Home
Illumine CLI-EMM006043 Installation Guide
Contents
1. in most industrial installations A WARNING This product is designed to use only these parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage
2. anv part Is damaged or missina 4 WARNING This product is designed to use only those parts supplied with thls product and or any accessorles designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with thls product by Emerson Electric Co could result In personal injury or property damage Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds 4 WARNING Turning off wall switch Is not sufficient To avoid possible electrical shock be sure electricity Is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock Fan Assembly Instructions C11 Put the upper canopy and lower canopy on the hanger pipe assembly facing in the proper direction See Figure 1 NOTE For HF948 Only Hf you are going to use the 8 pipe first remove the hanger assembly from the 22 pipe and install it on the 8 pipe Be sure that the nut is securely tightened and the hairpin clip properly installed HANGER ASSEMBLY UPPER CANOPY a LOWER HANGER PIPE CANOPY ASSEMBLY Figure 1 72 Pass the motor wires and
3. balanced sets of three Do not mix blades if installing more than one fan C6 Install the blade gaskets between the blades and the motor See Figure 3 O7 Install the three blades onto the motor using spring washers M6 x 1 2 screws and blade gaskets supplied Securely tighten the six blade screws A WARNING To reduce the risk of personal injury do not bend the blade flanges when installing the blades bafancing the blades or cleaning the fan Do not insert foreign objects between rotating fan blades M6 x 1 2 SCREW 2 PER BLADE SPRING WASHER 2 PER BLADE Figure 3 Hanging Your Heat Fan 1 Attach the appropriate J hook to the A WARNING Turning off wall switch Is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be In accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock 4 WARNING To reduce the risk of fire electric shock or personal injury a The fan must be hung with at least 10 foot of clearance from floor to blades See Figure 4 b Your support beam or joist must be secure and capable of withstanding a load of at least 50 pounds A WARNING The fan must be hung with at least 10 of clearance from floor to blades Figure 4 o CEIL A 10 FOOT MINIMUM RE ee FLOOR LP OOCCPOC EE Figure 4 A WA
4. of cable and saddle on long end of the fan motor to the green grounding wire from the supply source Securely connect wires with wire connectors supplied See Figure 9 CAUTION Use larger U L listed wire connectors if supply source wires are larger than 12 AWG thon SUPPLY GROUND WIRE WHITE SUPPLY GREEN WIRE GROUND FROM FAN NEUTRAL WIRE CONNECTORS 3 WHITE FAN WIRE BLACK FAN WIRE Figure 9 cable Improper installation reduces 2 Securely connect the fan motor white the efficiency of the connection by as much as 40 percent wire to the supply white neutral wire using a wire connector supplied Figure 9 Securely connect the fan motor black wire to the supply black hot wire using wire connector supplied After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black leads on the other side of the outlet box o A WARNING Maintenance Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire CAUTION Do not operate fan until blades are in place Nolse and fan damage could result To avoid possible electrical shock be sure electricity is turned off at the main service box before servicing bearings are permanently lubricated and do not require further lubrication CLEANIN
5. retention cable through the hanger pipe assembly and seat the hanger pipe in the motor yoke See Figure 2 RETENTION RUBBER CABLE 1 GROMMET MOTOR WIRE 3 HANGER PIPE ASSEMBLY HAIRPIN CLIP MOTOR YOKE SHOWN FOR CLARITY CLEVIS PIN 5 16 18 SETSCREW 2 Figure 2 03 04 Align the clevis pin holes in the hanger pipe with the holes in the motor yoke Install the clevis pin and secure with the hairpin clip Figure 2 The clevis pin must go through the holes in the motor yoke and the holes in the hanger pipe Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the rubber grommet to make sure the clevis pin is properly installed Install and securely tighten the two 5 16 18 setscrews in the motor yoke against the hanger pipe using the allen wrench supplied Figure 2 4 WARNING It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed as shown in Figure 3 could result in the fan falling canopies yot O 5 Slide the lower canopy down the hanger pipe and securely tighten the set screw against the hanger pipe See Figure 3 CAUTION Blades come in
6. G This fan may be wiped off _4 WARNING To avoid possible fire or shock make sure with a damp cloth Do not allow the motor that the electrical wires are completely to get wet Do not use solvents or harsh inside the outlet box and not pinched detergents between the ceiling cover and the celling y WARNING g3 Slide the upper canopy up the rod within 1 4 of the ceiling or beam and securely tighten the setscrew the blades and create the possibility of an 14 If a remote speed control is to be used electrical shock refer to the instructions included with that control for proper instailation and Do not use water when cleaning your ceiling fan It could damage the motor or wiring C5 Restore power Accessories 16 After completing installation test run 11 Downrod Extension Kits see store or fan in normal operation manner catalog ee hie ay sss sie by 1 2 Ceiling Fan Light Controls see store or binding as a result of tight cable if this catalog should happen shut off power supply O3 Suitable for use with Emerson Solid and re check instructions to correct State Speed Control problem NOTE When any solid state motor A WARNING speed control is used a humming noise may be present in the fan on low The use of any other control not speed This hum in no way affects the specifically approved for this fan could operation of the fan and is acceptable result in fire shock and personal injury
7. READ AND SAVE THESE INSTRUCTIONS 48 amp 56 a Industrial Heat Fans Owner s Manual HF948 Net Weight 18 7 Lbs HF956 Net Weight 22 2 Lbs 4 WARNING WARNING To avoid fire shock and serious personal injury follow these instructions Safety Instructions Read your owner s manual carefully and keep It for future reference Before servicing or cleaning unit switch power off at service panel and lock service panei disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Be careful of the fan and blades when cleaning painting or working near the fan Always turn off the power to the celllng fan before servicing Suitable for use with solid state speed controls Do not bend the blade flanges when installing the blades balancing the blades or cleaning the fan Do not Insert foreign objects In between the rotating blades Additional Safety Instructions for Installation To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades All wiring must satisfy National and Local Electrical Codes Use the National Electrical Code lf Local Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a
8. RNING Read and follow Instructions carefully Failure to comply with instructions could result in risk of fire electric shock fan falling and injury to persons 4 WARNING J Hook must be supported by bullding structure building structure member On Steel Beam Locate and drill a 13 32 diameter hole in the beam See Figure 5 Use a flat washer lock washer and nut on both sides of the beam Position the J hook so that the hook extends 2 1 2 out of outlet box Securely tighten both nuts See Figure 5 CAUTION When the threaded bolt hook is used be careful to securely tighten with supplied lockwashers and nuts NUT LOCK WASHER FLAT WASHER Figure 5 On Wood Joist Locate and drill a pilot hole in the wood joist Install the screw type J hook so that hook extends 2 1 2 below the outlet box See Figure 6 CAUTION The pilot hole should be drilled no larger than the minor diameter of the screw threads on the hook 1 4 max Do not put a lubricant on the J hook At least 1 1 2 of the screw threads should be secured into the structural wood joist WOOD JOIST 1 1 2 OUTLET Figure 6 Y 2 Lift the fan onto the J hook and position as shown in Figure 7 Make sure the motor wires and retention cable at the top of the hanger pipe are positioned behind J hook as illustrated in Figure 7 CAUTION The electrical wires and retention cable must not be placed between the rubber roll
9. er and the hook but rather as illustrated in Figure 7 RETENTION CABLE Figure 7 O3 This fan is equipped with the required retention cable This cable must be Wiring Your Heat Fan A WARNING To avoid possible fire or electrical shock do not pinch wires between the hanger ball downrod assembly and hanger bracket NOTE If you feel that you do not have enough electrica wiring knowledge or experience have your fan installed by a licensed electrician A WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation affixed to the building structure and O1 Connect the green grounding wire from securely clamped in such a manner to support the weight of the fan in the event the mounting hook or other parts fail After wrapping cable around or to a structural member that will support 50 pounds secure cable with supplied cable clamps as illustrated in Figure 8 NOTE Leave approximately 3 but no more than 5 of slack on this safety cable to allow for possible fan movement Do not exceed more than 5 total slack CAUTION It is important to note the proper installation position of the cable clamps as illustrated in Figure 8 To obtain maximum holding power install U bolt section of clip on dead or short end
10. licensed electrician The outlet box and Joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 50 Ibs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualifled electrician if in doubt The fan must be mounted with the fan blades at least 10 feet from the floor to prevent accidental contact with the fan blades Suitable for use with solid state speed controls Always properly connect the retention cable Included with thls fan follow the Installation Instructions section carefully The support beam or foist must be secure and capable of supporting at least 50 pounds Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wirlng have your fan installed by a licensed electriclan WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could res
11. ult In personal injury or property damage WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades WARNING To reduce the risk of electric shock this fan must be Installed with an isolating wall control switch DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep it in a safe place for future use Checking Contents of Package Before discarding packaging material be certain all parts have been removed O1 Unpack the items carefully to avoid damage to any of the components 12 Make certain you receive the following parts a Motor subassembly b Blades 3 each c Upper canopy d Lower canopy e J hook bag assembly containing 1 J hook 2 each 2 Flat washers 2 each 3 Lock washers 2 each 4 Hex nuts 2 each f 24 Hanger pipe assembly g 8 Hanger pipe HFS48 Only h Bag of parts containing 1 Wire connectors 3 each 2 Cable clamps 2 each 3 M6 x 1 2 Hex head screws 6 each 4 M6 Spring washers 6 each 5 Blade gaskets 3 each 6 Clevis pin 7 Hairpin clip 8 5 16 18 x 1 4 Setscrews 2 each 9 Allen wrench NOTE Intermixing blades between fans can cause excessive wobble Keep blades in original sets of three A WARNING Do nat install or use fan if
Download Pdf Manuals
Related Search
Related Contents
Manual del Operador Emerson H800 Instruction Manual Téléchargement FDR - Ramsar Sites Information Service Bruken - Canceles Premium, S de RL de CV Xbox 360® 取扱説明書 - Center Spots & Velvets Salt 1 Graco 7500 User's Manual Samsung Galaxy S6 edge Käyttöopas Lenco DVT-1932 19" Black Copyright © All rights reserved.