1. BIGASS iii No Equal INSTALLATION GUIDE SHL 135 IMPORTANT SAFETY INSTRUCTIONS This guide contains important instructions and safety information Read these instructions prior to installing and operating your light Retain this installation guide for maintenance and troubleshooting information A Specifications Model BAL SHL1 13 YY XX ZZ Electrical specifications 120 VAC 1 0A 122 W 60 Hz Weight 16 Ib 7 3 kg Dimensions 23 09 x 9 18 x 4 63 58 6 cm x 23 3 cm x 11 8 cm Power supply cord length 6 ft 1 8 m J Pre installation A WARNING Unplug power supply cord before servicing A WARNING This product contains high intensity LED devices To prevent permanent eye damage do not stare into the light beam at close range A The installation of Big Ass Light products must be performed by qualified person s in accordance with all applicable codes Code compliance is your responsibility Failure to comply with these codes could result in personal injury or property damage N Maximum ambient operating temperature 55 C 131 F 6 Suitable for damp locations The light includes a 6 ft 1 8 m power supply cord with a plug Ensure power is routed to an approved outlet box at the ceiling before beginning installation Support the fixture so that it does not fall during installation a Conforms to UL Standard 1598 UL Standard 8750 CSA Standard C22 2 No 250 0 and
2. CSA Standard C22 2 No 250 13 HBL INST 20 MUL 01 Hanging the fixture A CAUTION This luminaire must be mounted or supported independently of an outlet box Tools and hardware needed Big Ass Light supplied e 2 1 4 steel zinc plated S hooks Customer supplied e Stud finder Tape measure e Drill 2 minimum 1 4 steel zinc plated lag eye screws Or equivalent minimum 1 4 metallic fasteners with appropriate corrosion protection To hang the light fixture 1 Locate the ceiling joists Mark two drill locations for the mounting holes 16 40 6 cm apart 2 Drill holes into the marks using an appropriate sized drill bit for the lag eye screws 3 Install the lag eye screws in the ceiling and then hang the S hooks from the lag eye screws 4 Hang the two eye bolts on the fixture from the S hooks 5 Plug in the power supply cord Note If the light includes an occupancy sensor it may take up to one minute to turn on after installation The sensor requires time to warm up 6 If necessary use zip ties or cable ties to secure excess power supply cord length above the fixture or to the ceiling Preventive maintenance A WARNING Unplug power supply cord before servicing A CAUTION Do not clean the fixture especially the lenses with scouring pads alkaline cleaning substances gasoline thinner benzene heating oil glycol alcohol or polishing powder A CAUTION Do not pressure
3. to 30 minutes fully clockwise The default setting is 15 minutes 3 Reattach the lens assembly 20 min 15 min Time Delay 25 min 10 min Occupancy sensor troubleshooting Light will not turn ON If the LED in the sensor lens is not flashing check all wire connections If the LED is flashing e Check all wire connections and verify the load wire is tightly secured e Check the light level setting Cover the sensor lens to simulate darkness in the room If the light turns on the light level needs to be adjusted If set to the minimum setting more than 10 fc of ambient light will cause the light to remain off See Configuring the Occupancy Sensor for details on setting the light level If the light still does not turn on contact Customer Service Light will not turn OFF Ensure the time delay is set to the desired delay period and that there is no movement within the sensor s view during that time period To test the sensor for proper operation set the time delay to minimum and move out of the sensor s view The light should turn off after 30 seconds If the light does not turn off contact Customer Service Light will not turn ON after installation or power outage The occupancy sensor requires time to warm up during initial power up Lights with occupancy sensors may take up to one minute to turn on after initial installation or after a long power outage Questions Customers i
4. wash or use a water hose to clean the fixture Big Ass Light suggests an electrical preventive maintenance program similar to that described in the National Fire Protection Association No 70B Recommended Practice For Electrical Equipment Maintenance Clean the fixture periodically with a clean damp cloth If necessary use a mild soap or a gentle liquid cleaner r Configuring the occupancy sensor Note The light includes an occupancy sensor only if ordered A CAUTION Do not overturn the trimpots when adjusting the sensor Do not touch the square infrared detector under the lens assembly To adjust the settings on fixtures with an occupancy sensor 1 Carefully unscrew the lens assembly from the bottom of the light Do not remove the thumbscrew collar that holds the sensor in place 2 Set the light level and time delay using the two trimpots e Light level Specify the ambient light level above which the light will turn off while the space is occupied When the ambient light level drops below the set level while the space is occupied the light will turn on The light level can be set from lt 10 fc to gt 120 fc The default setting is 120 fc maximum At this setting the light will stay on at any ambient light level below 120 fc while the space is occupied e Time delay Specify how long the light will stay on after occupants leave the space The time delay can be set from 30 seconds fully counterclockwise
5. n the United States For questions about your product please contact a customer service representative at 1 877 BIG FANS 877 244 3267 or visit www bigasslight com support Customers outside the United States For questions about your product or customer service inquiries please contact your local Big Ass Light representative or fill out a contact form at www bigasslight com support 5 min Light Level 30 min 30s Time Delay Trimpot Positions 2014 BIG ASS LIGHT LLC ALL RIGHTS RESERVED REV A NOV 2014 WWW BIGASSLIGHT COM 2425 MERCHANT ST LEXINGTON KY 40511