1. BLUE GROUND bare ON OFF SWITCH purchase separately SWITCH BOX WIRING PLATE MODE POWER SWITCH SWITCH 120 VAC LINE IN 3 4 Using wire nuts not provided connect house power cable to ventilating fan 3 5 14 AWG 2 1 mm is the smallest conductor that sha be used for branch circuit wiring 4 TEST RUN amp GRILLE ATTACHMENT 4 1 When the power on check for abnormal vibration or sound 4 2 Insert the mounting springs into the slots and mount the grille to the fan unit Grille _ 5 OPERATION Low speed air volume preset control Humidity preset control 5 1 Humidity control mode Turn the POWER switch on to operate at humidity control mode the LED indicator will be blue When the ambient humidity is higher than the user adjustable set point the fan will run at full speed When the ambient humidity is lower than the set point the fan will continue to run at the full speed until a 10 minute time delay has elapsed and then will automatically change to the user adjustable low speed airflow 5 2 Full speed mode Turn the MODE switch on to operate at full speed mode the LED indicator will be amber 5 3 Humidity tolerance is about 10 Long time operation will influence the detecting precision as dust accumulates The humidity switch may need to be adjusted 6 MAINTENANCE
2. A NELTA INSTALLATION AND OPERATING INSTRUCTIONS VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION k Make sure that the electric service supply voltage is AC 120V 60Hz rA Follow all local electrical and safety codes as well as the Nation Electrical Code NEC and the Occupation Safety and Healthy Act OSH Act 3 Always disconnect the power source before working on or near the ventilating fan motor or junction box 4 Protect the power cord from sharp edges oil grease hot surfaces chemicals or other objects 5 Do not kink the power cord 6 Do not install the unit where ducts are configured as shown in Fig A Te Provide suction parts with proper ventilation 8 This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit 9 These ventilating fans are intended for residential usage only WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Al Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and ele
3. WARNING Disconnect power source before working on unit Routine maintenance must be done every year CAUTION 1 Never use gasoline benzene thinner or any other such chemicals for cleaning the ventilating fan 2 Do not allow water to enter motor 3 Do not soak resin parts in water over 60 C CLEANING 1 Pull down the spring to remove grille Z Wash and clean grille Use non abrasive kitchen detergent wipe dry with new cloth 3 Using a cloth dampened with non abrasive kitchen detergent remove dust and dirt from ventilating fan Wipe dry with new cloth 4 Replace grille DIMENSIONS A E o 4 DUCT 1 10 75 d breez GreenBuilder MODEL GBR80H Page 2 SPECIFICATIONS Power Air Flow Model No ae ree 0 1SP 01SP i ii w CFM GBRB0H yg 60 97 80 58 124 H GBRBOH 44g 60 40 50 58 124 1 Note Design and specifications subject to change without notice WARRANTY DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY Delta Electronics Inc Delta Electronics warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship This warranty is limited to three 3 years from the original date of purchase Limitations and Exclusions 1 During the warranty period a replacement for any defective product will be supplied fre
4. al deterioration or degradation of products or parts thereof due to a physical environment beyond the requirements of products specifications Address 4405 Cushing Parkway Fremont CA 94538 US Toll Free Number 1 888 979 9889
5. ctrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors iE f this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit nterrupter protected branch circuit 8 Do not use this unit with any other solid state control devices Solid state control devices may cause harmonic distortion which can cause a motor humming noise 9 NEVER place a switch where it can be reached from a tub or shower 10 jot to be installed in a ceiling thermally insulated to a value greater than R40 This is required for installation in Canada only Turning angle too large Duct shrink Elbow near the body Body N Fig A CAUTION 1 For general ventilating us
6. e of charge for installation by the consumer The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting repair removal and installation service 2 All returns of defective parts or products must include the product model number and must be made through an authorized Delta Electronics distributor Authorized returns must be shipped prepaid Repaired or replacement products will be shipped by Delta Electronics F O B shipping point 3 Delta Electronics shall not be liable for any indirect incidental consequential punitive or special damages arising out of or in connection with products use or performance regardless of the form of action whether in contract tort including negligence strict product liability or otherwise 4 This warranty does not extend to fluorescent lamp starters and tubes 5 The warranty does not cover if user does not comply with manufacture s installation manual 6 To qualify for warranty service you must notify Delta Electronics at the address or telephone number below 7 Delta Electronics shall have no liability to the original owner user with respect to any defect caused by abuse misuse neglect improper transportation or storage improper testing improper installation improper operation improper use improper maintenance improper repair improper alteration improper modification tampering or accident of products or parts thereof or unusu
7. e only Do not use to exhaust hazardous or explosive materials and vapors 2 Not for use in cooking areas Fig B 3 This product must properly connect to the grounding conductor of the supply circuit 4 To reduce the risk of injury to persons install the fan at least 8 2 feet 2 5m above the floor Cooking area 4 breez GreenBuilder MODEL GBR80H Page 1 1 INSTALLATIONS S Roof cap N lt 7 with built in NY damper Short piece of flexible X duct helps alignment and absorbs sound Fan housing ee Sy eee Ww NN da J 7 DN F ee Wall cap A a with built in Seal gap Caulk termination damper around to duct housing MOUNT HOUSING WITH FLANGE 1 1 To bend the housing tabs out to 90 degree and make housing tabs contact the bottom of the joist m Do not install above or p ipida this arae a 1 2 The housing mounts with 4 screws 4x25 Screw housing to joist through lowest holes in each 2 mounting flange then through the other holes 43 W B SS Cooking Equipment _ floor s zai Joist Fig 8 go Mhe SUPPLIED ACCESSORIES a ba g A Screw 64 BB Part name Appearance Quantity l USING SUSPENSION BRACKETS SOLD SEPARATELY Grille 1 1 3 Sliding suspension brackets available to allow for your specific positioning of housing anywhere X betwe
8. en joists and span up to 24 EN 1 4 Insert suspension brackets into the channels on Fan ith m 1 housing Make sure tabs face up shown l Mii D Suspension Bracket Sold separately s Housing Tab Face Duct Channel Connector 4 e gt 1 5 Extend suspension brackets to the width of the joists Hold fan in place with the suspension brackets tabs Screw x wrapping around the bottom of joist 04x25 1 6 Fasten suspension brackets to joists with nails or screws through holes near nails 1 7 Secure suspension brackets together with screws NELTA Bottom of Joist 2 DUCT CONNECTION 2 1 Insert the duct into the duct connector and tape all ductworks connection to make them secure and air tight 2 2 Install the duct with a gradient 1 2 to the outside NSISSISSS AS SEANS TSS Inside N Outside Duct Connector Tape N Body Duct y z 1 A g ea A Ceiling x N Gradient 7 Y 402 Grille N 3 CONNECT WIRING 3 1 Follow all local electrical and safety codes ANSI NFPA70 3 2 NEVER place a switch where it can be reached from a tub or shower 3 3 Connect wires as shown in wiring diagrams JUNCTION BOX SWITCH BOX BLACK Ee on gt L WHITE POWER SWITCH b N BLUE HI WHITE MODE SWITCH s N GREEN GRD