Home

APEC Water Systems FILTER-SET-ESPH Instructions / Assembly

image

Contents

1. leaks Drain the first tank of water through faucet to flush out the new membrane The 204 tank is ready tor use Changing Stage 5 Carbon TCR Filter should be changed with the membrane every 2 3 years To Water Source H G To Drain m a J Membrane Housing IRI Flow Direction O PHFilter T gt P To Faucet To Storage Tank Fig B 1 Remove the OLD filter See Fig B Disconnect the tubing from point H and tubings at point G amp F Use a wrench to unscrew the fitting from the filter s Left hand port then unscrew the T fitting from filter s Right hand port You will put these 2 fittings on the new filter Discard the used filter The new 5th stage filter will come with 2 plastic end caps Please use a flat head screwdriver to remove the caps before proceeding 2 Sanitize Use some mild bleach solution to rinse the 2 plastic fittings 3 tubing tips and the 2 ports of the new filter This is to prevent contamination NOTE Only this filter change needs bleach sanitizing Do Not apply chlorine bleach in anyway to Membrane for it will damage the membrane 3 Connect the 2 fittings and tubing to the new filter as before Make sure the FLOW gt on the filter is pointing to the inlet of the Ph Filter point O Reconnect the tank and C4 Clear tubing back to point G amp F then connect the output tubing to point H Check for leaks Changing PH Filter should be changed at least every 6 12 months 1 Turn OFF
2. APEC ROES PH75 System Filter Change Instruction Changing Stages 1 2 3 Pre Filters should be changed at least every 6 12 months 1 Turn OFF cold water supply to RO system by turning the needle valve stem to the right until it stops or you can turn off the cold main water valve Turn OFF the tank ball valve by turning the blue handle 90 degrees Lift up RO faucet lever briefly to relieve the built up pressure inside the RO system This will make opening the housings easier Open housing Have the RO standing upright Slip the plastic wrench onto the 1 housing Looking down from a top view you should open the housing turning clockwise If necessary lay RO down on the floor to get a better leverage If the housing is too tight use a hammer and gently tap on the wrench handle to help turn the wrench Discard 3 used filters wash housings with mild soap rinse off Put 3 new filters into their respective housings Sediment filter in stage 1 Carbon block filters in stages 2 amp 3 Close up the housings Make sure each housing has a black O ring in the housing grooves Use wrench to tighten each housing Remember Turn ON the cold water supply and OPEN the tank valve after finished changing filters Check for leaks A i After Taking the housing off take out the dirty filters and put a the new 3 pre filters in Remember Stage 2 and Stage 3 1 lt are the same carbon filters p as i q iT Yoto Use APEC WA
3. TER vin Titi Wrench anana a i l W W RO MEMBRANE aoe 3rd 2nd Ist Stage Stage Stage STEPI Fig A Correct Direction Changing Stage 4 Membrane should be changed every 2 3 years 1 Turn OFF the cold water supply to RO system Turn OFF the tank ball valve by turning blue handle 90 degrees Lift up RO faucet lever briefly to relief the built up pressure inside the RO system This will make opening the housings easier See Fig B Locate the Membrane housing on the system labeled Membrane Remove the RED tubing from the housing s cap at point D see Fig B To remove tubing Push In and Hold Down on the collet ring square against the fitting With the collet held in this position the tube can be removed Open up the cap turn counter clockwise Remove the used membrane Discard Insert the new membrane using a pair of pliers Push membrane into housing tightly Avoid touching the Membrane with your hands to prevent contamination Important Make sure the double ring end of the membrane goes into the housing first as shown in Fig A above The membrane cannot filter water if it s inserted in the WRONG direction Close the housing cap Reconnect the RED tubing to the cap by pushing it into the quick connect fitting then gently pull back on the tubing to make sure the connection was secure Turn on the cold water supply and open the tank valve Let the RO system run to re till the tank takes about 2 3 hours Check for
4. cold water supply to RO system Turn OFF tank ball valve by turning the blue handle 90 degrees Lift up RO faucet lever briefly to relief the built up pressure inside the Ro system The will make removing the tubing easier 2 Remove the CLEAR outlet tubing at point P See Fig B To remove the tubing Push In and hold down on the collet ring square against the fitting With the collet held in this position the tube can be removed Once the outlet tubing is disconnected please remove the inlet tubing at point O Remove old filter and discard 3 The new PH filter will come with 2 End Plugs Please remove the plugs before connecting the tubing to the filter 4 To reconnect the tubing to point O and P push the tubing into the Quick Connect fitting then gently pull back on the tubing to make sure the connection was secure Make sure FLOW gt on filter is pointing to the drinking water faucet 5 Please drain a full tank of water before use Check for leaks

Download Pdf Manuals

image

Related Search

Related Contents

Fiche Technique LCB 105 SR prêt à l`emploi  Pulsar Evolution - Electrocomponents  CradlePoint MBR90 User's Manual  PDF版 - 消費者の窓  M-Cab 7300101  Digitus DA-70431 mounting kit  Hobart Welding Products 452 Welder User Manual  Impex SB-241 Owner's Manual  Samsung 931C Kasutusjuhend  Vérin sans tige à entraînement magnétique  

Copyright © All rights reserved.
Failed to retrieve file