Home

Lutron SFSQ-FH-AL Instructions / Assembly

image

Contents

1.
2. Important Wiring Information When making wire connections follow the recommended strip lengths and combinations for the supplied wire connectors Note Wire connectors provided are suitable for copper wire only For aluminum wire consult an electrician Small Strip insulation 3 8 in 10 mm for 14 AWG 1 5 mm wire Strip insulation 1 2 in 13 mm for 16 AWG 1 0 mm or 18 AWG 0 75 mm wire Use to join one 14 AWG 1 5 mm supply wire with one 16 AWG 1 0 mm or 18 AWG 0 75 mm control wire Large Strip insulation 1 2 in 13 mm for 10 AWG 6 mm 12 AWG 2 5 mm or 14 AWG 1 5 mm wire Strip insulation 5 8 in 16 mm for 16 AWG 1 0 mm or 18 AWG 0 75 mm wire Use to join one or two 12 AWG 2 5 mm or 14 AWG 1 5 mm supply wires with one 10 AWG 6 mm 12 AWG 2 5 mm 14 AWG 1 5 mm 16 AWG 1 0 mm or 18 AWG 0 75 mm control wire Twist wire connector tight Be sure no bare wire is exposed ES e Connect the green ground wire on the control to the green or bare copper ground wire in the wallbox see Important Note 3 Wire the control e Connect the black wire on the control to either of the wires removed from the switch e Connect the remaining wire on the control to the remaining wire removed from the switch Ground Neutral Mount and align control Install wallplate Align control and tighten screws T Turn power
3. cortada ry la alimentacion a cada interruptor antes de proceder El incumplimiento podria causar lesiones graves o mortales we 5 o Verifique el tipo de control que ser usado En la caja de embutir debe haber dos alambres revestidos conectados a dos tornillos Nota No connecte a un accesorio de luz Tierra Alambre verde o de cobre desnudo Desconecte los alambres del interruptor Conexiones Posteriores Coloque el destornillador Saque el alambre Tornillos Terminales Dele vueltas al tornillo para soltarlo Nota Importante Su interruptor de pared puede tener dos cables conectados al mismo borne de tornillo vea los ejemplos ilustrados abajo Una ambos cables con cinta adhesiva antes de desconectarlos Cuando realice el cableado conecte los cables en el Atenuador de la misma forma que estaban conectados al interruptor 1 800 523 9466 24 horas 7 d as www lutron com Instrucciones importantes de cableado Cuando se conecten cables la longitud expuesta de los extremos y la combinaci n de conexiones deber n estar de acuerdo con las recomendaciones para el conector suministrado Nota Los conectores suministrados son apropiados para alambres de cobre nicamente Consulte a un electricista en caso de usar conductores de aluminio Tuerza el conectador de Peque o alambre hasta que este Alambres de 1 5 mm 14 AWG quite la aislaci n
4. ON Controles de Velocidad Para Ventiladores FS 5F 5A 120V 60 Hz SFSQ F 15A 120V 604z FSQ 2F 15A 120V 60Hz SFSQ F HO 2A 120V 60Hz LTFSQ 2H 15A 120V 60Hz LTFSQ FH 15A 120V 60Hz Notas Importantes Favor de leer antes de instalar 1 PRECAUCI N Para evitar el calentamiento excesivo y posibles da os a otros equipos no lo use para controlar recept culos portal mparas fluorescentes o aparatos cuya fuente de alimentaci n incluya un transformador 2 Ajuste los ventiladores de varias velocidades a su velocidad m xima antes de instalar los controles 3 Sien la caja de embutir no hay accesso a una conexi n de tierra la norma NECe 2008 Article 404 9 permite instalar como reemplazo un atenuador sin conexi n a tierra en tanto se utilice una placa de pared de pl stico no combustible Para este tipo de instalaci n aisle o elimine el conductor verde de tierra del atenuador y utilice una placa adecuada tal como la Clarom o Fassadarm de Lutron 4 Nouse el control con un ventilador y una l mpara que funcionen con el mismo interruptor En nuevas instalaciones conecte un interruptor de prueba antes de instalar el control 6 Use los controles FSQ 2F SFSQ F y SFSQ F HO solamente con un ventilador de aspas para techo Use s lo un ventilador de aspas para techo por cada control 7 Use los controles FS 5F solamente con ventiladores con la marca Adecuado para usarse con controles de velocidad de ventiladores de estad
5. en 10 mm firme 3 8 in del extremo Aseg rese que no Alambres de 1 5 mm 16 0 18 AWG pl quite la aislaci n en 13 mm 1 2 in del extremo p i Uselos para conectar un cable de suministro de 1 5 mm 14 AWG con un cable de control de 1 5 mm 16 o 18 AWG Grande Alambres de 6 mm 2 5 mm o 1 5 mm 10 12 0 14 AWG quite la aislaci n en 13 mm 1 2 in del extremo Alambres de 1 0 mm o 0 75 mm 16 o 18 AWG guite la aislaci n en 16 mm 5 8 in del extremo Uselos para conectar uno o dos cables de suministro de 2 5 mm o 1 5 mm2 12 o 14 AWG con un cable de control de 6 mm 2 5 mm 1 5 mm y I rande 1 0 mm o 0 75 mm 10 12 14 16 o 18 AWG Peque o Instalaci n de un atenuador en un circuito unipolar e Conecte el alambre verde de tierra del control al alambre de tierra de color verde o de cobre desnudo en la caja de embutir vea Notas Importantes 3 e Conecte un alambre negro del control a cualquiera de los alambres removidos del interruptor e Conecte el alambre restante del control al alambre restante removido del interruptor Tierra Control Vivo Negro ha Negro g 120 V 60 Hz Verde ES Ventilador Tierra L _ Neutral Monte y alinie el control Instale la placa de pared Alinie control y apriete los tornillos ki Encienda la corriente ee oy 3 ey ae Oye O ea 2n 1077 PE Sn pesao do
6. A Asistencia Tecnica Si tiene preguntas referentes a la instalaci n o operaci n de este producto llame al Centro de Soporte T cnico de Lutron Por favor suministre el numero exacto del modelo con su llamada 1 800 523 9466 E U A Canad y el Caribe para M xico llame 1 888 235 2910 de otros pa ses llame 1 610 282 3800 Fax 1 610 282 6311 Garant a Limitada V lido solamente en los E U A Canad Puerto Rico y el Caribe Lutron reparar o reemplazar a su criterio cualquier unidad cuyos materiales o fabricaci n resulten defectuosos en el t rmino de un a o despu s de la fecha de compra Para obtener servicio de garant a la unidad debe devolverse al lugar de compra o enviar con franqueo pago a Lutron 7200 Suter Road Coopersburg Pennsylvania 18036 1299 ESTA GARANT A SE OFRECE EN LUGAR DE CUALQUIER OTRA GARANT A EXPRESA LA GARANT A IMPL CITA DE COMERCIABILIDAD EST LIMITADA A UN A O A PARTIR DE LA FECHA DE COMPRA ESTA GARANT A NO CUBRE LOS COSTOS DE INSTALACI N DESMONTAJE NI REINSTALACI N TAMPOCO CUBRE DA OS RESULTANTES DE UN USO IMPROPIO O ABUSO NI DA OS DEBIDOS A UNA INSTALACI N O CONEXI N INCORRECTA ESTA GARANT A NO CUBRE DA OS INCIDENTALES NI RESULTANTES LA OBLIGACI N DE LUTRON CON RESPECTO A CUALQUIER RECLAMACI N POR DA OS RELACIONADOS CON LA FABRICACI N VENTA INSTALACI N ENTREGA USO REPARACI N O REEMPLAZO DE LA UNIDAD NO SUPERAR EN NING N CASO EL PRECIO DE COMPRA Esta ga
7. Es e Easy to follow Instructions e Instrucciones F ciles de Seguir P N 030 1051 LSO L 0 0 N d J n ap SI 1984 S3U0199N 1 SU e SUOI ONJ SU MO 0J 0 ASe J e ae Fan Speed Controls FS 5F 5A 120V 60 Hz SFSQ F 15A 120V 604z FSQ 2F 15A 120V 60Hz SFSQ F HO 2A 120V 604Hz LTFSQ 2H 15A 120V 60Hz LTFSQ FH 15A 120V 60Hz Important Notes Please read before installing 1 CAUTION To avoid overheating and possible damage to other equipment do not use to control receptacles fluorescent lighting fixtures or transformer supplied appliances Set multi speed fans to their highest setting before installing controls When no grounding means exist within the wallbox then the NECe 2008 Article 404 9 allows a dimmer without a grounding connection to be installed as a replacement as long as a plastic noncombustible wallplate is used For this type of installation cap or remove the green ground wire on the dimmer and use an appropriate wallplate such as Lutron s Claros or Fassadae series wallplates Do not use control with a fan and light that operate with the same switch For new installations wire a test switch before installing the control Use FSQ 2F and SFSQ F controls with a ceiling paddle fan only Use only one ceiling paddle fan per control 7 Use FS 5F controls only with fans marked Suitable for use with solid state fan speed controls 8 Do not wire an FSQ 2F SFSQ F or SFSQ F HO in a ci
8. aribbean Internet www lutron com Lutron will at its option repair or replace any unit that is defective in materials or manufacture within one year after purchase For warranty service return unit to place of purchase or mail to Lutron at 7200 Suter Rd Coopersburg PA 18036 1299 postage pre paid THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION REMOVAL OR REINSTALLATION OR DAMAGE RESULTING FROM MISUSE ABUSE OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES LUTRON S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE SALE INSTALLATION DELIVERY OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT This warranty gives you specific legal rights and you may have other rights which vary from state to state Some states do not allow the exclusion or limitation of incidental or consequential damages or limitation on how long an implied warranty may last so the above limitations may not apply to you This product may be covered by one or more of the following U S patents 4 939 383 5 191 971 and corresponding foreign patents Lutron Claro and Fassada are registered trademarks of Lutron Electronics Co Inc NEC is a registered trademark of the National Fire Protection Association Quin
9. cy Massachusetts 2008 Lutron Electronics Co Inc LUTRON Lutron Electronics Co Inc 7200 Suter Road Coopersburg PA 18036 1299 U S A Made and printed in China 10 08 P N 030 1051 Rev A Lutron Technical Support Center Installation For installations involving more than one control in a wallbox refer to Multi Unit Installations before beginning EI WARNING Turn power OFF at circuit breaker or remove fuse OFF EJ Removing wallplate and switch e Remove wallplate and switch mounting screws e Carefully remove switch from wall do not remove wires Warning Before proceeding verify that a power to the switch is OFF Otherwise death or serious injury could result py E Verify your application Switch must have two insulated wires connected to two screws and a bare copper or green wire connected to a green screw Note Do not connect to a light fixture Ground Bare Copper or Green Wire El Disconnect switch wires OR Terminal Screws Backwired Turn screws to loosen Insert screwdriver Pull wire out Important Note Your wall switch may have two wires attached to the same screw see illustrations below for examples Tape these two wires together before disconnecting When wiring connect wires to the Dimmer the same way they were connected to the switch 1 800 523 9466 24 hrs 7 days www lutron com
10. o s lido 8 No cablee un control FSQ 2F SFSQ F o SFSQ F HO en un circuito en el cual haya un cortocircuito receptaculo GFCI 9 Los controles pueden sentirse tibios al tacto durante su operaci n normal 10 Realice la instalaci n de acuerdo con todos los c digos el ctricos nacionales y locales 11 Limpie la unidad con un pa o suave y h medo nicamente No use agentes qu micos de limpieza 12 Para uso en interiores solamente 13 Los controles deben ser montados verticalmente Vea el sello en el control para la posici n correcta Instalaciones de Unidades Multiples Cuando combine varios controles en una sola caja de embutir quite todas las secciones laterales internas antes de realizar el cableado vea m s abajo Use unas pinzas para doblar hacia arriba y abajo cada secci n lateral hasta que se rompa Los controles FS 5F requieren la reducci n de su capacidad Consulte el cuadro siguiente para conocer la capacidad m xima Los controles FSQ 2F SFSQ F y SFSQ F HO no requieren reducci n alguna de la capacidad en No retire las secciones exteriores a o Al control del medio se la han quitado las secciones laterales A cada control se le ha quitado la secci n interior Dos Secciones Eliminadas Una Secci n Eliminada Sin Eliminar N mero de Modelo Secciones FS 5F 5A 4A 3
11. rant a otorga derechos legales espec ficos pero se podr a tener otros derechos que var an de un estado a otro Algunos estados no permiten la exclusi n o limitaci n de da os incidentales ni resultantes ni limitaciones en la duraci n de una garant a impl cita por lo cual es posible que las limitaciones mencionadas anteriormente no correspondan en ciertos casos Este producto est cubierto por uno m s de los siguientes patentes Estounidenses 4 939 383 5 191 971 y por los patentes extrangeros correspondientes Claro y Fassada sea un marcas de Lutron Electronics Co Inc Lutron es una marca registrada de Lutron Electronics Co Inc NEC es una marca registrada de National Fire Protection Association Quincy Massachusetts O 2008 Lutron Electronics Co Inc LUTRON Internet www lutron com Lutron Electronics Co Inc 7200 Suter Road Coopersburg PA 18036 1299 U S A Hecho e impreso en China 10 08 P N 030 1051 Rev A Centro de Soporte T cnico de Lutron Instalaci n Para instalaciones m ltiples en una caja de embutir antes de empezar vea las instrucciones para unidades m ltiples EI CUIDADO Apague la corriente en la caja de cortacircuitos o remueva los fusibles L od OFF Remueva la placa de pared y el interruptor e Quite los tornillos de montaje del interruptor e Cuidadosamente remueva el interruptor de la pared no remueva los cables Precauci n Comprobar que est
12. rcuit with a GFCI breaker receptacle 9 Controls may feel warm to the touch during normal operation 10 Install in accordance with all national and local electrical codes 11 Clean control with a soft damp cloth only Do not use any chemical cleaners 12 For indoor use only 13 Controls must be mounted vertically See stamp on control for correct positioning Multi Unit Installations When combining controls in a wallbox remove all inner side sections before wiring see below Use pliers to bend each side section up and down until it breaks off FS 5F controls require reduction of their capacity Refer to chart below for maximum capacity FSQ 2F SFSQ F and SFSQ F HO controls do not require capacity reduction Do Not Remove Outside Sections Inside Sections Are Side Sections Are Removed From Each Removed From Both Control Sides Of Middle Control No Sides 1 Side 2 Sides Removed Removed Removed oN oo gt Model Number FS 5F 4A 3A Technical Assistance If you have questions concerning the installation or operation of this product call the Lutron Technical Support Center Please provide exact model number when calling 1 800 523 9466 U S A Canada and the Caribbean Other countries call 1 610 282 3800 Fax 1 610 282 6311 Limited Warranty Valid only in U S A Canada Puerto Rico and the C