Home

Hampton Bay 51353 Installation Guide

image

Contents

1. ing the slide on mounting bracket A over the two screws UU 9 A provided with the outlet box If necessary use leveling washers not included between the slide on mounting bracket A and the i outlet box Note that the flat side of the mounting bracket A is 0 toward the outlet box O Securely tighten the two mounting screws UU c D l E Assembly Hanging the Fan continued 6 Setting the remote control codes Installing the receiver NOTE The frequencies on your receiver and remote control have been preset at the factory Before installing the receiver make A sure the dip switches on the receiver and remote control are set to the same frequency The dip switches on the remote control are located inside the battery compartment remember to disconnect power The electrical wiring must meet all local and national electrical code requirements The electrical source and fan must be 110 120 volt 60Hz WARNING To reduce the risk of fire or electric shock CAUTION If other fan wires are a different color have this unit NOTE This remote is equipped with a 16 code combination A installed by a licensed elec
2. 8 Como hacer las conexiones el ctricas ADVERTENCIA Cada cable no suministrado con este ventilador est dise ado para aceptar un m ximo de un solo circuito el ctrico dom stico de calibre 12 y dos cables del ventilador Si tienes un cableado dom stico de calibre superior a 12 o vas a conectar m s de un cable dom stico al sistema de cableado del ventilador consulta con un electricista acerca del tama o adecuado de las tuercas para cable IMPORTANTE Usa las tuercas de pl stico para conectar cables EE incluidas con tu ventilador Sujeta los conectores con cinta de electricista y aseg rate de que no haya conexiones o cables sueltos Conecta el conductor a tierra del cable de 120 V puede ser un cable desnudo o un cable con aislante verde al los cable s terminal es a tierra verde s Il del ventilador usando una tuerca de pl stico para conexi n de cables EE Conecta el cable blanco del motor del ventilador LL al cable blanco LL del receptor NN usando un conector de cables pl stico EE Conecta el cable negro del motor del ventilador KK al cable negro KK del receptor NN usando un conector de cables pl stico EE Conecta el cable azul del motor del ventilador JJ al cable azul JJ del receptor NN usando un conector de cables pl stico EB Conecta el cable rojo 00 del receptor NN al cable negro positivo de suministro de energ a KK usando un conector d
3. Si usas el kit de luces de ventilador de techo aseg rate de que los tornillos que sujetan el vidrio est n bien colocados Verifica que las bombillas est n bien aseguradas Aseg rate de que la cubierta est a corta distancia del techo No debe tocar el techo Aseg rate de que tu caja el ctrica y las almohadillas aislantes de goma est n instaladas entre la placa de montaje y la caja el ctrica El ventilador Verifica que todos los tornillos de las aspas y de los brazos de las aspas est n seguros oscila La mayor a de los problemas de oscilaci n del ventilador se deben a que las aspas no est n a un mismo nivel Verifica que est n niveladas seleccionando un punto en el techo sobre la punta de una de las aspas Mide desde un punto en el centro del aspa hasta el punto en el techo Gira el ventilador hasta que la pr xima aspa quede posicionada para medir y mide desde el mismo punto en cada aspa hasta el techo Repite este proceso para cada aspa Las desviaciones de medici n no deben ser mayores a 1 8 plg 3 17 mm Enciende el ventilador durante diez minutos Usa el kit de compensaci n de aspas incluido si sigues notando oscilaci n 14 Preguntas problemas o piezas faltantes Antes de regresar a la tienda llama al Servicio al Cliente de Hampton Bay de Lunes a Viernes entre 8 a m y 6 p m hora Est ndar del Este 1 877 527 0313
4. Preparaci n para el montaje Retira el aro 0 de la cubierta C gir ndolo hacia la derecha hasta soltarlo Retira el soporte de montaje A de la cubierta C aflojando los cuatro tornillos en la parte superior de la cubierta C Quita los dos tornillos sin ranura y afloja los tornillos ranurados Esto te permitir retirar el soporte de montaje Afloja sin quitar los tornillos HH del collar n ubicados en la parte superior del ensamblaje del motor del ventilador E Alinea los orificios en la parte inferior del ensamblaje del tubo bajante bola B con los orificios en el collar n de la parte superior del ensamblaje del motor del ventilador E Inserta con cuidado el pasador de soporte CC a trav s de los orificios del collar n y del ensamblaje del tubo bajante bola B Ten cuidado de no forzar el pasador de soporte CC contra el cableado dentro del ensamblaje del tubo bajante bola B Inserta el pasador de cierre DD en el orificio cercano al extremo del pasador de soporte CC hasta que quede encajado en su posici n Vuelve a apretar los tornillos HH del collar n ubicados en la parte superior del ensamblaje del motor del ventilador E 2 Disposicion de los cables Inserta los cables que salen por la parte superior del motor del ventilador E en la cubierta decorativa del collarin del motor D y a trav s del aro de la cubierta 0 Asegurate de que la
5. batteries included Light kit fitter assembly CFL light bulb 14 Watt maximum IMPORTANT This product and or components are governed by one or more of the following U S Patents 5 947 436 5 988 580 6 010 110 6 046 416 6 210 117 and other patents pending 5 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Installation MOUNTING OPTIONS WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an outlet box marked acceptable for fan support using the screws NOTE You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum angle allowable is 28 away from horizontal provided with the outlet box An outlet box commonly used for the support of lighting fixtures may not be acceptable for fan support and may need to be replaced If in doubt consult a qualified electrician Hanger Bar If your ceiling fan does not have an existing UL listed mounting box then install one using the following instructions Disconnect the power by removing the fuses or turning off the circuit breakers Secure the outlet box directly to the building structure Outlet Box Use the appropriate fasteners and materials The outlet box and its bracing must be able to fully support the weight of the moving fan at least 35 Ibs Do not use a plastic If the canopy C touches the ball downrod assembly B th
6. discreci n reemplazar el producto por un modelo de igual calidad o superior si el producto es devuelto Para obtener un servicio de garant a debe presentar una copia del recibo como comprobante de compra Todos los costos de retiro y reinstalaci n del producto son su responsabilidad Los da os a cualquiera de las piezas como resultado de accidentes instalaci n o uso incorrectos o debidos a la instalaci n de cualquier accesorio no est n cubiertos bajo esta garant a Debido a que las condiciones clim ticas pueden variar esta garant a no cubre ning n cambio en el acabado en bronce incluyendo xido perforaci n corrosi n manchas o descascaramiento Los acabados en bronce de este tipo tienen una vida til m s prolongada cuando se protegen de las condiciones clim ticas cambiantes Es normal cierta oscilaci n y no se considerar una falla Cualquier servicio t cnico realizado por personas no autorizadas invalidar la garant a No hay ninguna otra garant a expresa Mediante la presente Hampton Bay se exime de cualquier garant a incluyendo pero sin limitarse a aquellas de comercializaci n e idoneidad para un fin particular de acuerdo a lo contemplado por la ley La duraci n de cualquier garant a impl cita que no se pueda eximir est limitada al per odo de tiempo especificado en la garant a expl cita Algunos estados no permiten limitaciones en la duraci n de la garant a impl cita por consiguiente la limitaci n anterior
7. el soporte de l mparas podr an no servir como soporte de ventilador y tal vez deban ser reemplazadas En caso de duda consulta a un electricista calificado Barra para Colgar Si tu ventilador de techo no tiene una caja de montaje aprobada por UL inst lala siguiendo las instrucciones a continuaci n Desconecta la energ a retirando los fusibles o apagando los cortacircuitos Fija la caja el ctrica directamente a la estructura del edificio Usa sujetadores y materiales apropiados La caja el ctrica y su t l mpleto del ventilador P EE ala 35 Ib iada ae Si la cubierta C toca el ensamblaje del tubo bajante bola B retira la de pl stico tapa inferior decorativa de la cubierta y gira la cubierta C 180 antes de fijarla a la placa de montaje Caja El ctrica Las ilustraciones a continuaci n muestran tres formas diferentes de montar la caja el ctrica Para colgar el ventilador donde ya haya una l mpara pero ninguna viga de techo tal vez necesites una barra colgante como se muestra anteriormente disponible en cualquier tienda de The Home Depot Caja El ctrica Soporte Placa de Caja El ctrica Montaje Empotrada en Techo Ensamblaje Montaje Est ndar en Techo 3 Como ensamblar el ventilador ADVERTENCIA Si no instalas correctamente el pasador de cierre es posible que el ventilador se afloje y caiga
8. not touch the ceiling Ensure your outlet box is secure and rubber isolator pads were used between the mounting plate and outlet box The fan wobbles Check that all blade and blade arm screws are secure Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure from a point on the center of the blade to the point on the ceiling Rotate the fan until the next blade is positioned for measurement and measure from the same point on each blade to the ceiling Repeat for each blade Any measurement deviation should be within 1 8 in Run the fan for ten minutes Use the enclosed blade balancing kit if the blade wobble is still noticeable 14 Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 877 527 0313 HAMPTONBAY COM Retain this manual for future use Art culo N m 600 520 600 522 Modelo N m 51315 51353 Modelo N m 52 LTM Aprobado por UL GU A DE USO Y MANTENIMIENTO VENTILADOR DE TECHO LATHAM DE 52 PLG 1 32 M Preguntas problemas o piezas faltantes Antes de regresar a la tienda llama al Servicio al Cliente de Hampton Bay de Lunes a Viernes entre 8 a m y 6 p m hora del Este de EE UU 1 877 527 0313 HA
9. puede no aplicarse a su caso El minorista no ser responsable por da os directos indirectos o especiales que resulten o deriven del uso o rendimiento del producto excepto en casos en que lo estipule la ley Algunos estados no permiten la exclusi n o limitaci n de da os directos o indirectos por lo que la limitaci n o exclusi n anterior podr a no aplicarse a su caso Esta garant a le otorga derechos legales espec ficos y es posible que tambi n tenga otros derechos que var an de un estado a otro Esta garant a sustituye todas las garant as anteriores Los costos de env o de cualquier devoluci n de productos hecha como parte de una reclamaci n de garant a est n a cargo del cliente Comun quese con el Equipo de Servicio al Cliente por el 1 877 527 0313 o visite www HamptonBay com Preinstalaci n ESPECIFICACIONES PIES CUB Peso Peso E A 22 7 lb 24 6 Ib 2 1 32 m 1 7 42 67 cm NOTA Estas medidas son aproximadas No incluyen ni el amperaje ni el vataje consumido por el kit de luces HERRAMIENTAS NECESARIAS p gt D Destornillador Sa Destornillador Llave Cinta de Lh a Jn i a Cortacables Phillips plano ajustable electricista Escalera 3 HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Preinstalaci n continuaci n HERRAJES INCLUIDOS A NOTA No se muestra el tama o real de los a si S herrajes eS DD Pieza Descripci n Cantidad Pieza D
10. HAMPTONBAY COM Conserva este manual para usarlo en el futuro
11. Item 600 520 600 522 Model 51315 51353 UL model 52 LTM USE AND CARE GUIDE LATHAM 52 INCH CEILING FAN Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 877 527 0313 HAMPTONBAY COM THANK YOU We appreciate the trust and confidence you have placed in Home Decorators Collection through the purchase of this ceiling fan We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Home Decorators Collection Table of Contents Table Of Content commnnncccnnnnnncccnnnnnaccnnnnn erre 2 Safety Information ocmiosonconescorncconnsannona corso nnndnnnasiancecienen 2 Warranty APA d A 3 Pre Installation isisiiiomasioiossciccarannnnicncccnrnaccnc cn nro canaria nera 3 Installations 6 A O 7 OP Oration PPP A 13 Care and Cleaning coococcccnnnnnnannnanaccncnnnn none 14 TroubleShootiNg lt lt lt occooioisicocionsosrcinananannnencoanirn en rnascinas 14 Safety Information 1 All wiring must be in accordance with the National Electrical Code ANSI NFPA 70 1999 and local electrical codes Electrical installation should be performed by a qualified licensed electrician 2 The outlet box and support structure must be securely mounted and capable of reliably supporting
12. MPTONBAY COM GRACIAS Apreciamos la confianza que has depositado en Home Decorators Collection al comprar este ventilador de techo Nos esforzamos para continuamente crear productos de calidad dise ados para mejorar tu hogar Vis tanos por Internet para ver nuestra l nea completa de productos disponibles para las necesidades de mejoras de tu hogar Gracias por elegir Home Decorators Collection Tabla de Contenido Tabla de Contenido mmmccccnnnncccnnnnnanncnnnnnannccnnnnn erre 2 Informaci n de Seguridad ooonmocccccnnnonnnnnnnnnnnnaanancncnrnnnnnnnnn 2 Ca cc rr 3 PreinsStalaCiOn i cininsioncacinncnnaciccaran naci n rn carr 3 Instalaci ns 6 Ensamblaje Funcionamiento Mantenimiento y Limpieza Soluci n de Problemas Informaci n de Seguridad 1 Todo el cableado debe cumplir con el C digo Nacional de Electricidad ANSI NFPA 70 1999 y con los c digos locales de electricidad La instalaci n el ctrica debe ser hecha por un electricista certificado y calificado 2 Lacaja el ctrica y estructura de soporte deben montarse de forma segura y tener capacidad para sostener de manera confiable un m nimo de 35 Ib 16 kg Usa solamente cajas el ctricas aprobadas por UL marcadas como Para Soporte de Ventilador 3 El ventilador debe ir montado con un m nimo de 7 pies 2 m de separaci n entre el borde trasero de las aspas y el piso 4 No muevas el interruptor de reversa mientras las aspas del ventilador est n en movimien
13. a minimum of 35 Ibs 16 kg Use only UL listed outlet boxes marked For Fan Support 3 The fan must be mounted with a minimum of 7 ft 2 m clearance from the trailing edge of the blades to the floor 4 Do not operate the reversing switch while the fan blades are in motion You must turn the fan off and stop the blades before you reverse the blade direction 5 Do not place objects in the path of the blades 6 Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL Listed and marked suitable for use with the model fan you are installing Switches must be UL General Use Switches Refer to the instructions packaged with the light kits and switches for proper assembly 7 After making electrical connections spliced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box 8 All set screws must be checked and retightened where necessary before installation WARNING To reduce the risk of personal injury do not bend the blade brackets also referred to as flanges during assembly or after installation Do not insert objects in the path of the blades on 2855 35302 2o J orz aaa eon Deal o 25 oO a z5 no k O y o gt Su px g n Osh a0 Fe a Oo ND o oz as WARNING To avoid possib
14. antes de instalar el cableado Si crees que no tienes suficiente experiencia o conocimientos sobre cableado el ctrico contrata a un electricista con licencia ADVERTENCIA Los diagramas el ctricos son solo para referencia Cualquier kit de luces opcional debe estar aprobado por UL y estar marcado como adecuado para ser usado con este ventilador ADVERTENCIA Para disminuir el riesgo de incendio o descarga el ctrica este ventilador s lo debe ser usado con un control de velocidad con el N de pieza FAN 18R fabricado por Chia Wei Electric Co LTD PRECAUCI N Para reducir el riesgo de lesiones f sicas usa s lo los tornillos provistos con la caja el ctrica PRECAUCI N Para evitar lesiones f sicas o da os al ventilador y otros art culos ten cuidado al limpiar o trabajar cerca del ventilador Garant a El proveedor garantiza de por vida a partir de la fecha en que el comprador original lo adquiere que el motor del ventilador no presenta defectos de fabricaci n ni de material al momento en que es enviado desde la f brica El proveedor tambi n garantiza por el per odo de un a o a partir de la fecha de compra por el comprador original que las dem s piezas del ventilador sin incluir ninguna aspa de vidrio o acr lico no presentar n ning n defecto de fabricaci n o de material en el momento de la salida de la f brica Acordamos reparar todos los defectos del tipo antes mencionado sin cargo alguno o a nuestra
15. argas el ctricas Usa solamente un cepillo suave o un pa o sin pelusas para evitar ara ar el acabado El revestimiento est sellado con laca para minimizar la decoloraci n u opacidad Para mayor protecci n y belleza puedes aplicar a la madera una fina capa de pulimento para muebles Cubre los ara azos peque os con una leve aplicaci n de lustrador para calzado El ventilador no necesita lubricaci n El motor tiene cojinetes de bola sellados que est n permanentemente lubricados Soluci n de Problemas AE El ventilador Revisa los fusibles o disyuntores principales y secundarios no enciende Verifica las conexiones de cables en l nea al ventilador y las conexiones de cables del interruptor en la caja de interruptores Revisa la bater a del control remoto Aseg rate de estar en el rango normal de 10 a 20 pies Apaga la electricidad y aseg rate de que coincidan las configuraciones del interruptor en el control remoto y el receptor El ventilador Aseg rate de que los tornillos de la carcasa del motor est n ajustados hace ruido Aseg rate de que los tornillos que unen el soporte de aspa al cuerpo del motor est n bien ajustados Aseg rate de que los empalmes de pl stico no choquen unos con otros o con la pared interior de la caja del interruptor Permite un per odo de 24 horas de adaptaci n La mayor a de los ruidos asociados con un ventilador nuevo desaparecen en ese per odo
16. as del reloj para fijarlo M Am o i 0 0 E mi E Ensamblaje C mo Montar las Aspas del Ventilador 1 0 C mo montar las aspas del ventilador 1 1 C mo montar las aspas ensambladas NOTA Las aspas de tu ventilador son reversibles Elige Coloca el aspa en la carcasa del motor del ventilador E el acabado del aspa que mejor resalte tu decoraci n insertando el aspa dentro de la ranura del lateral de la caja del motor del ventilador E Monta el aspa G al soporte de la misma H y el medall n Inserta el tornillo para soporte BB en el soporte del aspa del aspa I usando los tornillos para montar las aspas AA H Repite el paso con el otro tornillo Monta un tornillo para montar las aspas AA en el soporte Aprieta cada tornillo del soporte BB de forma segura del aspa H Repite el proceso para los dos tornillos de p Repite estos pasos para las aspas restantes G montaje de aspas AA restantes Aprieta cada tornillo para montar las aspas AA de forma segura A 11 HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Ensamblaje C mo Instalar el Kit de L
17. ck wire KK to the receiver NN black wire KK using a plastic wire connecting nut EE Connect the fan motor blue wire JJ to the receiver NN blue wire JJ using a plastic wire connecting nut EE Connect the receiver NN red wire 00 to the supply black hot wire KK using a plastic wire connecting nut EE Connect the receiver NN white wire LL to the supply white wire neutral LL wire using a plastic wire connecting nut EE After connecting the wires spread them apart so that the green Il and white LL wires are one side of the outlet box MM and the black wire KK is on the other side Turn the plastic wire connecting nuts upward and carefully push the wiring into the outlet box MM M_ am o t t 0 KK T H Assembly Attaching the Fan Blades 1 0 Attaching the fan blades 1 1 Attaching the blade assemblies NOTE Your fan blades are reversible Select the blade Attach the blade assembly to the fan motor assembly E by side finish which best accentuates
18. e cables pl stico EE Conecta el cable blanco LL del receptor NN al cable blanco neutro LL de suministro usando un conector de cables pl stico EB Despu s de conectar los cables sep ralos de manera que los cables verde Il y blanco LL queden de un lado de la caja el ctrica MM y el cable negro KK del otro lado Gira las tuercas de conexi n del cable hacia arriba y con cuidado coloca el cableado dentro de la caja el ctrica MM 9 Como montar el ventilador Ensamblaje C mo Colgar el Ventilador continuaci n ADVERTENCIA Cuando uses el ensamblaje del tubo bajante bola est ndar la pesta a en el aro en la parte inferior del soporte de montaje debe encajar en la ranura de la bola de soporte Si la pesta a no se asienta correctamente en la ranura se puede da ar el cableado Alinea las ranuras de cierre de la cubierta C con los dos tornillos del soporte deslizante de montaje A Empuja hacia arriba para enganchar en las ranuras y gira de izquierda a derecha para asegurar la cubierta C en su sitio Ajusta firmemente los dos tornillos de montaje M Instala los dos tornillos de montaje restantes M en los orificios de la cubierta C y aprieta firmemente Instala el aro de cubierta 0 alineando las ranuras del aro con los tornillos en la cubierta C Rota el aro en sentido contrario a las manecill
19. e fan motor aligning the three flat areas on the top flange of the glass assembly E with the black wire from the top of the light bowl J with the three raised dimples in the light kit fitter kit fitter assembly F assembly F Turn the glass bowl J clockwise until it stops Connect the white wire exiting the bottom of the fan motor assembly E with the white wire from the top of the light kit fitter assembly F O Attach the light kit fitter F to the fan motor assembly E by securing them with the two screws N loosened in the first step Push the light kit fitter assembly F up to engage the screw heads in the screw slots and turn to secure Tighten each screw firmly 12 Operation Shut the fan off and wait until the blades have completely stopped before flipping the switch to reverse the direction of your ceiling fan j NOTE The reverse switch is located at the top of motor housing Remote Control Your fan is equipped with a remote control to operate the speed and lights of your new ceiling fan The appropriate speed settings for warm or cool weather depend on factors such as the room size ceiling height and number of fans The fan is shipped from the factory with the reversing switch positioned to circulate air downward If airflow is desired in the opposite direction turn your fan off and wait for the blades to stop turning Slide the reversing switch located at the top of the motor ho
20. e other rights which vary from state to state This warranty supersedes all prior warranties Shipping costs for any return of product as part of a claim on the warranty must be paid by the customer Contact the Customer Service Team at 1 877 527 0313 or visit www HamptonBay com Pre Installation SPECIFICATIONS Pe ow oe To es ccc 22 7 Ibs 24 6 Ibs Medium 1 i 3704 osko 11 2kg OIE NOTE These are approximate measures They do not include the amps and wattage used by the light kit U L TOOLS REQUIRED W Flat blade Adjustable Electrical A screwdriver wrench O tape Step ladder Philips screwdriver 3 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Pre Installation continued HARDWARE INCLUDED A NOTE Hardware not shown to actual size aL Sy gt _ Part Description Guamiy Part Description Quantity Ak Blade attachment screws Do Locking in DD Blade bracket screw with lockwasher E Plastic wire connecting nut FE Balancing ki Pre Installation continued PACKAGE CONTENTS Quantity Part Description Quantity Ball downrod assembly l Blade medallion Oo 5 O C canopy with canopy ring ata E Slide on mounting bracket i 6 Blade CT 5 inside canopy PH Blade bracket Decorative motor collar cover Remote control receiver Fan motor assembly
21. en remove outlet box The illustrations below show three different ways to mount the the decorative canopy bottom cover and turn he canopy y 100 outlet box before attaching the canopy C to the mounting plate To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown above available at any Home Depot store de Outlet Box Provide Strong Support Ceiling Mounting Plate Recessed Outlet Box Assembly Standard Ceiling Mount 1 Preparing for mounting Remove the canopy ring 0 from the canopy C by turning the ring to the right until it unlocks Remove the mounting bracket A from the canopy C by loosening the four screws on the top of the canopy C Remove the two non slotted screws and loosen the slotted screws This will enable you to remove the mounting bracket 3 Assembling the fan WARNING Failure to properly install the locking pin could result in the fan becoming loose and possibly falling Loosen but do not remove the setscrew HH on the collar on top of the fan motor assembly E Align the holes at the bottom of the ball downrod assembly B with the holes in the collar on top of the fan motor assembly E Carefully insert the hanger pin CC through the holes in the collar and ball downrod assembly B Be careful not to jam the hanger pin CC against the wiring inside the ball d
22. escripci n Cantidad m iio paa ermene ceases e penseis Tornillo adicional para soporte de 11 Tuerca de pl stico para conectar aspas con contratuerca cables ce Pasador de soporte FF Kit de compensaci n Preinstalaci n continuaci n CONTENIDO DEL PAQUETE Cantidad Pieza Descripci n Cantos DCI CON ENT dentro de Ia cubierta a foore i 1 meann c ubiera decorativa el cotar dermo 1 bater as incluidas Ensamblaje del motor del ventilador Ensamblado del soporte del kit de luces Bombilla CFL m ximo de 14 W IMPORTANTE Este producto y o sus componentes est n protegidos por una o m s de las siguientes patentes de los EE UU 5 947 436 5 988 580 6 010 110 6 046 416 6 210 117 y otras patentes pendientes 5 HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Instalaci n OPCIONES DE MONTAJE NOTA Tal vez necesites un tubo bajante m s largo para mantener la altura m nima adecuada de las aspas al ADVERTENCIA Para disminuir el riesgo de incendio descarga el ctrica o lesiones f sicas instala el ventilador conectado a una caja el ctrica marcada como aprobada para el soporte de ventilador y usa instalar el ventilador en un techo inclinado El ngulo m ximo permitido es de 28 de la posici n horizontal los tornillos de montaje incluidos con esta Las cajas el ctricas utilizadas com nmente para
23. iba Instala una bater a de 9 V incluida en el control remoto Coloca de nuevo la cubierta en el control remoto Para configurar el c digo del receptor Desliza los interruptores de c digo hacia la misma posici n que elegiste para el control remoto Modelo del Controlador FAN 18R D EEE g itl o hacia abajo Las configuraciones de f brica son hacia arriba C mo instalar el receptor ADVERTENCIA Para reducir el riesgo de incendio o de descarga el ctrica recuerda desconectar la electricidad El cableado el ctrico debe cumplir todos los requisitos del c digo nacional de electricidad y los c digos locales de electricidad Las fuentes de energ a y el ventilador deben ser de 110 120 V y 60 Hz PRECAUCI N Si otros cables del ventilador son de color diferente un electricista certificado deber instalar esta unidad arriba y perpendicular al soporte de montaje A el lado derecho el ensamblaje del tubo bajante bola B HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Coloca el control remoto receptor K con el lado plano hacia Ubica los cables de suministro en el lado izquierdo del soporte de montaje deslizante A y coloca los cables del ventilador en Inserta parcialmente el receptor del control remoto K con el lado plano hacia arriba hasta que un extremo descanse sobre
24. jados en el primer paso Empuja el ensamblado del kit de luces F hasta enganchar las cabezas de los tornillos en las ranuras y g ralo para fijarlo Aprieta firmemente todos los tornillos 12 Funcionamiento Clima c lido Hacia adelante Un flujo de aire hacia abajo crea un la carcasa del motor Apaga el ventilador y espera hasta que las efecto refrescante Esto te permite fijar tu aire acondicionado a una aspas se hayan detenido completamente antes de presionar el temperatura m s alta sin afectar tu comodidad interruptor para invertir la direcci n de tu ventilador de techo j NOTA El interruptor de reversa est ubicado en la superficie de Control Remoto Tu ventilador est equipado con un control Ml remoto que controla la velocidad y las luces de tu ventilador de techo Las configuraciones de velocidad para clima c lido o fr o dependen de factores como el tama o de la habitaci n la altura del techo y la cantidad de ventiladores Este ventilador se env a desde la f brica con el interruptor de reversa posicionado para hacer circular el aire hacia abajo Si deseas dirigir la corriente de aire en la direcci n contraria apaga el ventilador y espera que las aspas se detengan Desliza el interruptor de reversa ubicado en la caja de interruptores hacia la direcci n opuesta y luego vuelve a prender el ventilador Las aspas del ventilador girar n en sentido contrario y re
25. le electrical shock turn the electricity off at the main fuse box before wiring If you feel you do not have enough electrical wiring knowledge or experience contact a licensed electrician WARNING Electrical diagrams are for reference only Optional use of any light kit shall be UL listed and marked suitable for use with this fan WARNING To reduce the risk of fire or electric shock this fan should only be used with fan speed control part no FAN 18R manufactured by Chia Wei Electric Co LTD CAUTION To reduce the risk of personal injury use only the screws provided with the outlet box CAUTION To avoid personal injury or damage to the fan and other items use caution when working around or cleaning the fan Warranty The supplier warrants the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a life time after the date of purchase by the original purchaser The supplier also warrants that all other fan parts excluding any glass or acrylic blades to be free from defects in workmanship and material at the time of shipment from the factory for a period of one year after the date of purchase by the original purchaser We agree to correct such defects without charge or at our option replace with a comparable or superior model if the product is returned To obtain warranty service you must present a copy of the receipt as proof of purchase All costs of rem
26. od mounting the accept up to one 12 gauge house wire and two wires from the tab in the ring at the bottom of the mounting bracket must rest in fan If you have larger than 12 gauge house wiring or more than the groove of the hanger ball Failure to properly seat the tab in one house wire to connect to the fan wiring consult an electrician the groove could cause damage to the wiring for the proper size wire nuts to use IMPORTANT Use the plastic wire connecting nuts EE supplied with AONE locking slats at ine candy Cvita WO SETEWE your fan and remote control Secure the connectors with electrical in the slide on mounting bracket A Push up to engage the tape and ensure there are no loose strands or connections slots and turn clockwise to lock the canopy C in place Firmly tighten the two mounting screws M Install the remaining two mounting screws M into the holes in the canopy C and tighten firmly Install the canopy ring 0 by aligning the ring s slots with the screws in the canopy C Rotate the ring counter clock wise to lock it in place Connect the ground conductor of the 120 Volt supply this may be a bare wire or a wire with green colored insulation to the green ground lead s Il of the fan using a wire connecting nut EE Connect the fan motor white wire LL to the receiver NN white wire LL using a plastic wire connecting nut EE Connect the fan motor bla
27. oving and reinstalling the product are your responsibility Damage to any part such as by accident or misuse or improper installation or by affixing any accessories is not covered by this warranty Because of varying climatic conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by unauthorized persons shall render the warranty invalid There is no other express warranty Hampton Bay hereby disclaims any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty Some states do not allow a limitation on how long an implied war ranty lasts so the above limitation may not apply to you The retailer shall not be liable for incidental consequential or special damages arising out of or in connection with product use or performance except as may otherwise be accorded by law Some states do not allow the exclusion of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives specific legal rights and you may also hav
28. ownrod assembly B Insert the locking pin DD through the hole near the end of the hanger pin CC until it snaps into its locked position Re tighten the setscrew HH on the collar on top of the fan motor assembly E 2 Routing the wires Route the wires exiting the top of the fan motor E into the decorative motor collar cover D and through the canopy ring 0 Make sure the slot openings are on top and route the wires through the canopy C and then through the ball downrod assembly B HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Assembly Hanging the Fan Attaching the fan to the electrical 5 Hanging the fan box WARNING To reduce the risk of fire electric shock Carefully lift the fan motor assembly E up to the slide on or other personal injury mount the fan to an outlet box or supporting system marked acceptable for fan mounting bracket A support and use the mounting screws provided with Seat the hanger ball portion of the ball downrod assembly B e owi iw in the mounting bracket socket Ensure that the tab on the slide on mounting bracket A socket is properly seated in the groove in the hanger ball Pass the 120 Volt supply wires through the center hole in the slide on mounting bracket A Install the ceiling mounting bracket on the outlet box by slid
29. r or the wood or possibly cause an electrical shock Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed with a lacquer to minimize discoloration or tarnishing You can apply a light coat of furniture polish to the wood for additional protection and enhanced beauty Cover small scratches with a light application of shoe polish You do not need to oil your fan The motor has permanently lubricated sealed ball bearings Troubleshooting Problem SAR ss The fan will not start Check the main and branch circuit fuses or breakers Check the line wire connections to the fan and switch wire connections in the switch housing Check the battery in the remote control Ensure you are in the normal range of 10 20 feet Turn the power off and ensure that the dip switch settings are the same on the remote control and receiver The fan is noisy Ensure all motor housing screws are snug Ensure the screws that attach the fan blade bracket to the motor hub are tight Ensure the wire nut connections are not rattling against each other or the interior wall of the switch housing Allow a 24 hour breaking in period Most noises associated with a new fan disappear during this time If you are using the ceiling fan light kit ensure the screws securing the glassware are tight Check that the light bulbs are also secure Ensure the canopy is a short distance from the ceiling It should
30. s ranuras est n en la parte superior y pasa los cables a trav s de la cubierta C y luego a trav s del ensamblaje del tubo bajante bola B HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Ensamblaje C mo Colgar el Ventilador C mo instalar el ventilador en la 5 caja el ctrica ADVERTENCIA Para reducir el riesgo de incendio descarga el ctrica o lesiones f sicas s lo instala el C mo colgar el ventilador Con cuidado alza el ensamblaje del motor del ventilador E ventilador en una caja el ctrica o sistema de soporte hasta el soporte de montaje deslizante A aprobados para ventiladores y usa los tornillos de Coloca la bola de soporte del ensamblaje del tubo bajante montaje que vienen con la caja el ctrica bola B en el soporte de montaje Aseg rate de que la pesta a sobre el soporte de montaje deslizante A encaje bien dentro de la ranura de la bola de soporte Pasa los cables de suministro de 120 Voltios a trav s del orificio central en el soporte de montaje deslizante A Instala el soporte de montaje de techo sobre la caja el ctrica desli
31. to Debes apagar el ventilador y detener las aspas antes de invertir la direcci n de las aspas 5 No coloques objetos en la trayectoria de las aspas 6 Los diagramas el ctricos son solo para referencia Los kits de luces no empaquetados con el ventilador deben estar aprobados por UL y marcados como apropiados para ser usados con el modelo de ventilador a instalar Los interruptores deber n estar clasificados por UL como de Uso General Consulta las instrucciones adjuntas a los kits de luces e interruptores para obtener informaci n sobre el montaje adecuado 7 Despu s de hacer las conexiones el ctricas debes voltear los conductores empalmados hacia arriba y meterlos con cuidado en la caja el ctrica Los cables deben estar separados con el cable a tierra y el conductor a tierra del equipo en uno de los lados de la caja el ctrica 8 Todos los tornillos colocados se deben verificar y ajustar donde sea necesario antes de la instalaci n ADVERTENCIA Para reducir el riesgo de lesiones personales no dobles los soportes de las aspas tambi n llamados bridas durante o despu s de la instalaci n No coloques objetos en la trayectoria de las aspas ADVERTENCIA Para reducir el riesgo de incendio o descarga el ctrica no utilices este ventilador con ning n dispositivo de control de velocidad de estado s lido ADVERTENCIA Para evitar una posible descarga el ctrica apaga la electricidad en la caja principal de fusibles
32. trician To prevent possible interference from or to other remote units such as garage door openers car alarms or security systems Position the remote control receiver K flat side up and per change the combination code but be sure that the code on pendicular to the slide on mounting bracket A both the hand held transmitter and receiver in the fan are the Position the supply wires to the left side of the slide on mount Se ing bracket A and position the fan wires to the right side Partially insert the remote control receiver K flat side up until one end rests on the ball downrod assembly B To set the code on the remote control Remove the battery cover by pressing firmly on the arrow and sliding the cover off Slide the code switches to your choice of either up or down The factory setting is up Install a 9 V battery included into the remote control Replace the battery cover on the remote control To set the code on the receiver Slide the code switches to the same position as set on your remote control Controller Model FAN 18R Ieee g tN 9 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Assembly Hanging the Fan continued 8 Making the electrical connection 8 Mounting the fan WARNING Each wire nut supplied with this fan is designed to WARNING When using the standard ball downr
33. uces 1 2 Como instalar el kit de luces 1 3 Como instalar las bombillas PRECAUCION Para disminuir el riesgo de descarga ADVERTENCIA No apretar demasiado al instalar la pantalla de el ctrica desconecta el circuito de energia del ventilador A vidrio en el ensamblado del kit de luces Espera que la pantalla antes de instalar el kit de luces de vidrio se enfrie completamente antes de retirarla Quita un tornillo N del soporte negro debajo del ensamblado Con la electricidad apagada instala las bombillas L de 40 V del motor del ventilador E Afloja pero no quites los otros dos maximo incluidas enroscandolas en los portabombillas tornillos Coloca la pantalla de vidrio J en el soporte del kit de luces Conecta el cable azul que sobresale por debajo del ensamblado F alineando las tres reas planas en el reborde superior del motor del ventilador E con el cable negro de la parte de la pantalla de vidrio J con las tres muescas salientes superior del ensamblado del soporte del kit de luces F del kit de luces F Gira la pantalla de vidrio J de izquierda a derecha hasta que se detenga Conecta el cable blanco que sobresale por debajo del ensamblado del motor del ventilador E con el cable blanco de la parte superior del ensamblado del soporte del kit de luces F O Monta el ensamblado del kit de luces F en el ensamblado del motor del ventilador E y f jalo con los dos tornillos N aflo
34. using to the opposite position and turn the fan on again The fan blades will turn in the opposite direction and reverse the airflow 1 Speed The remote features Low Med Hi and Off buttons to select the desired speed of operation and turn the fan On or Off 2 Light To control the light kit the remote features a Light Dimmer button Operating the fan High button High speed Medium button Medium speed Low button Low speed Off button Power off Light Dimmer Dims light with memory 13 Warm weather Forward A downward airflow creates a cooling ef fect This allows you to set your air conditioner on a warmer setting without affecting your comfort Cool weather Reverse An upward airflow moves warm air off of the ceiling This allows you to set your heating unit on a cooler set ting without affecting your comfort HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Care and Cleaning A WARNING Make sure the power is off before cleaning your fan Because of the fan s natural movement some connections may become loose Check the support connections brackets and blade attachments twice a year Make sure they are secure It is not necessary to remove the fan from the ceiling Clean your fan periodically to help maintain its new appearance over the years Do not use water when cleaning as this could damage the moto
35. vertir n la direcci n de la corriente de aire 1 Velocidad El control remoto tiene teclas de Bajo Medio Alto y Apagado para seleccionar la velocidad de funcionamiento deseada y para apagar o encender el ventilador Clima fr o Reversa Un flujo de aire hacia arriba mueve el aire c lido lejos del techo Esto te permite fijar tu unidad de calefacci n a una temperatura m s baja sin afectar tu comodidad 2 Luces Para controlar el kit de luces el control remoto tiene un bot n para Luces Regulador de Intensidad C mo poner en funcionamiento el ventilador Bot n alto Velocidad alta Bot n medio Velocidad media Bot n bajo Velocidad baja Bot n de apagado Se apaga Bot n del regulador de luces Regula la luz y recuerda el nivel anterior de intensidad de la luz 13 HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Mantenimiento y Limpieza A ADVERTENCIA Aseg rate de que la corriente est apagada antes de limpiar el ventilador Debido al movimiento natural del ventilador algunas conexiones pueden aflojarse Revisa las conexiones de soporte los soportes y los accesorios de las aspas dos veces al a o Verifica que est n seguros No es necesario desmontar el ventilador del techo Limpia el ventilador con frecuencia para que luzca como nuevo con el pasar de los a os No uses agua al limpiar ya que esto puede da ar el motor o la madera o puede causar desc
36. your decor first inserting the blade assembly into the slot in the side of the fan motor assembly E Attach the blade G to the blade bracket H and the blade Insert a blade bracket screw with lockwasher BB into the medallion I using the blade attachment screws AA Start blade bracket H Repeat for the one remaining screw a blade attachment screw AA into the blade bracket H Tighten each blade bracket screw with lockwasher BB Repeat for the two remaining blade attachment screws AA securely Tighten each blade attachment screw AA securely Repeat these steps for the remaining blades G L AA 11 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Assembly Attaching the Light Kit 1 2 Attaching the light kit 1 3 Installing the light bulbs CAUTION To reduce the risk of electric shock disconnect WARNING Do not overtighten when installing the glass shade the electrical supply circuit to the fan before installing the A into the light kit assembly Allow the glass shade to cool light kit completely before removing Remove one screw N from the black bracket below the With the power off install the light bulbs L Max 14W fan motor assembly E Loosen but do not remove the provided into the light bulb sockets other two screws Place the glass bowl J into the light kit fitter assembly F Connect the blue wire exiting the bottom of th
37. zando el soporte de montaje A sobre los dos tornillos UU 9 A suministrados con la caja el ctrica Si es necesario usa arandelas niveladoras no incluidas entre el soporte de montaje deslizante i A y la caja el ctrica F jate que el lado plano del soporte de 0 montaje A est hacia la caja el ctrica Ajusta firmemente los dos tornillos de montaje UU c D l E Ensamblaje C mo Colgar el Ventilador continuaci n Configurar los c digos del control remoto NOTA Las frecuencias del receptor y control remoto han sido preconfiguradas en la f brica Antes de instalar el receptor aseg rate de que los interruptores en el transmisor y del control remoto est n configurados en la misma frecuencia Los interruptores en el transmisor del control remoto est n ubicados dentro del compartimento de la bater a NOTA Este control remoto est equipado con 16 combinaciones de c digos Para evitar posibles interferencias desde o hacia otras unidades de control remoto como los abrepuertas de garajes alarmas de autos o sistemas de seguridad cambia el c digo de combinaci n pero aseg rate de que el c digo del transmisor de mano y el del receptor del ventilador sean iguales Para configurar el c digo del control remoto Quita la cubierta de la bater a presionando con firmeza en la flecha y deslizando la cubierta hasta soltarla Desliza los interruptores de c digo seg n tu elecci n hacia arr

Download Pdf Manuals

image

Related Search

Related Contents

Galerie manual PDF  Behringer PMP2000 User's Manual  Philips SHAVER 8000 8250XL Electric razor  Origin Storage 1TB TLC SATA 2.5"    Oce 3000 User Manual - Océ  Nilfisk-ALTO ATS 46/53 User's Manual  AplusCase CS-Black Pearl II  

Copyright © All rights reserved.
Failed to retrieve file