Home
Ventamatic CX1000AMWGUPS Instructions / Assembly
Contents
1. CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 This is an automatically operated device and is intended for use with fan facing unoccupied space only 3 This unit has an unguarded impeller Do not use in locations readily accessible to people or animals 4 Mount with the lowest moving parts at least 2 5 meters above floor or grade level VENTAMATIC LTD P 0 BOX 728 MINERAL WELLS TX 76068 0728 PHONE 800 433 1626 FAX 940 325 9311 WWW BVC COM E MAIL BVC BVC COM Aleader in the ventilation industry for over 60 years Ventamatic Ltd offers a complete line of air movement za W f A products for commercial industrial agricultural and residential use sold under these fine names Ven famatic ee le nuye t ROOF MOUNTED POWER VENTS INSTALLATION INSTRUCTIONS REV 04 09 2009 VENTAMATIC LTD INSTALLATION INSTRUCTIONS THIS ROOF MOUNTED UNIT IS DESIGNED FOR ATTICS OF AVERAGE SIZE AND OPERATES MOST EFFICIENTLY WHEN AIR INTAKES ARE LOCATED AROUND THE EAVES FOR LARGER ATTICS USE TWO OR MORE UNITS AT LEAST 600 SQ IN OF NET FREE AIR INTAKE IS REQUIRED PER UNIT THE MOTOR OPERATES ON 115 V A C 60HZ CURRENT SEE MOTOR LABEL FOR AMPERAGE STEP 1 Place unit on top of shingles bearing in mind that for neat installation the low profile housing on the unit should be visible on only one side of the roof This will require that the unit be moved slightly down from t
2. INSTALLATION INSTRUCTIONS ROOF MOUNTED POWER VENTS MODELS VXNRG VXSVR VXVIP VX2414 VX1000 CX3000 CX4000 CX2001 CX1000 FOR RESIDENTIAL USE ONLY PLEASE READ AND SAVE WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Do not attempt to use this fan with any solid state speed control device 2 Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer 3 Before servicing or cleaning this unit switch the power off at the service panel and lock out to prevent power from being switched on accidentally When service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 4 Sufficient air is needed for proper combustion and exhausting of gasses through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and local code authorities 5 Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction 6 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities
3. he ridgeline STEP 2 When this position is established locate a centerline directly between two rafters and from inside the roof drill a hole through the roof This hole will be used as a center for the following opera tions STEP 3 Draw a reference square 25 3 8 x 25 3 8 on the roof using the hole drilled in Step 2 as the center Within the square draw a 17 diameter circle and remove shingles nails and felt from the circle just drawn Next draw another circle that is 14 1 2 in diameter on the decking Be sure to use the hole drilled in Step 2 as the center of this circle For your convenience you may also use the template printed on the product packaging Cut through the decking using the 14 1 2 circle as the cut line STEP 4 Slide the flange of the unit up under the shingles some roofing nails may need to be removed Position the unit on the reference square drawn in Step 1 to align the exhaust openings When the unit is properly located apply a generous amount of roofing compound between the flange and the shingles do not hot mop approximately 1 inside the perimeter of the flange and begin to secure with nails Use galvanized roofing nails and follow the nailing pattern in the diagram provided WARNING When installing control box screw unit in place to prevent damage to the thermostat Wire the unit according to the diagram provided Be certain to conform to all electrical codes and regulations The thermostat is an adju
4. nst defects in materials and or workmanship is listed by model number VXNRG CX3000 Limited Lifetime VXSVR CX4000 Limited 5 Year VXVIP CX2001 Limited 2 Year VX2414 Limited 2 Year VX1000 CX1000 Limited 2 Year There is no warranty for defects caused by abuse In the event of a defect or malfunction we will replace the defective part or component only and return the new part to you freight prepaid You must bear all other expenses incurred in obtaining repairs including labor required for field repair or replacement and the cost of shipping the defective part to us You must also bear the cost of replacement of any part or component and the shipping charges incurred for the replacement and return to you of any part or component not covered by this warranty including parts or components damaged by you The company reserves the right to demand and receive written evidence of the date of purchase or of professional installation before undertaking to perform its obligations under this warranty You should therefore retain your sales slip and attach a copy of it to the warranty claim In order to obtain the repair or replacement of this unit you must select one of the following methods A RETURN TO FACTORY Return postage prepaid the fan or only part of the fan that you believe to be defective to the following address Ventamatic Ltd 100 Washington Street Mineral Wells TX 76067 Complete and enclose a written claim and attach a copy of
5. stable on off control When the dial is set the fan will shut off at the setting chosen The fan will start at 15 F above the setting chosen EXAMPLE If the setting is 90 F the fan will turn on when the attic temperature reaches 105 F and will turn off at 90 F STEP 5 Check the installation for leakage with water from a garden hose Do not spray water directly into the vent opening INSTALLATION DIAGRAMS DIAGRAM 1 LOCATION OF VENTILATOR Fora low profile installation ensure that the ventilator is visible on only one side of the roof by positioning the ventilator slightly below the ridgeline DIAGRAM 2 NAILING PATTERN After positioning the flange under the shingles apply a generous amount of roofing compound between the shingles and the flange approximately 1 inside the perimeter of the flange Secure the flange with galvanized roofing nails using the nailing pattern at right DIAGRAM 3 CONNECTING POWER SUPPLY AND MOTOR WIRING otto scale GROUND SCREW attach ground from Power Supply to grounding screw inside thermostat POWER SUPPLY 115V 60HZ TO MOTOR BLACK BLACK FLEXIBLE CONDUIT SERVES AS GROUND FOR THE MOTOR LIMITED WARRANTY Ventamatic Ltd extends this warranty to the original occupying owner of the home where the product is installed No subsequent purchaser of the product or of the home in which it is installed is entitled to the benefits of the warranty The warranty period agai
6. your proof of purchase or installation B RETURN TO RETAIL DEALER If the retail dealer from whom you purchased this unit stocks replacement parts or components you may return the unit which you believe to be defective to that dealer for replacement Caution Only a limited number of our retail dealers stock replacement parts If your dealer does not you must return the part to the factory following the procedure described in paragraph A above There is no informal dispute settling mechanism available in the event of a controversy involving this warranty Any and all implied warranties which may exist terminate upon the expiration of this warranty Some states do not allow limitations on how long an implied warranty lasts so this limitation may not apply to you Ventamatic Ltd is not liable to you for incidental or consequential damages arising out of a defect or malfunction of a unit or its installation or out of any alleged breach of this warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which may vary from state to state Ver ntamatic Ltd N AIR OF EXCELLENCE