Home

Armacost Lighting DIM12V60-B Installation Guide

image

Contents

1. and wire this product contact a qualified electrician Failure to install this device properly may result in electrical shock or fire Do not install Class 2 low voltage wiring in the same runs as AC main power If AC and low voltage wires cross keep them at 90 degree angles Power supply location and voltage drop Voltage drop is a natural occurrence in all low voltage lighting systems It is the gradual decrease in voltage that occurs from your power supply to your LED lighting Voltage drop only becomes undesirable if you notice the brightness in one area of your lighting is objectionably different than in another area As a practical approach to installing LED tape lights test your lighting prior to final installation If voltage drop appears to be a concern use shorter lengths of DC power feed wires or switch to a thicker gauge wire lower AWG number a Excessive voltage drop reduced brightness and color accuracy a Shorter and or thicker wires higher brightness and color consistency Longer LED tape an increase in voltage drop For an online voltage drop calculator visit www armacostlighting com voltagedrop SPECIFICATIONS Input voltage sicisiiuisihiettrenintnitorer inde 120V AC 50 60Hz Output voltage scenie n 12V DC 5A Max Power factor 2 os cschaetaceldncagunteuduneeacanutewneenendtureess gt 98 ETHIC ENC cen AE gt 85 EMCIOSUFE INATSKIAl 2ccscc ccsas cesutlandeveaeiny rina Metal P protectioNe
2. cessisse IP60 dry location only DIMENSION Ssnan 8 Lx2 Wx1 8 H 207mmL x 50mmW x 43mmH RoHS Ke COMPLIANT Intertek ERT 4002670 Limited 1 year warranty Improper installation improper powering abuse or failure to use this device for its intended purpose will void warranty Proof of purchase is required for all returns Questions Email support armacostlighting com lb LISTED Conforms to UL standard 2108 Certified to Canada CSA standard C22 2 No 250 0 08 3rd Edition TYPICAL WIRING DIAGRAM AND COMPATIBLE DIMMERS This power supply is compatible with Lutron CeL and Digital dimmers and most electronic low voltage ELV and other Universal dimmers manufactured by Lutron Legrand and Insteon Do not use with Armacost Lighting 12V DC low voltage dimmers For compatible dimmers go to www armacostlighting dimmer list Green Wire Skylark CeL Model SCL 153P shown Ground All CeL dimmers require 2 wires for hookup and have an adjustment to set dimming range Note All electronic low voltage ELV dimmers will require a neutral wire connection Black Wire 120V AC Live HOT 3 Red White Wire amp Use for a 3 way switch connection O White Wire 120V AC Green Wire Neutral Ground Black Wire 12V Negative 12V Red Wire 12V Positive DC OUTPUT White Wire Neutral Black Wire Line In 12V DC LED LIGHTING B k 1 O O O O 0 0 0 0 oO on oO
3. oO oo H Power supply is for direct wire only and includes NEMA 1 listed metal enclosure with eight 8 7 8 knockouts After removing knockouts install suitable strain reliefs and route wires appropriately to fit installation location A ground wire is attached with lug and nut to the inside of the enclosure Wire nuts included All wiring must be in accordance with national and local electrical codes low voltage Class 2 circuit If you are unclear as to how to install and wire this product contact a qualified professional 2012 14 Armacost Lighting All rights reserved
4. Armacost fi LIGHTING 0 60 Watt Class 2 AC Dimmable Electronic Power Supply Model DIM12V60 Highly efficient stabilized 12V DC power for LED lighting Delivers the right amount of power needed whether powering a 3 watt LED puck light 60 watts of LED tape lighting or a combination of both No minimum power load is required for effective flicker free dimming For use only with white LED lighting requiring 12V DC constant voltage power Power supply will shut off in case of lighting overload open circuit short circuit over temperature or other fault Unit will automatically restart after the fault has been corrected Not for use with color changing RGB LED lighting Use only with approved compatible AC dimmers Installation Guidelines a Power supply is for direct wire only For dry location use only Allow for ventilation 120V AC Power to this LED power supply must be disconnected at all times during installation Total wattage of all LED fixtures used must not exceed the 60 watt rating of this power supply Use only insulated staples or plastic ties to secure cords and wires Route and secure wires so they will not be pinched or damaged All wiring must be in accordance with national and local electrical codes low voltage Class 2 circuit For wire runs inside of walls use properly certified CL2 or better cabling and appropriate mounting hardware If you are unclear as to how to install

Download Pdf Manuals

image

Related Search

Related Contents

NX-4140 Bedienungsanleitung - Mode d`emploi  モバイルハンドスキャナー 取扱説明書    Samsung 713BMPLUS Instrukcja obsługi  HP Color LaserJet CM6040/CM6030 MFP User Guide    コンパクト& ハイパワー!  データ分散保存システム  

Copyright © All rights reserved.
Failed to retrieve file