1. Hunter Fan Company Maintenance amp Cleaning O i TT a Changing the bulbs carefully remove the globe assembly Unscrew the bulbs and replace with bulbs of the same wattage Reinstall the globe assembly M3556 01 Reverse Switch Changing the direction of air flow move the reverse switch to the opposite position Note The reversing switch is located on the switch housing It can only be accessed when globe is removed 06 17 14 Hunter Fan Company www HunterFan com 1 888 830 1326 Cleaning the fan use soft brushes or cloths to prevent scratching Cleaning products may damage the finishes Troubleshooting www HunterFan com 1 888 830 1326 Fan doesn t work Excessive wobbling Noisy Operation Lights dim when turned on or e Make sure power switch is on e Tighten all of the blade and e Tighten the blade and blade do not turn on at all l blade iron screws until they iron screws until they are snug e Make sure the wattage of the Pull the pull chain to make sure are snug light bulbs installed matches it is on e Check to see if any of the the specifications on the light l l e Turn the power off support blades are cracked If so replace sockets Push the motor reversing switch the fan carefully and check all of the blades firmly left or right to ensure that that the hanger ball is it is engaged properly seated Check the circuit breaker to Use the provided bala
2. hardware bag the X hardware bag connect Connect the black wire connect the 3 grounding the black wire ungrounded ungrounded from the wires green green from the ceiling to the black EA ceiling to the black wire yellow stripe or bare and the blue wires from the d from the fan Connect the copper coming from the J fan Connect the white wire A second ungrounded wire grounded from the ceiling to D p from the ceiling to the blue ceiling downrod and the white wire from the fan wire from the fan hanging bracket papunoisbun For a Single Switch G p D o Z Using an orange wire Turn the splices upward and push them carefully back through the hanger bracket into the outlet box Spread the wires apart with the grounded wires on one side of Refer to CAUTION c 1 on pg 2 the outlet box and the ungrounded wires on the other side of the outlet box M3556 01 06 17 14 Hunter Fan Company www HunterFan com 1 888 830 1326 Position the canopy so that when Lift the canopy into place so that Pza Insert the two canopy screws lifted into place the canopy fits into the screw holes are aligned found in the hardware bag the hanging bracket as shown Note Fan style may vary M3556 01 06 17 14 Hunter Fan Company www HunterFan com 1 888 830 1326 Place each blade between a blade iron Lightly attach the blade irons to the oq and medallion Install t
3. screws securely ta mee Oe FHSS LSZ Install a bulb into each of the sockets When necessary replace with bulbs of the same wattage M3556 01 06 17 14 Hunter Fan Company www HunterFan com 1 888 830 1326 KW Feed the pull chains from the fan switch and the light switch down through the holes in the upper switch housing as shown Attach the pull chain pendants to the light and fan pull chains The fan pull chain controls the speed from high to off The light pull chain controls the light fixture on and off Assembly Screws Partially install two globe assembly screws found in the hardware bag halfway into the light kit assembly as shown It does not matter which two screw holes you choose M3556 01 06 17 14 Hunter Fan Company www HunterFan com 1 888 830 1326 Carefully lower the globe into the globe retainer until it rests in place Globe continued www HunterFan com 1 888 830 1326 Align the keyhole slots in the globe Install the third globe assembly screw assembly with the partially installed and tighten all three screws securely screws in the light kit assembly Lift the globe assembly and twist counterclockwise to lock it into place Make sure the globe assembly is securely attached to the switch housing Failure to properly secure all three assembly screws could result in the light fixture falling M3556 01 06 17 14
4. Downrod for fans installed close to ceiling Included Sold Separately M3556 01 06 17 14 Hunter Fan Company Downrod continued www HunterFan com 1 888 830 1326 T U N O 4 O Remove the pre installed setscrew so that the downrod can be inserted Hand tighten the downrod at The wires can be cut but Tighten the setscrew least 4 5 full turns until it stops leave at least 8 extending with pliers DO NOT from the top of the downrod HAND TIGHTEN If the setscrew is not tightened securely the fan may fall M3556 01 06 17 14 Hunter Fan Company Downrod continued www HunterFan com 1 888 830 1326 Put the wires and downrod through the DO NOT PICK THE FAN UP BY THE canopy Let the canopy sit loosely on top CANOPY OR WIRES Place the downrod of the fan ball into the slot in the ceiling bracket M3556 01 06 17 14 Hunter Fan Company N www HunterFan com 1 888 830 1326 Note To connect the wires hold the bare metal leads CEI together and place a wire RX G gor Live connector over them then twist clockwise until tight 6ulpunolD pepunold pepunosd For Dual Switches Using the orange wire connectors from the X hardware bag connect the white wire grounded from the Using the orange wire ceiling to the white wire REEN TOR connectors from from the fan the amp
5. Shorter Downrod for fans installed close to ceiling EJ Longer Downrod for ceilings 10 feet or higher a Select a downrod length M3556 01 06 17 14 Hunter Fan Company www HunterFan com 1 888 830 1326 Read and Save These Instructions This product conforms to UL Standard 507 A WARNINGS w 1 To reduce the risk of fire electrical shock or personal injury mount fan directly from building structure and or an outlet box marked acceptable for fan support of 70 Ibs 31 8 kg and use the mounting screws provided with the outlet box w 2 To avoid possible electrical shock before installing or servicing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel w 3 To reduce the risk of fire electrical shock or motor damage use only Hunter Solid State Speed Controls w 4 To reduce the risk of personal injury do not bend the blade brackets when installing the blade brackets balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades CAUTIONS c 1 All wiring must be in accordance with national and local electrical codes ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician c 2 Use only Hunter replacement parts Tools Need
6. Table of Contents Congratulations on purchasing your new Hunter ceiling fan It will provide comfort and performance in your home or office for many years This installation and operation manual contains complete instructions for installing and operating your fan We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world To register your fan please visit www HunterFan com register Save your receipt for proof of purchase Blades What to Expect with Your Installation Switch Housing amp Light Kit www HunterFan com 1 888 830 1326 Tools Needed Mounting Options Ceiling Bracket Maintenance amp Cleaning M3556 01 06 17 14 Hunter Fan Company What to Expect with Your Installation NS il 7 A Must be able to secure the fan to building structure or fan rated outlet box You may need a friend to help you Check box to see fan weight If you are unfamiliar with wiring use a qualified electrician Know your wiring Ceiling angles greater than 34 will require an Angled Mounting Kit See page 4 for details a Assess ceiling angle 30 inches from blade tip to nearest wall or obstruction 7 feet from bottom edge of blade to the floor A Assess location Standard Downrod for ceilings 8 10 feet high
7. ed www HunterFan com 1 888 830 1326 amp LI Ladder L Pliers L Wire Strippers E Power Drill 9 64 Drill Bit optional optional If mounting to a support structure you will also need these tools M3556 01 06 17 14 Hunter Fan Company 3 4 CEILING 4a ii Mounting Options www HunterFan com 1 866 268 1936 4 e ka ea ra ka ea a a e o N ea ra o o l O i egoe U p If you have a flat ceiling Hang your fan by a standard downrod included Standard Support Support Mounting Structure T O If you have an angled ceiling InN 0 1 You will need a longer downrod sold separately Outlet Box 2 If your ceiling angle is greater than 34 you will Angled Cellin required also need an Angled Mounting Kit sold separately Mounting N Outlet o required Mounting Use the three steps below to determine if your ceiling angle is greater than 34 Use Standard Mounting Use Angled Mounting BOTH Ceiling amp Wall or Low Profile Mounting to hang the fan from a You need ONLY to hang the fan from a flat ceiling vaulted or angled ceiling a Longer Downrod most common Mounting Kit M3556 01 06 17 14 Hunter Fan Company Ceiling Bracket 4 aa For angled ceilings point opening toward peak Make sure all four bumpers are still attached If you are unable to do this call Technical S
8. he upper switch housing into place M3556 01 06 17 14 Hunter Fan Company www HunterFan com 1 888 830 1326 the hardware bag into place and then tighten all three screws Make sure the upper switch housing is securely attached to the mounting plate Failure to properly secure all 3 assembly screws could result in the switch housing fixture falling e Switch Housing amp Light Kit continued Light Kit Assembly Screw Q Partially install three light kit assembly screws found in the hardware bag into the posts as shown leaving the circled post empty Use only the light kit supplied with this fan model Connect the plugs from the upper and lower switch housings Make sure to line up the colored markings on the connectors M3556 01 06 17 14 Hunter Fan Company www HunterFan com 1 888 830 1326 Align the three keyhole slots in the light kit with the three assembly screws in the posts Lift the light kit and twist clockwise to lock it into place Be sure that both pull chains are hanging freely Make sure the lower switch housing is securely attached to the upper switch housing Failure to properly secure all three assembly screws could result in the light fixture falling Switch Housing amp Light Kit continued Remember the screw you kept after removing the red flag page 13 You need it for this step Install the fourth light kit assembly screw and tighten all four
9. hree blade screws motor with screws found in found in the A hardware bag to attach the X hardware bag then securely the medallion to the blade iron tighten after both screws are attached Your blades are shielded with Dust Armor which is ananotechnology coating that repels dust For cleaning the fan use soft brushes or cloths to prevent scratching Cleaning agents may damage the finishes M3556 01 06 17 14 Hunter Fan Company Switch Housing amp Light Kit www HunterFan com 1 888 830 1326 Red Flag Remove the pre installed light kit Remove and discard the plastic Carefully remove the light kit from the Pza assembly screw and red flag from the connectors from the ends of the upper switch housing and set the light light kit assembly Save the screw It will two pull chains kit aside be needed for light kit installation Note The screw was installed for shipping purposes only M3556 01 06 17 14 Hunter Fan Company Switch Housing amp Light Kit continued Dl Tz EY ENUY iia e OO TT 1 l a S y S SE ee Housing Assembly Screw Partially install two switch housing assembly screws found in the hardware bag into the motor housing as shown It does not matter which two screw holes you choose Feed the wire plug through the center hole of the upper switch housing then wrap keyhole slots around the two screws and twist counterclockwise to lock t
10. ncing ensure the power is turned on kit and instructions to balance Make sure the blades spin freely the fan Turn off power from the circuit breaker then loosen the canopy and check all the connections according to the wiring diagram on page 10 Check the plug connection in the switch housing M3556 01 06 17 14 Hunter Fan Company
11. upport at 1 888 830 1326 Refer to warning w 1 on pg 2 Use wood screws included when securing to support structure with approved electrical outlet box Drill 9 64 pilot holes in support structure to aid in securing ceiling bracket with hardware found in the hardware bag M3556 01 06 17 14 Hunter Fan Company www HunterFan com 1 888 830 1326 Use machine screws provided with outlet box when securing to existing ceiling fan rated outlet box Make sure it is securely installed and is acceptable for fan support of 31 8 kg 70 Ibs or less To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location Motor Housing Gently lower the motor housing so it rests in place on the motor assembly Align the screw holes in the top of the motor housing with the screw holes in the motor assembly Install the three motor housing screws found in the hardware bag M3556 01 06 17 14 Hunter Fan Company www HunterFan com 1 888 830 1326 Downrod www HunterFan com 1 888 830 1326 D Standard Downrod skip to next page for ceilings 8 10 high If you need a different downrod length follow these steps Longer Steps 1 5 to remove standard downrod pipe Downrod for angled ceilings or ceilings 10 or higher Included pre assembled Shorter

Download Pdf Manuals

image

Related Search

Related Contents

R ebuildable atomizer S voёMesto K ayfun v3.1 ES User manual  Equip 610027 wireless presenter  Cooper Lighting Halo L5063039 User's Manual  JVC KD-G646 User's Manual  あなたの取扱説明書 - 株式会社メディア工房  COPPER FUNGICIDE 3-5/8” 3-7/8”  Samsung GW73E-WB Korisničko uputstvo  MANUAL DE UTILIZACIÓN COMPEX 3    テレビドアホン機能一覧表  