Home
        Blue Flame LLA.1220.NG Installation Guide
         Contents
1.  BlueF lame prooucts    FIREPLACE  amp  BARBEQUE ACCESSORIES          SPECIFICATIONS   Input Rating    20 000 Btu hr Model  LL S A  1220NG   26 000 Btu hr Model  LL S A  1626NG   40 000 Btu hr Model  LL S A  2440NG   51 000 Btu hr Model  LL S A  3051 NG   59 000 Btu hr Model  LL S A  3659NG   68 000 Btu hr Model  LL S A  4068NG   31 000 Btu hr 2  Model  LLT 7 531 NG     Normal Inlet Pressure  7    W C   1 74 kPa   Maximum Inlet Pressure  10 5    W C   2 61 kPa   Minimum Inlet Pressure  3 5    W C   0 87 kPa              WARNING  Do not restrict air flow into Fireplace using the log  lighter     Make sure the chimney flue is open before  attempting to operate this device     Make sure that glass doors are open while using  the log lighter and spark screen is closed     Failure to observe these warnings may result in  possible injury              INSTALLATION   Install  amp  use this device with care  Follow all local codes or  in the  absence of local codes  to the National Fuel Gas Code  ANSI Z 223   LINFPA 54     GAS LINE INSTALLATION  Gas controls shall not be installed inside the fireplace     e Gas controls must be properly located and shielded to prevent  overheating due to exposure to the wood fire        Piping which exits the fireplace will conduct heat  Adequate  clearances must be maintained from piping to combustible  construction to avoid a fire hazard  It is required that a minimum  1 2    clearance to combustibles be maintained within 6    of  where the gas line
2.  passes through any side of the fireplace   Pipe sealant must be used on all joints     LOG LIGHTER INSTALLATION   Log lighter should be installed on the front of the grate in such a  manner to minimize flame impingement  the amount of heat exposure  and that logs placed on the grate will not rest directly on the log  lighter tube  Also  the floor clearance should be sufficient to minimize  the chance of the blockage of the burner ports by ash accumulation     Steps to install your log lighter   1  The fireplace should be free of all debris     2  A listed Blue Flame gas valve must be installed up steam of  the log lighter     3  Run gas pipe to the log lighter  Lighter must be secured in a  rigid manner  Example  use 112    rigid pipe for gas inlet and  to the log lighter  inlet 1 2    NPT   Use pipe fittings to support  the opposite plugged end of the log lighter  1  2    male NPT   incontact with the floor or side of the fireplace  Do not use  copper or flexible connectors inside the firebox  Locate log  lighter as indicated above and maintain proper clearances     4  The log lighter should be located such that the burner ports  are facing inwards at 30 45 degrees  with the air shutter  facing out towards the front  Adjust the air shutter to give  sharp blue flames with yellow tips     5  The log lighter and its individual shutoff valve must be  disconnected from the gas supply piping system during any  pressure testing of that system at test pressures in excess of  1 2 ps
3. eplace match or a lit paper  under the center of the lighter near the burner ports     8  Tum the gas valve ON gradually until burner ignition occurs     9  If burner does not light with five seconds  tum gas valve OFF  and wait 5 minutes before trying to relight     0  When log lighter is burning  close the fireplace screens  Do  not close glass doors unless the wood in fireplace has been  certified for use with log lighter with doors closed     1  When the wood fire is lit  the log lighter valve should be  turned off  Failing to do so will cause wood to bum quicker  than normal        2  Remove gas valve key and place in a safe location out of  reach of small children     LEAK CHECKING   Periodically check all connections for leaks  or immediately check  if smell of gas is detected  Do not smoke while leak checking   Extinguish all open flames  Make a soap solution of one part liquid  detergent and one part water  You will need a spray bottle  brush or  a pieces of rag to apply the solution to the fittings     1  Light the burner by using a long fireplace match or a lit paper  under the center of the lighter near the burner ports     2  Tum the gas valve ON gradually until burner ignition occurs     3  Apply the soap solution around the connections  Soap  bubbles will appear where a leak is present     4  Ifa leak is present  immediately tum off gas valve  tighten  any leaking connection  relight the burner and recheck     MAINTENANCE INSTRUCTIONS   Dust  lint  debris and s
4. i  3 5 kPa   The log lighter must be isolated from the  gas supply piping system by closing its individual manual  shutoff valve during any pressure testing of the gas supply  piping system at test pressures equal to or less than Y  psi  3  5 kPa      LIGHTING INSTRUCTIONS  1  MAKE SURE CHIMNEY FLUE IS OPEN BEFORE ATTEMPTING TO  OPERATE THIS DEVICE     2  Fireplace should be clean of all debris  as this could  contain hot coals which could cause ignition if not removed  or disposed properly  Ashes should be placed in a metal  container with a tight fitting lid  The closed container should  not be placed on a combustible floor  and kept away from  other combustible materials until the ashes have cooled or  have been removed from the container  Before disposing of  ashes  ensure that all cinders have cooled thoroughly     3  Make sure the log lighter gas valve is in the OFF position     4  Stack logs on the fireplace grate allowing an air space  between logs for quick lighting  Wait approximately five  minutes before lighting     5  Make sure that shutter on mixing chamber is open to ensure  that air and gas is being mixed  flame should be blue     6  _ If the fireplace is equipped with glass doors  the doors shall  be opened for at least 5 minutes before attempting to light  the device  In case of burner outage  the gas supply shall  be turned off and the doors left open for at least 5 minutes  before attempting to relight the device     7  Light the burner by using a long fir
5. pider webs can build up during off season   Keep burner and air flow passageways clean  Inspect or have  these areas inspected at the beginning of the heating season by a  qualified service person     Before Cleaning  Ensure the gas valve is off  Make sure the  fireplace is cool     Burner Cleaning  Use a flashlight to inspect the log lighter  inlet  amp  burner ports to ensure they are not blocked  If obstruction  can be seen then use a metal wire coat hanger that has been  straightened out     Air Passageways  Glass Doprs  amp  Screens  Use a vacuum  cleaner to clean the combustion  circulating air passageways and  screens and dampened cloth to clean the glass doors     Fireplace Build up  Remove ash build up to avoid blockage of  burner ports        DBlueFlameprooucts    FIREPLACE  amp  BARBEQUE ACCESSORIES    Canterbury Enterprises  440 E  Harrison Street    Corona  CA 92879 e Toll Free  800 321 6566  www blueflamestore com    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Tecnostyl PFM03 picture frame  Hunter 81030 Use and Care Manual  Polycom V4.0 User's Manual  Sea Gull Lighting 31105BLE-72 Installation Guide  ダウンロード  Prime-Line Products R 7261 Instructions / Assembly  Audio-Technica Mouse ATW-RCS1 User's Manual    Agilent E4991A RF Impedance/ Material Analyzer    Copyright © All rights reserved. 