Home
Hampton Bay 14922 Instructions / Assembly
Contents
1. Make sure your ceiling box is secure and rubber isolator pads are used between mounting bracket and outlet box 1 This unit is equipped with a wattage limiting device Lamping in excess of 190 watts will disable your ceiling fan s light kit To reset your light kit you must turn the power offand relamp keeping the wattage under 190 watts Restore power to your ceiling fan and continue normal operation 1 Do not connect the fan with a wall mounted variable speed control s 2 Make sure the dip switches are set correctly WARNING MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU ATTEMPY ANY REPAIRS REFER TO THE SECTION MAKING ELECTRICAL CONNECTIONS oO XD GO KR WOW NS 10 Specifications FAN SIZE SPEED VOLTS AMPS WATTS RPM CFM 8 84kgs 19 45 lbs These are approximate measures They do not include Amps and Wattage used by the light kit Distributed by Home Depot U S A Inc 2455 Paces Ferry Rd N W Atlanta GA 30339 11 10 08kgs 22 18 lbs Lifetime Limited Warranty lifetime warranty on motor The Hampton Bay warrants the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a period of lifetime after the date of purchase by the original purchaser Hampton Bay also warrants that all other fan parts excluding any glass or acrylic blades to be free from defects in workmanship and material a
2. should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 11 All set screws must be checked and retightened where necessary before installation WARNING TO REDUCE THE RISK OF PERSONAL INJURY DO NOT BEND THE BLADE ARMS ALSO REFERRED TO AS FLANGES WHEN INSTALLING THE BRACKETS BALANCING THE BLADES OR CLEANING THE FAN DO NOT INSERT FOREIGN OBJECTS IN BETWEEN ROTATING FAN BLADES WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY MOUNT FAN TO OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT WITH THE SCREWS PROVIDED WITH THE OUTLET BOX ATTENTION FAN INCLUDES A 190W LIMITER TO COMPLY WITH THE DEPARTMENT OF ENERGY 2009 REGULATION LAMPING THIS PRODUCT OVER 190W WILL CAUSE THIS FAN TO NOT LIGHT PLEASE USE BULBS WITHA TOTAL WATTAGE UNDER THE 190W REGULATION o Unp ackin O Your Fan Unpack your fan and check the contents You should have the following items Unpack your fan and check the contents You should have the following items Loose parts bag containing A Mounting hardwar 1 Set of blades 5 9 Flywheel 1 Plastic es de aan 3pcs 2 Hanger bracket 1 10 Lightkit 1 3 Canopy 1 11 40 Watt E12 bulb 3 B Blade attachment hardw
3. 750 809 Springview 52 in Ceiling Fan Owner s Manual Springview Ventilador de Techo de 1 32 m q us Manual del Propietario Intertek ISTED ongratulations on your purchase of a Hampton Bay ceiling fan Your new fan will be a beautiful addition to your home and will keep you comfortable throughout the year The Hampton Bay Fan Company offers a wide variety of ceiling fans We offer combinations of wood and brass finishes solid designer colors and our unique glass and crystal designs A large selection of light fixtures and light kits is also available Ask your dealer about other accessories that will allow you to further customize your fan We re certain that your Hampton Bay fan will provide you with many years of comfort energy savings and satisfaction To ensure your personal safety and to maximize the performance of your fan please read this manual thoroughly Springview by Hampton Bay Thank you for purchasing our ceiling fan This product has been 5 2 S p rin oview manufactured with the highest standards of safety and quality Ceiling Fan by Hampton Bay Date Purchased Table of Contents Store Purchased Safety Rules es saruri eunn ndane 1 ETL Model No 750809 Unpacking Your Fan 2 Installing Your Fan 3 Serial No Installing the Light Kit 8 OperatingYour Fan 9 Care of Your Fan 10 Vendor No 445993 Trouble
4. are 4 Canopy cover 1 12 Glass shade 1 3 16 x6mm Screw 16pcs 5 Ball downrod assembly 1 Fiber washer 16pcs 6 Coupling cover 1 C Blade bracket hardware 7 Fan motor assembly 1 1 4 9 5mm screws 10pcs 8 Set of blades brackets 5 Flywheel hardware 1 4 9 5mm screws 6pcs Extra plug with nut 1 Pull chain fob 2pcs Balancing kit 1 WARNING DO NOT INSTALL OR USE FAN mo IF ANY PART IS DAMAGED OR MISSING CALL TOLL FREE 1 800 527 0998 Installing Your Fan Tools Required Phillips screwdriver straight slot screwdriver step ladder and wire cutters PA Y Mounting Options If there isn t an existing UL listed mounting box then read the following instructions Disconnect the power by removing fuses or turning off circuit breakers Secure the outlet box directly to the building structure Use appropriate fasteners and building materials The outlet box and its support must be able to fully support the moving weight of the fan at least 35 lbs Do not use plastic outlet boxes WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY MOUNT FAN ONLY TO AN OULET BOX MARKED ACCEPT ABLE FOR FAN SUPPORT AND USE THE MOUNTING SCREWS PROVIDED WITH THE OULET BOX OUTLET BOX COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURE MAY NOT BE ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED CONSULTA QUALIFIED ELECTRICIAN IF IN DOUBT Figures 1 3 are examples of different way
5. as follows 1 pull High 2 pulls Medium 3 pulls Low and 4 pulls Off Speed settings for warm or cool weather depend on factors such as the room size ceiling height number of fans and so on 2 Light kit pull chain it controls the light kit in ON or OFF The slide switch controls directions forward switch left or reverse switch right Warm weather Counter Clockwise direction A downward air flow creates a cooling effect Fig 21 This allows you to set your air conditioner on a higher setting without affecting your comfort Cool weather Clockwise direction An upward airflow moves warm air off the ceiling area Fig 22 This allows you to set your heating unit on a lower setting without affecting your comfort Figure 22 Care of Your Fan Troubleshooting Here are some suggestions to help you maintain your fan PROBLEM 1 Because of the fan s natural movement some illa connections may become loose Check the support connections brackets and blade attachments twice a year Make sure they are secure Itis not necessary to remove fan from ceiling 2 Clean your fan periodically to help maintain its new appearance over the years Do not use water when cleaning Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed with a lacquer to minimize discoloration or tarnishing Do not use water when cleaning This could damage t
6. d Figure 9 Carefully reinstall hanger ball onto tod being sure that cross pin is in correct position set screws are tighten and wires are not twisted 6 Now lift motor assembly into position and place hanger ball into hanger bracket Rotate until the check groove drops into the registration slot and seats firmly Figure 10 Downrod should not rotate if this is done correctly Outlet box Set screws Hanger bracket Figure 5 Figure 6 seine Cross pin Downe J Hanger Ny ball Supply gt wires Figure 7 Figure 8 Figure 9 4 Lead Wires dz Ball Downrod Assembly 4 Canopy Split Pin Registration Figure 10 Making the Electrical Connections Remember to shut off the power Follow the steps below to connect the fan to your household wiring Use the wire connecting nuts supplied with your fan Secure the connectors with electrical tape 1 Connect the fan supply black wire and light supply blue wire to the black household supply wire Figure 11 2 Connect the neutral fan white wire tothe white neutral household wire Figure 11 3 Connect the fan ground wire green to the household ground wire Figure 11 4 After connecting the wires spread them apart so that the green and white wires are on one side of the outlet box and the black and the blue wires are on the other side 5 Turn the connecting nuts upward and push the wirin
7. g into the outlet box Figures 12 and Figures 13 illustrate the wiring connections for optional wall control available at your Hampton Bay Retailer the wire color out of wall control may vary see wall control s installation manual for correct wire connections NOTE LIGHT KITS ARE AVAILABLE AT YOU HAMPTON BAY RETAILER THE FAN IS ALREADY WIRED TO SUPPORT THE LIGHT KIT OPTION WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR OTHER PERSONAL INJURY MOUNT FAN ONLY ON AN OUTLET BOX OR SUPPORTING SYSTEM MARKED ACCEPTABLE FOR FAN SUPPORT TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE SUPPLY CIRCUIT Ground Conductor WHITE Outlet Box Green Ground Lead Zz lu lu a o Ground to Downrod Diagram indicates optional light kit wiring Figure 11 Finishing the Installation 1 Tuck connections neatly into ceiling outlet box 2 Remove one screw from the hanger bracket and loosen the other screw around 1 4 Outlet Box QUe Box 3 Align the canopy up to ceiling and over the loose screw Place the canopy into key hole and rotate SUPPLY GIRGUIT SUPPLY CIRCUIT Ground Conductor l w E I Conductor Light Switch Green A 4 Green canopy clockwise Figure 14 r Lead 4 Secure the canopy by use previous removed screw x o 5 Place the canopy cover t
8. he motor or the wood or possibly cause an electrical shock 3 You can apply a light coat of furniture polish to the wood blades for additional protection and enhanced beauty Cover small scratches with a light application of shoe polish Lights shut off and 4 There is no need to oil your fan The motor has will not come back permanently lubricated sealed ball on bearings 1 2 3 4 For any additional information on your Hampton Bay Ceiling Fan please write to THE HAMPTON BAY FAN amp LIGHTING CO P O Box 395 Norco CA 92860 CALL TOLL FREE 1 800 527 0998 Fan sounds noisy Remote control SOLUTION 1 Check main and branch circuit fuses or breakers 2 Check line wire connections to the fan and switch wire connections in the switch housing Check to make sure the dip switches from the transmitter and receiver are set to the same frequency Make sure all motor housing screws are snug Make sure the screws that attach the fan blade bracket to the motor hub is tight Make sure wire nut connections are not rattling against each other or the interior wall of the switch housing Allow a 24 hour breaking in period Most noises associated with a new fan disappear during this time Ifusing ceiling fan light kit make sure the screws securing the glassware are tight Check that the light bulb is also secure Make sure there is a short distance from the ceiling to the canopy It should not touch the ceiling
9. hing ceiling Blade balancing The following procedure should correct most fan wobble Check after each step Figure 18 1 Check that all blades and blade holder screws are secure 2 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance as shown in Figure 18 Rotate the fan until the next blade is positioned for measurement Repeat for each blade The distance should be equal within 1 8 Run the fan for 10 Minutes 3 Use the enclosed Blade Balancing Kit if the blade wobble is still noticeable Installing the light kit REMEMBER to disconnect the power The fan blades must already be attached to the fan Your fan and light kit though pre wired have been disassembled at the factory to ease in shipping Please follow these steps to complete the installation of your fan and light TO REDUCE THE RISK OF FIRE DO NOT EXCEED MAXIMUM WATTAGE RATING ATTENTION The Energy Policy Act of 2005 requires this fan to be equipped with a 190 watt limiting device If lamping exceeds 190 watts the ceiling fan s light kit will shut off automatically 1 Remove 1 of 3 screws on the mounting ring and loosen other 2 screws Do not remove 2 Remove the mounting plate from the light kit by removing 3 screws Keep them for future use 3 Place the key holes on the mounting plate over the 2 screws
10. l not be liable for incidental consequential or special damages arising out of or in connection with product use or performance except as may otherwise be accorded by law Some states do not allow the exclusion of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties Shipping costs for any return of product as part of a claim on the warranty must be paid by the customer You must present a copy of the original purchase receipt to obtain warranty service For any additional information on your Hampton Bay Ceiling Fan please write to THE HAMPTON BAY FAN amp LIGHTING CO P O Box 395 Norco CA 92860 Attach receipt here for easy location 12
11. o the canopy and rotate Ground to Ground to j TENEN a Downrod Downrod canopy cover clockwise until it is locked into right position Figure 14 WARNING MAKE SURE TAB AT BOTTOM OF HANGER BRACKET IS PROPERLY SEATED IN GROOVE OF HANGER BALL BEFORE ATTACHING CANOPY TO BRACKET ILURE TO PROPERLY SEAT TAB IN GROOVE COULD CAUSE DAMAGE TO ELECTRICAL WIRING Outlet box gt Mounting ___ bracket Lead Wires A Ball Downrod Assembly Diagram indicates optional light kit wiring Diagram indicates optional light kit wiring Canopy Figure 12 Figure 13 Screw gt K t ee S cover Figure 14 Attaching the Fan Blades 1 Attach the fan blades to the blade holders by using three screws and fiber washers as shown in Figure 15 Start a screw into the blade holder do not tighten Repeat for the 2 remaining screws and washers 2 Tighten each screw securely starting with the center screw 3 Fasten the blade assemblies to fly wheel with the fly wheel hardware provided Figure 16 Screws _ gt Fiber _p Washer holder Figure 15 Screw Blade Bracket Fly wheel Figure 16 Figure 17 Installing the fly wheel Loose five set motor screws on the motor Place the slot holes of the fly wheel over five screws previously loosened and attach five motor screws provided in Loose parts bag tighten all screws Figure 17 Touc
12. previously loosened from the mounting ring turn mounting plate until it locks in place at the narrow section of the key holes Secure by tightening the 2 screws previously loosened and the one previously removed Figure 19 4 Connect the connectors from the light kit and fan Figure 19 5 Lift the light kit to the mounting plate align the key holes and tighten 3 screws previously removed 6 Place the 3 bulbs 40 Watt included into the Light kits Figure 20 7 Remove the two washers metal nut metal cap and final from the light kit 8 Install the glass shade along with 2 washers previously removed twist with the metal nut install the metal cap then twist the finial securely Figure 20 9 Restore power and your ceiling fan is ready for operations NOTE LIGHT BULB HAVE NO WARRANTY CAN BE PURCHASED AT LOCAL LIGHT BULB SPECIALTY STORE OR FROM OUR SERVICE CENTER i Sor ring Mounting plate gt 222 Screws 4 Y Screws Je Connection Plugs Reverse switch Light Kit Rubber Washer S n Metal Nut Metal Washer Glass shade lt Metal Cap x Finial 9 Figure 20 Operating your fan NOTE WAIT FOR FAN TO STOP BEFORE CHANGING THE SETTING OF THE SLIDE SWITCH Turn on the power and check the operation of your fan There are three pull chains available in your fan 1 3 speed Pull chain it controls the fan speed
13. s to mount the outlet box Outlet Box Figure 1 Outlet Box Figure 2 Provide Strong lt Support Recessed Outlet Box Ceiling Mounting Plate Figure 3 Note You may need a longer downrod to maintain proper blade clearance when installing ona steep sloped ceiling The maximum angle allowable is 18 If the canopy touches downrod remove the decorative canopy bottom cover and turn the canopy 180 before attaching the canopy to the mounting plate eT Outlet Box Figure 4 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 available at any Home Depot store Hanging the Fan REMEMBER to turn off the power Follow the steps below to hang your fan properly 1 Secure the hanger bracket to the ceiling outlet box with the screws and washers provided with your outlet box Figure 5 2 Remove the hitch pin and lock pin from the downrod assembly Loosen the two set screws from the motor assembly Figure 6 3 Remove hanger ball from downrod assembly by loosening set screw removing the cross pin and sliding ball off rod Figure7 4 Carefully feed fan wires up through the downrod Figure 8 Thread the rod into the coupling Next line up holes and replace lock pin and hitch pin Tighten set screws 5 Slip coupling cover canopy cover and canopy onto downro
14. shooting 10 Specifications 11 718212149225 UPC ATAR Warrantylnformation 12 Safety Rules Read and To reduce the risk of electric shock insure electricity has been turned off at the circuit breaker or fuse box before beginning All wiring must be in accordance with the National Electrical Code ANSI NFPA 70 1999 and local electrical codes Electrical installation should be performed by a qualified licensed electrician WARNING To reduce the risk of electrical shock or fire do not use this fan with any solid state fan speed control device It will permanently damage the electronic circuitry CAUTION To reduce the risk of personal injury use only the screws provided with the outlet box The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 pounds Use only UL Listed outlet boxes marked FOR FAN SUPPORT The fan must be mounted with a minimum of 7 feet clearance from the trailing edge of the blades to the floor Avoid placing objects in path of the blades To avoid personal injury or damage to the fan and other items be cautious when working around or cleaning the fan Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning Save These Instructions 10 After making electrical connections spliced conductors
15. t the time of shipment from the factory for a period of one year after the date of purchase by the original purchaser We agree to correct such defects without charge or at our option replace with a comparable or superior model if the product is returned to Hampton Bay To obtain warranty service you must present a copy of the receipt as proof of purchase All costs of removing and reinstalling the product are your responsibility Damage to any part such as by accident or misuse or improper installation or by affixing any accessories is not covered by this warranty Because of varying climatic conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by unauthorized persons shall render the warranty invalid There is no other express warranty Hampton Bay hereby disclaims any and all warranties including but not limited to Those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you The retailer shal
Download Pdf Manuals