Home
KOHLER K-410-K-NA Installation Guide
Contents
1. reserves the right to make revisions in the design of faucets without notice as specified in the Price Book 1015916 2 E 2 Kohler Co Six Round Holes Typical Finished Wall 16 Wall PI 40 6 om 4 a TR gt 1 3 8 3 5 cm Min dd 2 5 8 6 7 cm Max l A Screws 5 5 8 2 1 4 5 7 cm Min 14 3 cm 3 1 2 8 9 cm Max 2 Stud raming 1 Prepare the Site NOTE The wall plate requires special framing and support considerations Pay special attention to minimum and maximum faucet height recommendations noted in the roughing in sheet Refer to the roughing in dimensions for additional mounting information A suggested framing example is shown Each installation may have different framing requirements than those shown Construct the framing for your installation 2 Attach the Wall Plate O Loosely attach the wall plate to the stud framing with six 10 x 1 panhead wood screws not provided Verify that the installation is correct and level and firmly secure the wall plate to the studs Kohler Co 3 1015916 2 E Finished ee de Wall Plaster Edo mw Guards gt 1 2 Hot 1 2 Cold lt Supply Supply 3 Install the Supplies Install 1 2 hot and cold supply piping to the mixer valve O Temporarily pull the plaster guards from the handle and spout shanks Do not discard them at this tim
2. Installation Guide Wall Mount Lavatory Valve K 410 M product numbers are for Mexico i e K 12345M Los n meros de productos seguidos de M corresponden a M xico Ej K 12345M Fran ais page Fran ais 1 Espa ol pagina Espa ol 1 HEBO D LOOK T 101591028 7 KOHLER Tools and Materials F Tube Cutter Tape Solder Measure y S y sx sx oe Pencil Level 10 x 1 Propane Woodscrews Torch Thank You For Choosing Kohler Company We appreciate your commitment to Kohler quality Please take a few minutes to review this manual before you start installation If you encounter any installation or performance problems please don t hesitate to contact us Our phone numbers and website are listed on the back cover Thanks again for choosing Kohler Company Before You Begin CAUTION Risk of property damage Do not use plumbers putty on marble or plastic as it may stain the surface NOTE Follow the installation dimensions precisely as there is no deep rough in kit available for this product Shut off the main water supply Observe all local plumbing and building codes Give special consideration to the exact location desired for your faucet This product is designed to give you the opportunity to be creative and flexible with the installation Site preparation and wall finishing may require additional tools and materials Kohler Co
3. coger a Kohler Antes de comenzar PRECAUCI N Riesgo de da os a la propiedad No utilice masilla en superficies de m rmol o pl stico pues puede producir manchas NOTA Siga las dimensiones de instalaci n con precisi n pues no hay ning n juego de instalaci n profunda disponible para este producto Cierre el suministro principal de agua Kohler Co Espa ol 1 1015916 2 E Antes de comenzar cont Cumpla con todos los c digos locales de plomeria y de construcci n Preste especial atenci n al lugar deseado para la instalaci n de la griferia Este producto le permite ser creativo y flexible con la instalaci n La preparaci n de la instalaci n y el acabado de la pared pueden requerir herramientas y materiales adicionales La empresa Kohler se reserva el derecho de modificar el disefio de la griferia sin previo aviso tal como se especifica en la lista de precios Kohler Co Espanol 2 1015916 2 E Seis orificios Pared tipico acabada 16 Bie 40 6 cm mura 1 3 8 3 5 cm M n 2 5 8 6 7 cm M x Tornillos 5 5 8 2 1 4 5 7 cm Min 14 3 cm t Estructura de 3 1 2 8 9 cm M x postes de 2x4 1 Preparaci n de la instalaci n NOTA La placa mural requiere una estructura y soporte especiales Preste especial atenci n a las recomendaciones sobre la altura m nima y m xima de la grifer a indicadas en la ho
4. drage sp cial et des consid rations de support Pr ter une attention particuli re aux recommandations de hauteur minimale et maximale du robinet mentionn es dans les dimensions de raccordement 2 Installer applique murale Se r f rer aux dimensions du plan de raccordement pour les informations dimensionnelles La structure est illustr e a titre d exemple Votre installation pourrait n cessiter une structure diff rente de celle illustr e Construire le cadrage pour votre installation Fixer sans serrer l applique murale au montant avec six vis a t te cylindrique bomb e 10 x 1 non fournies S assurer que l installation soit correcte et nivel e puis s curiser fermement l applique murale aux montants Kohler Co Fran ais 3 1015916 2 E Mur fini o Renforts x CO E de pl tre eee Alimentation Alimentation lt d eau chaude d eau froide de de 1 2 1 3cm 1 2 1 3 cm 3 4 Installer les alimentations Installer la tuyauterie d alimentation d eau chaude et froide de 1 2 au mitigeur Retirer provisoirement les renforts de pl tre des tiges des poign es et des manches du bec Ne pas les jeter 4 ce moment Placer un seau devant le manche du bec et ouvrir les alimentations d eau du mitigeur Ouvrir doucement les tiges du mitigeur et laisser couler l eau chaude et l eau f
5. e Position a bucket in front of the spout shank and turn on the water supplies to the mixer valve Slowly open the mixer valve stems and allow the hot and cold water to flow from the spout shank for about a minute Close the valve and carefully inspect all connections for leakage Repair if necessary O Turn off the water supplies Open the valve stems to relieve the water pressure Reattach the plaster guards to the handle and spout shanks 4 Finish the Wall NOTE To ensure proper fit and appearance do not oversize the spout and handle shank holes Complete the finished wall with three 1 1 2 3 8 cm diameter holes for the spout and handle shanks Space the hole centers 4 10 2 cm apart Remove and discard the plaster guards when the finished wall is complete 1015916 2 E 4 Kohler Co Guide d installation Valve de lavabo a montage mural Outils et mat riels P Fer Coupe tubes M tre ruban souder A y e Niveau a Vis a bois Chalumeau Crayon bulle 10x1 a propane Merci d avoir choisi la compagnie Kohler Nous appr cions votre engagement envers la qualit Kohler Veuillez prendre s il vous plait quelques minutes pour lire ce manuel avant de commencer l installation Ne pas h siter nous contacter en cas de probl me d installation ou de fonctionnement Nos num ros de t l phone et notre adresse du si
6. ja con el diagrama de instalaci n Consulte el diagrama de instalaci n para m s informaci n sobre el montaje Se ha ilustrado un ejemplo de la estructura aconsejada Cada instalaci n puede tener requisitos distintos a los ilustrados Construya la estructura para su instalaci n 2 Monte la placa mural Monte la placa mural a la estructura de postes sin fijar con seis tornillos para madera de cabeza redonda del n 10 x 1 no incluidos Verifique que la instalaci n sea correcta y est nivelada y luego fije bien la placa mural a los postes 1015916 2 E Espa ol 3 Kohler Co Vastago del surtidor Pared A acabada r Protectores Edo s fz 3 de yeso nun Suministro de Suministro de u agua caliente agua fr a de 1 2 de 1 2 3 Instale los suministros Instale las tuber as de suministro del agua fr a y caliente de 1 2 en la v lvula mezcladora Retire provisionalmente los protectores de yeso de los v stagos del surtidor y la manija No los deseche en este momento Coloque un balde frente al v stago del surtidor y abra los suministros de agua en la v lvula mezcladora Abra lentamente la espigas de la v lvula mezcladora y deje correr agua fr a y caliente por el v stago del surtidor durante un minuto Cierre la v lvula y verifique que no haya fugas en las conexiones Repare de ser necesario Cier
7. re los suministros de agua Abra las espigas de la v lvula para aliviar la presi n de agua Vuelva a montar los protectores de yeso en los v stagos del surtidor y de la manija 4 Acabe la pared NOTA Para asegurar un buen ajuste y apariencia no perfore orificios demasiado grandes para el v stago del surtidor y las manijas Kohler Co Espa ol 4 1015916 2 E Acabe la pared cont Termine la pared acabada con tres orificios de 1 1 2 3 8 cm de di metro para los v stagos del surtidor y las manijas Coloque los centros de los orificios a 4 10 2 cm de distancia Retire y deseche los protectores de yeso una vez terminada la pared 1015916 2 E Espanol 5 Kohler Co 1015916 2 E USA 1 800 4 KOHLER Canada 1 800 964 5590 M xico 001 877 680 1310 kohler com THEBOLDIOOK OF KOHLER 2004 Kohler Co 1015916 2 E
8. roide de la tige du bec pendant environ une minute Fermer la valve et v rifier s il y a des fuites dans les connexions R parer si n cessaire Fermer les alimentations d eau Ouvrir les tiges de la valve pour lib rer la pression d eau R installer les renforts de pl tre aux tiges de poign e et du bec Finir le mur REMARQUE Pour assurez le bon positionnement et la finition de l ensemble ne pas surdimensionner les orifices destin s aux valves et au bec 1015916 2 E Fran ais 4 Kohler Co Compl ter le mur fini avec trois orifices de 1 1 2 3 8 cm pour y passer le bec et les tiges de poign e Ecarter le centre des orifices de 4 10 2 cm les uns des autres Finir le mur cont Retirer et jeter les renforts de pl tre apr s avoir termine le mur Kohler Co Francais 5 1015916 2 E Guia de instalaci n Valvula mural de lavabo Herramientas y materiales N Cortatubos Cinta Soldadura m trica AT KF e Lapiz Nivel Tornillos para Soplete de madera del propano ne 10x1 Gracias por elegir los productos de Kohler Apreciamos su elecci n por la calidad de Kohler Dedique unos minutos para leer este manual antes de comenzar la instalaci n En caso de problemas de instalaci n o de funcionamiento no dude en contactarnos Nuestros n meros de tel fono y nuestra p gina web se encuentran en la ltima p gina Gracias nuevamente por es
9. te internet sont au verso Merci encore d avoir choisi la compagnie Kohler Avant de commencer ATTENTION Risque d endommagement du mat riel Ne pas utiliser de mastic d tanch it sur le marbre ou le plastique sous peine de tacher le mat riau REMARQUE Respecter avec pr cision les dimensions d installation sachant qu il n y a pas de kit de raccordement pour ce produit Couper Valimentation d eau principale Respecter tous les codes de plomberie et de b timent locaux Kohler Co Francais 1 1015916 2 E Avant de commencer cont Pr ter une attention particuli re l emplacement pr cis d sir du robinet Ce produit est con u de mani re offrir au consommateur une opportunit de cr ativit et flexibilit d installation Des mat riaux additionnels pourraient tre n cessaires pour la pr paration du site et la finition du mur Kohler Co se r serve le droit d apporter toutes modifications au design des robinets et ceci sans pr avis comme sp cifi dans le catalogue des prix 1015916 2 E Fran ais 2 Kohler Co Mur fini 7 1 3 8 3 5 cm Min 2 5 8 6 7 cm Max 2 1 4 5 7 cm Min 3 1 2 8 9 cm Max 1 Pr parer le site 16 Al murale G a a Six orifices arrondis Typique Plaque 5 5 8 14 3 cm Cadrage du montant de 2x4 REMARQUE L applique murale requiert un ca
Download Pdf Manuals
Related Search
Related Contents
ダウンロード Notas. DVP-CX995V - Manuals, Specs & Warranty Gefen GEF-HDCAT5-ELRPOL2 Brother PT-900 label printer Copyright © All rights reserved.
Failed to retrieve file