Home

none Y96591 Instructions / Assembly

image

Contents

1. DO NOT RETURN TO RETAILER IF YOU HAVE ANY QUESTIONS OR CONCERNS PLEASE CALL BOND MANUFACTURING TOLL FREE AT 866 771 2663 MONDAY FRIDAY 8AM TO 4 30 PM PST OR EMAIL customerservice bondmfg com OR VISIT OUR WEBSITE AT www bondmfg com Assembly Instruction Item Y96591 WARNING Read these instructions carefully and keep the fountain power off until the following assembly process is completed Notes Choose an appropriate location for the fountain Excessive weight or pressure on any of the fountain sections may cause it to fall Keep pets children or anyone from sitting leaning or climbing on any of the fountain components While fountain is designed to operate as splash free as possible some water splashing out of the fountain is inevitable Place the fountain in a location where any splashing will not cause damage The National Electric Code requires that a ground fault circuit interrupter GFCI be used in the branch circuit supplying fountain pump and other pond equipment Seek your electrical supplies dealer for this device Always keep the fountain working properly with sufficient water and clean of debris and dirt to ensure proper functioning of the pump If necessary clean the fountain with a soft cloth and change the water frequently Due to water evaporation you may see a buildup of white residue on the fountain surface from mineral content in the water supply To prevent such buildup regularly clean the founta
2. e turned clockwise or counterclockwise to adjust 1 Pump 2 Water Faucet 3 Pump plug Troubleshooting TURN OFF THE POWER BEFORE YOU CHECK THE FOLLOWING If pump does not run or lights do not turn on 1 Check the circuit breaker 2 Try another outlet 3 Check the water level in the fountain Running the pump without sufficient water can damage the pump 4 Check the setting of the flow control on the pump and adjust the flow 5 Check the pump discharge and intake for dirt and debris 6 Check the fountain feature tubing for kinks and obstructions 7 The pump might be air locked Plug and unplug the pump several times to release the air inside the pump 8 Check and reconnect all the cords and try again IF YOU HAVE QUESTIONS OR CONCERNS PLEASE CALL BONDS TOLL FREE 1 866 771 BOND 2663 OR TO BETTER EXPEDITE YOUR REQUEST FEEL FREE TO EMAIL US AT customerservice bondmfg com OR LOG IN TO OUR WEBSITE UNDER CUSTOMER SERVICE SUPPORT www bondmfg com YuanHua SUBMERSIBLE PUMP SAFETY INSTRUCTIONS The manipulation and utilization of our pump are very simple and convenient The user just needs to pour a suitable height level of water and link t he pump with the outlet water pipe and then con nect the pump with power supply in accordance with the mark on the label Thus the pump can run well To reduce risk of electric shock Always unplug the pump
3. from the electric outl et before cleaning and handling Use with clean water only Do not place it in o ther liquid Never let the pump run dry OPTION The pump is supplied with grounding conductor and a grounding type attachment plug and must be connected only to a proper ground outlet to reduce the risk of electric shock Do not use the pump in water above 86 F or3 0 C Prevent the water from running into the electr ical outlet down the cord Do not lift carry or pull the pump by the power cord Do not replace the pump cord Stop using the pump if it sustains damage TO clean the pump Unplug the pump from electrical outlet Use a small soft brush or place it under water stream to remove debris To keep water clean Periodically change water to prevent water from becoming sticky and forming microorganisms TROUBLESHOOTING If the pump fails to run the following should be checked Check the circuit breaker or try a different outl et to make sure that the pump is getting electric al power NOTE Always disconnect the pump f rom electrical outlet before checking Check the pump discharge and tubing for kinks and obstructions e Algae buildup can be flushed out with a gar den hose Remove the pump front cover amp plate to acc ess the impeller area Turn the rotor to ensure it is not broken or jammed With little flow rate the pump will spew or burp Check the water level t
4. in with soap and water do not use anything abrasive which may damage the applied finish See the pump instructions for pump safety maintenance and warranty information Keep this manual for future reference Installation amp Assembly e Take out all packaged parts e Place the fountain on a level surface away from areas where it is likely to get clogged with leaves and make sure that the cable will reach the socket e Follow steps to assemble as illustrated below Step 1 Pull out the plastic tube from the bottom of the vase then connect it to pump outlet also pull out the LED cable connect it to transformer Join the top part and the reservoir Step 2 Turn the vase so that it locks onto the reservoir Step 3 Add water to the reservoir plug in Fill the reservoir with clean water or pipe water into fountain from the backdoor Always make sure the water can submerge the pump completely to work properly and prevent the pump damage Plug in the pump and adaptor then switch on the water will start to flow in minutes e Adjust the pump flow rate to achieve the desired effect and to minimize any splashing Splashing can occur if the flow rate is too high or the reservoir is too full The flow rate can be increased or decreased by moving the flow rate control slider on the pump body Moving the switch towards Max will increase the flow rate and moving it towards Min will decrease it On some pumps flow regulator may b
5. o make sure the pump is completely submerged If abnormal noise is heard during operation with water First disconnect the power supply and then r emove pump front cover amp plate Use hand to grip the impeller gently pull the impeller rotor assembly out of the pump housing Rinse the impeller rotor assembly and the cavity with clean water If breakage or surface damage is found on the assembly contact your distributor for part replacement Warning To reduce the risk of electric shock use only on portable self contained fountains no larger than 5 feet in any dimension Exception lf the fountain pump use a SO or ST flexible cord The warning above will not be suitable any more Minimum Water Level Flow control valve CAN PA NES il oS N L e

Download Pdf Manuals

image

Related Search

Related Contents

Mélanger et former des boules de pâte de la taille d`une balle de  この取扱説明書には取り付け方やうンプの交差築方法、お  GC-1355H Spartan 2 Operation    Kapitel 2. Komponente Dr.Web Agent  取扱い説明書  Data Sheet - Lamonde Automation Ltd  Nokia 202 User Guide  Télécharger le PDF - Alpha Techno-prod, fabrication de prothèses  

Copyright © All rights reserved.
Failed to retrieve file