1. ZZ WHYNTER ENERGY STAR 30 40 60 PINT PORTABLE DEHUMIDIFIER Model 4 RPD 321EW RPD 421EW RPD 621EW INSTRUCTION MANUAL ENERGY STAR i MANN iii DISPOSAL INFORMATION Thank vou for choosing the Whvnter Portable Dehumidifier Please follow the instructions provided in this user guide to obtain the verv best performance from vour dehumidifier We trust that vour Whvnter Portable Dehumidifier will provide the performance and reliability that we stand for Your Whynter Portable Dehumidifier is designed to remove moisture in the air by condensation removal and collecting the condensation water in the drain bucket or draining through a drain hose Please keep this user manual in a safe place for future reference This symbol on the product or its packaging indicates that the appliance can not be treated as normal domestic trash but must be handed in at a collection point for recycling electric and electronic appliances Your contribution to the correct disposal of this product protects the environment Further information about the recycling of this product can be obtained from your local municipal authority PAGE DISPOSAL INFORMATION 2 SAFETV PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS AND CONTROLS 6 9 OPERATION INSTRUCTIONS 10 11 WATER DRAINAGE INSTRUCTIONS 12 13 MAINTENANCE 14 TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 15 TROUBLESHOOTING 16 17 WARRANTY INFORMATION 18 SAFETV
2. steamy or wet areas e During installation the power supply must not be excessively or dangerously bent or flattened e Do not tamper with controls e Make sure the power plug is placed fully and firm into the wall socket If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements e Do not use multiple socket or of an extension cord as it may overheat and become a risk of fire e Make sure the power plug is clean before usage e Do not turn this appliance on and off by plugging and unplugging Always use the ON OFF switch e After turning the appliance off please take the power plug out of the socket e Make sure hands are dry when connecting the power plug The appliance is equipped with a three prong grounded plug on the power cord for your protection Never modify remove or attempt to repair the power plug yourself e Do not repair disassemble and or modify the appliance by yourself e Always turn off the appliance when cleaning the air filter and transporting e Atthe end of each season all water must be drained from the appliance and air filter must be cleaned before storage e Do not drink or use the water collected or drained from the appliance e Do not remove the drain bucket during operation e Transport the appliance in an upright position only or leav
3. with frost and may reduce performance Do not place the appliance near clothes dryer heater or radiator Shut all doors windows and openings to your target dehumidifying space for maximum performance Allow at least 10 of air space on all sides of the appliance for good air circulation and 20 or more above the appliance NOTE Dehumidifiers working in a basement will have little or no effect on adjacent enclosed rooms such as closets unless there is enough circulation of air in and out of the enclosed area If the appliance has been switched off and needs to be switched on again allow approximately three minutes for the correct operation to resume Select a suitable location and make sure you have easy access to the electrical outlet Ensure the air filter and drain bucket are correctly installed before switching the appliance on Always be careful when moving the appliance with a full drain bucket Ensure that the safety requirements and warnings detailed in this user manual are followed when operating this appliance 11 WATER DRAINAGE INSTRUCTIONS Using a portable dehumidifier requires that collected water be emptied frequentiv Draining water from this unit can be done in 2 different methods 1 DRAIN BUCKET METHOD In order for water to be collected in the drain bucket the continuous gravity drain hose assembly should be re moved from the drain outlet Close the drain outlet with the rubber drain cover 1 Whe
4. PRECAUTIONS TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURV WARNING WHEN USING VOUR PORTABLE DEHUMIDIFIER FOLLOW THESE BASIC PRECAUTIONS e Readall instructions before using the appliance e Neverclean appliance parts with flammable fluids The fumes can create a fire hazard Do not use an exces sivelv wet cloth industrial solvents and oil based products to clean this appliance e Do not store or use gasoline or any other flammable vapors and liquids in the vicinitv of this or any other appli ance The fumes can create a fire hazard e Do not abuse sit on or stand on the appliance e This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction con cerning use of the appliance by a person responsible for their safety e Children should be supervised to ensure that they do not play with the appliance e f the power cord is damaged it must be replaced by the manufacturer or its service agent or a similarly quali fied person in order to avoid a hazard e Please dispose of packing materials properly e Use the portable dehumidifier only for its intended function This appliance is designed for household non commercial use only Any other use will void the warranty e To avoid the risk of shock the product should never be used in bathrooms shower rooms or in any other
5. Portable Dehumidifier is an Energy Star rated appliance Follow the guide below can help to get the best performance and efficiency from your dehumidifier e Do not cover the air intake and outlet e Donotplace the appliance in front of curtains or drapes to ensure they do not obstruct the air intake e Keep curtains blinds or drapes closed during the sunniest part of the day e Close all windows and doors e Indoor relative humidity should ideally be kept between 35 RH and 60 RH depending on the ambient temperature e Make sure the appliance is on a hard and level surface e o prolong the compressor s life please wait at least 3 minutes before turning the appliance back on after shutting it off e Inspect and keep the air filter clean by cleaning regularly e Perform routine maintenance TECHNICAL DATA Refrigerant R410A 5 640z R410A 5 290z R410A 8 110z Air flow m h CFM 245 m h 144 CFM 245 m h 144 CFM 320 m h 188 CFM Unit Dimensions 15 4 W x 10 8 D x 23 2 H Unit Net Weight 397 bbs Unit Gross Weight 41 9 Ibs PARTS AND CONTROLS CONTROL PANEL HANDLE MOIST AIR INTAKE z DEHUMIDIFIED D DRY AIR VENT AIR FILTER gt DRAIN BUCKET ROLL CASTORS CONTINUOUS DRAINAGE OUTLET OTHER ACCESSORIES 1 20 Continuous Gravity Drain hose 2 Continuous 6 75 Gravity Drain short hose adapter and l SCTEWS PARTS AND CONTROLS TURBO FAN CLEAN INDICATOR LIGHT INDICATO
6. R LIGHT e FILTER BUTTON l 3 FAN Filte Turbo BUTTON Wa COMFORT TITLI OPERATION Comfort Full INDICATOR INDICATOR LIGHT te LIGHT Cont On Off Auto defrost m ETER 1 MODE e BUTTON Timer kaca AUTO DEFROST ON od AA INDICATOR LIGHT TIMER ON AND OFF INDICATOR LIGHT CONTINUOUS OPERATION INDICATOR LIGHT DOWN BUTTON UP BUTTON 1 Mode Button Press to select desired mode Comfort Continuous and Normal Continuous Mode Press the Mode Button to activate Continuous dehumidifying operation and the Continuous indicator light will illuminate when Continuous mode is in operation In this mode the unit will continue dehumidifying regardless of the room s humidity The Humidity Control Buttons are automatically disabled and the compressor will not stop unless the drain bucket is full or is removed Comfort Mode Press the Mode Button to activate Comfort Dehumidifying operation The Comfort Dehumidifying indicator light will come on when this mode is selected In this mode the unit will automatically control the room humidity in a comfortable range of 45 55 according to the room temperature The Humidity Control Buttons are auto matically disabled and the compressor will not stop unless the drain bucket is full removed or the humidity level reaches the comfort range percentage Normal Mode Press the Mode Button to activate Normal Dehumidifying operation The Comfort and Conti
7. The appliance will not operate satisfactorily if the room temperature is below 41 F Display The display screen shows a number of different indications depending on the selection function e Shows the set relative humidity level from 35 RH to 85 RH e Once the RH is set the set RH will stay on the display for about 5 seconds then it will revert back to current RH e Shows Auto Start and Auto Stop time from 0 0 hour to 24 hours e After the option settings are completed the display shows the approximate room humidity level in a range of 30 RH Relative Humidity to 90 RH Error Codes and Protection Code AS Humidity Sensor Error Unplug the unit and plug it back in gt i Sensor Unplug the unit and plug it back in i Empty the drain bucket PAA rA DUCKEL TUN Please make sure float moves freely and is not stuck Please make sure whether the environment temperature is EC Unit Malfunction between 41 F 5 C and 96 F 35 C E3 Unit Malfunction Unplug the unit and plug it back in Drain bucket is removed or not positioned correctly Make Eb Drain Bucket Error sure that the drain bucket is properly installed and the in right position Auto Restart In the event of a power outage appliance restarts at the previously set function mode and settings when power is restored not applicable to Timer Function AIR FILTERS INSTALLATION Your Whynter portable dehumidifier is equipped with a 2 in 1 silver co
8. ated washable pre filter combo This washable pre filter removes large particles such as dust pet hair and dander The silver coating is designed to kill bacteria in the air and control the growth of microbes such as viruses fungi and spores WARNING NEVER OPERATE THE DEHUMIDIFIER WITHOUT THE FILTER START OPERATION 1 Ensure that the appliance is connected to the power socket 2 Make sure the drain bucket is placed in proper position 3 Make sure filter is installed 4 When the unit is turned on for the first time if the bucket full lamp lights up just pull out the drain bucket then push it back to the proper position 5 Set the relative humiditv level RH by pressing the up and down buttons We recommend setting the RH to at least 10 lower than the current RH FILTER inside front U 10 OPERATION INSTRUCTIONS 20 or more Air Outlet U 10 or more Air Intake lt lt IM l 10 or more 10 or more lt gt 10 or more POSITIONING THE UNIT This dehumidifier is intended for indoor residential applications only and should not be used for commercial or industrial applications Place the dehumidifier on a smooth hard and level floor strong enough to support the appliance with a full bucket of water Do not attempt to roll the appliance over objects Avoid placing the appliance in an area where the temperature will fall below 53 F The coils may become cov ered
9. blems or allergies This Whynter Portable Dehumidifier which is perfect for larger rooms or areas in your home including a liv ing room or family room If your home is musty you will want to use your portable dehumidifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by controlling the relative humidity inside your home and a good idea in general if your home has such underlying problems as a leaky foundation walls or inadequate ventilation or if you live in a humid area By keeping the relative humidity indoors below 50 percent you can keep allergy inducing dust mites and mold from thriving 3 Basements If you have a basement that is below grade you should use your Whynter Portable Dehumidifier This de humidifier will help you keep the moisture levels in your basement down to manageable levels By doing this you can help keep your indoor furnace operating efficiently and even help eliminate minor standing water problems Your portable dehumidifier also can help keep furniture and valuables dry and it will help keep electronics in proper working order 4 Humid climates In humid climates such as areas near a beach or large body of water this Whynter Portable Dehumidifier can help keep the environment in your home at a more comfortable level While the actual temperature won t be affected you ll sleep more comfortably and may actually save money since your unit can keep the indoor humidi
10. e drain bucket is removed or not positioned correctly Make sure that the drain buck et is properly installed and the in right position 12 WATER DRAINAGE INSTRUCTIONS 2 CONTINUOUS GRAVITV DRAIN METHOD Water can be automaticallv emptied into a floor drain bv attaching the 20 continuous gravitv drain hose to the continuous gravitv drain outlet To use gravity to drain your portable dehumidifier it must be installed on a level surface or at least 12 inches above the ground on a sturdy table or shelf unit When using the function of continu ous gravity drainage your drain hose must be placed horizontally below the drainage hole Avoid uneven ground and folding the hose 1 Remove the rubber drain cover from the continuous gravity drain outlet at the back of the unit Plastic cover 2 Remove the drain bucket hr 3 Insert the continuous gravity drain hose assembly through Drain hose the continuous gravity drain outlet See Fig 3 assembly 4 From the front of the unit and with the drain bucket re moved make sure the continuous gravity drain hose is se curely inserted to the internal connector See Fig 4 Connector Drain hose assembly 5 Install the two screws provided to the continuous gravity drain hose adapter from the back of the unit 6 Attach the 20 continuous gravity drain hose Make sure the hose is securely fastened to prevent leakage See Fig D 7 Direct the drain hose toward a drain or
11. e it in an upright position for at least 2 hours before first use e When positioning or moving the appliance ensure that it is not turned upside down or greater than 45 or more off level e This appliance must be installed in an area protected from the element such as wind rain water spray or drips e Always place the appliance on even and hard and level surface that can support the unit when it is full of wa ter e Ensure objects are not obstructing the exhaust and air intake e Never insert your fingers or other objects into the air intakes and air outlets e Do not operate the appliance without the air filter THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED INTRODUCTION How it Works When the dehumidifier is started the fan begins to pull moisture laden air across the dehumidifving coils The coils condense or draw moisture from the air and air flows through the top louver into the room as dry warm air Moisture removed from air is collected in a drain bucket on the front of the dehumidifier The appliance is designed to operate between 41 F 5 C and 96 F 35 C The Compressor circuit has an automatic 3 minute time delayed start if the appliance is turned off and on quickly This prevents over heating of the compressor and possible circuit breaker tripping Make sure the drain bucket is fitted correctly otherwise appliance will not turn on Energy Saving Guide This Whynter
12. ent The dehumidifier leaks The dehumidifier does not operate Water on floor Continuous gravitv drain hose is loose Cracked drain bucket Power failure or outage The automatic switch line fuse or breaker has been tripped The power supply voltage is too low The power cord is damaged The dryness level you select ed has been reached Drain bucket is full or not positioned properly Drain bucket is not installed properly Drain hose connection may be loose or not installed properly 17 Secure the drain hose Contact Whynter Service Department Restore the power supply Flip the switch change the fuse turn the breaker back on Also note that you may have too many appliances drawing power on one circuit you may need to move the other appliances to another circuit Move the appliance onto another circuit with the correct voltage Call for service Only authorized person nel should replace damaged power cord or power plug If vou want to remove more moisture set the unit on Continuous operation Emptv drain bucket and insert the bucket to the appliance properiv Install the drain bucket securelv Make sure that the drain hose is securelv installed in the drain outlet For Drain Bucket method make sure that the continuous drain assembiv is not in stalled and rubber drain cover is in place For Continuous Gravitv Drain method make sure the hose is securelv fastened to prevent leaka
13. ge Direct the drain hose toward a drain or other suitable drainage outlet ONE YEAR LIMITED WARRANTY This WHYNTER portable dehumidifier is warranted to the original owner within the 48 continental states for one vear from the date of purchase against defects in material and workmanship under normal use and service Should vour WHVNTER portable dehumidifier prove defective within one vear from the date of purchase return the defective part or appliance freight prepaid within two months of purchase after two months to one year cus tomer will be responsible for freight cost to Whynter s service department along with an explanation of the claim to Whvnter LLC Please package the portable dehumidifier carefullv in its original packaging material to avoid damage in transit Please retain the original box and packaging material Under this warranty Whynter will repair or replace anv parts found defective This warrantv is not transferable After the expiration of the warrantv the cost of labor and parts will be the responsibilitv of the original owner of the appliance THIS WARRANTV DOES NOT COVER e Acts of God such as fire flood hurricanes earthquakes and tornadoes e Damage accidental or otherwise to the portable dehumidifier while in the possession of a consumer not caused bv a defect in material or workman ship e Damage caused bv consumer misuse tampering or failure to follow the care and special handling provisions
14. imer button to activate Auto start function and Timer light ON will come on Set the desired time delay ON hours by pressing the UP and DOWN buttons Once Timer Delay Switch On is placed press the Timer button again to activate Auto stop function and the Timer OFF light will come on Set the desired time delay OFF hours by pressing the UP and DOWN buttons When the delay time set has elapsed the appliance switches off To cancel the delayed switch off func tion set the time to OO or turn off the appliance Bucket Full Indicator The appliance will run continuousiv until the set RH is reached or when the drain bucket is full When the drain bucket is full the Full indicator light will illuminate and the dehumidifier will stop operating Remove the water in the bucket with two hands then place the drain bucket back to it s proper position and the machine will start operating again PARTS AND CONTROLS Auto Defrost Indicator In the event frost builds up on the evaporator coils the compressor will cvcle off and the fan will continue to run until the frost is evaporated This happens when the appliance is operating in low temperatures less than 53 F or 12 C which affects the efficiency of the dehumidifier When this happens the Auto Defrost light will turn on and the ma chine will go into periodic defrost mode automatically Defrost time may vary If the dehumidifier freezes up turn the appliance off for few hours and then restart
15. in the instructions e Damage to the finish of the case or other appearance parts caused bv wear e Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer e Freight and Insurance cost for the warranty service STOO Qucg DOG gt A SIIN JU O N 7 m U O m A U U O Mm m U gt lt D ES gt JI E DU D O ZU Z m L m gt AJ Z JIU O cz Z TOPMO JENLEL 202 M gt ZZE lt oz m m SPEVY HCJ0O CH T 7 A O GE C EL O Z U Z gt lt Z O gt U U Eg X H op lt O lt gt lt gt M Cp O sk gt lt m O al m AJ U Q I 4 04 L gt il gt DES gt ZJO lt H Pm gt lt z AD O zZ U H gt H m 14 O U H gt m To obtain service or information contact Whynter LLC via email at service whynter com or call 866 WHYNTER Product contents and specifications may change without notice Copyright 2015 Whynter LLC WWW WHYNTER COM 18
16. n the bucket is full the Full indicator light will light The com pressor and fan will turn off the Full indicator will light and a P2 code will be displayed 2 It is recommended to turn the unit off before removing the drain bucket 3 Grip the left and right handles of the drain bucket securely and carefully pull out the drain bucket Do not put the drain bucket on the floor because the bottom of the bucket is not even which may cause the water to spill See Fig 1 and Fig 2 4 Remove the water from the drain bucket and replace it back to the dehumidifier The drain bucket must be installed properly and securely seated for the dehumidifier to operate 5 The machine will restart when the drain bucket is restored in its correct position If the unit was turned off prior to the removal of the drain bucket press the Power button to restore operation e When vou remove the drain bucket do not touch anv inside parts of the unit Doing so mav damage the prod uct and result to injurv e Be sure to push the drain bucket gentiv all the wav into the unit Banging the bucket against anvthing or failing to push it in securelv mav cause the unit not to operate e Upon replacing the bucket firmly push the bucket in place until it locks There should be no gaps between the bucket and the dehumidifier e When the drain bucket is removed the unit will beep 8 times and the digital display shows Eb Eb is an error code that indicates that th
17. nto another circuit with the correct voltage Call for service Only authorized person nel should replace damaged power cord or power plug If you want to remove more moisture set the unit on Continuous operation Empty drain bucket and insert the bucket to the appliance properly Close all windows or doors You may need an additional dehumidifier for area Clean the air filter The appliance must be placed in a space that does not restrict air flowing into the rear coil or out of the front grille Set the RH level and the appliance will stop when the set RH is reached Set the humiditv level to a lower RH We recommend setting the RH to at least 10 lower than the current RH Ensure there is at least 10 of clearance for proper ventilation The appliance will not operate satisfacto rily if the room temperature is below 41 F Close windows or doors This is normal due to refrigerant rushing through the coil Frost will usually disap pear within 60 minutes This happens when the appliance is operating in low temperatures less than 53 F The appliance will not operate satisfacto rily if the room temperature is below 41 F Shut off the appliance and let it sit on lev el surface for at least 6 hours TROUBLESHOOTING Manv common portable dehumidifiers problems are easilv resolved Trv the troubleshooting suggestions below to see if the problems can be resolved before having to contact the service departm
18. nuous indicator lights will not illuminate when this mode is selected In this mode the dehumidifier can be set to a desired hu midity level and fan setting If the humidity level of the room is higher than the desired humidity setting the compressor will turn on If the humidity level of the room is lower than the desired humidity setting the com pressor will turn off 2 Filter Button The check filter indicator is a reminder to clean the air filter for more efficient operation The filter light will illuminate after approximately 250 hours of operation To reset after cleaning the filter press the Filter button and the light will turn off 3 Fan Button Press to select either Turbo or Normal fan speed Press the Fan button to engage Turbo Fan mode The Turbo light will illuminate Press the Fan button again to set the unit to Normal Fan mode The Turbo light will turn off when Normal Fan mode is activated PARTS AND CONTROLS 4 Power Button Press to turn the dehumidifier on and off 5 6 Up and Down Buttons e Humiditv Set Control Buttons The humidity level can be set within a range of 35 RH Relative Humidity to 85 RH in 5 increments For lower humiditv level press the Down button and set to a lower RH percentage value For higher humiditv level press the Up button and set to a higher RH percentage value Once the RH is set the set RH will stay on the display for about 5 seconds then it will revert back to current RH e Time
19. other suitable drain age outlet Make sure that there are no distortions with the hose that may stop the water flow 8 Place the drain bucket back into the unit and make sure that it is installed correctly 9 Select the desired humidity setting and fan speed on the unit for continuous draining to start 13 MAINTENANCE Always turn off and unplug the dehumidifier before cleaning 1 Cleaning the air grille and main unit Use a damp cloth to wrap the main unit or use water and a mild detergent Do not use bleach chemicals or abrasives Do not splash water directly onto the unit Doing so may cause an electrical shock cause the insulation to de teriorate or cause the unit to rust Use a vacuum attachment or brush to clean the air intake and outlet grilles 2 Cleaning the bucket 3 Cleaning the air filter er runs efficiently it is recommended to clean the air filter at least once every two weeks 4 End of Season Storage Clean the bucket to prevent growth of mold mildew and bacteria every two weeks Fill the bucket with clean warm water and add mild detergent to the water Dry thoroughly before reinserting the bucket to the main unit NOTE Do not clean the bucket in a dishwasher To ensure the air intake is filtered properly and to assure that your dehumidifi Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt Rinse the air filter under warm or cold running water no hotter
20. r Set Control Buttons If Timer Button is pressed use the Up and Down buttons to set the Auto Start and Auto Stop time from 0 0 hour to 24 hours Energy Saver When the unit is running on normal operation once the RH is reached the fan will still run continuousiv to avoid high start up amperage which makes the unit energy efficient Please note that the fan may run continuously or shut off intermittently depending on the RH and set humidity 7 Timer Button Press to activate the Timer delay feature in conjunction with the Down and Up Buttons e Timer Delay Switch Off When the appliance is ON press the Timer button to activate Auto stop function and the Timer OFF light will come on Set the desired time delay OFF hours by pressing the UP and DOWN buttons The time increments are 1 hour up to 24 hours When the delay time set has elapsed the appliance switch es off To cancel the delayed switch off function set the time to 00 or turn off the appliance Timer Delay Switch On When the appliance is OFF press the Timer button to activate Auto start function and Timer ON light will come on Set the desired time delay ON hours by pressing the UP and DOWN buttons The time increments are 1 hour up to 24 hours When the delay time set has elapsed the appliance turns on To cancel the delayed switch on function set the time to 00 or turn off the appliance Timer Delay Switch On and Off Sequence When the appliance is OFF press the T
21. than 100F Dry thoroughly before reinserting the air filter Reinstall the air filter and replace bucket securely After turning off the unit wait 24 hours before emptying the bucket to allow excess moisture to drain into the bucket Clean the main unit drain bucket and air filter as detailed above Cover the unit with the original plastic bag that came with the unit or any ap propriate dust cover Store the unit upright in a dry well ventilated place 14 TIPS ON WHEN TO USE VOUR PORTABLE DEHUMIDIFIER If vou have respiratorv problems asthma and allergies vour Whvnter Portable Dehumidifier is a great option for controlling moist environments Creating dry air can keep indoor air pollutants at a more manageable level espe cially when used in conjunction with an air purifier Using your portable dehumidifier can help you save money in the long run because it uses relatively little power and can help furnaces and air conditioners operate more efficiently 1 Excess moisture Indoor environments with excessive moisture can cause mold and fungus to thrive inside the walls and be neath the carpet Many types of mold are potentially dangerous and can lead to health problems This Whynter Portable Dehumidifier reduces the amount of moisture in the air inside a home which makes it far more difficult for harmful mold to grow This portable dehumidifier is also effective for a small area such as a hallway or bedroom 2 Respiratory pro
22. ty and thus your thermostat under control 15 TROUBLESHOOTING Manv common portable dehumidifiers problems are easilv resolved Trv the troubleshooting suggestions below to see if the problems can be resolved before having to contact the service department The dehumidifier does not operate The dehumidifier runs too much The dehumidifier runs but the room is not drv enough Frost appears on the coils above the bucket The dehumidifier makes loud noise Power failure outage The automatic switch line fuse or breaker has been tripped The power supply voltage is too low The power cord is damaged The drvness level vou selected has been reached Drain bucket is full or not positioned properly Windows or doors near dehu midifier are open Area to be dehumidified is too large Air movement through dehu midifier is blocked Air grille mav be dirtv Continuous mode is on Humidity setting RH is too high The dehumidifier does not have sufficient clearance to operate Room temperature is too low Windows or doors are opened The dehumidifier has been turned on recently Room temperature is too low Appliance is not leveled 16 Restore the power supply Flip the switch change the fuse turn the breaker back on Also note that you may have too many appliances drawing power on one circuit you may need to move the other appliances to another circuit Move the appliance o