1. INSTALLATION II BETWEEN JOIST MOUNTING Illustrations in this manual common use the image of FV 11VHL2 1 Before installation remove warning lable and the tape that is securing the adapter and the damper Fig 1 2 Insert the suspension bracket into bracket cover of adaptor side and the back of the fan body Fig 11 Select the suspension bracket according to spacing A as shown below 16 inches and 19 2 inches horizontal joist 19 2 inches vertical joist Unit inches mm Suspension bracket I E ooo NA Fan body Suspension bracket I cket 4 T KANG Suspension bracket II Fig 11 Spacing A on center joists B 16 inches 13 1 4 15 1 2 336 394 19 2 inches horizontal joists 14 3 4 16 3 4 374 425 19 2 inches vertical joists 16 1 2 18 3 4 419 476 3 Insert the fan body between joists Make sure the fan body is level and square perpendicular with the joists Fig 12 CAUTION Keep the distance C 1 2 inch 12 7 mm for the thickness of ceiling board Fan body Suspension bracket a C 4 INSTALLATION II BETWEEN JOIST MOUNTING CONTINUED 4 Secure the suspension bracket to joists by using long screws ST4 2X20 Fig 13 Fig 14 Joist 2 Long screws ST4 2X20 Fig 13 o Secure the suspension bracket to fan body by using
2. Panasonic Ventilating Fan INSTALLATION INSTRUCTIONS Model No FV 11VH2 FV 11VHL2 FV 11VH2 FV 11VHL2 READ AND SAVE THESE INSTRUCTIONS Thank you very much for having purchased our Ventilating Fan Please read these instructions carefully before attempting to install operate or service the Panasonic Ventilating Fan Failure to comply with instructions could result in personal injury and or property damage Please retain this booklet for future reference Table of Contents UNPaCKING 0 aee e Ee ea E A aE AE eE EEE EEn 2 S pplied Accessories n n a a a a aeaea Eia 2 DGSCRIPHOMN cscc2icavadondaaxccisaacnsaceacadiancasanmastinaaaswcdinassetacbearatnagsdes EE RA IE 2 Dimensions osmena aa Gal ana a Sede sete Bak wa aE EEE 3 SPC CHICATONS sasaka issn areng aa a ee ga NA ala ga lan a ank Ni magae aa Ng kaga bak ajak ak 4 General Safety Information ccccecceeceeceeceeeeeeeeeeeeseeeeeeeeeeeeeeeneeseeneeaeeneeseeaes 4 5 VVIFING DIA Gra in a a a aa A E NAN a NG a aaa a BE a E E NANA 5 Installation Joist Mounting I wesesanone sene seka awan e baNe aa daa ara aka ag Kanan aranan 6 7 Installation Between Joist Mounting eneke enea een eaaa nenen a aana nana ane 8 9 Installation Wooden Header Installation sesa senene naen aane 9 Maintenance Cleaning cccccccseecccceeeeeeeeesaeeceeeeaueeceeesaeeeseenauseeeeetaneeees 10 Maintenance Replacement of l
3. INSTALLATION I JOIST MOUNTING I Illustrations in this manual common use the image of FV 11VHL2 and mark for FV 11VHL2 only others are same for FV 11VH2 1 Before installation remove warning lable and the tape that is securing the adapter and the damper Fig 1 Warning label Fig 1 2 Insert the suspension bracket into the fan body Select the suspension bracket as shown below le A i Joists Spacing A on center Joists Insert Suspension bracket 16 inches and 19 2 inches horizontal joists Refer to Fig 2 1 19 2 inches vertical joists Refer to Fig 2 2 24 inches Refer to Fig 2 3 If spacing A on center joists is 24 inches connect suspension bracket I and II C4 mark to C4 mark as shown below 2 Screw I ST4 2X8 Suspension bracket I Suspension bracket II Suspension bracket I Fan body Suspension bracket II Fan body Suspension bracket M Fig 2 1 Suspension bracket I Fig 2 2 Suspension bracket I Fan body Suspension bracket I Joist Fan body 2 Long screws ST4 2X20 Joist ST4 2X12 Fig 4 1 3 Install the suspension bracket and the flange of fan body to joists by using long screws ST4 2X20 Fig 3 4 Install the suspension bracket to joists by using long screws ST4
4. screw I ST4 2X12 Fig 14 A oe Gu 4 a 6 Follow step 5 of installation I page 7 to complete the installation work INSTALLATION III WOODEN HEADER INSTALLATION Before installation remove warning lable and the tape that is securing the adapter and the damper Fig 1 Ceiling joist 2 Install header between ceiling joists using nails or screws 3 Install the fan body to the header thickness 1 5 inch or Ceiling joist more with long screws Reinforce the installation hard ware as needed to prevent the fan body from dropping Fig 15 Fig 16 Fig 15 4 Follow step 5 of installation I page 7 to complete the installation work Circular duct Long screw ST4 2X20 Fig 16 MAINTENANCE I CLEANING WARNING Disconnect power source before working on unit Routine maintenance must be done every year CAUTION 1 Never use petrol benzene thinner or any other such chemicals for cleaning the ventilating fan 2 Do not allow any water to get into the motor 3 Do not soak resin parts in water over 60 C 140 F 1 Remove grille Squeeze mounting spring and pull down carefully Fig 17 2 Wash and clean grille Use non abrasive kitchen detergent wipe dry with new cloth Fig 18 3 Remove dust and dirt from fan body using a vacuum cleaner Fig 19 4 Using a cloth dampened with kitchen detergent remove any dirt fr
5. 2X20 and secure it to the fan body by using screw I ST4 2X12 16 inches and 19 2 inches horizontal joists refer to Fig 4 1 19 2 inches vertical joists and 24 inches refer to Fig 4 2 Screw I ST4 2X12 2 Long screws ST4 2X20 INSTALLATION I JOIST MOUNTING I CONTINUED 5 Remove the lighting cord out from hook FV 11VHL2 Lighting cord Screw driver then remove junction box plate and secure conduit or stress relief to wiring box knock out hole Fig 5 6 Refer to wiring diagram Page 5 Follow all the local electrical safety codes As well as the National Electrical Code NEC Using UL approved wire nuts connect house power wires to ventilating fan wires Fig 6 Black to black white to white green to green i Make sure all connections are fastened firmly after Black to black X Write to white wiring is finished a Green to green Replace the junction box plate and then replace Wire nut lighting cord to hook Fig 5 Black to black Black to black CAUTION Mount junction box plate carefully so that lead wires White to white AST 7 bok are not pinched i yp D Gondut Fig 6 WARNING 1 Disconnect power source before working on unit Conduit Circular duct 2 The lamp s glass is fragile Please handle with care To remove flourescent lamp grasp at base and move back and forth to loosen
6. Do not pull hard on the lamp or you may break the glass 3 For heater AWG 14 or more must be used when wiring 11 9A 4 When making wiring connections take care to pre vent excessive slack in the wiring since a large of current is drawn through the heater electrical wire 5 Connect the switch to the live black color side Duct tape or clamps 4 Long screws 814 2X20 Fig 7 17 3 8 441 7 Install the circular duct 4 inches to the adaptor and secure it with duct tape or clamps Fig 7 Night lamp y 8 Finish ceiling work Ceiling hole should be aligned inches mm ape lamp Fig 8 with the edge of the flange Fig 8 Mounting spring 9 Install the fluorescent lamps and then install the C night lamp Fig 8 W IS 10 Insert mounting springs into slots as shown and Incorrect mount grille to fan body Fig 9 Note Do not mount grille and springs conversely If Grille Fig 9 the grille is mounted in the opposite direction Switch ER the grille can not be fitted to the ceiling so labels labels then reverse the grille position and try to ay mount again UU Optional Attach the given switch labels in accessories on the wall U switch not included as shown in the diagram for clearer Night Light indication Fig 10 Fig 10 For Model FV 11VHL2 For Model FV 11VH2
7. where air temperature may exceed 40 C 104 F 2 Make sure that the electric service supply voltage is AC 120V 60Hz o Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupation Safety and Health Act OSHA Always disconnect the power source before working on or near the fan motor light fixture or junction box Protect the power cord from sharp edges oil grease hot surfaces chemicals or other objects Do not kink the power cord Do not install the unit where ducts are configured as shown in Fig A Make sure that all duct work is properly vented DO NOT INSTALL THIS UNIT OVER A BATHTUB OR SHOWER ENCLOSURE This product FV 11VHL2 has a fluorescent lamp that contains mercury Disposal may be regulated in your community due to environmental considerations For disposal or recycling information please contact your local authorities or the Electronics Industries Alliance http www eiae org 87 OV O O Prohibition Prohibition Prohibition Prohibition Adaptor CMO OND A Fig A Cooking area Only for FV 11 VHL2 lt Do not install above or p N inside this area 7 N PA ae Fs CAUTION g ye 1 For general ventilating use only Do not use to exhaust 4 rs 7 N N 7 hazardous or explosive materials and vapors 2 Not for use in cooking area Fig B parani Floor 3 This product must be properly grounded equipment ra Fig B GENERA
8. L SAFETY INFORMATION CONTINUED WARNING To reduce the risk of fire electric shock or injury to persons observe the following A Use this unit only in the manner intended by the manufacturer If you have any questions please contact the manufacturer B Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Neither unauthorized modification repair nor disassembly is allowed C Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel buming equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities D When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities E Ducted fans must always be vented to the outdoors F Solid state controls may cause harmonic distortion which can cause motor humming noise To reduce the risk of fire or electric shock do not use this unit with any solid state control device G Before servicing or cleaning unit switch power off at service panel and lock panel cabinet to prevent power from being switched on accidentally If the panel cabinet cannot be locke
9. amp 0c ccc cececceceeceeeeeeeeeeceseeeeeeeeesnees 11 Practical Guide to Installation sus saik aisi E aa a a aa a Ka wa aa wakane gaga rana BN a aa iT back cover Product SERVICE sara nasa nain ang aaa a Na anja NA GG aa a Ga KING AA Waaa Ga me NG balan pa Ke aukats back cover UNPACKING Unpack and carefully remove unit from carton Refer to the Supplied Accessories list to verify that all parts are present SUPPLIED ACCESSORIES FV 11VH2 FV 11VHL2 Part name Appearance Quantity Part name Appearance Quantity Screw I ST4 2X12 FV 11VH2 Grille Long screw ST4 2X 20 FV 11VHL2 18W Suspension NY Fluorescent bracket I lamp 4W Suspension Night lamp bracket I FOR MODEL FV t1VH2 Suspension Heat _ bracket Il Tight Night Light FoR MODEL FV 11VH2 Switch labels POURLEMODELE PH Chaleur Screw I Ventilation Lumiere ST4 2X8 Lumiere de nuit POURLE MOD LE FHL Parts only for FV 11VHL2 DESCRIPTION The Panasonic ceiling mount ventilating fans uses a sirocco fan driven by a capacitor motor The motor is designed to have an extended service life with reduced energy consumption It also incorporates a thermal cut off for safety The grille covering the main body is a spring loaded quick release type A damper for preventing counterflow is provided The blower us
10. d securely fasten a clearly visible warning label to the service panel H Never place a switch where it can be reached from a tub or shower Not to be installed in a ceiling thermally insulated to a value greater than R40 This is required for installation in Canada only J Use only on 20 ampere branch circuit WIRING DIAGRAM FV 11VH2 FV 11VHL2 Circulating fan unit Circulating fan unit Lighting unit Fuse Thermal cut off Fuse Thermal cut off Fi Black f Black 20A _ 230 F 110 C Black Black 208 20 F 110 C Fluorescent lamp Red Red N fegi ET Tag res be AA fie ayah JA Thermostat Mt 140 F 60C m4 140 F 60 C ecient White ectronic White ballast Ventilating fan unit Ventilating fan unit x Red amp White Capacitor a Black Junction bo E s 8 2 E Night lamp X a 2 z m l aS S alla e Green i 1 Junction box aa Dlan FP FF 86 24 t Ww ee Osa I as se Z2 2 fic iz seo ss es Es Es i 8 5 5 6 523 55 6 5 5 553 5 4 5 553 g Os 55 TO C85 la 1088S t VVoVvyY SE yy yy 8 yyy 58 Earth ground Power Supply Power Supply Power Supply Earth ground a PANET SUPR Pea A AC120V 60Hz AC120V 60Hz AC120V 60Hz
11. es a high capacity sirocco fan developed to reduce the noise level The heater for this unit is a 1400 W sheathed heater A thermostatand thermal cut off switch have been added for safety in case of an abnormal temperature rise in the heater The lighting unit is an energy saving lighting device which uses two 18 W fluorescent lamps and produces almost the same illumination as a standard 100 W incandescent lamp FV 11VHL2 DIMENSIONS FV 11VH2 Q FV 11VHL2 19 1 2 497 16 407 CO NG ama 18 1 8 460 7 3 4 196 ite foe a 7 5 8 195 19 1 2 497 c 16 407 c a Vag 2 j n ow S a 18 1 8 460 to foo eo S 8 7 5 8 195 5 128 7 No Parama no Partrame Heating unit Lighting unit Junctionbos S Unit inches mm SPECIFICATIONS Power consumption W Speed rpm Air deliver Noise Weight Model No Air direction V Hz Fluorescent Tan WO vea Heat Vent lamp Night lamp Heat Vent etm sone lb kg 15 6 FV TIVH2 Exhaust amp 650 0 6 7 1 Circulation 120 60 1425 29 5 1540 110 TT FV 11VHL2 36 4 720 0 7 8 1 Specifications of Vent are based on HVI standard GENERAL SAFETY INFORMATION 1 Do not install this ventilating fan
12. ixtures or some competitors fan light combinations Our efficient cool running In attic installation motors and our fluorescent lamps do not caulk box to dwa A create enough ambient heat to be subjected to these limitations Short piece of flexible duct helps alignment and absorbs Insulation sound Use clamps plus tape at all flex joints Foil tape tightly covers all metal duct joints glue PVC joints Fig 23 PRODUCT SERVICE Warning Concerning Removal of Covers The unit should be serviced by qualified technicians only No service information is provided for customers Your product is designed and manufactured to ensure a minimum of maintenance However should your unit ever require service a nationwide system of factory service centers and AUTHORIZED INDEPENDENT SERVICE CENTERS is maintained to support your product s warranty In the U S A call 1 866 292 7292 to Customer call Center PANASONIC CONSUMER ELECTRONICS COMPANY Division de Panasonic Corporation of North America One Panasonic Way Secaucus NJ 07094 www panasonic com PANASONIC CANADA INC 5770 Ambler Drive Mississauga ON L4W 213 www panasonic ca X0308 0 11VH24200
13. om fan body Wipe dry with new cloth Fig 20 5 Replace grille 10 MAINTENANCE II REPLACEMENT OF LAMP WARNING 1 Disconnect power source before working on unit 2 4W night lamp has threaded base Remove by turning counter clockwise 3 The lamp s glass is fragile Please handle with care To remove lamp grasp at base and move back and force to loosen Do not pull hard on the lamp or you may break the glass 4 Be sure to remove the night lamp before removing fluorescent lamps 1 Remove grille Squeeze mounting spring and pull down Fig 17 of page 10 2 Remove the 4 W night lamp Fig 21 3 Change the fluorescent lamps FDS18E35 4 18 W Fig 22 or the 4 W night lamp Fig 21 replace the grille 11 Night lamp Fluorescent lamp Fig 21 Fluorescent lamp Fig 22 PRACTICAL GUIDE TO INSTALLATION Properly insulate the area around the fan to minimize building heat loss and gain Fig 23 Loose fill or batt insulation can be placed Dryer hood type vent with A directly over the fan housing in the attic backdraft flap s SN Panasonic fans and fan light combination units do not create excessive heat that is Caulkr rmination to duct a common problem with recessed light 2 3 ft straight run before elbow f
Download Pdf Manuals
Related Search
Related Contents
Manual de Instrucciones SmaFinger - Giga Tms Inc Samsung 275T User Manual Mai 1975 Etoile (avec section enfants - Ami Digital high Definition satellite Receiver sRT 7003 Samsung SM-G901F Priručnik za korisnike Your body copy goes here… don`t forget your chapter Manual del usuario del Suunto D6 Warranty Eyeglasses with a heart rate monitor Copyright © All rights reserved.