1. Ap MO GA CLEAN MIST ULTRASONIC HUMIDIFIER Instruction Manual and Warranty Information nova fonr IMOO36A READ AND SAVE THESE INSTRUCTIONS Contents Safety MSU UIC ONS E 1 Unpacking Specifications ioccncinaotcatcasdowiadindauiadhoiucoanivisinutradousdantcuntentoiaunbinetiwradccdadcocounes 2 Eege Tr iea Eege 3 Filling The Water Tank Wm 4 Operating INSILUCTIONS e egngegeegegeteeeten g eegente een 5 Weekly Cleaning amp Care Storage nennen nnn nnn nnn nnns 6 Eijeble aqosujsMe e 7 otliei cilc ab DIOC IS ebore ett scooters emer eer lesi n aaa nr tatcm d 8 e e 9 SAFETY INSTRUCTIONS Prior to using the appliance read through the instructions for complete use and keep in a safe place for later reference WARNING DO NOT use outdoors Only use as intended and described in this manual DO NOT expose or immerse the Base in water or other liquids Before using the appliance extend the cord and inspect for any signs of damage DO NOT use if cord has been damaged Keep cord away from heated surfaces and out of the way where it cannot be stepped on or tripped over This appliance has a polarized plug one blade is wider than the other as a safety feature If the plug does not fit fully into the outlet reverse the plug If it still doesn t fit contact a qualified electrician DO NOT attempt to defeat this safety feature Always place humidifier on an elevated firm flat lev
2. Lift Handle Water Tank Water Tank Window Base Humidity Water Sensor Power Mist Control Knob Air Outlet Hear View Cleaning Brush Water Reservoir Ceramic Filter Tank Cap Ultrasonic Nebulizer Water Sensor Bottom Tank Handle Filling Ihe Water Tank CAUTION Always unplug the unit before removing the Water Tank Do not touch the water in the base NOTE Never fill the water tank from the top of the unit Follow Water Tank filling instructions in 3 2 E A E Use both hands and grab the Make sure to remove the Rotating handle on top of the Water Tank Mist Nozzle and then turn the Water to remove the humidifier from Tank upside down Remove the Tank the base Cap by turning it counterclockwise Fill the Water Tank with clean cool Attach Ceramic Filter included to tap water Do not use extremely the Tank Cap by aligning the lock cold water since it may temporar tabs on both and turning the cap ily reduce the mist output Never counterclockwise to lock When fill with hot warm water or add attached properly the Filter will additives as this could damage not fall from the Tank Cap the Unit and void the warranty Replace the Tank Cap by firmly Grab the Water Tank with both Attach Rotating turning clockwise until tight Turn hands and replace on the Humidi Mist Nozzle to the Water Tank upright and check fier Base make sure to follow the the top of the the Tank Cap for l
3. be voided if the unit is subjected to unauthorized repair or impact damage If you have any questions please call toll free 877 959 1234 9 Buipueg siuejeg jeuoneuJelu SN peneseH siu6lH Iy OTT suone ouu 1e849 e LOZO esuoneA ouu Jy d s cm J j y4 3 Available In Black amp Platinum TU PEU viU p
4. d fill the Base with enough solution to cover the Ultrasonic Nebulizer a Allow it to soak for an hour and then use the provided brush to gently loosen buildup on the Ultrasonic Nebulizer b Rinse out the Base with clean water and wipe clean with a soft cloth Ceramic Water Filter Cleaning Remove the Water Tank from the Humidifier Base Remove the Tank Cap c and rinse Water Filter thoroughly with tap water then replace on Water Tank d Surface Cleaning Clean all surfaces of the unit with a clean damp soft cloth CAUTION When emptying the Water Reservoir on the Base make sure that the water is poured away from the Air Outlet e If water is poured into the outlet it may damage the humidifier otorage 1 Follow all cleaning instructions prior to storage 2 Dry all parts including the inside of the Water Tank Never leave water inside the tank for several days 3 Leave the tank cap partially loosened to prolong the life of the cap 4 Preferably store in its original box in a dry place away from high temperatures 5 Follow all cleaning instructions after long periods of storage Troublesnooting PROBLEM Power Light is OFF POSSIBLE CAUSES a Unit is not plugged in b No power at outlet POSSIBLE SOLUTIONS a Plug in power cable b Check circuits fuses try a different outlet c Turn the Mist Control ON PROBLEM Weak or No mist output POSSIBLE CAUSES a No water in tank b Unit is n
5. eaks If any water shape of the Water Tank and the humidifier tank drips remove the Tank Cap and Humidifier Base as shown above retighten Do not place Water So that the tank sits level and flush Tank on the Humidifier Base if the to the base Ensure the tank is cap is leaking firmly seated Operating Instructions NOTE Do not operate the humidifier without water in the tank ON OFF Plug into a standard 120V AC electrical outlet Turn the Mist Control Knob clockwise until you hear a click and the Humidity Waterless indicator turns green To turn OFF turn the Mist Control Knob counterclockwise until you hear a click and the indicator turns OFF Mist Output The Unit will turn ON with the lowest mist setting Turn the Mist Control Knob clockwise to increase the mist output and turn the Mist Control Knob counterclockwise to decrease Mist may not appear immediately allow up to 15 minutes on the highest setting for the Base of the humidifier to fill Rotating Mist Nozzle Can be rotated 360 to position mist direction to desired location The Rotating Mist Nozzle can be rotated with the finger from the nozzle feature See Photo when the Mist Nozzle is in place Low Water When the tank is out of water the Humidity Waterless indicator will turn from green to red and the automatic safety shut off will turn the Ultrasonic Nebulizer OFF You may hear the fan for a few seconds this is normal Weekly Cleaning am
6. el surface where it s not easily knocked over e g on a table chest cabinet etc DO NOT place the appliance next to a heating vent under direct sunlight high temperature areas near computers or sensitive electronic equipment DO NOT place the appliance directly on wood furniture or other surfaces which could get damaged by water e g waterproof surface or mat NEVER use in an environment where explosive gases are present DO NOT use any attachments not provided with the unit NEVER use the appliance after a malfunction after it has been dropped or damaged in any other way Only operate when fully assembled Keep out of reach of children Close supervision is necessary when this appliance is used by or near children elderly or disabled persons NEVER drop or insert any object into any opening DO NOT block any air outlets or intakes NEVER cover the appliance when it s in operation To unplug turn controls to the OFF position then remove the plug from the outlet Ensure your hands are dry ALWAYS unplug and empty the water tank when not in use for a long period of time ALWAYS unplug before removing filling or emptying the water tank DO NOT wash adjust or move without first unplugging the unit DO NOT move appliance with water inside the tank In this case remove the water tank prior to moving DO NOT touch the water or any other part in the base during operation NEVER operate without water in the tank DO NOT use h
7. ot leveled c White Dust on Ultrasonic Nebulizer and or Water Sensor d Blower not operating e Water temperature too low f Ultrasonic Nebulizer not operating POSSIBLE SOLUTIONS a Fill tank with water and wait 10 15 minutes b Place unit on level surface c Clean Humidifier per instructions d Ensure water in Base is adequate to immerse the Water Sensor e Set output to High and wait for 10 15 minutes f See Warranty PROBLEM Peculiar Odor POSSIBLE CAUSES a If new unit b Dirty Water Tank or old water in tank c Minerals in well water or hard water POSSIBLE SOLUTIONS a Rinse Water Tank and Base and let air dry b Empty old water and clean Water Tank per instructions c Use filtered distilled cold boiled or bottled water PROBLEM White Dust on unit or nearby furniture POSSIBLE CAUSE a Hard water used POSSIBLE SOLUTION a Use filtered distilled cold boiled or bottled water PROBLEM Condensation forms around humidifier or windows POSSIBLE CAUSES a Mist output is set too high for room size b Direction of mist nozzle POSSIBLE SOLUTIONS a Decrease mist output b Change direction of mist nozzle PROBLEM Water is leaking POSSIBLE CAUSES a Tank cap not properly attached b Water tank not properly attached c Unit is not on level surface POSSIBLE SOLUTIONS a Follow item 4 on filling the water tank b Follow item 6 on filling the water tank c Place on level su
8. ot water in the tank ONLY use water in the tank never add any additive such as essential oils eucalyptus water conditioners etc to the water Please hold the water tank by the top handle when carrying full tank of water DO NOT attempt to repair or adjust the unit Servicing must be performed by professional or qualified personnel Discontinue use if unit makes loud noises or has a strange smell Perform regular maintenance of the Ultrasonic Nebulizer DO NOT direct the mist against a wall or other home appliance No More Dry Air Thank you for choosing the Air Innovations Clean Mist Ultrasonic Humidifier and congratulations on taking this important step in improving the quality of air in your home or office The Air Innovations Clean Mist Ultrasonic Humidifier uses Ultrasonic Technology to create humidity instantaneously while working silently to erase the discomforts of dry air Unpacking Remove packing material Carefully remove filter and humidifier from the box by pulling the base of the unit do not take the unit out of the box by pulling the tank Remove the plastic bag from the humidifier Follow directions to fill and operate the humidifier opecifications Product Model Power Consumption Rating Voltage Tank Capacity Dimensions Weight MH 408 30W 120V 4L 1 1 Gallon L8 X W8 2 9 Lbs X H14 38 2 Parts amp Contents le ONOnAR WD Rotating Mist Nozzle
9. p Care CAUTION Before cleaning always turn power off and unplug the unit from outlet DO NOT use any solvents or aggressive cleaning agents Keep water away from the Air Outlet DO NOT tamper with the Water Sensor About White Dust Use of high mineral content water may cause a white mineral residue to accumulate on room surfaces near the humidifier The mineral residue is commonly called white dust The higher the mineral content the harder your water is the greater the potential for white dust The white dust is not caused by a defect in the humidifier but is due only to minerals suspended in the water If you have hard tap water we recommend using only filtered distilled cold boiled or bottled water to minimize the white dust residue Tank Cleaning Remove the Rotating Mist Nozzle from the top of the Water Tank then remove the Water Tank Turn the tank upside down unscrew the Tank Cap and drain any water from the tank Wipe the tank with a soft damp cloth then rinse it with warm water inside and out Base Cleaning Gently wipe the base with a soft damp cloth do not immerse the Base in water Never scrape the Ultrasonic Nebulizer with a hard or sharp object White Dust Cleaning H mineral deposits White Dust are evident around the Ultrasonic Nebulizer and Water Sensor clean these surfaces with a soft cloth and a small amount of undiluted white vinegar If necessary mix a solution of 5096 white vinegar and 5096 water an
10. rface Ew Try These Other Great j FO LIFE Nae Products For Your Available at www qvc com amp www forlifeproducts com Air Purifiers Pursfection Rejuvenate Make it NEW Again 1 YEAR WARRANTY MH 408 Air Innovations Clean Mist Ultrasonic Humidifier comes with a 1 year manufac turer s warranty If this unit should become defective within 1 year from the date of purchase or if you have any questions or comments or regarding replacements for any of our products please contact us directly at Call us toll free at 877 959 1234 Monday thru Friday 8 30 AM to 5 00 PM EST Visit us on the web at www Greatlnnovations tv e mail us info greatinnovations tv Or write us Great Innovations LLC Att Quality Assurance Dept 2301 SW 145 Ave Miramar FL 33027 USA Please fill out the warranty card and mail back to the above address Or register your warranty online today Simply go to http www greatinnovations tv warranty php NAME ADDRESS CITY STATE Op TELEPHONE E MAIL DATE OF PURCHASE PLACE OF PURCHASE Please check here if you would not like to receive any solicitations from our company THIS UNIT COMES WITH A ONE YEAR WARRANTY SUBJECT TO THE FOLLOWING CONDITIONS In the first year all repairs will be performed free of charge or the unit will be replaced This warranty is not transferable it is valid only for the original purchaser This warranty will