Home
Dale Tiffany TH10099 Installation Guide
Contents
1. connector clockwise until you feel a firmness 111 Try gently to pull the connector off the wires If you can pull the connector off carefully re do the step above and check again for a firm connection IV Connect the negative ribbed wire from the fixture to the white supply wire 8 from the outlet box 4 in the same manner V Separately wrap the wire connections using electrical tape one inch before and include the connector VI If your outlet box is provided with a grounding wire 9 green or bare copper only attach this wire and the bare copper wire from the fixture to the green ground screw by wrapping both wires under the head of the screw and tightening screw If outlet box is not provided with grounding wire attach only the bare copper wire from the fixture to the green grounding screw Tuck all wires into Ceiling Outlet Box 5 Mount Fixture 10 to Crossbar and secure using Decorative Knobs 11 6 Follow Diagram on back side for fixture assembly TH10099 WARNING TO AVOID RISK OF ELECTRICAL SHOCK BE SURE TO SHUT OFF POWER WHILE INSTALLING OR SERVICING THIS FIXTURE 6 Screw the socket assembly B to the tube A 7 Screw the threaded rod C to the socket assembly B 8 Place the shade D over the end of the threaded rod C and tighten with finial E securing the shade in place 9 Insert the bulbs into the bulb sockets FOR RETURN SHIPPING PURPOSES PLEASE RE
2. de la l mpara El uso de una abrazadera de montage es recomendado Advertencias 2 Desempaquete y presente cuidadosamente las piezas 2 a las indicaciones de la ilustraci n y lea las instrucciones antes de comenzar desconectar 3 Seguir los pasos en el diagrama Atornille la abrazadera 3 a la A caja el ctrica 4 con sus tornillos 5 los tornillos no estan incluidos 4 Conecte alambre de suministro con alambre de instalaci n usando conectores de tuerca de alambre 6 Vea por favor conexi n procedimientos abajo Conecte el cable liso positivo de la l mpara con el cable de suministro negro con conector de empalme pl stico 7 de la caja el ctrica 4 I Fije el conector de tuerca de alambre 6 sobre las puntas de los dos alambres y rosque el conector en direcci n de las manecillas del reloj hasta que sienta firmeza 11 Tratar de jalar un poco las conexi nes de los cables para asegurar que estan bien colocadas Si se salen los cables al jalar el conector se devera cuidadosamente volver a conectar y apretar el conector firme a los cables V Conecte el cable estriado negativo de la l mpara con el cable de suministro blanco 8 de la caja el ctrica 4 de distribuci n de la misma forma V Envolver por separado las conexi nes de los cables utilizando cinta adhesiva para conductos el ctricos Envolviendo hasta una pulgada de largo los cables incluyendo el conectores VI Si la caja el ctrica provee de cable de ti
3. Dale Tifa tne ASSEMBLY INSTRUCTIONS Important Safety Instructions Power at the Fuse Box should be disconected before installing this fixture The Fixture ground wire bare or green installed wire is NOT connected to current carrying supply wires The insulation on any of the wires must not be damaged during installation No rough or sharp edges are in contact with any of the wires Fixture wires are connected to the proper house supply wires We recommend professional installation by a licensed electrician Do not use light bulb s with wattage greater than those TH 1 0 099 specified for this fixture Power is off when installing light bulb s into the fixture APX WT 9 LBS Insure the outlet box is well mounted to the building structure and will be able to support the weight of the fixture The use of a crossbar is recommended O Read directions and follow steps 1 9 2 Carefully unpack and layout the parts as shown in illustration and read all instructions before starting 3 Follow numbered steps on diagram Screw Crossbar 3 to Ceiling Outlet Box 4 with appropriate Screws 5 Screws not provided 4 Connect Supply Wire with Fixture Wire using Wire Nut Connectors 6 Please see connection procedures below I Place the positive smooth wire from fixture evenly against with Black supply wire 7 from the outlet box 4 11 Fix the wire nut connector 6 over the ends of two wires and screw the
4. TAIN ORIGINAL PACKAGING TO da o MINIMIZE DAMAGE Uses 2 maximum 60Watt Type A Bulbs or 2 maximum13Watt CFL Bulbs Bulbs not included COMPONENT LIST Item Design Component Qty T Canopy Base AIB i 2 y Re Cc lt _m Threaded Rod 1 pe D Shade 1 pe E Z Finial 1pc DAKE FAKIO Revision 03 05 13 LAYOUT ALL COMPONENTS AND REVIEW PARTS BEFORE ASSEMBLY Made in China Hecho en China Dale Tffary nc INSTRUCCIONES DE ASAMBLEA Instrucciones de seguridad importantes Se debe desconectar la alimentaci n en la caja de fusibles antes de instalar esta l mpara El conductor de tierra de la l mpara desnudo o verde instalado NO debe estar conectado a conductores de suministro que lleven corriente Ninguno de los cables debe sufrir da o en el aislamiento durante la instalaci n No debe haber bordos rugosos o filosos en contacto con alguno de los cables Los cables de la l mpara se deben conectar a los cables de suministro correctos de la casa Recomendamos instalaci n profesional por un electricista licenciado TH 4 0 099 No utilice bombillas de un vataje mayor al especificado de las bombillas para esta l mpara El suministro debe aproximada 9 libras estar cortado durante la instalaci n en la l mpara Aseg rese de que la caja de salida est bien montada en la estructura de la construcci n y de que pueda sostener Lea las instrucciones y siga los pasos 1 9 el peso
5. erra 9 color verde o color cobre solamente conectra el cable de tierra de la caja el ctricia y el cable de tierra de la l mpara al tornillo verde de la abrazadera de montage juntando todos los cables y conectores Gecables 5 Monte l mpara 10 a la abrazadera y segure usando las perillas decortivas 11 6 Seguir el diagrama del lado de atras para seguir las instrucciones del ensamblado de la l mpara TH10099 ADVERTENCIAS PARA EVITAR EL RIESGO DE DESCARGA ELECTRICA ASEGURESE DE APAGAR LA ELECTRICIDAD A DURANTE LA INSTALACION O SERVICIO DE ESTE APARATO 0 o 6 Atornille la asamblea de bombilla B al tubo A ln JO 7 Atornille la varilla roscada C para la asamblea de bombilla B 8 Coloque la pantalla D sobre el extremo de la varilla roscada C fi y y apriete con el flor n E que sujetan la pantalla en su lugar c Inserte las bombillas en los portal mparas MINIMO Uses 2 maximum 60Watt Type A Bulbs or 2 maximum13Watt CFL Bulbs Bulbs not included LISTA DE COMPONENTES Tema Dise o Componente Cantiadad AIB K Tabo Asamblea 1 pieza pa de Bombilla C m varilla roscada 1 pieza D Pantalla 1 pieza E E Remate 1 pieza PIEZAS DE REPUESTO Revision 03 05 13 DESEMPAQUETE TODOS LOS COMPONENTES Y REVISE PIEZAS Made in China Hecho en China ANTES DE LA ASAMBLEA
Download Pdf Manuals
Related Search
Related Contents
ENCUENTRO TÉCNICO 22 DE FEBRERO DE 2008 “Disolventes MANUAL DE INSTRUCCIONES Tecnología de la posproducción Version pdf - Saint OBDⅡアダプター適合表 Deutsch Istruzioni d`uso - VEGAMIP R61 - Unità ricevente Polyepox “O” Universal Home Decorators Collection 1323710210 Use and Care Manual Copyright © All rights reserved.
Failed to retrieve file