Home

Kendal Lighting RK60-ORB Instructions / Assembly

image

Contents

1. A C Ensure bulbs are Secure D Step6 Check for loose connections 1 Turn the power to electrical box on 2 Turn on the system and let it run for 5 minutes turn the system off and be careful all connection points are not hot to the touch warm is acceptable if a connection is hot be sure to firmly tighten the connection A Power Feed Connection B Fixture Connections C Ensure bulbs are Secure
2. WARNING RISK OF FIRE AND ELECTRIC SHOCK THIS PRODUCT REQUIRES PROPER FIELD WIRING AND IS INTENDED TO BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY ITEM NO RK60 IMPORTANT SAFETY INSTRUCTIONS Important When replacing Gu10 bulbs be sure the Wattage of the bulb is 50W or less Using higher wattage bulb may damage the fixtures CAUTION To reduce the risk of fire the bare conductors shall be installed a minimum 7 feet from the ground and minimum 6 inches from the ceiling or curtains CAUTION Hot surface keep away from curtains and combustible materials CAUTION Risk of burn before energizing ensure that the bare conductors are free from any metallic objects not part of this lighting system When installing or using the lighting system basic safety precautions should always be followed including the following 1 Read all instructions 2 Do not conceal or extend bus bar conductors through a building wall 3 Do not install this system in damp or wet locations 4 Do not install any part of this system less than 7 feet above floor 5 To reduce the risk of fire and overheating make sure all connections are tight 6 To reduce the risk of fire and burns do not install this lighting system where the uninsulated open bus bar conductors can be shorted or contact conductive materials 7 Do not install any luminaire closer than 6 inches from any curtain or similar combustible materials 8 Turn off electrical power before m
3. odifying the light system in any way or during re lamping Caution To reduce risk of fire use only the type of lamp and maximum wattage marked on the fixtures Caution To reduce risk of fire do not use lamps identified for use in enclosed fixtures Caution Indoor use Caution Use only type GU10 rated 120 volts 50W maximum Please inform your dealer immediately in case of any parts shortage Save these instructions for future reference ITEM NO RK60 ASSEMBLY INSTRUCTIONS Please carefully unpack and place all lamp parts on a flat surface YW LY 3 D 1 Drill a hole in the 2 Use a hammer to tap 3 Using a screw driver and the 4 Secure the standoff ceiling anchor A into the ceiling Screw provide C attach the assembly D to the threaded cup B to the ceiling threaded cup WARNING TO PREVENT ELECTRICAL SHOCK TURN OFF POWER TO FIXTURE LOCATION AT MAIN BREAKER Step2 1 Loosen set screw l and slide down canopy G careful ea not to scratch finish 2 Fasten cross bar E to junction box with screws F 3 Connect the Ground Wire from fixture to crossbar E connect the Ground Wire _E from outlet box to crossbar E Connect the wire Neutral from fixture to wire Neutral from power supply with the R wire nut Connect the wire Live from fixture to wire Live from
4. power supply with the wire F nut 4 Slide up canopy G to the ceiling and tighten set screw I G S ITEM NO RK60 n Step3 Remove cap L and open the adaptor half J of power feed place rail marked this side up into adaptor making sure the two connector tabs are on the same side as the two rail connectors Close adaptor and place cap on adaptor by lining up the indent on cap with the set screw on the adaptor push EN IEN se down and tighten to lock in place Step4 Remove the fixture cap N from each fixture slide the adapter onto the rail and secure the cap N Attention Please read below To Install Rail 1 You will notice a this way up label is affixed to the top of the rail When installing rail to power feed and support the label must point towards the ceiling To install Cylinder or Pendant 2 You will notice an indent onthe cap and a set screw on the adaptor These two must be lined up with each other for easy assembly Once lined up push down on cap and turn clockwise Step5 Tighten the screw on the adapter Place the shade P over the socket clip install the bulb Q Max 50W type GU10 into the socket SS gt RF per A Power Feed Connection B Fixture Connections Ji I ji

Download Pdf Manuals

image

Related Search

Related Contents

Indice de gravité d`une toxicomanie _ rapport de validation  Avaya BCM50 User's Manual  Manual de instrucciones Dama Hydro-C      広告ページです。レポートは次ページから⇒⇒⇒ - TM  SonicWALL TZ 150 Wireless Network Card User Manual  取付取扱説明書 マッ ドガー ド デリ カ D5 ・型式 : cvsw 〇安全上  Sony BI-85 User's Manual  Samsung ST-A500 User Manual  

Copyright © All rights reserved.
Failed to retrieve file