puerta del tablero del panel para evitar que alguien vuelva a conectar la energ a mientras se est trabajando en el calentador De lo contrario podr an producirse graves golpes el ctricos quemaduras e incluso la muerte ADVERTENCIA Toda otra labor no detallada en esta Gu a para el propietario la debe efectuar un representante de servicio autorizado 1 ntes de proceder es importante que usted verifique que se haya desconectado la alimentaci n y que el
25. l Calentador para restablecer el control limitador de reglaje el ctrico manual Si la temperatura ambiente es inferior a 45 consulte las instrucciones Para reestablecer el calentador en el cortacircuito 3 Se ha producido una situaci n de sobretemperatura grave Repare o reemplace el calentador 4 Conecte el cortacircuito correcto en el panel principal 5 Desconecte la energ a en el cortacircuito Revise la continuidad del cable de suministro y la conexi n apropiada a los cables del calentador 6 Se debe revisar la continuidad de todo el calentador o bien de sus componentes a fin de deter minar la causa de los problemas Repare o reemplace el calentador o termostato P gina 12 2014 Cadet Impreso en EEUU Rev07 14 730021
26. lemento 4 Los modelos CST tienen dos unidades calentadoras con controles de sobretemperatura independientes Uno de los controles el ctricos de alta temperatura manuales puede disyuntarse e interrumpir la alimentaci n a una de las unidades calentadoras mientras el otro permanezca funcionando reduciendo el rendimiento a la mitad Restablezca la unidad calentadora siga las instrucciones de la secci n Operaci n del Calentador para restablecer el control limitador de reglaje el ctrico manual El calentador no se apaga 1 La fuga de calor de la habitaci n es superior a la capacidad del calenta dor 2 Termostato defectuoso 3 Termostato cableado al calentador de forma incorrecta 1 Cierre las puertas y ventanas Coloque aislamiento adicional o instale un calentador de mayor vatiaje o m ltiples calentadores si fuera necesario Si su circuito tiene mayor capacidad 2 Ajuste el termostato a la graduaci n m s baja Si el calentador contin a funcionando espere un par de minutos para que el termostato tenga tiempo de responder al ajuste y la temperatura del ambiente es superior a 50 grados reemplace el termostato 3 Consulte la documentaci n del termostato y cableado correcto El calentador emite humo o un olor a quemado 1 Se han acumulado polvo pelusas u otros materiales dentro del calentador 2 Conexiones el ctricas deficientes o sueltas 1 Limpie el calentador consulte las instrucciones e
27. mural acabada consulte la figura 1 fije la c mara de pared a los puntales con 4 tornillos no se incluyen mediante los orificios que vienen en la c mara Figura 1 Figura 2 La cara de VISTA SUPERIOR CAUCHO ap la camara de Lo A EPARED pared debe so MES PARTE SUPERIOR DELA CAMARA bresalir entre 2 y 5 8 de pulgada de la cara del st puntal a fin de Conecte la camara de dejar espacio pared al puntal mediante para la lamina los tornillos Aparece el de yeso modelo CS JOY Instalaci n de los cables de suministro Dirija el cable de suministro desde el cortacircuito al termostato y a la c mara de pared Para los modelos con termostato incorpo rado dirija el alambre de suministro desde el cortacircuito hasta la c mara de pared Quite uno de los destapaderos de la c mara y coloque el cable de suministro mediante un conector de alivio de tensi n no se incluye dejando un m nimo de 6 pulgadas de cable de conexi n para utilizarlo m s adelante Conecte el cable de suministro a tierra al tornillo de puesta a tierra situado en la rola de pared consulte la figura 3 Contin e con la PARTE C mo se instala el calentador en una pared existente ASTON Corte un orificio en la pared La distancia MINIMA REQUERIDA es de 6 pulgadas desde las superficies adyacentes y 4 1 2 pulgadas desde el piso consulte las figuras 4 y 5 Sin embargo Cadet RECOMIENDA 12 pul gadas desde las super
28. n la secci n Mantenimiento del Calentador 2 Desconecte la energ a en el cortacircuito Inspeccione todas las conexiones de alambres del suministro y del calentador para cerciorarse de que no haya nada suelto ni mal conectado Afiance o reconecte todas las conexiones sueltas No restablezca el cortacircuito sino hasta haber revisado y reparado todas las conexiones El elemento cali enta por un mo mento sin que gire el ventilador y luego deja de calentar 1 Motor o conexi n interna defectu osos 2 Ventilador o motor trabado 1 Debe reemplazarse el calentador o el motor del ventilador 2 Retire la obstrucci n y siga las instrucciones en la secci n Operaci n del Calentador para restablecer el control limitador de reglaje el ctrico manual Pruebe el funcionamiento del calenta dor Si no funciona rep relo o reempl celo El calentador no funciona 1 El termostato se ha graduado muy bajo 2 El calentador ha disyuntado el con trol el ctrico de alta temperatura 3 El calentador ha disyuntado el fus ible secundario de sobretemperatura 4 La energ a no est conectada en el cortacircuito 5 El o los cables que van al calenta dor est n rotos o mal conectados 6 Termostato defectuoso 1 Ajuste el termostato a una temperatura m s alta hasta que el calentador funcione vea el Proble ma No 6 si el problema persiste 2 Siga las instrucciones en la secci n Operaci n de
29. ner s Guide should be performed by an authorized service representative How to operate your heater The room temperature is controlled by a line voltage thermostat located either on the wall or at the lower left on the heater See Page 1 In built Thermostat 1 Once installation is complete and power has been restored turn the thermostat knob fully clockwise 2 When the room reaches your comfort level turn the thermo stat knob counterclockwise until the heater turns off The heater will automatically cycle around this preset temperature 3 To reduce the room temperature turn the knob counterclock wise To increase the room temperature turn the knob clockwise Over Temperature Limiting Controls If normal operating temperatures are exceeded due to abnormal circumstances the heater has two temperature limiting controls for Model CST four controls are used Both limiting controls are located on the element assembly The first is a manual power reset limit control designed to open the heater circuit when ex cessive operating temperatures are detected The problem must be assessed and the limit must be reset to resume operation Further protection is provided by a secondary over temperature fuse which will open the heater circuit in severe over tem perature conditions or in the event of component failure If this occurs the heater must be repaired or replaced Resetting the Manual Power Reset Limit Co
30. ntrol If the manual power reset limit has opened the heater circuit due to excessive operating temperatures the heater will not work until it is reset This can be done at the thermostat or the circuit breaker controlling the heater To Reset Heater at the Thermostat 1 Lower the temperature on the thermostat below room tempera ture 2 Allow the unit to cool for at least 20 minutes 3 Resolve the problem causing the limit to trip typically the heat er is blocked or needs cleaning see Maintenance Instructions 4 Raise the temperature on the thermostat back above room temperature The heater should come back on If it does not come back on reset heater at the circuit breaker using directions below An additional 20 minute waiting period is required every time the power is turned off Restoring power even briefly will heat the limit even though the heater does not come on 5 The heater is now functional and the thermostat can be reset to your comfort level To Reset Heater at the Circuit Breaker recommended if room temperature is below 45 1 Trip the breaker by switching it to the OFF position 2 Allow the unit to cool for at least 20 minutes 3 Resolve the problem causing the limit to trip typically the heat er is blocked or needs cleaning see Maintenance Instructions 4 Restore power to the heater by switching the breaker to the ON position 5 Raise the temperature on the thermostat above room tempera ture
31. ona de la ducha el fabricante recomienda un espacio m nimo de 2 pies 7 El calentador debe instalarse en una c mara de pared Modelo CS C mara de Pared CC Modelo CST C mara de Pared WC1 Parte Uno 8 A ADVERTENCIA Riesgo de incendio NO instale el calentador en el piso en el cielo raso bajo la barra de la toalla detr s de una puerta ni en ning n otro lugar en el que la descarga de aire se pueda bloquear de alguna manera 9 ADVERTENCIA Podr an producirse explosiones o incendios Todo calentador contiene piezas que se calientan y pueden producir arcos voltaicos o chispas No o use en areas donde se utilice o almacene gas one pintura o vapores o l quidos inflamables 10 M ADVERTENCIA A Riesgo de electrocuci n Conecte el conductor a tierra al tornillo de puesta a tierra suministrado Evite que entren objetos extra os al calentador 11 M ADVERTENCIA Riesgo de incendio Este calentador se calienta mucho cuando est en uso Precauci n Alta temperatura Riesgo de incendio Mantenga los cables el ctricos cortinas muebles em s materiales combustibles a por lo menos 3 pies por delante y a 6 pulgadas por encima y por ambos costados del calentador UBICACI N Instale la unidad Com Pak modelo CS verticalmente recomendado horizontalmente o en el cielo raso Consulte las instrucciones de la p gina 10 para el montaje en cielo raso La unidad Com Pak Twin modelo CST se debe instalar con las flechas en la c mara
32. per odo adicional de 20 minutos cada vez que se apaga la alimentaci n Restaurar la alimentaci n incluso brevemente calentar el interruptor de l mite aunque el calentador no se encienda 6 En este instante el calentador funciona correctamente y el termostato puede volver a fijarse en un nivel c modo Tenga en cuenta que restablecer el control de reglaje el ctrico manual puede no ser suficiente para restaurar la operaci n del calentador en caso de que se haya producido una situaci n de sobretemperatura grave Consulte la Gu a de resoluci n de problemas en la pr xima p gina para obtener m s informaci n al respecto Garant a Para lograr una operaci n m s eficaz y segura y prolongar la vida til del calentador lea la Gu a del propietario y siga las instrucciones de manten imiento Si no le da el mantenimiento adecuado al calentador invalidar la garant a y puede hacer que el aparato funcione incorrectamente Las garant as no son transferibles y rigen s lo para el comprador original Los t rminos de la garant a se indican a continuaci n GARANT A LIMITADA DE DOS A OS Cadet reparar o reemplazar todo calentador Com Pak CS o Com Pak Twin CST que se determine est averiado en un plazo de dos a os a partir de la fecha de compra Estas garant as no son pertinentes para 1 Da os que sufra el producto por instalaci n o voltaje de suministro incorrectos 2 Da os que sufra el producto por mantenimien
33. ponents may be checked for continuity to T the cause of any problems Repair or replace the heater or thermo stat Page 6 2014 Cadet Printedin USA Rev 07 14 730021 CADETS El Calentador Com Pak Guia Para el Propietario http Awww cadetheat com products wall heaters com pak Beneficios En Las Que Puede Confiar e CARACTER STICAS DE DOBLE SEGURIDAD Primaria interruptor t rmico con reinicio de potencia Secundaria fusible t rmico de sobretemperatura e El estilo de elemento calentador calefacciona r pid amente el ambiente y se enfr a con rapidez cuando no est en uso e Componentes con sentido com n dise ados pen sando en usted 1 SIN bordes filosos 2 Resistentes a la corrosi n 3 Calentador f cil de instalar con un solo tornillo 4 C mara de pared f cil de instalar e Su calentador Cadet ha sido completamente probado y cuenta con una garant a extendida de 2 a os Costado Rejilla Frente C mara de pared costado 12 11 87 10 30 48 28 26 25 4 3267 O Q 3 18 L o ae an g gt 2 54 22 86 Camara de pared inferior Tl gt 20 00 o 4 I fs Com Pak 10 16 al oji om ra ksl late Camara de Costado Rejilla Frente pared costado a i E i ps 12 418 10 30 48 28 26 25 4 E E l y 164 2 54 41
34. ras con la superficie mural acabada fije la c mara de pared al puntal con 2 tornillos no se incluyen mediante los orificios que vienen en la c mara Se puede a adir la cu a de caucho suministrada a on de la camara para cuadrarla con el puntal consulte la igura 2 odelo CST Manteniendo la parte delantera de la c mara a ras con la superficie mural acabada consulte la figura 1 fije la c mara de pared a los puntales con 4 tornillos no se incluyen mediante los orificios que vienen en la c mara Contin e con la PARTE DOS CABLE DEL SUMINISTRO DESTAPADERO GIRE PARA ETIRARLO sl TORNILLO DE CONECTOR DE PUESTA A TIERRA ALIVIO DE TENSI N Figura 3 P gina 9 INSTRUCCIONES PARA LA INSTALACION continuaci n Figura 4 Modelo CS PARED ADYACENTE PARED ADYACENTE Figura 5 Modelo CST C mo se instala el calentador con montaje en cielo raso ASTON Montaje de la c mara de pared Importante 1 Para modelos de hasta 1 500 vatios MAXIMO 2 No monte el calentador en cielos rasos falsos ni de fibra de baja densidad 3 No se recomienda usar modelos con termostato incorporado La distancia MINIMA REQUERIDA es de 6 pulgadas desde las superficies adyacentes consulte la figura 6 Sin embargo Cadet RECOMIENDA 12 pulgadas desde las superficies adyacentes para lograr un rendimiento m s prolongado y limpio Asegure la c mara de pared a puntales vigas en lados contrari o
35. s consulte las figuras 6 y 7 con 4 tornillos no suministrados La cara de la c mara de pared debe sobresalir entre 1 2 y 5 8 de pulgada de la cara de las vigas a fin de dejar espacio para la l mina de yeso ARTO Instalaci n de los cables de suministro Importante Las conexiones de suministro deben usar cables aptos para al menos 167 F 75 C Dirija el cable de suministro desde el cortacircuito al termostato y a la c mara de pared Quite uno de los destapaderos de la c mara y coloque el cable de suministro mediante un conector de alivio de tensi n no se incluye dejando un m nimo de 6 pulgadas de cable de conexi n para utilizarlo m s adelante Conecte el cable de suministro a tierra al tornillo de puesta a tierra situado en la c mara de pared consulte la figura 3 Contin e con la PARTE DOS Figura 6 Modelo CS shown Figura 7 Modelo CS shown Parte Dos Una vez que ha seguido todas las instrucciones en la PARTE UNO ya est preparado para instalar el conjunto del calentador C mo se coloca la unidad del calentador en la c mara de pared Instale la unidad del calentador Gire la cara del calentador de modo que d hacia el piso el elemen to debe estar orientado hacia abajo y el motor hacia usted Empalme CABLES DE SUMINISTRO CONECTOR DE ALAMBRE CONECTOR DE ALAMBRE los alambres de suministro con los del calentador mediante conec tores de alambre no se incl
36. s a por lo menos 3 pies por delante y a 6 pulgadas de los costados del calentador 3 No manipule el control limitador de sobretem peratura 4 Si los limitadores de sobretemperatura se di syuntan m s de una vez al d a se debe reempla zar el calentador 5 Limpie el calentador por lo menos cada seis meses 6 Despu s de dejar que el calentador se enfr e desconecte la electricidad en el panel de cortacir cuitos antes de retirar la rejilla 7 Use una secadora o aspiradora en el ciclo de soplado para quitar la suciedad en el elemento superior sin tocarlo 8 Instale la rejilla antes de conectar la energ a A ADVERTENCIA Toda otra labor no detallada en esta Gu a para el propietario la debe efectuar un representante de servicio autorizado C mo hacer funcionar el calentador La temperatura ambiente es controlada por un termostato de voltaje de l nea situado ya sea en la pared o en la parte inferior izquierda del calen tador consulte la p gina 1 Termostato incorporado 1 Una vez que se haya realizado la instalaci n y reestablecido la energ a el ctrica gire totalmente la perilla del termostato en el sentido de las manecillas del reloj 2 Cuando la habitaci n haya alcanzado un nivel c modo gire la perilla del termostato en sentido contrario a las manecillas del reloj hasta que el calentador se apague El calentador se encender y apagar autom ticamente seg n esta temperatura preestablecida 3 Para r
37. tamente al encenderse el Problema 1 Voltaje de suministro incorrecto 2 Circuito sobrecargado olucion 1 Compruebe que el voltaje de suministro coincida con la calificaci n del calentador 2 El amperaje total de todos los calentadores en un circuito de rama no debe sobrepasar el 80 de la calificaci n de amperaje del cortacircuito y de las calificaciones de los cables de suministro Utilice un calentador de vatiaje inferior o reduzca la cantidad de calentadores en el circuito del calentador funciona pero no env a aire caliente calentador 3 Hay un cortocircuito en los cables 3 Los cables de suministro o del calentador que presentan cortocircuitos pueden ocasionar de suministro o del calentador chispas peligrosas Revise el aislamiento de todos los cables de suministro y del calentador para comprobar que no est n da ados No reestablezca el cortacircuito sino hasta que se hayan repa rado todos los cortocircuitos el ctricos 4 Cortacircuito defectuoso 4 Reemplace el cortacircuito El ventilador 1 Temperatura insuficiente del 1 Espere unos momentos para que el elemento alcance la temperatura de funcionamiento elemento 2 Voltaje de suministro incorrecto 3 El elemento ha fallado 4 Modelo CST solamente Se debe reestablecer uno de los controles de sobretemperatura de las unidades calentadoras 2 Compruebe que el voltaje de suministro coincida con la calificaci n del calentador 3 Reemplace el e
38. to grounding screw in wall can See Figure 3 123 Mount The Wall Can Review the wall can label for correct direction as noted by the UP arrows before mounting the wall can to the stud In the VERTI CAL mounting position the element of the heater assembly will be at the TOP In the HORIZONTAL mounting position the element of the heater assembly will be to the LEFT Insert wall can into wall opening Model CS Keeping front of the wall can flush with the finished wall surface secure the wall can to the stud with 2 screws not included through holes provided in the wall can The rubber shim provided may be attached to the side of the wall can to square the wall can to the stud See Figure 2 Model CST Keeping front of the wall can flush with the finished wall surface See Figure 1 secure the wall can to both wall studs with 4 screws not included through holes provided in the wall can Proceed to PART TWO SUPPLY WIRE KNOCK OUT TWIST TO REMOVE STRAIN RELIEF CONNECTOR Figure 3 Page 3 INSTALLATION INSTRUCTIONS continued eS Part One E Figure 4 Model CS ADJACENT WALL ADJACENT WALL Figure 5 Model CST How do l install for a ceiling mount SUE Mount The Wall Can Important 1 For models up to 1 500 Watts MAXIMUM 2 Do not mount the heater in low density fiber board or false ceilings 3 Models with a built in th
39. to incorrecto uso indebi do abuso accidente o alteraciones 3 Servicio que se le haya dado al producto por parte de personas o entidades ajenas a Cadet 4 Casos en que no se pueda determinar la fecha de fabricaci n del producto 5 Casos en que el producto resulte da ado durante el embarque por causas ajenas a Cadet 7 6 LA GARANTIA DE CADET SE LIMITA A LA REPARACI N O RE EMPLAZO TAL COMO SE ESTABLECE EN ESTE DOCUMENTO CADET NO SE HARA RESPONSABLE POR DA OS A LA PROPIEDAD O DA OS CONSECUENTES COMO TAMPOCO POR GASTOS AC CIDENTALES DEBIDO AL INCUMPLIMIENTO DE ESTAS GARANT AS ESCRITAS O DE CUALQUIER GARANT A EXPRESA O IMPL CITA 7 EN CASO DE QUE CADET DECIDA REEMPLAZAR ALGUNA PIEZA DEL PRODUCTO CADET LOS REPUESTOS SE REGIRAN POR LAS MISMAS GARANT AS DEL PRODUCTO LA INSTALACI N O RE EMPLAZO DE LOS REPUESTOS NO MODIFICA NI PROLONGA LAS GARANT AS VIGENTES EL REEMPLAZO O REPARACI N DE TODO PRODUCTO O PIEZA CADET NO ORIGINA NINGUN TIPO DE NUEVA GARANT A 8 Estas garant as le otorgan derechos legales espec ficos y es posible que usted tenga otros derechos que var en de un estado a otro Cadet no asume ni autoriza a nadie que lo haga en su nombre ninguna otra obligaci n o responsabilidad en relaci n con sus productos que no sean las que se establecen en este documento Si durante el per odo de garant a usted considera que su producto Cadet presenta defectos comun quese con Cadet Manufacturing Co llaman do a
40. uyen consulte la figura 8 Gire el calen tador hacia arriba de modo que el elemento y el ventilador queden delante suyo con el ventilador debajo del elemento Inserte el borde inferior de la unidad del calentador en las orejetas del reborde inferi or en la c mara de pared consulte la figura 9 Importante Presione los cables hasta el fondo de la c mara de pared durante la inserci n Cerci rese de que los cables de sum inistro no queden atrapados entre el motor y la c mara de pared Conecte el conjunto del calentador en la parte superior con el tornillo que se proporciona mney Instale la rejilla Fije la rejilla con los tornillos suministrados Si tiene un modelo con termostato incorporado deslice la perilla del termostato hacia el eje Conecte la alimentaci n en el tablero del panel el ctrico La garant a pierde su validez si se roc a alg n producto en el ele mento o en el soplador Cubra con cinta para pintura todas las reas expuestas del calentador si las paredes se pintar n o se les dar textura P gina 10 Figura 8 Figura 9 CABLES DEL CALENTADOR TORNILLO DE PUESTA A TIERRA En lt MOTOR OPERACION DEL CALENTADOR Ax ADVERTENCIA Riesgo de electrocuci n e incendio El calentador debe instalarse correctamente antes de usarlo 1 No lo opere sin la rejilla 2 Mantenga los cables el ctricos cortinas mue bles y dem s materiales combustible
41. vapors or liquids are used or stored 10 Use this heater only as described in this manual Any other use not recommended by the manufacturer may cause fire electrical shock or injury to persons 11 The heater must be properly installed before it is used 12 AWARNINGA Risk of Electrical Shock and Fire Do not operate without grill 13 Save these instructions Wiring Diagram WITH SINGLE POLE WALL THERMOSTAT ALTERNATE SA S Pa s Y TolFrom Heater SN q N 1 1 1 l I l 1 cy I ri Model CS 1 MANUAL POWER RESET HIGH TEMPERATURE LIMIT SL L2 e ra SA e WITH DOUBLE POLE WALL THERMOSTAT ALTERNATE HA x e gt qe To From Heater gt 1 Heater with built in thermostat A a SS See insets for heater wiring without built in thermostat Model CST MANUAL POWE R RESET MANUAL POWER RESE HIGH TEMPERATURE LIMIT T HIGH TEMPERATURE LIMIT Heater with built in thermostat SAVE THESE INSTRUCTIONS cadetheat com Tel 360 693 2505 PO Box 1675 Vancouver WA 98668 1675 Page 2 INSTALLATION INSTRUCTIONS 1 A WARNING Verify that the electrical supply wires are the same voltage as the heater 2 If replacing an existing heater check the label of the old heater 3 All electrical work and materials must comply with the National Electric Code NEC the Occu pational Safety and Health Act OSHA and all state and local codes 4 If you need to install a new circu

Download Pdf Manuals