Home
Mr. Steam MSSUPER3EC1 Installation Guide
Contents
1. Field Wiring Step 7 Temporarily short out the WLS Purple wire and GND Green wire terminals and verify the contactor engages Step 8 When the red light is on verify 24 VAC RED amp WHT RED wires to the contactor Step 9 Check main voltage on the load side of the contactor when it is engaged Step 10 If all steps on the power path were verified turn off power to the unit and pull the heating element via the left hand access panel for inspection DO NOT disassemble internal components internal components contain no serviceable parts All drawings are for illustrative purposes only mr steamr Installation Operation amp Maintenance Manual SYSTEM STATUS CODES The control either iSteam iTempo or iTempo Plus may display a status code if the steam generator is not functioning properly Code Code Meaning Probable Cause Suggested Remedy H20 Water level is not satisfied within 5 min Water Supply is off Turn on Water Supply Defective water feed solenoid Check replace water solenoid valve Water feed probe not functioning Check clean probe Check probe wiring Drain Valve Open Check Close drain valve AutoFlush not functioning Check Replace AutoFlush Prr1 Temperature Probe Error or Prr2 Control cable MSTS cable cut Replace control cable MSTS Internal problem with control MSTS Replace control MSTS Err1 Incorrect Field Supply Voltage
2. fo Installation Operation and Maintenance Manual Steambath Generator Systems Residential Models MS90E MS400E and MSSUPERTE 6E mr steam Feel Good Inc READ ME FIRST NISIDTS As you follow these instructions you will notice warning and caution symbols This blocked information is important for the safe and efficient installa tion and operation of this generator These are types of potential hazards that may occur during installation and operation NIZSIDTS Indicates a potentially hazardous situation which if not avoided could result in death or serious injury NSTXTHITSI Indicates a potentially haz ardous situation which if not avoided may result in minor or moderate injury or product damage IMPORTANT NOTE This highlights information that is especially relevant to a problem free installation All information in these instructions is based on the latest product information available at the time of publication Sussman Automatic Corporation reserves the right to make changes at any time without notice When installing and using this electrical equipment basic safety precautions should always be followed including the following IMPORTANT SAFETY INSTRUCTIONS 1 READ AND FOLLOW ALL INSTRUCTIONS 2 DO NOT permit children under D Excessive temperatures have a high the age of 16 to use this steambath potential for causing fetal damage dur 3 Ga hotand cincaie ing the earl
3. BLUE BLACK o GREEN WHT BLUE FEED SOLENOID GROUND RED WHT RED E ILE fll p CONTACTOR o AutoFlush o PURPLE 2 oo SteamGenie or lolo iGenie optional ssj iSteam iTempo TO PROBE or iTempo Plus HEATING ELEMENT CONTROL BOARD a4 Control POWER INPUT L1 12 L3 G I TRANSFORMER BLACK ol BLUE BLACK o GREEN 5 WHT BLUE WATER gt FEED SOLENOID GROUND VALVE o y RED 6 WHT GRAY WHT RED CONTACTOR Ty I ll om o AutoFlush o optional PURPLE n olo SteamGenie or ofo iGenie optional HEATING ELEMENT Fay iSteam iTempo TO PROBE 050 or iTempo Plus CONTROL BOARD Control 10 mr steam Installation Operation amp Maintenance Manual INSTALLATION INSTRUCTIONS FOR MODELS MS SUPER 4E MS SUPER 5E AND MS SUPER 6E 1 Install each unit as in a single installation Install the two generators as close to each other as possible 2 ANUZEIJ Shock Hazard Power must be disconnected at the main electrical supply before removing steam generator covers 3 Connect the iSteam or iTempo Plus control to either generator per the control instructions 4 Remove one knock out on each generator as shown Insert the ends of interconnecting cable provided PN 103904 through the knock outs as shown in the Diagram on page 5 Connect each end to the printed circuit board as shown 5 Connect separate plumbing and power supplies for each unit Wiring
4. w Steam will shut off automatically when control counts down to zero To shut steam off manually turn control OFF To clear steam from enclosure area turn shower on before opening door If unit does not start and control does not turn ON control display does not light up then turn breaker off for 20 seconds and try again 1 Check all internal and external plumbing fittings for leaks while the steam is on OPTIONAL amp ACCESSORY EQUIPMENT Refer to specific instruction manual for installation operation and maintenance of optional equipment and accessories such as iSteam iTempo Plus iTempo Home Wizard iGenie and MSTS TROUBLESHOOTING AVIS All electrical troubleshooting to be performed by a qualified licensed electrician Step 1 Check main incoming power to the unit Step 2 Verify the transformer is receiving 208 240 VAC Step 3 Verify that you have 24VAC coming out of the transformer WHT amp WHT BLU wires into the board Step 4 Verify that you have the green light on the PC board Contactor Water Feed lt Solenoid Step 5 Push the white test button to run the generator for 10 minute test cycle Make sure the steam room is empty Step 6 Verify that you have 24 VAC bevel Probe m gt to the water feed solenoid GRY amp Cn uai ao 7 Ste WHT GRY wires will fill when needed i Water Fee Power Supply Knock Out AutoFlush and Play Connectic
5. 6 Steam Head Installation 0 0 ce eee ee eee 7 Steam Generator Dimensions 000 8 Electrical Specifications amp Field Power Wiring 9 Wiring Diagrams 0 0 0 0 eee 10 11 Optional Tandem Cable Diagram 11 Initial Start Up amp Checkout 0 00000000 12 Optional amp Accessary Equipment 1 111 12 Troubleshooting lesse 12 System Status Codes illis eee eee 13 Liquid Level Control Board 0 00 000 13 Optional AutoFlush System 1 41 11 14 Optional Drip Pati ss sest zowie adw 440 15 Optional Express Steam aay iden d sae big Xa riche aaia 15 Parts Identification Diagrams 00000 ee eae 16 Replacement Parts List scis cesses n 17 CONTROL INSTALLATION Betore Installingi i nsi 24024000444 aaa PGA 18 ControlRoughslhis eu ace 6204092 AQ Ri eyes 18 HOMEOWNER SECTION Important Safety Instructions ien c xe ORO 19 Setting Steam Bath Temperature amp Duration 20 Safety amp Operating Info 44 sos o hee 20 Care Tips for Controls and Generator Maintenance 20 Using the AromaSteam Essential Oils 21 MWattanty iste deeds osa qe ple e are GR aerea 21 mr steam Feel Good Inc mr steam Installation Operation amp Maintenance Manual SELECT YOUR MR STEAM Mr Steam Your Fingertips Start working smarter with Mr Steam s mobile sizin
6. IMPORTANT NOTE The control cable should be run in a dedicated 1 conduit to facilitate installation and service VAA WARNING DO NOT route iSteam iTempo Plus iTempo HomeWizard or iGenie control wiring inside conduit together with power lines or close to hot water or steam piping Doing so may result in an inoperative or hazardous installation Items 1 4 1 DO NOT install steambath generator inside steam room a shock hazard will occur 2 DO NOT install steambath generator outdoors or wherever environmental conditions may result in a shock hazard or affect performance of the generator 3 To prevent damage to the steam generator or a fire hazard DO NOT install steambath generator near flam mable or corrosive materials or chemicals such as gaso line paint thinners or the like Installation in areas hav ing high concentrations of chlorine such as pool equipment room must be avoided 4 Burn Hazard Steam line safety valve drain valve and plumbing become hot during operation and remain hot after shutdown for a period of time Provide appro priate protection including insulating plumbing lines Avoid plumbing runs and steamhead locations that can come in contact with bathers AH Items 5 7 5 DO NOT install steambath generator or plumbing lines in unheated attic or any locations where water could freeze and cause pipes to rupture and cause property damage 6 Install steambath generator on a solid and level sur face Ke
7. basic safety precautions should always be followed including the following IMPORTANT SAFETY INSTRUCTIONS 1 READ AND FOLLOW ALL INSTRUCTIONS 2 DO NOT permit children under D Excessive temperatures have a high the age of 16 to use this steambath 3 Steam is hot and can cause injury or death if improperly used Steam rooms contain steam and elevated tempera tures Please read and observe all warnings in this manual before installing or using a steam room 4 To reduce the risk of injury A The wet surfaces of steam enclosures may be slippery Use care when entering or leaving B The steam head is hot DO NOT touch the steam head and avoid the steam near the steam head C Prolonged use of the steam system can raise excessively the internal human body tempera ture and impair the body s ability to regulate its internal temperature hyperthermia Limit your use of steam to 10 15 minutes until you are certain of your body s reaction The peel and stick warning label located in this manual is an essential part of providing a safe envi ronment for steam room users The peel and stick warning label must be applied to the wall of the shower or steam enclosure at a point that is visible to all users Failure to install this sticker may result in serious injury or death WHICH IS KEPT potential for causing fetal damage during the early months of pregnancy Pregnancy or possibly pregnant women should consult a
8. Control Board MS REGULAR MODELS MS65E MS400E Liquid Level Probe with AutoFlush Power Supply E Knock Out shown with cover removed Transformer Water Feed Solenoid oo Water Inlet Plug and Play Connection see page 13 _ Steam Outlet Access Cover f NOTE FOR ILLUSTRATIVE PURPOSES ONLY Some components may be omitted or altered for clarity DO NOT use for wiring repair or other purposes not related to component identification 7 AutoFlush Express Steam 3 E Heater optional Heating Element optional Stainless Steel Tank i Nipple Manual not included Drain Valve MS SUPER MODELS MS SUPER 1E MS SUPER 6E with AutoFlush Power Block shown with cover removed eo Fuses EM Liquid Level Control Board Contactor 7 Transformer Liquid Level Probe Ip 4 Water Feed i Solenoid NOTE Super 1E 240 1 Power Supply Knock Out models are not supplied with internal fusing Water Inlet TRS Plug and Play Connection see page 13 Element Access Cover NOTE FOR ILLUSTRATIVE PURPOSES ONLY Some components may be omitted or altered for clarity DO NOT use for wiring repair or other purposes not related to component identification Express Steam heater optional C LIE AutoFlush lve Val optional Heating Element Stainless Steel Tank
9. Transformer Water Feed Power supply SAATI ALL eA MM Solenoid Field _ Wiring 7 Models MS single phase wiring shown Water Feed AutoFlush Plug and Play Connection see page 14 Steam Outlet Super 1E 6E 9 mr steam Installation Operation amp Maintenance Manual SINGLE PHASE 208 240 VOLT WIRING DIAGRAMS MODELS MS90E MS150E MS225E MS400E MODELS MS SUPER 1E MS SUPER 2E MS SUPER 3E Note Super 1E 240V does not have fuses POWER INPUT L2 THREE PHASE 208 240 VOLT WIRING DIAGRAM MODELS MS90E MS150E MS225E MS400E MS SUPER 1E MS SUPER 2E MS SUPER 3E L1 G p TRANSFORMER LEGEND ingens BLACK oL BLUE FIELD WIRING FACTORY BLACK WIRING GREEN GRAY WHT BLUE FEED SOLENOID GROUND VALVE RED E WHT RED niiet o CONTACTOR E ILL BB J tl p 0 AutoFlush o SURAE a oa occa 2 o o SteamGenie or ojoj iGenie optional cmm iSteam iTempo HEATING ELEMENT TO PROBE Mog or iTempo Plus CONTROL BOARD Control POWER INPUT L1 L2 G RNC TT TT TRANSFORMER BLACK o
10. as required for moisture seal ZSEE 4 End of pipe to he recessed 1 4 without Acrylic Shield Oil Well 1 8 with Acrylic Shield STEP 3 Drop Ear Fitting STEP 4 Steamhead shown with optional acrylic shield Locating Nipple All drawings are for illustrative purposes only mr steam GENERATOR DIAGRAM 17 IMPORTANT NOTES Provide a minimum of 12 inches at both ends and top of the steam generator or as required for servicing Alternately provide unions as required to facilitate installation and dis connection of the steam generator The minimum clearance from combustible surfaces is zero all around _ Side View Showing 7 Element Access Panel TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLY TO ELEMENTS All drawings are for illustrative purposes only Installation Operation amp Maintenance Manual Water Inlet Control amp Accessory Connections MS 90E MS 400E MS Super 1E 3E A 5 127 7A 184 B 8 206 976 251 C 11 392 15 394 D 14 392 1844 476 E 1 48 1 32 Fj 2 51 24 57 G 5 149 6 152 H 5 127 4 124 6 175 7 200 J 2 51 2 51 K 14 368 17 432 L 2 64 25 64 M 6 162 6 162 NOTES 1 M Optional AutoFlush 2 All units in inches MM 3
11. flushing Poor water quality can affect efficiency or result in steam gen out accumulated materials salts and other particles erator damage Water contains impurities in solution and sus which are natural by products of boiling water pension These impurities concentrate in the generator The concentration of these impurities increases as more feedwater is introduced into the generator and steam is produced If the suspended solids are allowed to concentrate beyond certain limits a deposit or scale will form on the generator internal surfaces This deposit can interfere with the proper generator operation and cause generator failure The concentration of these impurities is generally controlled by the water quality and by periodic draining of the generator LOCATING THE STEAM GENERATOR Select a location as near as practical to the steam room The optional AutoFlush System feature automatically drains the Mr Steam generator following each use A time delay allows the water to cool down about two hours before it drains by gravity for a safe and gentle operation Typical locations include closet vanity cabinet heated attic or basement NOTE The standard length of the cable for connecting the control to the steam generator is 30 feet The steam generator and control must be located accordingly A 60 foot cable is available as a special order part for eTempo and iTempo PN 103990 60 for iTempo and PN 104117 60 for iSteam
12. information AROMASTEAM If the optional AromaSteam Electronic Oil Delivery System PN MS AROMA is to be installed a 90 degree T plumbing fitting must be installed at a designated location on the steam outlet line See the Mr Steam AromaSteam Operation and Instruction Manual PN 100402 for installation information before the steam line is installed at the technical downloads section of www mrsteam com mr steam INSTALLING THE ROUND OR SQUARE AROMASTEAM STEAMHEAD 12 NPT NOTE A 1 clearance hole around the steam pipe is needed to mount the steamhead STEP 1 Locate steam head 6 12 inches above floor except for 1 Tub shower enclosures install 6 inches above tub top edge 2 For enclosures with acrylic or other non heat resistant flooring install Acrylic Shield Part Number MS 103938 STEP 2 Install steamhead with the oil well facing up as shown Hand tightening is sufficient when teflon or equal pipe thread sealing compound is used STEP 3 Secure a bronze drop ear fitting to a header and run a A copper steam line from the steam generator to the drop ear fitting Install a temporary nipple 6 or longer in the drop ear fitting to locate the steamhead after the wall is finished STEP 4 After the wall has been finished mark on the nipple where the surface of the wall is Remove the nipple and measure the portion that was in the wall the end to your mark Subtract 4 from that dimension and select a brass nipple
13. of that length to finish the installation STEP 5 Wrap teflon tape around the threads of the new nipple and screw the nipple into the steamhead Do not use wrenches or tools which would damage the steamhead s finish Wrap teflon tape around the threads of the nipple and screw the nipple and steamhead assembly you just made into the drop ear fitting in the wall The steamhead should be flush with the wall and the well must be facing up IMPORTANT NOTE DO NOT disassemble steamhead Mr Steam s steamhead is shipped fully assembled and requires no additional assembly To preserve steam head finish DO NOT use wrench or other tools to tighten DO NOT use abrasive cleansers or chemicals Use only water with mild soap and a non abrasive sponge Because the steam head and direct steam emissions are very hot locate the steam head where incidental contact by bather with the steam head or direct steam emis sion cannot occur Consult with supplier of acrylic fiberglass and other non heat resistant enclosures for recommended steamhead location Use Acrylic Shield PN MS 103938 round or PN MS 1039385Q square See instructions provided with steam shield Installation Operation amp Maintenance Manual 1 8 minimum clearance required when Acrylic Shield is used See installation instructions provided with the Acrylic Shield Ec Use Teflon or equal sealant on pipe threads Apply with silicone or equal sealant
14. will de energize when the steam room reaches steambathing temperature resulting in a more gentle and energy efficient operation All drawings are for illustrative purposes only mr steanr Installation Operation amp Maintenance Manual INSTALLATION PLUMBING All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable National and local codes 1 Use unions on all pipe connections 2 Use only brass piping or copper tubing as permitted by codes 3 DO NOT use black galvanized PVC pipe or PEX WATER SUPPLY 3 8 NPT 1 Connect to cold water line 2 Provide a shut off valve in the water supply line upstream of the steambath generator 3 DO NOT overheat inlet solenoid valve with solder connections Overheating will damage parts 4 Flush inlet water line thoroughly before making connection to unit 5 Strainer recommended upstream of feed water connection 6 For best performance water pressure should be 15 to 20 psig Reduce pressure as required 7 Provide anti water hammer device as required 8 Install an approved backflow preventer as required by local codes DRAIN 12 NPT AZNUIEM The drain from the generator should not share an undersink trap unless the generator is mounted higher than the sink to prevent damage to the generator if the drain backs up NOTE A drain valve is provided to facilitate servicing Provide a drain line connection from steambath generator drain valve a
15. CAN BE DANGEROUS AND CAN RESULT IN INJURY THROUGH SLIP AND FALL OR OTHERWISE mr steam 43 20 34 ong Island City NY 1 6 STEAM www mrsteam ou PURI0DQT8 7 18 mr steanmr OSETTING THE STEAM BATH TEMPERATURE AND DURATION Set the steam bathing temperature according to personal preference however it is highly rec ommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels Set duration to a maximum of 10 minutes to gauge comfort and safety levels This will allow the steam generator to heat up and begin producing steam SAFETY AND OPERATING INFORMATION DO NOT install or use any iSteam iTempo Plus iTempo HomeWizard or iGenie controls without reading and understanding the Mr Steam steam generator Installation and Operation Manual Failure to read and understand these instructions may result in an inoperative or hazardous installation The peel and stick warning sticker located in this manual must be read and permanently affixed in a conspicuous location near the steam room Failure to read and affix this warning sticker in a conspicuous location may result in serious injury or death If an iSteam iTempo or iTempo Plus control is installed outside the steam room a Remote Temperature Probe PN MSTS or iMSTS must be installed inside the steam room per installation instructions supplied with the Remote Temperature Probe Failure to install according to instructions will result in an inop
16. Diagram MS Super 4E MS Super 5E MS Super 6E LEGEND lDiogans WIRING PRIMARY UNIT SECONDARY UNIT WIRING POWER INPUT POWER INPUT L1 L2 up SE TRANSFORMER TRANSFORMER BLACK BLUE AutoFlush AutoFlush Crona CONTACTOR optional PURPLE Tempon ro Not onnect fay iSteam or TO PROBE Control iTempo Plus HEATING ELEMENT CONTROL BOARD OPTIONAL TANDEM CABLE For connecting more than 2 steam generators in tandem POWER INPUT PRIMARY UNIT POWER INPUT SECOND UNIT TRANSFORMER BLACK B TRANSFORMER BLUE BLACK TO FIFTH UNIT TO FOURTH UNIT TO THIRD UNIT d ee AutoFlush optional Steam Genie optional TO PROBE ES iSteam or HEATING ELEMENT CONTROL BOARD ilempo Plus e Optional Tandem Cable for 2 5 Generators TOMASTER UNI length is 30 ft PN 10391 AutoFlush CONTACTOR optional PURPLE TO PROBE HEATING ELEMENT CONTROL BOARD INSTALLER mr steam Installation Operation amp Maintenance Manual INITIAL START UP AND CHECKOUT 1 Turn on control Follow specific instructions provided with controls 2 Steam will begin to appear in approximately 5 minutes unless equipped with factory installed Express Steam option at the steam head Steam will shut off when desired temperature is reached and will automatically resume when room temperature drops below set point
17. E 29071CMS Heating Element 7 5 KW 240V MS 225E 29091BMS Heating Element 9 KW 208V MS 400E 29091CMS Heating Element 9 KW 240V MS 400E 29101BMS Heating Element 10 KW 208V MS SUPER 1E amp MS Super 4E 29101CMS Heating Element 10 KW 240V MS SUPER 1E amp MS Super 4E 29121BMS Heating Element 12 KW 208V MS SUPER 2E amp MS Super 5E 29121CMS Heating Element 12 KW 240V MS SUPER 2E amp MS Super 5E 29151BMS Heating Element 15 KW 208V MS SUPER 3E amp MS Super 6E 29151CMS Heating Element 15 KW 240V MS SUPER 3E amp MS Super 6E 104058 iGenie All Models 104059 iGenie Interface Module All Models 104060 iGenie Interface Cable 5 ft All Models mr steamr CONTROL INSTALLATION Installation Operation amp Maintenance Manual Refer to Control Manual for specific installation requirements BEFORE INSTALLING Turn power to the steam generator OFF before connecting the control to the generator Failure to turn the power off will result in an inoperable control To avoid unintentional steambath operation DO NOT locate the control where other controls acces sories shower heads valves body sprays or similar within the shower could cause confusion or interfere with the Mr Steam control s intended use and function DO NOT use any iSteam iTempo Plus iTempo HomeWizard or iGenie controls without reading and understanding its own manual and the Mr Steam steam generator Installation and Operation Manual Failure to read and understa
18. ICAL INSTALLATION INSTRUCTIONS FOR MODELS MS SUPER 4E 5E amp 6E shown with optional AutoFlush Printed Circuit Board Component shown enlarged for illustrative purpose 1 Install each steam generator as in a single installation Install genera tors as close as practical to each other not exceeding 10 feet The interconnecting cable length is 12 feet 2 ANZELM Shock Hazard Power must be disconnect ed at the main electrical supply Remove steam gen erator covers Retain screws and covers for reuse iSteam or iTempo Plus Control Power Suppl d pply Interconnecting 3 Connect the iSteam or iTempo Plus control to J Cable PN 103904 either unit as per the Installation Manual supplied with each control 4 Remove one knock out on each generator as shown Insert the ends of interconnecting cable provided PN 103904 through the knock outs as shown in diagram Connect each end to the printed circuit board connector labeled TANDEM as shown 5 Prevent the interconnecting cable from contacting hot surfaces such as steam outlet safety valve and the like 6 Connect separate plumbing and power supplies for each unit Replace covers with cover screws Steam Heads shown with optional acrylic shields 7 Provide unions as required to facilitate installation and disconnection of piping Secondary Unit Optional AutoFlush see AutoFlush Installation page 13 NOTE The secondary unit
19. IMPORTANT NOTES This document contains important safety operation and maintenance information Leave this document with the homeowner Do not dis card this document The following general information should be used in conjunction with consultations with an architect designer and contractor in determin ing factors necessary in providing a suitable and safe steam room Mr Steam steam generators are intended to be operated with Mr Steam iSteam iTempo Plus iTempo Home Wizard and iGeniee controls only and are to be installed strictly in accordance with the specific instructions contained in this manual and as supplied in the manuals provided with the controls or accessories 3 mr steam WATER QUALITY INFORMATION For optimum results the water supply should be tested prior to installation If the mineral content exceeds the following recommended limits various external treatment processes are recommended to correct the problem NOTE An analysis of the on site water must be made by a recognized and reliable water treatment company to ascertain the existing condition and treatment required Installation Operation amp Maintenance Manual RECOMMENDED FEEDWATER QUALITY Hardness ppm 8 85 0 5 5 gpg P Alkalinity ppm 85 410 5 24 gpg T Alkalinity pom 200 500 7 0 gpg pH strength of alkalinity 8 0 11 4 Every 2 months or more often in hard water areas the manual drain valve should be opened fully
20. MS Super 4E includes 2 MS Super 1E units 4 MS Super 5E includes 2 MS Super 2E units 5 MS Super 6E includes 2 MS Super 3E units WATER INLET 36 NPT STEAM OUTLET 14 NPT SAFETY VALVE 3 NPT MANUAL DRAIN VALVE 14 NPT AUTOFLUSH VALVE 14 NPT mr steamr Installation Operation amp Maintenance Manual ELECTRICAL CHART ELECTRICAL Vol Max Room Wire Size Wire Size Model No Cu Ft KW Volts Phase Amps AWGfor 40 C AWG for 45 C Ambient Ambient ANIZEDMIE All electrical wiring to be installed by 208 24 10 8 a qualified licensed electrician in accordance with MS 90E 100 5 0 3 14 12 12 National Electrical Code and local electrical code 240 i A 3 4 208 29 8 8 POWER WIRING MS 150E 150 60 3 17 10 10 See Field Power Wiring Diagrams below 240 25 8 8 3 14 12 2 1 Check power voltage Use 240V rated unit when supply xm gt A gt is greater than 208V Most homes have 240V 1PH MS 225E 225 75 3 21 10 10 service Use 208V rated unit for 208V power 240 32 8 8 2 Use minimum 90 C 300V rated insulated copper A gt gt conductors only sized in accordance with National MS 400E 360 90 3 25 8 8 Electrical Code and local electrical code for the current 240 38 8 8 in Ampere Chart If allowed by codes NM cable may 3 22 10 0 require a larger wire size than as listed on the chart 208 49 6 6 PM MS Super 475 0 0 3 28 8 8 3 Connect suitably sized equipment g
21. Nipple Manual not included Drain Valve mr steam Installation Operation amp Maintenance Manual REPLACEMENT PARTS LIST Part No Description Generator 99178MS Drain Valve All Models 99297 Safety Valve 15PSI All Models 100479 Water Feed Solenoid Valve w filter All Models 10477 3 Transformer 24VAC All Models 103975 Liquid Level Control Board All Models 103904 Tandem Cable for 2 generators 12 ft All Models 103917 Tandem Cable for up to 5 generators 30 ft All Models 103990 30 Cable for iTempo Control 30 ft All Models 103990 60 Cable for iTempo Control 60 ft All Models 104117 30 Cable for iSteam 30 ft All Models 104117 60 Cable for iSteam 60 ft All models MSTS Remote Temperature Probe for iTempo Plus All Models iMSTS Remote Temperature probe for iSteam All Models 100476 2 Contactor 50A 2 pole MS 90E 400E Single phase 99012 Contactor 50A 3 pole All 3 Phase Models 103453 Contactor 50A 4 pole MS Super 1E Super 6E 100471 2 Probe Assembly All Models 99096MS Heating Element Gasket All Models 103938 Round Acrylic Shield iTempo amp iTempo Plus All Models 103938 Square Acrylic Shield iTempo amp iTempo Plus All Models 99314 Power Fuse 60A 250V MS Super 1E 6E Single phase 29051BMS Heating Element 5 KW 208V MS 90E 29051CMS Heating Element 5 KW 240V MS 90E 29061BMS Heating Element 6 KW 208V MS 150E 29061CMS Heating Element 6 KW 240V MS 150E 29071BMS Heating Element 7 5 KW 208V MS 225
22. amage If there is not enough room for the valve an elbow and a short nipple not provided can be added 3 Open Drain Valve handle must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown ANUZEDMEJ DO NOT drain into a steam enclosure or any location where accidental contact with drain water may occur In the event of a power failure the AutoFlush System valve will open and may dis charge boiling water causing a scalding hazard SWEAT FITTINGS When using sweat fittings use only tin base solder with a melting point below 600 degrees F DO NOT overheat Ends of water supply tubing must be thoroughly clean for a minimum distance of 1 from ends DO NOT remove valve cover TO CHECK OPERATION 1 Turn on Mr Steam and allow tank to fill with water 2 Turn off Mr Steam control Water should stay in tank 3 Turn off power at the panel box Water should discharge from tank 4 Turn on power at panel box 5 Repeat PROVIDE DRAIN PLUMBING ACCORDING TO LOCAL CODES PLUMB AS REQUIRED FOR AUTOFLUSH SYSTEM Steam Generator 3 Pin Connector for AutoFlush TEM AutoFlush Cord Connector AutoFlush Cord Nipple copper or brass nipple NPT x 3 or longer not supplied AutoFlush J Valve Drain Valve Yo Plumb to shown in the correct Pio 4 Drain Line open position End nd DO NOT REMOVE A ug THIS DRAIN VALVE Arrow indicate
23. ccording to National and local Codes Check local plumbing code for receptor trap and vent requirements Do not connect Drain line and Safety Valve line together Unit drains by gravity DO NOT connect the drain valve to the steam line STEAM OUTLET NPT 1 DO NOT install any valve in steam line Flow of steam must be unobstructed 2 Use 1 2 inch brass pipe or copper tubing from unit to steam head as permitted by codes 3 Insulate steam line using pipe insulation rated 212 F or higher 4 Pitch steam line 1 4 per foot towards steam head or steam generator to avoid valleys and trapping of condensate NOTE Running the steam line down and then up will create a steam trap blocking the flow of steam NOTE A 1 5 hole in the steam room is required to mount the steamhead SAFETY VALVE 34 NPT Where permitted by local codes provide an outlet plumbing connection for safety valve ANZELM To insure proper and automatic safety valve operation DO NOT connect a shut off valve or a plug at safety valve outlet DO NOT connect a shut off valve or any obstruction in steam supply pipe DO NOT connect the safety valve output into the steam line DRIP PAN Mr Steam strongly recommends the use of a drip pan in the unlikely event of a plumbing leak Check local plumbing codes for receptor trap and vent requirements Drip pans drain by gravity The drip pan is equipped with an integral 3 4 fitting See page 15 for additional drip pan installation
24. ctrical Code for other types of conductors See Mr Steam Installation and Operation Manual for complete dimensional and installation information Dimensions are for generator only without AutoFlush or plumbing features Shipping weight and pricing are for generator only without control or steamhead Tt Water usage based on 20 minutes of operation MS SUPER 4E includes two MS SUPER 1E steam generators and require one iTempo Plus Control and two matching steamheads MS SUPER 5E includes two MS SUPER 2E steam generators and require one ilempo Plus Control and two matching steamheads MS SUPER 6E includes two MS SUPER 3E steam generators and require one iTempo Plus Control and two matching steamheads mr steam BEFORE INSTALLING Carefully inspect the Steam Generator and packaging for shipping damage In the event of shipping damage please contact the carrier for claim information Our customer service department can assist you with any missing or damaged parts Read these instructions before installation or service Although this MS steambath generator has been fully qualified for shipment by Mr Steame the following must be reviewed for proper safe and enjoyable steam bathing 1 Verify that the model and accessories specifications are correct for the incoming line voltage 2 Insure steambath generator has been correctly sized for Installation Operation amp Maintenance Manual the steambath room Pay par
25. erative control and overheating of the steam room To prevent slip and fall hazards non skip strips must be installed on the steam room floor DO NOT alter or modify any Mr Steam product Doing so may result in an inoperative or hazardous installation and will void the UL listing and warranty IMPORTANT NOTES Malfunction due to power spikes lightning fire freezing or flooding is not covered under the warranty Discontinue use of the steam generator or control if the steam generator is damaged or otherwise not functioning properly Doing so may result in an inoperative or hazardous condition 20 Installation Operation amp Maintenance Manual CARE TIPS FOR ALL CONTROLS AND STEAMHEADS 1 Use only mild soap and water on a soft cloth to clean the control and steamhead 2 DO NOT use abrasive cleansers 3 If the decorative cover is damaged on the iTempo or iTempo Plus call Mr Steam technical service for replacement parts NOTE Replacement of the decorative covers requires removal and reinstallation of the control from the mounting surfaces STEAM GENERATOR MAINTENANCE Mr Steam steambath generators require little maintenance Other than periodic draining maintenance procedures are mini mal Every 2 months or more often in hard water areas the manual drain valve should be opened fully flushing out accumu lated materials salts and other particles which are natural by products of boiling water NANN Fl
26. ewood CA 90301 TEL 1 800 76 STEAM Fax 718 472 3256 TEL 1 800 72 STEAM rax 310 216 2944 2014 Sussman Automatic Corporation Mr Steam and des AromaFlo AutoFlush AutoSteam Butler Package ChromaSteam Clean Steam Every Time Club Therapy Digital 1 Express Steam From Bathroom to Spa iGenie iSizing iSteam iSteam Plus Making Wellness a Way of Life MusicTherapy Spa Package Steam Genie Steam on Demand Steam Home iTempo iTempo Plus SteamTherapy Sussman Valet Package Virtual Spa System Voice Genie and Voice Wizard are registered trademarks of Sussman Automatic Corporation AudioWizard A Lifetime of Pleasure Home Wizard iButler iSteamTV iTempo iTempo Plus MySteam Smart Sizing Steam in a Box SteamStart SteamStop The Intelligent Steambath are trademarks of Sussman Automatic Corporation PUR 100472A 12 14
27. g app now available for the iPade iPode and most smart phones Visit mrsteam com to size your generator automatically or go directly to http isizing mrsteam com Materials of construction room size and special design features such as large glass areas all affect the steam generator model selection 1 Measure length width amp height in feet of the steam shower or tub shower Multiply the Length x Width x Height__ ROOM VOLUME 2 Construction Materials For natural stones natural marble Add 110 stone shale glass block or concrete For ceramic or porcelain tile on Add 40 cement board or mortar bed 3 Ceiling Height For each foot above 8 feet Add 15 4 Add all figures above to obtain the Total Room Volume required Compare your Room Volume to the Chart below and select the appropriate model ANZELM in considering the purchase or use of this steambath system please note that if you are pregnant have a coronary condition are in poor health are being treated for any other medical condition or are using medication or drugs Mr Steam recommends that you obtain the approval of a physician before use For information about this product and safety issues please call 1 800 76 STEAM IMPORTANT NOTES For steam rooms constructed of acrylic or synthetic materials select next lower rated MS model The Mr Steam Sizing Chart allows for up to 60 feet of insulated steam line from the MS genera tor to
28. green light on liquid level control board will be off Incorrect voltage supplied to Generator Supply steam generator with the correct voltage noted on the data plate label Err2 Button on control is pressed for more than 5 minutes Control cover misalignment Remove and reinstall control cover Debris behind control cover Remove control cover and clean cover control and keypad with a damp cloth Errb Water level not satisfied in a tandem set up Check secondary generators see H20 Err7 Liquid Level Control Board malfunction Memory error in LLCB Press ON OFF to clear Replace control if code remains LIQUID LEVEL CONTROL BOARD Explanation of LED Indicators GREEN LED is ON when there is 208 240 Volt incoming power connected 24 Volt transformer secondary output and on board 5 Volt DC control power are present YELLOW Water level indicator LED is OFF when no water is detected for more that 5 seconds ON when water level is satisfactory For units with AutoFlush if more than five hours have elapsed since last usage and this LED is ON it is indicative of an AutoFlush or water level probe circuit malfunction RED Contactor relay indicator LED is ON when relay is closed and sending 24 Volts to the contactor coil This LED comes ON if the generator is ON FORCE ON Press this button to operate the generator This button is for trouble shooting only and will operate TEST BUTTON if a control is co
29. he control in a location representative of the desired steambathing temper atures Do not locate the control above or near the steam head or direct steam emissions NOTE Drawings for illustrative purposes only L Consult with qualified designer architect or contractor for steam room construction details L Provide unions as required to facilitate installation and disconnect of piping le L Control cable run in 1 conduit located behind the wall i LL E l ENS WECNMES m Field installed o a gt Field installed water supply line CH ee tL vr eel ee power supply v eit FE Mis l J gt Ls JJ LJ L J eed La J ed Steam Head shown with optional acrylic shield See page 7 for Steam Head Installation information J EN Drain Valve must be closed when the optional AutoFlush is not installed pc Field installed 7 steam supply pipe NEXT To avoid unintentional steambath operation do not locate the control When installing the optional AromaSteam install a down where other controls accessories shower heads valves body sprays or similar within the ward facing 90 degree T in the steam supply line See the shower could cause confusion or interfere with the Mr Steam control s intended use and function AromaSteam Installation Manual for complete information TYP
30. ia include an increase in the internal temperature of the body dizziness lethargy drowsiness and fainting The effects of hyperthermia include c Unawareness of impending risk d Fetal damage in pregnant women e Physical inability to exit the steambath and f Unconsciousness NAANA The use of alcohol drugs or medication can greatly increase the risk of hyperthermia 43 20 34th Street Long Island City NY 11101 TEL 1 800 76 STEAM Fax 718 472 3256 LISTED mr steame Sussman Automatic Corporation hello mrsteam com www mrsteam com Up NOM C 9410 S La Cienega Blvd Inglewood CA 90301 TEL 1 800 72 STEAM rax 310 216 2944 PUR 100472A Rev 12 14 RESIDENTIAL STEAMBATH GENERATOR SYSTEMS MODEL INSTALLATION OPERATION amp MAINTENANCE MANUAL MODELS MS 90E MS 150E MS 225E MS 400E MS SUPER 1E SERIAL NO MS SUPER 2b MS SUPER 3E MS SUPER 4E MS SUPER 5E MS SUPER 6E TABLE OF CONTENTS Important Safety Instructions Inside front cover Select Your Mr Steam Model 41 11 2 Generator Specification Chart 0000 2 INSTALLER SECTION Before Installing sce 3 Steam Room Guidelines orze as wa e ears 3 Water Quality Information l l eese 4 Locating the Steam Generator 1111111 4 Typical Installation Instructions 4x2 xc ace eas RR n 5 Installation Plumbing Water Supply Drain Steam Outlet Safety Valve Drip Pan AromaSteam
31. k the suitability of any materials with the manufacturer Walls and ceilings must be constructed of water resistant non corrosive surface such as tile marble molded acrylic or other non porous material 5 The ceiling should be sloped to prevent dripping of condensate 6 Provide a floor drain 7 No heating venting or air conditioning devices should be installed inside the steam room 8 Steam room tile construction information is available from the Tile Council of America Inc by purchasing the TCA Handbook for Ceramic Tile Installation Tel 864 646 8453 or www tileusa com 9 Windows that are part of the steam room should be double paned and tempered safety glass 10 Limit steam room ceiling height to 8 feet Exceeding 8 feet may require a higher rated steam generator NUZGININS Never use damaged equipment doing so may result in an inoperative or hazardous installation Discontinue use of the steam generator and control if the steam generator or control are damaged or otherwise not functioning properly Doing so may result in an inoperative or hazardous installation ELECTRICAL SHOCK HAZARD Mr Steam steam generators are connected to 240V line voltage and contain live electrical components All installation and service to be performed by qualified and licensed electricians and plumbers only Installation or service by unqualified persons or failure to use Mr Steam parts may result in property damage or in a ha
32. ll result in an inoperable control 2 DO NOT operate iSteam iTempo Plus iTempo HomeWizard or iGenie controls with other than a Mr Steam iSteam or iTempo compatible steam generator Mr Steam residential steam generators with serial num bers lower than 900000 or any other brand of steam generator are not to be operated with iTempo controls Doing so may result in an inoperative or hazardous instal lation If iSteam is used with a generator having serial number 900000 through 930030 contact Mr Steam tech nical support for an upgraded PC board This document contains important safety operation and maintenance information Leave this document with the homeowner Do not discard this document 4 Discontinue use of the steam generator or control if the steam generator is damaged or otherwise not function ing properly Operating a damaged steam generator may result in an inoperative or hazardous installation Refer to Installation Instructions for the specific control IMPORTANT NOTE The control cable should be run in a dedicated 1 conduit to facilitate installation and service 1 Determine the desired installation location of the con trol The iSteam iTempo and iTempo Plus controls are designed to be installed inside or outside the steam room as a matter of personal preference If the control is in stalled inside the steam room the control must be located 2 4 5 feet above the floor near the bather seating area 3 The c
33. n is important for the safe and efficient installation and operation of this generator These are types of potential hazards that may occur during installation and operation PAA WARNING Indicates a potentially hazardous situation which if not avoid ed could result in death or serious injury NANN indicates a potentially hazardous situation which if not avoid ed may result in minor or moderate injury or product damage IMPORTANT NOTE This highlights information that is especially relevant to a problem free installation All information in these instructions is based on the latest product information available at the time of publication Sussman Automatic Corporation reserves the right to make changes at any time without notice HYPERTHERMIA occurs when the inter nal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 F The symp toms of hyperthermia include an increase in the internal temperature of the body dizziness lethargy drowsiness and faint ing The effects of hyperthermia include a Failure to perceive heat b Failure to recognize the need to exit the steambath c Unawareness of impending risk d e and Fetal damage in pregnant women Physical inability to exit the steambath f Unconsciousness NLSN The use of alcohol drugs or medication can greatly increase the risk of hyperthermia When using this steam bath equipment
34. nd these instructions may result in an inopera tive or hazardous installation ANZEMIJ A peel and stick warning sticker must be read and permanently affixed in a conspicuous location near the steam room Failure to read and affix this warning sticker in a conspicuous location may result in serious injury or death Install the iSteam iTempo or iTempo Plus controls according to installation instructions Failure to install according to instructions will result in an inoperative control or hazardous overheating or inadequate heating of the steam room If an iSteam iTempo or iTempo Plus control is installed out side the steam room a Remote Temperature Probe PN MSTS or iMSTS must be installed inside the steam room per instal lation instructions supplied with the Remote Temperature Probe Failure to install according to instructions will result in an inoperative control and overheating of the steam room CONTROL ROUGH IN DO NOT route iSteam iTempo Plus iTempo HomeWizard or iGenie control wiring inside conduit together with power lines or close to hot water or steam piping Doing so may result in an inoperative or hazardous installation DO NOT alter or modify any Mr Steam product Doing so may result in an inoperative or hazardous installation and will void the UL listing and warranty IMPORTANT NOTES 1 Turn power to the steam generator OFF before connect ing the control to the generator Failure to turn the power off wi
35. nnected or not Pressing the button again will shut the generator OFF The test button will only allow the generator to operate for 10 minutes Liquid Level Control Board PN 103975 shown without wiring All drawings are for illustrative purposes only Force On Test Button mr steam Installation Operation amp Maintenance Manual OPTIONAL AUTOFLUSH Box Contents AutoFlush Valve with Cord Installation Instructions OPERATION The optional AutoFlush System feature automatically drains the Mr Steam generator following each use A time delay allows the water to cool down about two hours before it drains by gravity for a safe and gentle operation NOTE If the Express Steam option has been installed the AutoFlush will drain for ten minutes then refill with fresh water to begin the pre heat cycle INSTALLATION INSTRUCTIONS Plumbing to be performed by a qualified plumber and shall be in accordance with applicable national and local codes Unit drains by gravity A drain line that is lower than the AutoFlush assembly must be available The AutoFlush System valve outlet is 2 NPT Check plumbing code for receptor trap and vent requirements NO Use copper or brass nipple 2 NPT x 3 2 or longer not supplied to connect AutoFlush valve end B to the Drain Valve valve end A and B are indicated on bottom of AutoFlush Valve DO NOT REMOVE THE DRAIN VALVE Removal may cause equipment and property d
36. ontrol features an integral temperature sensor Locate the control in a location representative of the desired steambathing temperatures DO NOT locate the control above or near the steam head or direct steam emissions 4 on a vertical wall The control cable length is 30 feet Insure that the control and or steam generator are located accordingly An optional 60 foot cable is available PN 103990 60 for iTempo and PN 104117 60 for iSteam Contact a Mr Steam technical service representative if a 60 foot cable is required Excess control cable should be neatly coiled and twisted into a figure 8 IMPORTANT NOTES e f the control is installed outside the steam room a Remote Temperature Probe Part Number MSTS or iMSTS must be installed inside the steam room depending on the control Insure Mr Steam steam generator is iSteam or iTempo com patible and has a serial number 900000 or higher If iSteam is used with a generator having serial number 900000 through 930030 contact Mr Steam technical support for an upgraded PC board See instructions for the MSTS or iMSTS Temperature Probe located in the Control Installation Manual related to your specific control package before rough in or installation of control 18 mr steam Installation Operation amp Maintenance Manual HOMEOWNER SECTION READ ME FIRST ANZEMM As you follow these instructions you will notice warning and caution symbols This blocked informatio
37. p to gauge strength and suitability Limit to a maximum of a few drops for a steambathing session 4 The bather should exit the steambath IMMEDIATELY if dizziness occurs If skin irritation occurs stop using the oils immediately Remove any excess oil by washing in mild soap and water If ingested rinse mouth with water Administer water or milk to dilute Contact a physician immediately AGMIEJ Aromatic oils should be added to steamhead before turning on the steambath unit DO NOT add oil dur ing steambathing or when the steam head is heated Tightly close bottles when storing oils Keep bottles away from sources of ignition All drawings are for illustrative purposes only WARRANTY To view or download the Mr Steam Residential Generator Warranty Installation Operation amp Maintenance Manual AromaSteam 10ml bottle with integrated dropper 777 Recess for essential oil AromaSteam steamhead install per instructions on pg 8 and register your Product go to blog mrsteam com wr u 21 mr steamr Feel Good Inc www mrsteam com Products information and specifications are subject to change without notice Please call Sales amp Support at 1 800 76 STEAM East Coast or 1 800 72 STEAM West Coast for more information mr steam Sussman Automatic Corporation hello mrsteam com www mrsteam com p z 43 20 34th Street Long Island City NY 11101 9410 S La Cienega Blvd Ingl
38. physician regarding correct exposure E Obese persons and persons with a his tory of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a steambath F Persons using medication should con sult a physician before using a steam bath since some medication may induce drowsiness while other med ications may affect heart rate blood pressure and circulation SAVE THESE INSTRUCTIONS Ak LL REDUCE THE RISK OF OVERHEATING AND SCALDING 1 EXIT IMMEDIATELY IF UNCOMFORTABLE DIZZY OR SLEEPY STAYING TOO LONG IN A HEATED AREA IS CAPABLE OF CAUSING OVERHEATING 2 CHILDREN UNDER THE AGE OF 16 SHOULD NOT USE THE STEAM BATH 3 CHECK WITH A DOCTOR BEFORE USE IF PREGNANT DIABETIC IN POOR HEALTH OR UNDER MEDICAL CARE 4 BREATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL DRUGS OR MEDICATION IS CAPABLE OF CAUSING UNCONSCIOUSNESS 5 DO NOT CONTACT STEAM HEAD OR STEAM AT THE STEAM HEAD NOTE FOR ADDITIONAL SAFETY CONSIDERATIONS SEE OWNER S MANUAL The location where this owner s manual is kept shall be written in the space provided on the label using permanent ink Not Actual Size For a replacement warning label contact Mr Steam customer service at 1 800 76 STEAM or hello mrsteam com 19 THE OWNER S MANUAL CAN BE FOUND AT WWW MRSTEAM COM OR BY SCANNING THE QR CODE USE OF STEAM ROOM IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL
39. rounding wire to 1E 240 42 8 6 ground terminal provided 3 24 8 8 RA 208 58 6 4 4 Install a separate circuit breaker between supply and MS Super 575 20 3 34 8 8 unit Provide a power supply disconnect within sight 2E 240 50 6 6 of the steam generator or one that is capable of being 3 29 8 8 locked in the open position 208 73 4 3 i MS Super 675 5 0 3 42 8 6 5 For single phase units use two wire supply source and 3E 240 63 4 4 equipment grounding wire Neutral white wire is not 3 36 8 8 required See page 2 for room sizing tAll specifications shown are for 208V and 240V Consult factory for other voltage specifications PROVIDE A POWER SUPPLY DISCONNECT WITHIN SIGHT OF THE STEAM GENERATOR OR ONE THAT IS CAPABLE OF BEING LOCKED IN THE OPEN POSITION AS REQUIRED BY CODE FIELD POWER WIRING E Liquid level Level lobe Y i Water Feed 1 TO AVOID EQUIPMENT DAMAGE Rao 2 Rs DO NOT CONNECT POWER SUPPLY Knock Out DIRECTLY TO ELEMENTS A a i Water Feed 2 LT L2 Ground to be field wired _ AutoFlush Plug and cr 3 Super 1E 240 1 models Steam Outlet are not supplied with internal fusing Models MS 90E MS 40 i single phase wiring shown 4 All Drawings are for illustrative purposes only Consult with qualified licensed electrician for electrical Power Block Fuses Liquid Level installation Liquid Control Board Level Probe d Contactor i
40. s correct direction of flow Steam Generator Drain Valve Nipple DO NOT TURN OR REMOVE THE DRAIN VALVE shown in the correct open position AutoFlush Shown Fully Assembled Plumb to Drain Line All drawings are for illustrative purposes only mr steam Installation Operation amp Maintenance Manual OPTIONAL DRIP PAN Mr Steam strongly recommends the use of a drip pan in the unlikely event of a plumbing leak Locate the drip pan on a solid level surface and place the steam generator inside the drip pan nsure the steam generator is level see page 4 for ocating the steam generator All plumbing shall be performed by a qualified icensed plumber and in accordance with applicable national and local codes Check local plumbing code for receptor trap and vent requirements Drip pans drain by gravity The drip pan is equipped with an integral female Ja NPT fitting OPTIONAL EXPRESS STEAM only available factory installed Available for all MS Models Express Steam genera tors are equipped with a low power heating element and thermostat to keep the water in the tank warm enough to bring up steam quicker All Express Steam components and wiring are installed at the factory No additional wiring or plumbing is required by installers All drawings are for illustrative purposes only mr steam Installation Operation amp Maintenance Manual PARTS IDENTIFICATION DIAGRAMS Contactor i Liquid Level
41. the steam room If the 60 foot line is exceeded consult with factory The steam genera tor control locations must be taken into account A 30 foot cable is standard Contact Mr Steam to purchase an optional 60 ft cable PN 103990 60 for iTempo and PN 104117 60 for iSteam RESIDENTIAL STEAM GENERATORS SPECIFICATION CHART Amps for Wire 1 Total Adj Water Usage Shipping Model No KW 240v 1PH T Sizet I Room Vol i Gallonstt Dimensions Wt Ibs MS90E 5 21 10 100 0 67 4Y2 L x 14 H x 6 D 30 MS150E 6 25 8 i 150 i 0 80 4 Lx 14 H x 6 D 30 MS225E 75 32 8 225 I 1 0 4Y2 L x 14 H x 6 D 30 MS400E 9 38 8 i 360 i 12 4 Lx 144 H x 6 D 30 I 1 1 1 L 1 UPER 1E 10 42 8 i 475 i 1 4 7 Lx 18 H x 7 D 40 UPER 2E 12 50 6 i 578 i 1 6 7 Lx 18 H x 74 D 40 L 1 UPER 3E 15 63 4 675 2 0 7 Lx 18 H x 74 D 40 l 1 I T 1 1 1 1 UPER 4E 20 84 8 i 875 i 27 7 Lx 18 H x74 Dx2 80 l 1 I I UPER 5E 24 100 6 I 1075 32 7 Lx 18 H x 7 Dx 2 80 L L UPER 6E 30 125 4 i 1275 i 4 0 7 Lx 18 H x74 Dx2 80 I 1 L 1 IMPORTANT NOTES Add C1 suffix to Model No for 240V 1Ph Add B1 suffix to Model No for 208V 1Ph Models SUPER 1E 6E must use iTempo Plus control All Mr Steam MS Models are cULus Listed and CE approved NOTES All MS Generators available in 240v 1PH 208v 1PH and other voltages phases t Amps are for 240 1PH rated units Wire size AWG based on minimum 90 C rated THHN copper conductors Refer to the National Ele
42. ticular attention to room volume and construction If any questions please refer to Mr Steam sizing and selection guide on page 2 3 Marble or glass walls or ceilings ENLARGE the room s size requiring a generator larger than one based only on the room s cubic foot L x H x W volume 4 The physical size of the unit clearance for plumbing servicing and its distance from the steam room must all be considered before final installation 5 Consider any controls and accessories before initiating installation Read the Installation and Operation Manual of all controls and accessories available at www mrsteam com technical downloads STEAM ROOM GUIDELINES 1 Steam room must be completely enclosed with full walls door floor and ceiling NAZI The peel and stick warning label located in this manual is an essential part of providing a safe environment for steam room users The peel and stick warning label must be applied to the wall of the shower or steam enclosure at a point that is visible to all users Failure to install this sticker may result in serious injury or death The location where this owner s manual is kept shall be written in the space provided on the label using per manent ink For a replacement warning label contact Mr Steam 2 It is recommended that a gasketed door is used for steam containment 3 NIE To prevent slip and fall hazards non skip strips must be installed on the steam room floor 4 Chec
43. ush a minimum of two three hours after the con trol has been turned off to insure that the water has cooled Draining immediately after a steam cycle may expose PVC and other piping to high temperature water Check local codes The unit will refill automatically when the control is activated again In areas of hard water a Mr Steam AutoFlush system is recommended for generator longevity AMZGLNEJ Failure to allow the water to cool will expose the equipment and user to scalding water and cause property and personal injury mr steamr USING MR STEAM ESSENTIAL OILS Enjoy AromaSteam essential oils by placing a drop or two into an unheated AromaSteam steamhead as shown in the illustration Only use Mr Steam AromaSteam essential oils in the Mr Steam AromaSteam steamhead NILGIMDN Essential oils and or aroma therapy can cause inflammation burns headache nausea and allergic reactions Consult a physician before using aroma therapy 1 Use essential oils with caution Essential oils are for exter nal use only Keep out of reach of children Essential oils are highly concentrated and are potent substances and should not be applied directly to the skin as they can be irritants Use essential oils with caution 2 Place the drops into the Mr Steam AromaSteam steamhead recess prior to turning on the steambath DO NOT place drops in a hot steam head as serous injury can result if you do not follow this warning 3 Start with one dro
44. y months of pregnancy Pregnancy or possibly pregnant women should consult a physician regarding correct exposure injury or death if improperly used Steam rooms contain steam and elevated temperatures Please read and observe all warnings in this manual before installing or using a steam room E Obese persons and persons with a his fh i high bl 4 To reduce the risk of injury M me ow oni bleed pressure circulatory system problems A The wet surfaces of steam enclosures or diabetes should consult a physician may be slippery Use care when entering before using a steambath ot leaving F Persons using medication should con B The steam head IS hot DO NOT touch the sult a physician before using a steam steam head and avoid the steam near bath since some medication may the steam head induce drowsiness while other medica C Prolonged use of the steam system can raise tions may affect heart rate blood pres excessively the internal human body temper sure and circulation ature and impair the body ability to regu late its internal temperature hyperthermia Limit your use of steam to 10 15 minutes until you are certain of your body s SAVE THESE INSTRUCTIONS reaction HYPERTHERMIA occurs when the internal temperature ofthe a Failure to perceive heat body reaches a level several degrees above the normal body b Failure to recognize the need to exit the steambath temperature of 98 6 F The symptoms of hypertherm
45. yhole slots are provided for wall mounting Insure the steam generator is properly secured and level when mounting with keyhole slots to prevent damage to the steam generator 7 Install steambath generator in an upright position only to prevent damage to the generator IMPORTANT NOTES Items 8 11 8 Install anti water hammer device as necessary 9 Provide a minimum of 12 inches at both ends and top of the steam generator or as required for servicing See page 8 10 Provide unions as required to facilitate installation and disconnection of piping 11 Mr Steam controls can be located inside the steam room or on the outside of the steam room See the Control Installation Manual for your specific control package for specific details 12 The MS series of steam generators are for residential use only Commercial or other nonresidential applications void the warranty and may adversely affect product per formance and may represent a safety hazard NOTE Mr Steam Generators inclusive of the iTempo and iSteam series Controls are CE and UL listed Suitable for operation in ambient not exceed ing 45 C 113 F mr steam Installation Operation amp Maintenance Manual TYPICAL MR STEAM INSTALLATION LL ed F iSteam iTempo or iTempo Plus X Control Refer to Control Installation Manual 3 4 for installation information MAA CAUTION The control features an integral temperature sensor Locate t
46. zardous condition The MS series of steam generators are for residential use only Commercial or other nonresidential applications void the warran ty and may adversely affect product performance and may repre sent a safety hazard customer service at 1 800 76 STEAM or hello mrsteam com REDUCE THE RISK OF OVERHEATING AND SCALDING 1 EXIT IMMEDIATELY IF UNCOMFORTABLE DIZZY OR SLEEPY STAYING TOO LONG IN A HEATED AREA IS CAPABLE OF CAUSING OVERHEATING 2 CHILDREN UNDER THE AGE OF 16 SHOULD NOT USE THE STEAM BATH 3 CHECK WITH A DOCTOR BEFORE USE IF PREGNANT DIABETIC IN POOR HEALTH OR UNDER MEDICAL CARE 4 BREATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL DRUGS OR MEDICATION IS CAPABLE OF CAUSING UNCONSCIOUSNESS 5 DO NOT CONTACT STEAM HEAD OR STEAM AT THE STEAM HEAD NOTE FOR ADDITIONAL SAFETY CONSIDERATIONS SEE OWNER S MANUAL WHICH IS KEPT THE OWNER S MANUAL CAN BE FOUND AT WWW MRSTEAM COM OR BY SCANNING THE QR CODE s USE OF STEAM ROOM IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL CAN BE DANGEROUS AND CAN RESULT IN INJURY THROUGH SLIP AND FALL OR OTHERWISE MT SCE AM 43 20 34th Street Lang Island City NY 11101 1 800 76 STEAM wwwmreteam ncm PURLOLOTA 7 14 Not Actual Size If acrylic fiberglass or other non heat resistant mate rials are used as part of the steam room enclosure Consult with the material manufacture and see pg 7 Installing the Steamhead for additional details