Home
        Barclay Products TKCTRN60-SN4 Installation Guide
         Contents
1.  holding riser pipe of Converto shower  if previously  purchased  The headless set screw is used for attaching the riser pipe to the tee     4 14 09 P 847  244  1234   www barclayproducts com    
2. Tub Wall Mounted fA  Cat  No     Faucet with    Hand Shower 4602 BARCLAY  INSTALLATION INSTRUCTIONS    Parts Included  e 1 Valve Body w  Elephant Spout    1 Shower Head    1 Hose    1 Cradle    4 Washers       2 Adjustable Swivel Mounts       e 2 Metal Washers     2 Large Locknuts       2 Connector Nuts       2 Threaded Nipples       Tools Needed  e Adjustable Wrench    Slip Joint Pliers    Pipe Putty or Teflon Pipe Tape       NOTE  Handles are identified HOT and COLD  The hot handle must be to the left and cold to the right   Be sure the water supply is turned off before starting installation  Cushion the wrench or slip    joint pliers with an old cloth to protect the finish of the fixture     shower head           hose ol  Shower Assembly  amp  Tub Mount Instructions washer  1  Align the valve assembly with the swivel mounts and secure with Ma S  the nuts on the swivel mounts  Rubber washer must be in place     i i  1 per side   Tighten with a wrench       Note  Mounts may be positioned up or down depending how high hose    you would like the spout placed and the hole spacing     2  Apply teflon tape to both ends of the hot and cold supply nipples   Thread the tapered ends of the nipples into the swivel mounts  on the outside of the tub  Thread the large locknuts and metal washers  onto the other ends of the nipples and secure the shower set to the tub   Position the threaded hose outlet to the left or right     3  Install a washer in the cradle nut and thread the cradle on
3. flange    B  Measure the distance from the center of the wall flange to the ceiling  Important  From this measurement  deduct one 1 2     This will give you the length of the ceiling support rod needed  If the ceiling support rod must be  shortened  cut the non threaded end of the rod to the length desired by using a hacksaw  Attach the flange with a set  screw to the non threaded end and then attach the ceiling support rod to the ceiling tee  2      3  Screw the wall support rod  6  to the wall tee  5   Place wall support into flange previously mounted on wall  see 2A    Determine if the wall support rod should be shortened  The wall tee  5  should be approximately even with the front  rim of the tub when viewed from the side  If necessary  cut the non threaded end of the support rod     4  Again  place the wall support rod  6  into the flange which is attached to the wall  The ceiling flange should now be  touching the ceiling  Mark the location of the holes of the ceiling flange on the ceiling with a pencil  Drill holes where  marked on the ceiling  Remove the ceiling flange from the ceiling support rod  3   Install the ceiling flange using the  wood screws  If necessary use plastic expansion plugs  not provided   It is important that the ceiling flange be  mounted as securely as possible     5  Insert wall support rod into wall flange and ceiling support rod into flange then tighten the set screws securely     Note  Wall support tee  5  has additional hole through tee for
4. n shoe        Cleaning Instructions 5  Trim bottom of tube  1 to fit into Tee   5    Wipe this whole set off with warm water and a 6  Trim tube  11 to fit    soft cloth  DO NOT use soaps  cleansers  or   brass cleaners as they will disintegrate the 7  Tighten the nuts     protective lacquer coating and leave the brass  exposed causing it to tarnish     NOTE  Please seek professional help if you have copper plumbing in your home   1 8 08 P 847  244  1234   www barclayproducts com    Rectangular Cat  No  LA    Shower Rod Unit PSDA BARCLAY    INSTALLATION INSTRUCTIONS    Parts Included   e 2 Curtain Frame Sections    1 Wall Tee     1 Ceiling Tee      e 1 Wall Support 10    Long    1 Ceiling Support 30    Long    2 Flanges     e 4 Wood Screws    10 Set Screws w  Heads    1 Headless Set Screw       ie  3 Tie         _ a  he            i   iat     Side Wall Support       ogo  1  Connect both halves of the curtain frame  1  using the ceiling tees and wall tees as shown above  In order to insure a  solid fit  the tees fit snugly over the frame tube  Install 4 set screws in each tee     2  Remove wall support  6   ceiling support  3  and 2 flanges  4  from the carton  Determine the correct length of the  support rods as follows    A  Hold one flange  4  to the wall at desired height from the inside of the tub and centered over the tub    Mark the position of the holes to be drilled  Fasten the flange to the wall with the wood screws  keeping the set screw  hole on the top side of the 
5. screws  Use anchors if necessary   d  Slide threaded end of top supply tube into tube fasteners     6  Assemble supply tube into top of stop valve  Tighten screws on tube fastener     Cleaning Instructions  Wipe this whole set off with warm water and a soft cloth  DO NOT use soaps  cleansers  or brass cleaners as they will    disintegrate the protective lacquer coating and leave the brass exposed causing it to tarnish     NOTE  The Gold Nuts are extra pieces for use with your plumbing  They are not necessarily needed for your installation   Please seek professional help if you have copper plumbing in your home     3 22 12 P 847  244  1234   www barclayproducts com    Leg Tub Cat  No  4      Drain 9999 BARCLAY  INSTALLATION INSTRUCTIONS    Parts Included  e Top Overflow Tube  1    Bottom Shoe  2      Top Waste Flange  3    Face Plate  4    Exposed Tee  5      e Face Sponge Gasket  6  e Waste Gasket  7     Lift Stop  8     2  1 1 2    Nut and Washers  9     Face Plate Screw  10        1 1 2    x 6    Tube  11      1 1 2    O D  Escutcheon  12        Tools Needed  e Wrench    Pliers     Teflon Tape  use as a sealant on all male threaded tubing    Tube Cutter   Plumbers Putty          To Assemble Tubes    1  Assembled  3 and  8 screw into  2    7 is on top of  2 beneath the tub   Place a bead of plumbers putty around  bottom of  3  to seal to tub and protect  from leaks  Then tighten  3 into  2     2  Assemble overflow   Follow diagram   3  Set  1 in place     4  Place Tee   5  o
6. ted to a Stop Valve   14 Screws    14 Anchors e   e 2 Connecting Nuts and 2 Flat Rubber Washers    2 Flat Floor Flanges    2 Wall Mounts    2 Wall Support Tubes    2 Tube Fasteners e    Tools Needed  e Wrench    Pliers   Teflon Tape  use as a sealant on all male threaded tubing      This water supply tube kit includes the parts listed above ONLY  The faucet in your bathtub should  be purchased previously and separate from this kit  This should NOT be used with faucets that use shower risers  and shower rods  or with leg tubs that have factory drilled holes        Wall Supports       1  First be sure to shut off the the water supply  Remove old water supply tubing  Place a flat rubber washer onto the  upper end of each supply tube     2  Screw flat floor flange on to 5    shaft with stop valve attached  Be sure to leave enough thread to go through  floor  to attach to your plumbing     3  Screw flange back down till level with floor  Attach to floor with provided screws     4  If rubber washers are inside connecting nuts remove them  Slide connecting nut over the thread end of the  supply tubes and up over the fittings  So that the fittings are completely inside the connecting nuts  Place  washers deep inside of connect nuts     5  When fastening supply tube to wall mounts   a  Attach wall mount flanges to the wall support tubes   b  Attach tube fasteners to wall support tubes and tighten screws   c  Decided where supports will be attached to the wall and fasten with provided 
7. to the valve    l i valve assembly  assembly  Tighten with a wrench     4  Install washers on the hose ends and attach the hose to the cradle and shower head handle   DO NOT OVERTIGHTEN     5  Attach cold water supply pipe to cold water side of valve assembly  Same with hot on other side     To Connect Shower Set to Tubes  NOT INCLUDED     1  First remove the round rubber washer from the end of each water supply tube and dispose of them     2  Put the cone washers on the tub and connect the end of each water supply tube  Then slide the 1 2    connecting  nuts over the opposite ends of the supply tubes and up to the cone washers     3  Twist the connecting nuts over the cone washers and thread the nuts onto the nipples     4  Connect the other ends of the water supply tubes to your house water lines  Consult your local plumber for  assistance     NOTE  Please seek professional help if you have copper plumbing in your home     Cleaning Instructions  Wipe this whole set off with warm water and a soft cloth  DO NOT use soaps  cleansers  or brass cleaners as    they will disintegrate the protective lacquer coating and leave the brass exposed causing it to tarnish     2 13 08 P 847  244  1234   www barclayproducts com    Freestanding Bath Cat  No          Supplies 4502 PL BARCLAY  ASSEMBLY INSTRUCTIONS     These instructions are for assembly of bath supplies ONLY not for connection to water supply     Parts Included   e Left Supply Tube    Right Supply Tube    2  Shafts each connec
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Desa GWN10 User's Manual  Betriebsanleitung  HP Grill Accessory B User's Manual  Samsung B100 Uživatelská přiručka  Manual - Northern Tool + Equipment  Respiratory (PDF 16MB)  Smeg CSU2001B1 Instructions for Installation and Use    REVELPROG IS - User Manual ()  instailatiûnandgperaï`ing instructions montage et mode d`emploi    Copyright © All rights reserved. 