1. ATTACH BATH SHOWER m To permit proper drainage it is essential to elevate the shower tub drain to a MINIMUM of 9 above the finished floor of the installed pump If necessary remember to adjust the height of the shower tub drain upwards to allow proper grade for the plumbing connection to the PUMP Refer to Fig J m f bathtub is connected the 2 connection can be reduced to 1 1 2 with adequate slope into the pump 1 Measure rigid pipe from 2 pump inlet to shower bath drain 2 Cut pipe to fit 3 Connect shower tub to 2 inlet with proper slope ATTACH SINK 1 Measure rigid pipe from sink drain to 1 1 2 pump inlet 2 Cut pipe to fit Step 4 Connect Vent to Vent Stack CAUTION Do NOT use one way air admittance valves also known as cheater vents Macerating pumps need two way air movement CAUTION The pump must be vented to the outdoors per your local plumbing code 1 Measure rigid pipe from vent on pump to vent connection new or existing vent stack 2 Connect rigid pipe to main vent stack of house or directly outdoors Step 5 Connect Discharge Line CAUTION Pump discharge outlet has a built in check valve Do NOT install an additional check valve as this may cause the pump to malfunction 1 Install 1 1 4 ball valve approximately 6 from pump dis charge outlet Plan for accessibility 2 Install 1 1 4 plumbing line to house main waste line There must be at least 3 of run from the pump be
2. NSF has tested and certi O us fied this system to be compliant with the ASME A119 2 3 and B45 1 standards for household macerating sys ASNEATID So tems for the United States and Canada This NSF certification ensures U L electrical compliance to U L 778 CSA BASS Standard 7 1 4 geen f 185 8 a T T eMn we SS 11 3 8 Tall Feet 11 Short Feet ART00104 Rubber Feet Thermal Protection Side Cover Manual Switch Toilet Inlet 1 1 4 Discharge Outlet 1 1 2 Sink Inlet 2 Sink Bathtub or Shower Inlet 1 1 2 Vent Opening Knob to Separate Pump Circuit Protection mMOOM gt ALCO o Planning the Installation The placement of the 120V i GFCI outlet location MUST Plumbing Considerations for Installation meet local code Recommend at least 40 away from bathtub or shower and within 6 of the pump 1 1 4 discharge 1 1 2 vent connected to outside do NOT use one way cheater vents Ensure proper slope on all horizontal runs Water overflow drain 1 1 2 drain for bathtub 2 drain for shower Platform refer to Fig J Ball valve recommended for pump discharge 9 1 1 2 Drain 10 Optional ball valves for pump inlets 11 2 sewage pump flapper check valve 12 Tee wye sewer septic line connection ART00143 a All plumbing fixtures attached to the pump must be located m To ensure efficient waste evacuation the pump must on the same fl
3. must cover at least 1 1 2 toilet outlet non petroleum based products only tighten O 9 Install Toilet and Pump Con t Step 7 Assemble amp Secure Toilet Note Instructions apply to Thetford Rear Discharge Toilet Assemble water tank follow the instruction sheet supplied with Thetford tank BEFORE you begin the steps below ART00183 1 0 6 g Level the toilet ART00183 2 E concrete Note Recommend that a bead of caulk is applied around base of Verify proper placement of hose x WD ART00166 ART00184 1 Offset bolts allow for proper alignment of seat cover on bowl Slide to adjust to toilet Step 8 Prep and Test the System Finish connecting all fittings and fixtures Open water supply valve to toilet and or fixtures Check for leaks correct as needed Plug pump into wall outlet Flush toilet ie NOTE If pump initially runs more than 10 sec onds follow the Prime the Pump directions a fF O N N 6 Check for leaks tighten and adjust clamps and connections as needed 10 21 Secure by hand tightening 8 16 ART00183 3 System Operation es What to Expect m This toilet operates on a different principle than a typical siphon toilet resulting in a different sound and flush action When activated the pump pulses a few times m Water spot in toilet bowl is different
4. 1 8 m Place all components in the desired installation position mark footprint and bolt positions Check for all clearances including doors and cabinets Also be sure to check for verti Using Anchors drill cal clearance for any shower enclosure Refer to Fig G and 2 holes using a 1 2 H masonry drill bit then insert Part 18 Concrete Floor Installation m Ensure that all plumbing and electrical do not interfere with placement of bathroom fixtures 3 S z sS hl m Rough plumbing and electrical are completed to code m The placement of the 120V GFCI outlet MUST meet lo cal code Recommend at least 40 away from bathtub or shower and within 6 of the pump Wood Floor Installation Using Only Screws drill 2 pilot holes using A Warning ponotuse an extension cord as this a 1 4 drill bit is a safety hazard that can cause injury CAUTION To permit proper drainage it is essential to A eevee the shower tub drain to a MINIMUM of 9 above the finished floor of the installed pump If necessary remember to adjust the height of the shower tub drain upwards to allow proper grade for the plumbing connec tion to the PUMP Plan accordingly refer to Fig J ART00190 2 Shower or Tub Floor Height eorn BE SURE the flapper swings freely with minimum flow by IMPORTANT Top of drain opening MUST be elevated AT LEAST 9 above the finished floor of the installed pump ART0
5. Site There are three basic installation options When planning the in stallation note overall width of toilet and offset placement of pump plan for maintenance accessibility OPTION 1 ART00182 1 m INSTALLATION OPTION 1 Pump and Plumbing Behind Wall you need a 3 rigid pipe and 3 pipe coupler not included and shorter foot pads included to achieve the proper drainage slope Dis tance between toilet outlet and pump inlet can not exceed 36 Allow additional space for side to side maintenance access 3 Rigid Pipe Not to exceed 36 OPTION 2 ART00182 2 m INSTALLATION OPTION 2 Pump Exposed and Plumbing in Wall place the pump in front of the wall with the plumbing in the wall Allow addi tional space for side to side maintenance access OPTION 3 ART00182 3 m INSTALLATION OPTION 3 Pump and Plumbing Exposed place the pump and plumbing in front of the wall Allow additional space for side to side maintenance access Install Toilet and Pump nore Unless otherwise noted steps apply to ALL installation options Site Preparation a Drill floor holes for toilet If installing in concrete floor in Complete the following before starting the installation stall anchors but do NOT permanently secure fixtures until instructed Refer to Fig m Installation site floor finished and level within
6. of Serial Number m Refer to the one page warranty statement m Record your product information Keep for future reference PRODUCT INFORMATION Refer to Fig B Register this product at www bathroomanywhere com zs 3 5 s a Date of Purchase Model Serial www bathroomanywhere com 1 Form No 38792 Rev D 09 22 10 Parts Included with Pump ART00119 1x 1 1 2 Parts Included with Thetford Toilet NOTE Parts shown below are referenced in the instructions and apply to Thetford s rear discharge toilet and water tank Your instructions may vary if you are installing a different rear discharge toilet Water Tank ART00192 H 1 1 4 Long Sweep Elbow to install Discharge ART00193 1 4 1 1 2 90 Street Elbow to install Sink Rear Discharge Toilet o 90 Street Elbow to install Shower Tub T L A5 1 1 2 Elbow to install Vent Fig C 1x 2 Plumbing Purchased Separately NOTE Plumbing components pictured below are refer enced in the installation instructions Additional plumbing components are required based on your site 1 1 2 90 Street Elbow to install Vent Ball Valve P6 7 3 Sewage Pump ja Check Valve Flapper Type 3 Coupler for 3 Extension Pipe Technical Specifications The system has the NSF C US certification The National Sanitation Foundation
7. than the water spot in a siphon toilet Cleaning Use only non abrasive non petroleum products to clean the pump Circuit Protection Refer to Fig L item The circuit breaker prevents the pump from operating if the pump becomes jammed by foreign objects After the obstruction is removed press the circuit breaker button to reset the pump for operation Thermal Protection Refer to Fig Litem If the system overheats a light comes on indicating that the system is unavailable for use Once the system cools to an acceptable temperature level the light will turn off indi cating that the system is reset and ready for use Prime the Pump If pump initially runs more than 10 seconds prime the pump as follows a Unplug cord from wall outlet b Wait 15 seconds Plug cord back into wall outlet c Flush again If pump runs more than 10 seconds repeat Steps Clearing the Pump of Debris 2 amp Ss S 2 ce lt x Winterization Bathroom Anywhere systems exposed to freezing temperatures require winterization All fixtures inlet and discharge lines depicted in Fig G must be winterized using non toxic propylene glycol RV Marine Antifreeze Use sufficient quantity of antifreeze to ensure all pipes are protected Steps Shut off water supply Flush toilet to empty tank Pour RV Marine antifreeze into toilet and all fixtures Press manual switch H to run antifreeze through system It may be possible to cl
8. 0194 1 Install Toilet and Pump Con t Step 1 Attach Connections CAUTION Do NOT insert plumbing more than 1 Insert the plumbing connections according to your installation plans deep into plumbing openings Refer to Fig C E and F CAUTION Do NOT glue rigid plumbing to rubber inlet Use the provided clamps Sink brn kia 2 ey te ts 5 Ss a a lt lt Slide over plumbing E l ART00182 2 discharge pipe For maintenance purposes leave at least 1 1 2 of straight plumbing above 2 ome ART00188 3 ART00189 1 Installations with Unused Inlets Installations without Toilet If O and are not attached to a fitting they MUST be covered If is not attached to a toilet it MUST be covered with the cap using with the caps using clamps provided clamp provided ART00088 Install Toilet and Pump Con t Step 2 Attach Labels ART00186 1 Circuit Protection Overheat Protection Place label based on installation visibility TECWA ty THETFORD ART00186 2 Place label near toilet be sure to dry fit ALL plumbing BEFORE permanently bonding plumbing connections Place the pump in the installation position and follow the steps below q CAUTION To verify proper lengths for plumbing Refer to Fig G for Steps 3 5 Step 3 Connect Bath Shower Sink CAUTION Make sure there is proper slope of all horizontal runs
9. 40 pipe fittings as household garbage needed m PVC ABS primer and cement Do not allow the Bathroom Anywhere system to freeze See m 3 pipe extension and 3 coupler depends on installation Winterization m Tee wye sewer connection a Make sure that any pipe work that may be exposed to freez Ball valves sized to inlet and discharge pipe sizes ing temperatures is insulated f m 2 Sewage pump check valve depends on installation m Make sure that plumbing fixtures attached to the pump do not leak If there is a power failure the pump will not oper m For optimal performance use long sweep 90 angles Refer ate and this could cause the unit to overflow and flood to Fig A q CAUTION Do NOT use one way air admittance valves also known as cheater vents Macerating es pumps need two way air movement y Re N Electrical Cautions I ors To ensure safe operation Standard Elbow Long Sweep m The pump must be connected to a properly grounded Two connected 45 angles can be substituted for one long sweep GFCI ground fault circuit interrupter receptacle on a dedicated 15 AMP circuit m Do not use in swimming pool or marine areas ART00180 1 3 m Always disconnect the plug from the power source before servicing or handling the pump m Do not use an extension cord with this unit m Do not make any modifications to or remove the ground pin from the pump s power supply cord plug Warranty a B a a Location
10. Tecma Bathroom Anywhere Tecna BATHROOM 5 SEA NVMMENE Owner s and Installation Manual Installation Please keep this manual for future reference Read ALL these instructions before installing the Tecma Bathroom Anywhere unit Warni ng Read and understand the warnings Required Tools listed in this document before you install operate or service j this system If you do not obey these warnings there ao m Pipe saw risk of property loss injury or electrocution Do not make Philli dri any changes to this unit as this could result in property E a damage injury or electrocution m Flathead screw driver Thetford Corporation accepts no responsibility or liability m 5 16 Socket wrench for damage to equipment injury or death that may result Hammer from the system s improper installation service or opera tion Thetford Corporation recommends that plumbing and elec Tape Measure trical work be performed by a licensed tradesperson Local Drill permit and code compliance is required m Level m 1 2 masonry drill bit Concrete floors A Caution To avoid damaging propertyandto w 1 4 drill bit Wood floors make sure the unit operates correctly please do the x 5 following Materials Not Provided m Do not flush anything other than human organic waste and toilet tissue Do not flush paper towels pre moistened wipes condoms feminine hygiene products dental floss or m 1 1 4 1 1 2 and 2 rigid Schedule
11. ear the pump of debris using the following steps Do NOT use a plunger ARTO0095 Close discharge pipe ball valve refer to Fig G position 8 2 Unplug pump from wall outlet 3 3 Remove 6 place towel ART00090 1 in groove Open discharge pipe ball valve Plug in unit Flush toilet to test configuration Remove plug Quickly insert bag Drain excess liquid into bag re insert A Verify that o rings are positioned securely ARTO0197 ART00089 ART00090 2 Reconnect unit turn clock wise to re connect Follow the Prime the Pump directions until the pump engages Due to back pressure in the discharge line this may require more than one attempt depending on system 11 Service Kits ART00101 No Bathroom Anywhere Toilet Inlet Side Bathroom Anywhere Pump Side w Pump Bathroom Anywhere Toilet Inlet Cap Bathroom Anywhere Vent Shroud White Elongated Slow Close Seat and Lid Bone Elongated Slow Close Seat and Lid 6e Eee Toilet Seat Bolts 2 Offset Bolts For Bathroom Anywhere Elongated Seat Pa sis BatvoomAnyunerOrinegeBeg SSCS fa fem e Questions 1 800 543 1219 See your dealer for more information about Thetford products Or write or call www bathroomanyw here com Thetford Corporation P O Box 1285 Ann Arbor MI 48106 SAY WORE 1 800 543 1219 ostewater transfer system Form No 38792 Rev D 09 22 10
12. fore con necting to main waste line x Note When connecting to the sewer line use direc if tional fittings that meet your local plumbing code Install Toilet and Pump Con t Step 6 Connect Toilet and Pump A MPORTANT Be sure the floor holes are drilled before you begin the following steps ART00196 ART00187 1 ART00187 2 3 ee eee l Ji el eee HINT Sit on the N YV toilet to attach as N N f finished floor S Apply soapy water for lubrication use Drill wall hole Wall hole center must be Position 3 Then apply soapy water A non petroleum based products only located and sized to accommodate pipe A to tne position GA use non slope petroleum based products only A Be sure that 8 covers at least 1 1 2 of toilet outlet N J N S Y Nee ART00187 4 ART00187 6 ART00187 5 8 Y N ZA Cut pipe to fit cannot exceed 36 Insert pipe through wall connect ends ZA must cover at least 1 1 2 of pipe A oo that will be must cover at least 1 1 2 of C Option Step 6 Connect Toilet and Pump Only HINT Sit on the toilet to attach ARTO0195 1 ARTO0195 2 ART00195 3 A Apply soapy water for lubrication use C
13. oor of the building have at least 3 of 1 1 4 discharge pipe before transi ioni i ize m The pump will pump up to 18 vertically or up to 150 hori tioning to a arger pipe size zontally with proper slope m All pipes must be constructed of rigid material such as PVC Do NOT use flexible pipes All fittings should be primed and glued Do NOT glue pipe to rubber tank use clamps provided m f a vertical rise is required it should come before any hori zontal run to allow for proper operation m All inlets in the unit must be connected to a fixture toilet sink etc OR covered with the plugs provided m Installing ball valves near the inlets and discharge pipe will make it easier to remove the unit for maintenance m Do not use any plumbing fixtures sink toilet etc until the pump is installed and tested Be sure the fixtures do not leak as this will cause the pump to continually operate causing excessive wear on the pump Select the right option for your installation Plan GFCI electrical location and placement of all fixtures before you begin the installation Plan for maintenance acces sibility m Shower tub must be elevated to ensure proper drainage A our installation consider the accessibility to Refer to Fig J E y the air vent and water supply CAUTION Make sure all local plumbing and electrical codes are followed when installing the Tecma Bathroom Anywhere pump Which Installation Best Fits My

Download Pdf Manuals

image

Related Search

Related Contents

ASUS T200TA User's Manual  Agrobacterium Transformation Kit  Chamberlain 372LMC Garage Door Opener User Manual  型式承認申請ガイド(タクシーメーター)(PDFファイル)  「スマ保安心さいくる」アプリ 取扱説明書  Informations importantes au sujet des appareils    取扱説明書 保 証 書 取扱説明書・保証書  MSI GX640 User Guide Manual - Downloaded from LpManual.com  Manuel d`utilisation de la maquette VEHICULE ELECTRIQUE A  