1. GFCI Protected Receptacle Supply Stop Wrap the toilet seat with plastic wrap to prevent water from spraying from the toilet during testing Plug in the power cord Attach the clips evenly along the hose and power cord When the seat is plugged in the seat will go through a power up sequence where the wands will extend and retract and the power indicator LED will flash amber then green The seat is activated by skin to seat contact Unless otherwise stated the seat must be occupied to activate the functions To activate the seat controls for testing purposes when facing the toilet place your hand or a damp wash cloth on the right side of the seat approximately 1 3 from the front of the seat as illustrated Proceed to the Operation section of the Homeowners Guide to test the various seat functions Kohler Co 11 1054180 2 E Guide d installation Si ge de W C avec fonctionnalit bidet et chauffe eau en ligne Outils et mat riels Perceuse Cl molette Tournevis assortis Merci d avoir choisi la compagnie Kohler Nous appr cions votre engagement envers la qualit Kohler Veuillez prendre s il vous pla t quelques minutes pour lire ce manuel avant de commencer l installation Ne pas h siter nous contacter en cas de probl me d installation ou de performance Nos num ros de t l phone et notre adresse du site internet sont au verso Merci
2. Reposition the mounting plate as needed Reinstall the seat Repeat the adjustment procedure as needed until seat is properly aligned Once the seat is positioned as desired remove the seat and securely tighten down the mounting plate Reinstall the seat Kohler Co 7 1054180 2 E 5 Connect the Water Supply IMPORTANT Risk of product damage Use care not to crossthread or overtighten connections Hand tighten plus one quarter turn is sufficient for tightening IMPORTANT Risk of product damage Use care not to scratch the product surfaces O Connect the T valve directly to the toilet fill valve Connect the T valve to the toilet seat with the supplied hose Connect the water supply to the T valve Turn on the water supply Check all connections for leaks and make any adjustments as needed 1054180 2 E 8 Kohler Co Remote Holder If used apply tape here Screws Remote 6 Install the Remote Holder Choose a mounting location for the remote holder that is easily accessible while sitting on the seat O The remote holder can be installed using screws or double sided tape Choose your preferred method for securing the remote holder Follow only the instructions for your chosen installation method Install Using Screws NOTE Anchors may not be needed for installation to certain mate
3. Instale utilizando cinta adhesiva doble Retire el papel de un lado de cada cuadro de cinta adhesiva Instale un cuadro de cinta adhesiva en cada rea rectangular de la parte posterior del portacontrol remoto NOTA Antes de instalar el portacontrol remoto verifique que la depresi n rectangular est hacia abajo Retire el papel de los cuadros de cinta adhesiva Presione el portacontrol remoto en su lugar Cologue el control remoto en el portacontrol remoto con los iconos de preselecci n del usuario mirando hacia arriba 1054180 2 E Espa ol 9 Kohler Co Tomacorriente protegido por un interruptor GFCI Llave de paso 7 Verificaci n de la instalaci n Envuelva el asiento de inodoro con envoltura de pl stico para evitar que el agua del inodoro salpique durante la prueba Enchufe el cable el ctrico Conecte los clips de manera pareja a lo largo de la manguera y el cable el ctrico Al enchufar el asiento ste pasar por una secuencia de encendido donde las varillas se extender n y retraer n y el diodo LED indicador de encendido parpadear en color mbar y luego verde El asiento se activa por el contacto de la piel con el asiento A menos que se indique lo contrario para activar las funciones la persona debe ocupar el asiento Para activar los controles del asiento para fines de prueba estando de frente hacia el
4. location exposed to excessive moisture where condensation might form on the product surface Provide adequate ventilation when bathing to avoid damage to the electronic components due to high humidity levels 1054180 2 E 2 Kohler Co Before You Begin cont IMPORTANT Risk of product or property damage Pushing or pulling on the water connection may cause water leakage IMPORTANT Risk of product damage Do not apply excessive force to the spray wands Product may break Observe all local plumbing and building codes AI information in these instructions is based on the latest product information available at the time of publication Kohler Co reserves the right to make changes at any time without notice Do not use an extension cord with the product Connect to a cold water supply with a pressure of 20 80 psi 139 551 kPa O Connect only to cold water supply line carrying water of drinking guality Unplug the seat and drain the seat if the functions of the seat will not be operated for an extended period of time Kohler Co 3 1054180 2 E Seat lt a Grounded Outlet Grounding Pin N Grounding Screw Tab Cover Screw ENE B Grounded Outlet Box Preferred Connection Temporary Connection Wiring Reguirements Preferred Connection This product is for use on a nominal 120 VAC circuit and has a grounding plug that looks like th
5. de remplissage pour tout exc s d eau D D connecter le tuyau d alimentation d eau de la valve de remplissage du W C Kohler Co Fran ais 4 1054180 2 E Plaque de fixation 3 Installer la plaque de fixation Positionner la plaque de montage sur les orifices de fixation du W C O Glisser une rondelle sur chacun des boulons REMARQUE Certains W C sont pr munis d insertions filet es pr alablement install es dans les orifices de fixation Pour des W C avec insertions filet es V crou n est pas requis Pour des W C avec insertions filet es Ins rer un boulon dans la plaque de montage et positionner les rondelles de mani re a ce qu elles reposent dans les rainures des plaques de montage Visser l g rement les boulons dans les insertions Ne pas trop serrer Pour toutes les autres installations Positionner la plaque de montage sur les orifices de fixation du W C Glisser une rondelle sur chacun des boulons Ins rer un boulon dans la plague de montage et les orifices de fixation du W C Positionner les rondelles de mani re ce qu elles reposent dans les rainures de la plague de montage Glisser un crou sur chacun des boulons Serrer V crou a la main 1054180 2 E Francais 5 Kohler Co Plaque de 4 Installer le si ge Glisser le si ge dans la plaque de montage jusqu
6. encore d avoir choisi la compagnie Kohler Avant de commencer AVERTISSEMENT Risque de choc lectrique d incendie de blessures Ce produit doit tre mis la terre Connecter uniquement un circuit d di de 120 VAC 60 Hz prot g par un Disjoncteur de Fuite de Terre de classe GFCI de 15 Amp minimum ou de mise la terre ELCB AVERTISSEMENT Risque de choc lectrique ou d endommagement du produit Ne pas immerger ou purger le produit avec de l eau IMPORTANT Risque d endommagement du produit Ne pas brancher le si ge jusqu ce que toutes les autres tapes d installation soient compl t es Kohler Co Fran ais 1 1054180 2 E Avant de commencer cont IMPORTANT Risque d endommagement du produit Ne pas installer ce si ge dans un emplacement o l eau pourrait s clabousser sur le produit IMPORTANT Risque d endommagement du produit Ne pas installer ce si ge dans un emplacement excessivement expos Vhumidit ot de la condensation pourrait se former sur la surface du produit Fournir une ventilation ad quate lors de la prise de bain afin d viter un endommagement des composants lectroniques a cause de niveaux d humidit lev s IMPORTANT Risque d endommagement du produit Pousser ou tirer sur la connexion d eau pourrait causer une fuite d eau IMPORTANT Risque d endommagement du produit Ne pas appliquer de force excessive aux rallonges du vaporis
7. permitan puede realizar una conexi n provisional con un adaptador de dos clavijas siempre y cuando el adaptador est conectado a tierra 1054180 2 E Espa ol 3 Kohler Co Tomacorriente protegido por un interruptor GFCI 1 Instale una caja el ctrica ADVERTENCIA Riesgo de descarga el ctrica incendio o lesiones personales Este producto se tiene que conectar a tierra Conecte solamente a un circuito dedicado de 120 VCA 60 Hz protegido con un interruptor de circuito con p rdida a tierra GFCI de 15 A m nimo o un disyuntor de fuga a tierra ELCB O No utilice un cable de extensi n con este producto NOTA Cumpla con los c digos locales para determinar la ubicaci n de la caja el ctrica Instale los cables el ctricos e instale un tomacorriente de 120 V protegido por un GFCI o ELCB Debido a la longitud del cable el ctrico la caja el ctrica debe ubicarse a menos de 12 30 5 cm del inodoro 2 Preparaci n Desmonte el asiento de inodoro existente Cierre el suministro de agua al inodoro Accione la descarga del inodoro para aliviar la presi n que pueda haber en las mangueras de suministro de agua Coloque un recipiente debajo de la v lvula de llenado para colectar el exceso de agua O De la v lvula de llenado del inodoro desconecte la manguera de suministro de agua Kohler Co Espa ol 4 1054180 2 E Placa de montaje Tuerca
8. 3 Instale la placa de montaje Coloque la placa de montaje sobre los orificios de fijaci n del inodoro O Deslice una arandela en cada uno de los pernos NOTA Algunos inodoros vienen con insertos roscados instalados en los orificios de fijaci n Para inodoros con insertos roscados no se reguiere utilizar la tuerca Para inodoros con insertos roscados Inserte un perno en la placa de montaje y cologue las arandelas de manera gue descansen en las ranuras de las placas de montaje Atornille sin apretar los pernos en los insertos No apriete demasiado Para todas las dem s instalaciones Cologue la placa de montaje sobre los orificios de fijaci n del inodoro Deslice una arandela en cada uno de los pernos Inserte un perno a trav s de la placa de montaje y los orificios de fijaci n del inodoro Cologue las arandelas de manera gue descansen en las ranuras de la placa de montaje Enrosgue una tuerca en cada uno de los pernos Apriete la tuerca con la mano 1054180 2 E Espa ol 5 Kohler Co Placa de 4 Instale el asiento Deslice el asiento en la placa de montaje hasta que se sienta que encaja en su lugar NOTA La placa de montaje puede requerir ajuste para alinear correctamente el asiento Para ajustar la posici n del asiento quite el asiento presionando el bot n de desenganche y deslizando el asiento hacia dela
9. Installation Guide Toilet Seat with Bidet Functionality and In line Water Heater K 4709 M product numbers are for Mexico i e K 12345M Los n meros de productos seguidos de M corresponden a M xico e j K 12345M Francais page Francais 1 Espa ol pagina Espa ol 1 lies BOLDLOOK 1054180 2 E KOHLER Thank You For Choosing Kohler Company We appreciate your commitment to Kohler quality Please take a few minutes to review this manual before you start installation If you encounter any installation or performance problems please don t hesitate to contact us Our phone numbers and website are listed on the back cover Thanks again for choosing Kohler Company Tools and Materials Drill Adjustable Blade Wrench Screwdriver Before You Begin AN WARNING Risk of electric shock fire or personal injury This product must be grounded Connect only to a dedicated 120 VAC 60 Hz circuit protected by a minimum 15 Amp Ground Fault Circuit Interrupter GFCI or Earth Leakage Circuit Breaker ELCB AN WARNING Risk of electric shock or product damage Do not immerse or flush the product with water IMPORTANT Risk of product damage Do not plug in the seat until all other installation steps have been completed IMPORTANT Risk of product damage Do not install this seat in a location where water might be splashed on the product IMPORTANT Risk of product damage Do not install this seat in a
10. ateur Le produit peut casser Respecter tous les codes de plomberie et de b timent locaux Tous les renseignements contenus dans ces instructions sont bas s sur les donn es les plus r centes relatives au produit au moment de la publication Kohler Co se r serve le droit d apporter des modifications 4 tout moment sans pr avis Ne pas utiliser de rallonge avec ce produit Connecter a une alimentation d eau froide avec une pression de 20 80 psi 139 551 kPa Connecter uniquement la ligne d alimentation d eau froide de qualit potable D brancher le si ge et purger le si ge si les fonctions de celui ci n op rent pas pour de longues p riodes Kohler Co Fran ais 2 1054180 2 E Adaptateur Si ge X sas Vis de mise ER ol Prise mise a la terre terre ii Cache vis ige de aa o terre x Bo tier de prises mis la terre Connexion pr f rable Connexion temporaire C blage requis Connexion pr f rable Ce produit est pour une utilisation sur un circuit nominal de 120 VAC et qui est muni d une prise de terre similaire celle illustr e L utilisation d un circuit voltage plus lev est dangereux et on a6 i pourrait r sulter en un incendie ou autre accident Connexion temporaire IMPORTANT A moins que la vis du couvercle soit mise la terre travers le c blage du logement la fixation de la lang
11. ce qu elle s enclenche en place REMARQUE La plaque de montage devra peut tre tre ajust e pour s aligner correctement avec le si ge Pour ajuster la position du si ge retirer celui ci en pressant sur le bouton de rel che et en le glissant vers l avant Repositionner la plaque de fixation selon le besoin R installer le si ge R p ter la proc dure d installation selon le besoin jusqu ce que le si ge soit correctement align Une fois le si ge positionn selon le d sir le retirer et bien serrer la plaque de montage R installer le si ge Kohler Co Fran ais 6 1054180 2 E Joint Valve en T Tuyau Arr t d alimentation iG D 5 Connecter l alimentation d eau IMPORTANT Risque d endommagement du produit Utiliser des pr cautions afin de ne pas fausser les pas ou trop serrer les connexions Serrer la main d un quart de tour en plus est suffisant IMPORTANT Risque d endommagement du produit Faire attention de ne pas rayer les surfaces du produit D Connecter la valve en T directement la valve de remplissage du W C Connecter la valve en T du si ge du W C avec le tuyau fourni Connecter l alimentation d eau la valve en T Ouvrir Valimentation d eau V rifier s il y a des fuites dans les connexions et faire tous les r glages au besoin 1054180 2 E Fran ais 7 Ko
12. e plug illustrated Using a higher voltage circuit is dangerous and may result in a fire or other accident Temporary Connection IMPORTANT Unless the cover screw is grounded through the house wiring attaching the adaptor grounding screw tab to the cover screw will NOT ground the unit If there is any doubt whether the cover screw is grounded have it checked by a gualified electrician or service professional A temporary connection with a two prong adaptor may be made where local codes permit provided that the adaptor is grounded 1054180 2 E 4 Kohler Co GFCI Protected Receptacle Supply Stop 1 Install an Electrical Outlet WARNING Risk of electric shock fire or personal injury This product must be grounded Connect only to a dedicated 120 VAC 60 Hz circuit protected by a minimum 15 Amp Ground Fault Circuit Interrupter GFCI or Earth Leakage Circuit Breaker ELCB O Do not use an extension cord with the product NOTE Follow local codes when determining the electrical outlet location Route the electrical and install to a 120 V GFCI or ELCB protected receptacle The electrical outlet should be located within 12 30 5 cm of the toilet to accommodate the length of the power cord 2 Preparation Remove the existing toilet seat Turn off the water supply to the toilet Flush the toilet to relieve any pressure from the water supply hos
13. el asiento O El portacontrol remoto se puede instalar utilizando tornillos o cinta adhesiva doble Elija el m todo de preferencia para fijar el portacontrol remoto Siga solamente las instrucciones para el m todo de instalaci n que haya elegido Instale utilizando tornillos NOTA Los anclajes no son necesarios para la instalaci n a ciertos materiales Utilice los herrajes de montaje adecuados para la superficie de instalaci n en particular Coloque el portacontrol remoto en el lugar de montaje deseado con la depresi n rectangular hacia abajo como se muestra Marque con un l piz el lugar de los dos orificios de fijaci n Coloque el portacontrol remoto a un lado O Para la instalaci n a un poste u otra superficie de madera Taladre un orificio de 1 16 en cada lugar marcado Para la instalaci n utilizando anclajes de pared Taladre un orificio de 1 4 en cada lugar marcado Instale los anclajes de pared en los orificios Coloque el portacontrol remoto sobre los orificios de fijaci n de manera que la depresi n rectangular est hacia abajo Fije el portacontrol remoto con los tornillos Kohler Co Espa ol 8 1054180 2 E Instale el portacontrol remoto cont Instale los cubre tornillos para cubrir los tornillos Coloque el control remoto en el portacontrol remoto con los iconos de preselecci n del usuario mirando hacia arriba
14. es Position a container under the fill valve to catch any excess water Disconnect the water supply hose from the toilet fill valve Kohler Co 5 1054180 2 E Mounting Plate 3 Install the Mounting Plate Position the mounting plate over the toilet mounting holes Slide a washer onto each of the bolts NOTE Some toilets come with threaded inserts pre installed in the mounting holes For toilets with threaded inserts the nut is not required For Toilets with Threaded Inserts Insert a bolt through the mounting plate and position the washers so they rest in the grooves of the mounting plates Loosely thread the bolts into the inserts Do not overtighten For All Other Installations Position the mounting plate over the toilet mounting holes Slide a washer onto each of the bolts Insert a bolt through the mounting plate and the toilet mounting holes Position the washers so they rest in the grooves of the mounting plate Thread a nut onto each of the bolts Handtighten the nut 1054180 2 E 6 Kohler Co Mounting 4 Install the Seat Slide the seat onto the mounting plate until you feel it snap into place NOTE The mounting plate may need to be adjusted to properly align the seat To adjust the seat position remove the seat by pressing in the release button and sliding the seat forward
15. hler Co Support de t l commande Si utilis appliquer du ruban ici T l commande poo J 7 q A S 6 Installer le support de t l commande Choisir un emplacement de montage pour le support de la t l commande qui est accessible en position assise sur le si ge O Le support de t l commande peut tre install en utilisant des vis ou un ruban adh sif double face Choisir la m thode pr f r e pour s curiser le support de t l commande Suivre uniquement les instructions pour installation choisie Installer en utilisant des vis REMARQUE Des ancrages peuvent ne pas tre n cessaires pour l installation certains mod les Utiliser une boulonnerie de montage ad quate pour la surface particuli re de votre installation Positionner le support de t l commande l emplacement d sir de montage avec le renfoncement vers le bas tel qu indiqu Marquer au crayon l emplacement des deux orifices de fixation Mettre le support de c t O Pour une installation un montant ou autre surface en bois Percer un orifice de 1 16 chacun des emplacements marqu s Pour une installation utilisant des ancrages muraux Percer un orifice de 1 4 chacun des emplacements marqu s Ins rer les dispositifs d ancrage dans les orifices Positionner le support de t l commande sur les orifices de fixation de mani re ce que
16. il entrera dans une s quence de mise sous tension o les rallonges s tendront et se r tracteront et la DEL indicatrice de courant clignotera en couleur ambre puis verte Le si ge est activ par contact peau si ge A moins que mentionn autrement le si ge doit tre occup pour activer les fonctions Pour activer les contr les du si ge pour effectuer des tests en faisant face au W C placer la main ou un chiffon humide sur le c t droit du si ge approximativement 1 3 de l avant de ce dernier tel qu illustr Proc der la section Op ration du guide du propri taire pour tester les diverses fonctions du si ge Kohler Co Fran ais 10 1054180 2 E Gu a de instalaci n Asiento de inodoro con funcionalidad de bidet y calentador de agua en l nea Herramientas y materiales Taladro Llave Destornillador ajustable plano Gracias por elegir los productos de Kohler Le agradecemos que haya elegido la calidad de Kohler Dedique unos minutos para leer este manual antes de comenzar la instalaci n En caso de problemas de instalaci n o de funcionamiento no dude en contactarnos Nuestros n meros de tel fono y nuestro sitio web se encuentran en la cubierta posterior de esta gu a Gracias nuevamente por escoger a Kohler Antes de comenzar ADVERTENCIA Riesgo de descarga el ctrica incendio o lesiones personales Este producto se tiene que conectar a tierra Conec
17. inodoro coloque su mano o una toallita h meda en el lado derecho del asiento aproximadamente 1 3 del frente del asiento como se ilustra Proceda a la secci n Funcionamiento de la Gu a del Usuario para probar las diferentes funciones del asiento Kohler Co Espa ol 10 1054180 2 E USA 1 800 4 KOHLER Canada 1 800 964 5590 M xico 001 877 680 1310 kohler com THEBOLDIOOK OF KOHLER 2006 Kohler Co 1054180 2 E
18. le renfoncement rectangulaire soit orient vers le bas Kohler Co Fran ais 8 1054180 2 E Installer le support de t l commande cont S curiser le support de t l commande avec les vis Installer les capuchons pour couvrir les vis D Positionner la t l commande dans le support avec les ic nes de pr r glage de l utilisateur orient es vers le haut Installer en utilisant du ruban adh sif double face Retirer le papier d un c t de chaque carr du ruban Installer le carr de ruban dans chacun des emplacements rectangulaires localis s l arri re du support de t l commande REMARQUE Avant de monter le support de t l commande v rifier que le renfoncement rectangulaire soit orient vers le bas Retirer le papier des carr s de ruban Presser le support de t l commande en place Positionner la t l commande dans le support avec les ic nes de pr r glage de l utilisateur orient es vers le haut 1054180 2 E Fran ais 9 Kohler Co Receptacle prot g GFCI Arr t d alimentation 7 V rification de installation Envelopper le si ge du W C avec du plastique afin d viter V claboussement d eau du W C durant le test Brancher le cordon d alimentation Attacher les clips de mani re gale le long des tuyaux et du cordon d alimentation Lorsque le si ge est branch
19. nte Mueva la placa de montaje seg n sea necesario Vuelva a instalar el asiento Repita este procedimiento de ajuste seg n sea necesario hasta que el asiento est correctamente alineado Una vez que el asiento est en la posici n deseada quite el asiento y apriete con seguridad la placa de montaje Vuelva a instalar el asiento Kohler Co Espa ol 6 1054180 2 E Empaque V lvula en T Manguera Manguera Llave de paso 8 D 5 Conecte el suministro de agua IMPORTANTE Riesgo de da os al producto Tenga cuidado de no da ar las roscas ni apretar demasiado las conexiones Es suficiente apretar a mano m s un cuarto de vuelta IMPORTANTE Riesgo de da os al producto Tenga cuidado de no rayar la superficie del producto O Conecte la v lvula en T directamente a la v lvula de llenado del inodoro Conecte la v lvula en T al asiento del inodoro con la manguera provista Conecte el suministro de agua a la v lvula en T O Abra el suministro de agua Revise todas las conexiones para asegurarse que no haya fugas y ajuste seg n sea necesario 1054180 2 E Espa ol 7 Kohler Co Portacontrol remoto Si la utiliza apligue cinta aqui Control remoto 6 Instale el portacontrol remoto Elija un lugar de montaje para el portacontrol remoto gue sea f cilmente accesible mientras est sentado en
20. r momento sin previo aviso O No utilice un cable de extensi n con este producto Conecte al suministro de agua fr a con una presi n de 20 80 psi 139 551 kPa Conecte s lo a una l nea de agua fr a de calidad para beber Si las funciones del asiento no se utilizar n por un periodo prolongado de tiempo desenchufe el asiento y el drene el asiento Kohler Co Espa ol 2 1054180 2 E Adaptador Asiento Tomacorrientes i ot conectado a tierra engueta del tornillo e de conexi n o ror de a tierra Clavija de N Caja el ctrica con la tapa conexi n a tierra conexi n a tierra Conexi n de preferencia Conexi n provisional Requisitos de cableado Conexi n de preferencia Este producto se debe utilizar con un circuito nominal de 120 VCA y tiene un enchufe de conexi n a tierra parecido al enchufe ilustrado El uso de un circuito de voltaje m s alto es peligroso y podr a ocasionar un incendio u otro accidente Conexi n provisional IMPORTANTE A menos que el tornillo de la tapa tenga conexi n a tierra a trav s del cableado de la casa el fijar la leng eta del tornillo de conexi n a tierra del adaptador al tornillo de la tapa NO conectar la unidad a tierra Si tiene alguna duda de si el tornillo de la tapa est conectado a tierra solicite la verificaci n por un electricista calificado o profesional de servicio O Donde los c digos locales lo
21. rials Use the appropriate mounting hardware for your particular installation surface Position the remote holder at the desired mounting location with the rectangular indent toward the bottom as shown Using a pencil mark the two mounting hole locations Set the holder aside O For installation to stud or other wood surface Drill a 1 16 hole at each of the marked locations For installation using wall anchors Drill a 1 4 hole at each of the marked locations Install the wall anchors into the holes Position the remote holder over the mounting holes so the rectangular indent is toward the bottom Secure the remote holder with the screws Kohler Co 9 1054180 2 E Install the Remote Holder cont Install the caps to cover the screws Position the remote into the holder with the user preset icons facing up Install Using Double Sided Tape Remove the paper from one side of each of the tape squares Install a tape square in each of the rectangular areas located on the back of the remote holder NOTE Before mounting the remote holder verify the rectangular indent is toward the bottom Remove the paper from the tape squares Press the remote holder into place Position the remote into the holder with the user preset icons facing up 1054180 2 E 10 Kohler Co 7 Installation Checkout
22. te solamente a un circuito dedicado de 120 VCA 60 Hz protegido con un interruptor de circuito con p rdida a tierra GFCI de 15 A m nimo o un disyuntor de fuga a tierra ELCB ADVERTENCIA Riesgo de descarga el ctrica o de da os al producto No sumerja ni lave el producto con agua IMPORTANTE Riesgo de da os al producto No enchufe el asiento hasta haber terminado todos los dem s pasos de la instalaci n Kohler Co Espa ol 1 1054180 2 E Antes de comenzar cont IMPORTANTE Riesgo de da os al producto No instale este asiento en un lugar donde pueda salpicar agua en el producto IMPORTANTE Riesgo de da os al producto No instale este asiento en un lugar expuesto a humedad excesiva donde se pueda formar condensaci n en la superficie del producto Provea suficiente ventilaci n al ba arse para evitar da os a los componentes el ctricos por altos niveles de humedad IMPORTANTE Riesgo de da os al producto o a la propiedad Jalar o empujar la conexi n de agua puede causar fugas de agua IMPORTANTE Riesgo de da os al producto No aplique fuerza excesiva a las varillas rociadoras El producto se puede romper Cumpla con todos los c digos locales de plomer a y de construcci n Toda la informaci n contenida en estas instrucciones est basada en la informaci n m s reciente disponible al momento de su publicaci n Kohler Co se reserva el derecho de realizar cambios en cualquie
23. uette adaptatrice de mise la terre N isolera PAS la terre cette unit Si il y a quelque doute que ce soit quant l isolation de cette vis la faire v rifier par un lectricien qualifi ou un service professionnel Une connexion temporaire avec un adaptateur deux broches peut tre cr l o les codes locaux le permettent ceci tant que l adaptateur soit mis la terre 1054180 2 E Fran ais 3 Kohler Co Receptacle prot g GFCI t O YA Arr t d alimentation 1 Installer la prise de courant AVERTISSEMENT Risque de choc lectrique d incendie de blessures Ce produit doit tre mis la terre Connecter uniquement un circuit d di de 120 VAC 60 Hz prot g par un Disjoncteur de Fuite de Terre de classe GFCI ou de mise la terre ELCB Ne pas utiliser de rallonge avec ce produit REMARQUE Suivre les codes locaux lors de la d termination de l emplacement de la prise lectrique Acheminer le service lectrique et installer un r ceptacle prot g par un GFCI 120 V ou un ELCB La prise lectrique devrait tre localis e dans les 12 30 5 cm du W C pour accommoder la longueur du cordon d alimentation 2 Pr paration Retirer le si ge du W C existant Couper l alimentation d eau du W C Purger le W C pour rel cher toute pression des tuyaux d alimentation d eau Positionner un r cipient sous la valve

Download Pdf Manuals

image

Related Search

Related Contents

[取扱説明書ー  DPI_PerformanceOptim.. - Computer Engineering  Manual de Usuario – VIA G  Sony NHS-2000 User's Manual  PanelMate Power Series Power Pro Pro LT Installation Guide  8 IN 1 DIAGNOSE WAAGE MIT BLUETOOTH  User`s Manual - Sage ACT! add-ons  PRO-SERIES 800388 Instructions / Assembly    Mode d`emploi  