TroposAir 88400 Installation Guide
Contents
1. Owner s Manua roposAlir Quantum 4UFOD52 LK C gt Cap for non light use This instruction contains 5 pages Page 1 Foreword Page 2 Unpack and inspect parts contained Page 3 Notes before installation and Hanging system installation Page 4 Wire connection Page 5 Canopy Blade Light kit installation Page 6 Remote amp Setting Net weight Nass S 8 0 KGS Intertek i 3110124 17 6 LBS Toll Free 1 855 676 7247 WARNING Read and follow these instructions carefully and be mindful of all warnings shown throughout READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS PLEASE OBSERVE THE FOLLOWING 1 To ensure the success of the installation be sure to read the instructions and review the diagrams thoroughly before beginning 2 To avoid possible electric shock be sure electricity is turned off at the main power box before wiring All electrical connections must be made in accordance with local codes ordinances and or the National Electric Code If you are unfamiliar with the methods of installing electrical wiring and products secure the services of a qualified and licensed electrician as well as someone who can check the strength of the supportive ceiling members and make the proper installations and connections 3 Make sure that your installation site will not allow rotating fan blades to come in cont
2. Note You may switch Light switch code at D position DIMMING when you change to incandescent bulbs for Down light To use dimming press and hold light button s P6
3. on canopy Rotate canopy slightly until two pre installed screw heads are engaged in the narrow end of key holes Tighten both screws 4 BLADE INSTALLATION With Light Kit Pan Attached 4A Remove the plate at light pan that covers the rectangular hole 4B Insert Blades into Blade slots of Rotating Band Q Fasten blades onto motor assembly through rectangular hole by using the washer amp blade screws provided from hardware bag 4C Re attach the plate in place after blade installation is completed Blade Slot Rotating Band Rectangular Hole Light Pan b Paper Washer O A Blade screw 2 i For use with light kit 5A 5B C Install the bulbs included to the Attach the glass shade by screwing Attach the bottom plate by screwing medium sockets properly it onto the light kit pan clockwise it clockwise onto the light kit pan For non light use 5 SN H gt i 3w ae Medium Sockets Turn on power at breaker box for remote setting P5 6 REMOTE amp SETTING SETTING for light operation before starting fan Pressing the button OFF for 3 5 seconds till the LIGHT BLINKS which means this remote control has done the setting Now the remote is ready for operation D for light dimming for incandescent bulbs LOW Fan low speed MED Fan middle speed HI Fan high speed OFF For SETTING Fan speed Button for ON OFF Light X for light ON OFF x for CFL bulbs
4. act with any object Blades should be at least 7 feet from floor when fan is in operation 4 If possible mount ceiling fan on a ceiling joist the joist must be able to support the motion and weight 4 of the moving fan If the fan will be mounted on a ceiling outlet box a 4 x 2 1 8 deep METAL octagon box is required one UL listed as suitable for fan support The box and its supporting members must not be able to twist or work loose DO NOT USE PLASTIC BOXES Installation on a concrete ceiling should be performed by qualified personnel 5 Blades should be attached after motor housing is hung and in place Fan motor housing should be kept in carton until ready to be installed to protect its finish If you are installing more than one ceiling fan make sure that you do not mix fan blade sets 6 After making electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and the HOT wires on the other side 7 Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL ETL listed and should be installed per the light kit s installation instructions 8 After fan is completely installed check to make sure that all connections are secure to prevent fan from falling and or causing damage or
5. injury 9 The fan can be made to work immediately after installation The bearings are adequately charged with grease so that under normal conditions further lubrication should not be necessary 10 The fan must be turned off and stopped before reversing fan direction 11 This fan is suitable for slope ceiling 12 This fan is reversible 13 This fan includes optional light kit 14 This fan is controlled by remote 15 This fan is suitable for indoor use P1 Unpack and inspect fan carefully to be certain all contents are included Mounting Bracket Downrod Assembly ESD Yoke cover Reverse Switch on top of motor ME N P2 Hardware Bag For Mounting Bracket FlatWasherx2 Spring Washer x2 gt Machine Screw x2 Wood Screw x2 For Wire Connection WireNutx3 For Blade Installation Blade Screw x 9 one spare screw included ne an a ae ee ae ee ee Paper Washer x 9 one spare washer included ogoooeoeoeoe9o797agee7e oe For Blade Balance Balancing Slide x 1 FA Weight block 3G x 3 DOD TD AM crt Buw 130 x2 _ Remote Battery Included DS Hardware Bag Wood Screw x2 S S wente 44l WARNING blades should be at least 7 feet from floor Note 1 Note 2 Turn off power at breaker Use metal outlet box suitable box to avoid possible for fan s
6. s Note Wires from house may vary in color and may not include ground wire green After wiring is completed collect wires neatly inside hanging base From House From Remote From Fan White Motor N Black Motor L for light kit for ground wire from downrod Secure with twist lock wire nuts from mounting bracket 2C Setting code switches for transmitter Remote controls are tuned to operate together using 4 switches for 16 possible code combinations 1 Setting the code on the TRANSMITTER Remove battery cover Slide code switch randomly using a small screwdriver or ball point pen to slide each switch firmly up or down Slide code switch for light ON OFF marked as X or DIMMING marked as D function Important This fan includes 2 CFL bulbs so the code switch should be at X position ON OFF You may switch code at D position DIMMING once incandescent bulbs are installed Install 9V DC battery Included Install battery cover on transmitter Transmitter Code Switches D for light dimming for incandescent bulbs X for light ON OFF for CFL bulbs A Warning CFL bulbs are not applicable to the remote with dimming function 3 CANOPY INSTALLATION Note Two screws are pre installed on mounting bracket for canopy installation Push up canopy until two screws pre screwed on mounting bracket are engaged with two key holes
7. upport electrical shock Outlet box must support 35 Ibs min 1A Installing mounting bracket to ceiling outlet box Install mounting bracket to outlet box in ceiling by using screws included with the outlet box and washers from the hardware bag Outlet Box Mounting Bracket 1B Installing Downrod and Yoke Remove cross pin and cotter pin from downrod Insert downrod through canopy and yoke cover and feed motor lead wires through downrod Loosen 2 downrod jam screws at yoke Insert downrod assembly into yoke Insert the cross pin through yoke amp downrod and secure with cotter pin Tighten both downrod jam screws to further secure downrod Pull down the yoke cover to cover yoke Q Wires Downrod cross Pin cotter Pin lt 0 canopy q 9 Downrod Jam Screw 2 o Downrod Jam Loosening fe Screw 2 Yoke cover p q Tightening lt gt A quessy pojumoq a 1C Hanging the fan Lift fan assembly onto mounting bracket Rotate fan so that the groove on the ball engages the ridge in the mounting bracket Mounting Bracket Ball Groove 2 WIRE CONNECTION 2A Insert receiver into mounting bracket NOTE Do not squeeze all the wires while inserting the receiver into the mounting bracket Mounting Bracket 2B Making electrical wire connection Follow diagram below and make sure that all exposed wires are secured inside wire nut